Machine Vision Systems

5768 products

Showing 5089 - 5112 of 5768 products

Showing 5089 - 5112 of 5768 products
View
keyence Stock Image
Keyence OP-88951 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88951

Length

10 m 32.8'

keyence Stock Image
Keyence OP-89122 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-89122

Type

M12 Quick-Swap Bracket

Applicable sensor size

M8

Material

Body: SUS303
Nut: SUS304
Toothed washer: SUS304

Weight

Approx. 30 g
1.06 oz

keyence Stock Image
Keyence OP-86930 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence OP-87444 Keyence
Sale price 1,539.00 kr
Only 8 units left

Specifications

Model

OP-87444

Type

Monitor power cable

Cable end

M8 4-pin / Strand wire

Length

5 m 16.4'

keyence Stock Image
Keyence KV-N16EX Keyence
Sale price 3,781.00 kr
Only 3 units left

Specifications

Model

KV-N16EX

Expansion input unit

External connection method

Terminal block

Input terminals

24 VDC mode,5 VDC mode

Maximum input voltage

26.4 VDC

Input rated voltage

24 VDC mode

5.3 mA

5 VDC mode

1 mA

Minimum ON voltage

24 VDC mode

19 V

5 VDC mode

3.5 V

Maximum OFF current

24 VDC mode

1.5 mA

Maximum OFF voltage

1.5 V

Common method

16 points/1 common (2 terminals) *1

Input time constant (four-level switching)

Input time constant setting

OFF to ON: Typ.

25 μs : 10 μs
300 μs : 240 μs
1 ms : 1 ms
10 ms : 10 ms

OFF to ON: Max.

25 μs : 50 μs
300 μs : 290 μs
1 ms : 1.2 ms
10 ms : 11 ms

ON to OFF: Typ.

25 μs : 50 μs
300 μs : 280 μs
1 ms : 1 ms
10 ms : 10 ms

ON to OFF: Max.

25 μs : 150 μs
300 μs : 390 μs
1 ms : 1.2 ms
10 ms : 11 ms

Input impedance

4.3 kΩ

Internal current consumption

20 mA or less

Weight

Approx. 220 g

*1 The KV-N8EX and KV-N16EX have 2 COM terminals, but these are shared internally.

Keyence New Stock Image
Keyence AT2-301 Keyence
Sale price 29,910.00 kr
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence IV3-500CA Keyence
Sale price 20,646.00 kr
In stock, 13 units

Specifications

Model

IV3-500CA

Type

Standard

Installed distance

50 mm 1.97" or more *1

Tools

Available modes

Standard mode / Sorting mode

Tool with standard mode

Learning, Outline, Color area *2, Area *3, Edge pixels, Color average *2, Brightness average *3, Width, Diameter, Edge presence, Pitch,
OCR, Color prohibit *4, Brightness prohibit, Position adjustment, High-speed position adjustment (1-axis edge/2-axis edge), Blob count

Number of tools

Total: 65 tools *5

Field of view

Installed distance 50 mm 1.97": 22 (H) × 16 (V) mm 0.87" (H) × 0.63" (V) to
Installed distance 3000 mm 118.11": 1184 (H) × 888 (V) mm 46.61" (H) × 34.96" (V)

Switch settings (programs)

128 programs (when using SD card) / 32 programs (when not using SD card)

Image receiving element

Type

1/2.9 inch color CMOS

Number of pixels

1280 (H) × 960 (V)

Image history

Number of storable images

100 images *6

Save conditions

Selectable between NG only, NG and OK near threshold *7, and All *6

Focus adjustment

Auto *4

Image data transfer

Transfer destination

Selectable between SD card, FTP server and SFTP server

Transfer format

Selectable between bmp, jpeg, iv3p, and txt, and file names can be modified

Transfer conditions

Selectable between NG only, NG and OK near threshold *8, and All

Exposure time

12 μs to 10 ms

Analysis information

RUN display

Tools list (Judgment results, degree of similarity, or degree of similarity bar display) *8

RUN information

Switchable between OFF, histogram, processing time, count, and output monitor
Histogram: Histogram, degree of similarity (Max., Min., Ave.), Number of OKs, Number of NGs
Processing time: Processing time (latest, Max., Min., Ave.)
Count: Trigger numbers, Number of OKs, Number of NGs, Trigger errors, Strobe errors
Output monitor: ON/OFF status by output *8

Lights

Illumination

White LED

Lighting method

Pulse lighting/ continuously lighting is switchable.

Other functions

Image capture function

Digital zoom (2×, 4×), HDR, High gain, Color filter *2, White balance *2, Brightness correction, AI capture

Tool functions

Additional learning, Mask outline, Masking function, Color extraction/exclusion *2, Color histogram function *2, Monochrome histogram function *3, Scaling function

Utilities

Failing sensor list, Failure hold, Test run, I/O monitor, Security settings (Two-factor password), Simulator *9, Additional FTP/SFTP Image Information,
Multi-position adjustment, Multi-master image registration, High-speed program switching, Auto program switching, Auto setting backup/restore, Threshold changing in RUN

Indicators

OUT, TRIG, STATUS, LINK/ACT, SD

Input

Type

Switchable between non-voltage input and voltage input
For no-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 30 V, ON voltage 18 V or higher, OFF current 0.15 mA or lower, ON current 2 mA (for 24 V)

Number of inputs

6 ports, 3 ports are selectable as IN/OUT

Function

IN1: External trigger,
IN2, IN3, I/O1 to I/O3: Enable by assigning optional functions
Assignable functions: Program switching, Clear error, External master image registration, SD card save cancel

Output

Type

Photo MOS relay output, N.O./N.C. Switchable
Maximum rating 30 V 50 mA, residual voltage 1.5 V or less *10

Number of outputs

6 ports, 3 ports are selectable as IN/OUT

Function

Enable by assigning the optional functions
Assignable functions: Total judgment (OK/NG), Run, Busy, Position adjustment result, Judgment result of each tool, Result of the logical operation of each tool,
Error, SD card error, Variety discrimination result, Master judgment result

Power/I/O

Connector

M12 12 pin A code Male connector

PoE

PoE power Class 3/4/6 *11

Ethernet

Standard

1000BASE-T/100BASE-TX

Connector

M12 8 pin X code Female connector

Network function

FTP client, SFTP client

Interface compatibility

Built-in Ethernet

EtherNet/IP™, PROFINET *12, TCP/IP non-procedure communication

Expanded memory

microSD card (microSD/microSDHC) *13

Ratings

Power voltage

24 VDC +25%/-20% (including ripple) *14

Current consumption

3.3 A or less (without the AI Lighting unit, and including the output load)
1.8 A or less (AI Lighting unit, and including the output load) *15

Environmental resistance

Enclosure rating

IP67 *16

Ambient temperature

0 to +50°C 32 to 122°F (No freezing) *17

Relative humidity

35 to 85% RH (No condensation)

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions *18

Shock resistance

500 m/s2 1640'/s2, 3 times in each of the 6 directions *18

Material

Main unit case: Aluminum die-casting/PBT/TPU
Indicator light cover: TPU
Ethernet connector: Aluminum die-casting/LCP
Front cover: Acrylic (hard coating)
Power connector: Aluminum die-casting/LCP
Nameplate: PET
Water proof cap for the Power connector: PC+ABS alloy
Water proof cap for the Ethernet connector: PC

Weight

Approx. 300 g 10.59 oz (without the AI Lighting unit)
Approx. 495 g 17.47 oz (with the AI Lighting unit)

*1 Removing the polarizing filter is recommended when used at distances of 3 m 9.8' or more.
*2 Color type only.
*3 Monochrome type only.
*4 The focusing position can be automatically adjusted at the time of installation. Disabled during operation. The focusing position can be registered by programs.
*5 Tools can be installed by programs. This is the number of detection tools and position adjustment tools. Up to 64 detection tools can be set. The number of detection tools in Sorting mode are eight tools.
*6 Saves to the sensor’s internal memory. The images saved to the sensor can be backed up to a USB memory stick inserted into the control panel (IV3-CP50) or to the PC where the software for the IV3 Series (IV3-H1) is being used.
*7 Learning tool only.
*8 Can also be displayed on the control panel (IV3-CP50) or the software for the IV3 Series (IV3-H1).
*9 Usable on the software for the IV3 Series (IV3-H1).
*10 Make sure to keep a total of each output with 120 mA or less.
*11 For a PoE power supply device, IEEE802.3at power class 4 or higher is recommended when using the AI Lighting unit, and IEEE802.3bt power class 6 or higher is recommended when the AI Lighting unit is not used. When using PoE operation may be restricted due to power limitation.
*12 Conformance Class B, applicable protocol: LLDP, SNMP.
*13 Use only products recommended by KEYENCE.
*14 When using the OP-88656 (10 m 32.8'), the power voltage is 24 V DC +25%/-10% (including ripple).
*15 The peak current is designed to be smaller if the AI Lighting unit is mounted. The peak current is greater if the AI Lighting unit is not mounted.
*16 Except when the polarizing filter (OP-88640/OP-88641/OP-88644/OP-88645) is mounted.
*17 For situations where the operating ambient temperature will exceed 40°C 104°F, follow KEYENCE’s specified heat dissipation measures to ensure the case temperature does not exceed the rated maximum temperature (65°C 149°F). Check the instruction manual for more information.
*18 Except when the dome attachment (IV3-D10) is mounted.

keyence Stock Image
Keyence ER-GR12P Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

ER-GR12P

Type

Environment-resistant all-metal shielded type Screw type M12 Cable PNP output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

None

Button

Function

Detecting distance

7 mm 0.28" ±10% *2

Response frequency

100 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

21 × 21 mm 0.83" × 0.83"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±20% or less of detecting distance at +25°C +77°F (-40 to -25°C -40°F to -13°F, +55 to +85°C 131°F to 185°F)

Control output

Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP68G (JIS C 0920), IP69K (DIN40050)

Ambient temperature

-40 to +85°C -40°F to +185°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detecting surface and case: SUS316L, Nut: SUS316L, Toothed lock washer: SUS316L
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP)
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 75 g 2.65 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +70°C +158°F or higher is 33% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence OP-87415 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-87415

Applicable product

SJ-E Series

Note

Attaching this product to the SJ-E Series prevents bending. Attach this product at equal intervals.

keyence Stock Image
Keyence OP-94737 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-94737

Overview

Connector cable with M12 on the both edges for connection.

Applicable product

For extension of standard cables of connector sensors FD-P and FW.

Cable end

M12 straight connector - M12 straight connector

Length

1 m 3.28'

keyence Stock Image
Keyence TM-CX10U Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

TM-CX10U

Max. connections

Number of steps

2

Cable length

30 m 98.4' total (10 m 32.8' between devices)

Environmental resistance

Ambient temperature

0 to +45°C 32 to 113°F

Relative humidity

35 to 85% (No condensation)

Weight

Approx. 60 g

keyence Stock Image
Keyence OP-88145 Keyence
Sale price 66,867.00 kr
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence VT-BW10 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

VT-BW10

Type

Weatherproof cover

Applicable product

VT5-W10

keyence Stock Image
Keyence GL-VM119FN Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GL-VM119FN

Beam axis spacing/Lens diameter

10 mm 0.39": ø4 ø0.16"

Number of beam axes

119

Total length

1200 mm 47.24"

Detection height

1180 mm 46.46"

Protection height

1204 mm 47.40"

Minimum detectable object size

ø14 mm ø0.55" *1

Detecting distance

0.3 to 12 m 1.0' to 39.4' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

8.8

OFF→ON

52.8 *3

All blocked→ON

65.3 *4

With channel A or B

ON→OFF

29.0

OFF→ON

82.5 *3

All blocked→ON

124.2 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

141 *5

Receiver

156 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

63 *5

Receiver

70 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

780 g 27.53 oz

Receiver

790 g 27.88 oz

Total

1570 g 55.42 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence OP-87310 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-87310

Overview

O-ring for conversion adapter female.

Applicable product

GP-M adapter (G female) OP-87283

Number included

1 pcs.

Material

FKM

Note

Attached to the GP-M adapter (G female).

keyence Stock Image
Keyence OP-88386 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88386

Applicable product

KV-CA1H, KV-CA1W

keyence Stock Image
Keyence CA-LMA4 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CA-LMA4*1

Type

Coaxial

Optical magnification (reference magnification)

x4

Magnification range

Approx. ±5 % relative to reference axis

WD (at reference magnification)

70.3 mm 2.77" *2

Compatible image sensor size

1/2"

Field of view (at reference magnification)

1/3"

0.9 x 1.2 mm 0.035" x 0.047"

1/2"

1.2 x 1.6 mm 0.047" x 0.063"

2/3"

-

F-stop range (aperture)

26.5

Depth-of-field

172 µm 6.77 Mil*3

Max. TV distortion

-0.22 %

Resolution

4.5 µm 0.18 Mil*4

Mount

C-mount

Ambient temperature/humidity range

0 to +50 °C 32 to 122 °F, 80 % RH (No condensation)

Weight

Approx. 66 g

*1 The above values are all calculated according to optical design values. Actual values for individual lenses will differ according to precision of assembly.
*2 Working distance indicates a working distance of each lens at reference magnification. Working distance will vary depending on magnification adjustment. (Excluding CA-LM1/LMA1)
*3 The indicated depth-of-field is a theoretical value that assumes 1/2" or 2/3" image sensor size and a horizontal resolution of 320 TV lines. (Circle of least confusion is 40 µm 1.57 Mil in the image)
*4 The smallest resolvable feature able to be detected under 550 nm wavelength light.

keyence Stock Image
Keyence CA-DEB10X Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CA-DEB10X

Light source

Color

Blue

Control interface

Connector

Dedicated 12-pin circular connector

Power source

Supplies power via control interface

Environmental resistance

Enclosure rating

IP67 (IEC 60529)

Ambient temperature

0–40°C

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10–500 Hz Power spectral density: 0.05 G2/Hz, 0.5 hours in X/Y/Z directions (IEC 60068-2-64)

Shock resistance

50 G in 6 directions, 3 times each (IEC 60068-2-27)

Size (H×W×D)

116 mm × 116 mm × 53 mm

Standard certifications

CE, FCC, NRTL, KC, UKCA

Material

Main device case: Magnesium die-casting
Front cover: Polycarbonate, acrylic *1

Weight

Approx. 390 g

*1 ESD-safe and IEC 61340-5-1-compliant when used with the OP-88808 (protective attachment for high-intensity smart ring lighting).

Keyence Stock Image
Keyence CA-D1W Keyence
Sale price 6,410.00 kr
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-LF25Y Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence NU-EP1 Keyence
Sale price 3,173.00 kr
Only 5 units left

Specifications

Model

NU-EP1

Name

Communication unit that supports EtherNet/IP™

Ethernet
Specifications

Compliant standards

IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-TX), IEEE802.3af (Power over Ethernet, Class 3)

Transmission rate

10 Mbps (10BASE-T), 100 Mbps (100BASE-TX)

Transmission media

STP or category 3 or higher UTP (10BASE-T),*1 STP or category 5 or higher UTP (100BASE-TX)

Maximum cable length

100 m 328.1' (the length between this unit and the Ethernet switch)

Max. number of connection stages

4 (10BASE-T) 2 (100BASE-TX)*2

EtherNet/IP™

Compliant functions

Cyclic communication (implicit messages), message communication (explicit messages)

Number of connections

64

RPI (Transmission cycle)

0.5 to 10,000 ms (in units of 0.5 ms)

Tolerable communication bandwidth for cyclic communication

6,000 pps

Message communication

Supports UCMM, Class 3

Conformance test

Supports version A7

Sensor connection

Connectable sensors

Sensor amplifier that supports N-bus*3

Number of connectable units

16 maximum*4

Power supply

Power is supplied by this unit through the sensor amplifier connection connector.

Allowable passing current

Total: 1,200 mA or less*5

Power during PoE power receiving

Supply voltage: 24 V ±10 %, supply current: 360 mA or less*6 (UL Class 2)*7

Indicator lamp

Link/activity indicator (LINK/ACT): green LED, module status indicator (MS): 2-color (green and red) LED, network status indicator (NS): 2-color (green and red) LED, sensor communication indicator (N-bus): 2-color (green and red) LED

Power voltage

24 VDC ±10 %, ripple (P-P): 10 % or less (when using the power supply connector); 48 VDC (57 V maximum; during PoE power receiving)

Power consumption

1,500 mW or less (60 mA or less at 24 V)*8

Environmental resistance

Pollution degree

2

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit case and dust cover: polycarbonate, power supply connector: polyamide (plug), PBT (socket)

Accessories

Instruction manual, power supply connection connector, end unit x 2

Weight

Approx. 80 g (including connectors)

*1 When using the PoE power receiving function to form a connection, use an STP cable or category 5 or higher UTP cable.
*2 When using the switch, there is no limit on the number of units that can be connected.
*3 "N-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*4 This varies depending on the connected sensor amplifiers.
*5 This is the current that can be supplied to the main unit or to the sensor amplifier connected to the main unit.
*6 This varies depending on the ambient usage temperature. (-20 to 45 °C -4 to 113°F: 360 mA or less, 45 to 50 °C 113 to 122°F: 260 mA or less, 50 to 55 °C 122 to 131°F: 140 mA or less)
*7 Power which can be supplied to the sensor amplifi er when using the PoE power receiving function
*8 The current supplied to the connected sensor amplifiers is not included.

keyence Stock Image
Keyence OP-89130 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-89130

Type

High-flex *1 *2

Sensor side

Connector size

M8 3-pin

Appearance

Straight

Cable connector

Connector size

M12 4-pin

Appearance

Straight

Length

10 m 32.8'

Material

Cable: PVC,
Connector: Nickel-plated brass

Weight

Approx. 270 g
9.53 oz

*1 Use a heat/cleaning-resistant cable for the weld-resistant all-metal type in environments of 80°C 176°F or higher and for the environment-resistant all-metal type in environments of -25°C -13°F or lower or at 80°C 176°F or higher.
*2 When used with the general-purpose all-metal type or the environment-resistant all-metal type, the enclosure rating is IP67.

keyence Stock Image
Keyence LV-L02 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

LV-L02

Type

Lens attachment for the LV-NH47/LV-H47

Area width

Standard mode

Detecting distance at 55 mm 2.17": 17 mm 0.67"
Detecting distance at 70 mm 2.76": 20.5 mm 0.81"
Detecting distance at 85 mm 3.35": 24 mm 0.84"

When slit 1 is equipped

Detecting distance at 55 mm 2.17": 13.0 mm 0.51"
Detecting distance at 70 mm 2.76": 15.5 mm 0.61"
Detecting distance at 85 mm 3.35": 18.0 mm 0.71"

When slit 2 is equipped

Detecting distance at 55 mm 2.17": 11.0 mm 0.43"
Detecting distance at 70 mm 2.76": 13.0 mm 0.51"
Detecting distance at 85 mm 3.35": 15.0 mm 0.59"

When slit 3 is equipped

Detecting distance at 55 mm 2.17": 8.5 mm 0.33"
Detecting distance at 70 mm 2.76": 10.0 mm 0.39"
Detecting distance at 85 mm 3.35": 11.5 mm 0.45"

When slit 4 is equipped

Detecting distance at 55 mm 2.17": 6.0 mm 0.24"
Detecting distance at 70 mm 2.76": 7.5 mm 0.30"
Detecting distance at 85 mm 3.35": 9.0 mm 0.35"

Area thickness

Detecting distance at 55 mm 2.17": 3.0 mm 0.12"
Detecting distance at 70 mm 2.76": 3.4 mm 0.13"
Detecting distance at 85 mm 3.35": 3.8 mm 0.15"

Material

Case

Polyacetal (main body), Arton (lens)

Weight

Approx. 1 g

Keyence Stock Image
Keyence OP-87445 Keyence
Sale price 2,297.00 kr
Only 5 units left

Specifications

Model

OP-87445

Type

Panel power cable

Cable end

M8 4-pin - strand wire

Length

10 m 32.8'

Recently viewed