Specifications
Model |
PR-FB15C3PL*1 |
|||
Type |
Reflective (Background suppression) |
|||
Output |
PNP |
|||
Shape |
Flat |
|||
Cable connection |
M8 connector (3 pin) |
|||
Detection distance |
1 to 15 mm 0.04" to 0.59" |
|||
Number of control outputs |
1 output |
|||
Output operation |
Output 1 |
- |
||
Output 2 |
Light-ON |
|||
Response time |
Output 1 |
- |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. 2.5 x 4.5 mm (at 15 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including 10 % ripple (P-P) |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 10 g |
|||
*1 The M8 connector (3 pin) type has 1 control output. If "D" is at the end of the part number, the sensor is equipped with a Dark-ON output. If "L" is at the end of the part number, the sensor is equipped with a Light-ON output. Example: The PR-M51C3PL has a Light-ON output. | ||||


Specifications
Model |
FR-LP20L |
|||
Type |
Long range Chemical model |
|||
Measuring range |
Up to 15 m 49.2'*1 |
|||
Display range |
Up to 25 m 82.0'*1 |
|||
Measurable dielectric constant of medium |
2 or higher*2 |
|||
Resolution |
1 mm 0.04" |
|||
Precision |
Up to 0.1 m 0.3': ±10 mm 0.39"; |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||
Tank pressure |
-0.1 to +0.1 Mpa |
|||
Material |
Tank interior |
Lens: PTFE |
||
Housing |
PPS PPSU |
|||
Connection diameter |
G1-1/2 (40 A) |
|||
Output |
No. of control outputs |
Maximum 5 |
||
Control output/auxiliary output |
NPN/PNP open collector (switching type) |
|||
Analog output |
0–20 mA/4–20 mA maximum load resistance 260 Ω |
|||
External input |
─ |
|||
Network compatibility |
IO-Link v1.1/COM2 |
|||
Analog output accuracy |
Resolution |
1 mm 0.04"*4 |
||
Zero accuracy |
±0.1 mA (zero point = 4 mA)*4 |
|||
F.S. accuracy |
±0.2 mA (full-scale = 20 mA)*4 |
|||
Power supply |
Power voltage |
24 VDC + 25%/–20% |
||
Power consumption |
98 mA or less (Excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
Display part when combined and separated: –10 to +50°C 14°F to 122°F (no freezing)*5*6 |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Temperature of coupling used |
–10 to +85°C 14°F to 185°F (no freezing)*5*6 |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Enclosure rating |
IP67 (IEC60529), Enclosure Type 4X (NEMA250) |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||
Weight |
Approx. 400 g 14.11 oz |
|||
*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened. | ||||

Specifications
Model |
CV-200M |
|||
Type |
Camera*1 |
|||
Image element |
1/1.8-inch monochrome CCD image receiving element, square-pixel/all-pixel reading, 2,010,000 pixels |
|||
Valid pixel count |
1,920,000 pixels 1600 (H) x 1200 (V) *2 |
|||
Pixel transfer frequency |
40 MHz |
|||
Scanning system |
Progressive (58.5 ms: 2,000,000-pixel mode, 47.6 ms: 1,000,000-pixel mode) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values. |
|||
Lens mount |
C mount |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 110 g (not including lens) |
|||
*1 The CA-CN17 camera cable (17 m 55.8') and the CA-CN17R high-flex camera cable (17 m 55.8') cannot be used. | ||||

Specifications
Model |
FU-35A |
|||
Detecting method |
Diffuse Reflective |
|||
Size |
M3 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
0.5 m |
|||
Shape |
Straight |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Detection distance |
20 mm0.787"*1 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 The detecting distance is a value for white mat paper (the standard detection object) detections. | ||||


Specifications
Model |
OP-83181 |
|||
Type |
Deadspace-free Bracket |
|||
Applicable product |
SL-C, SL-V |
|||
Number included |
2 pcs. |
|||
Material |
SUS304 |
|||
Note |
Holding sensor main body from the side. |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
IV-M30 |
|||
Supported languages |
Japanese/English |
|||
Display |
3.5" TFT color LCD 320 x 240 dot (QVGA) |
|||
Backlight |
Method |
White LED |
||
Duration |
Approx. 50,000 hours (25 °C 77 °F) |
|||
Touch panel |
Method |
Analog resistive |
||
Actuating force |
0.8 N or less |
|||
Indicators |
PWR, SENSOR |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*1 |
||
Connector |
M12 4pin connector*1 |
|||
Expanded memory |
USB memory*2 |
|||
Rating |
Power voltage |
24 VDC ±10 % (including ripple) |
||
Current consumption |
0.2 A or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 80 % RH (No condensation)*3 |
|||
Drop Resistance |
1.3 m 4.27' over the concrete (2 times each in the arbitrary direction) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 180 g |
|||
*1 This is dedicated for connection with IV-series sensor. | ||||



Specifications
Model |
PR-MB15CN |
|||
Type |
Reflective (Background suppression) |
|||
Output |
NPN |
|||
Shape |
Mini-slim |
|||
Cable connection |
M8 connector (4 pin) |
|||
Detection distance |
1 to 15 mm 0.04" to 0.59" |
|||
Number of control outputs |
2 |
|||
Output operation |
Output 1 |
Light-ON |
||
Output 2 |
Dark-ON |
|||
Response time |
Output 1 |
0.5 ms |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. ø3 mm (at 15 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 13 g |
|||

Specifications
Model |
CA-H048CX |
|||
Image element |
Color CMOS, 16× high-speed reading using square-pixel |
|||
Unit cell size |
4.8 µm × 4.8 µm 0.19 Mil × 0.19 Mil |
|||
Valid pixel count |
0.47 megapixel mode: 784 (H) × 596 (V), 0.31 megapixel mode: 640 (H) × 480 (V), 0.24 megapixel mode: 512 (H) × 480 (V) |
|||
Image size |
Equivalent to 1/3" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
195 MHz |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.022 to 1000 msec by specifying the following numerical inputs: |
|||
Lens mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to 40°C 32 to 104°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 190 g (not including lens) |
|||

Specifications
Model |
GV-21P |
|||
Type |
Amplifier Unit, Main Unit |
|||
Power consumption |
Normal |
2200 mW max. (at 30 V: 73.3 mA max.) |
||
Eco-Half |
1700 mW max. (at 30 V: 56.7 mA max.) |
|||
Eco-All |
1600 mW max. (at 30 V: 53.3 mA max.) |
|||
Display indicator |
Dual 7-segment display (Current Value: 3-digit red LED indicator, Preset Value: 3-digit green LED indicator) |
|||
Output |
PNP |
|||
Control output |
PNP open collector x 2ch, 30 V DC max./Max. 100 mA, residual voltage 1 V max. |
|||
Control input |
Emission stop input, Bank switching input, Shift input, Timing input, Each input response time: 20 ms |
|||
Response time |
1.5/3/10/20/50 ms |
|||
Operation status indicators |
Control output: Red LED x 2 Channel display: Green LED x 2 Laser radiation emission indicator |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 %*1 |
||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing material, display cover: Polycarbonate, Key Top: Polyacetal, Cable: PVC |
|||
Weight |
Approx. 110 g |
|||
*1 If expansion units are added, supply voltage must be 11 to 30 VDC. | ||||

Specifications
Model |
ED-118M |
|||
Type |
Shielded |
|||
Shape |
M18Threaded type |
|||
Detecting distance |
5 mm 0.20" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
18 x 18 mm 0.71" x 0.71" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
100 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 150 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
GL-VB03 |
|||
Number included |
Mounting bracket: 2 |
|||
Material |
Mounting bracket: SUS304 |
|||
Weight |
50 g 1.76 oz *1 |
|||
*1 GL-V Mounting includes two mounting brackets. The weight stated is for both items. | ||||

Specifications
Model |
CL-V050 *1 |
|||
Type |
Sensor head (50 mm vacuum and heatresistant model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-86H*1 |
|||
Optical axis diameter |
ø1.5 mm0.059" |
|||
Heat resistant temperature |
150°C 302°F*2*3 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R20 mm0.787" |
|||
Minimum detectable object |
Object with a diameter of 0.005 mm0.0002"*4 |
|||
Environmental resistance |
Ambient temperature |
-40 to +150 °C -40 to 302 °F |
||
Weight |
Approx. 35 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
CL-L030N |
|||
Type |
Optical unit |
|||
Head |
CL-L030 *1 |
|||
Reference distance |
30 mm 1.18" |
|||
Reference measurement range |
Measurement range |
±3.7 mm ±0.15" |
||
Linearity |
±0.94 μm ±0.000037" *2 |
|||
High precision measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.72 μm ±0.000028" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø500 μm ø0.0197" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 200 g 7.06 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
OP-42218 |
|||
Type |
Replacement filters for the electrode cleaning kit |
|||
Number included |
10 |
|||

Specifications
Model |
OP-92737 |
|||
Type |
Adapter |
|||
Overview |
When using FS2-60/62/65, this adapter and fixing ring are necessary to mount fiber unit. |
|||
Applicable product |
Fiber unit with cable outer diameter ø1.0 (Free-cut) |
|||
Note |
Attached to the amplifier. Please purchase when additionally necessary. |
|||

Specifications
Model |
FU-38*1 |
|||
Beam emitting direction |
Flat |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||