Specifications
Model |
CA-DZB30 |
|||
LED color |
blue |
|||
Power consumption |
28.4 W*1 |
|||
Weight |
Approx 880 g |
|||
*1 The power consumption exceeds 20 W, so the CD-DC100 cannot be used. | ||||

Specifications
Model |
LV-B302 |
|||
Type |
Mounting Bracket for Landscape Orientation |
|||
Applicable product |
LV-NH300/H300 |
|||

Specifications
Model |
OP-88896 |
|||
Female |
M12 8pin L-shape |
|||
Male |
Strand wire |
|||
Length |
2 m 6.6' |
|||
Material |
cable: PVC |
|||

Specifications
Model |
SJ-E228H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2340 mm 92.13"*3 |
|||
Total length |
2240 mm 88.19" |
|||
No. ofelectrodes |
73 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2350 g 82.89oz |
|||
*1 Measured under the following conditions. | ||||


Specifications
Model |
FS-N42P |
|||
Type |
Cable |
|||
Output |
PNP |
|||
Main unit/expansion unit |
Expansion unit |
|||
Response time |
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
1 |
|||
Number of external inputs |
― |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*3 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4 |
||
Power consumption |
During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*6 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 48 g |
|||
*1 Restrictions when S-HSPD is selected | ||||


Specifications
Model |
SV2-D3BG |
|||
Type |
Motor power cable, Hi-flex robotic cable with electromagnetic brake |
|||
Length |
3 m 9.8' |
|||
Note |
for 200 W / 400 W motor |
|||

Specifications
Model |
GL-VM24HP |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
24 |
|||
Total length |
480 mm 18.90" |
|||
Detection height |
460 mm 18.11" |
|||
Protection height |
505 mm 19.88" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.8 |
|
OFF→ON |
46.7 *3 |
|||
All blocked→ON |
53.2 *4 |
|||
With channel A or B |
ON→OFF |
13.0 |
||
OFF→ON |
63.2 *3 |
|||
All blocked→ON |
80.9 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
81 *5 |
||
Receiver |
92 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
52 *5 |
||
Receiver |
58 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
320 g 11.29 oz |
||
Receiver | ||||
Total |
640 g 22.59 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||


Specifications
Model |
CA-LH50P |
|||
Focal point |
50 mm 1.97" |
|||
F-stop range (aperture) |
F2.8/4/8/16*1 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Mount |
C-mount |
|||
Max. compatible image sensor size |
2/3" |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
TV distortion |
-0.03% |
|||
Enclosure rating |
IP64 (objective lens, water repellent coating specifications)*3 |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 85 g |
|||
*1 The f-stop (aperture) is changed by replacing the diaphragm plate. When this product is shipped, the OPEN diaphragm plate is attached to the lens, so replace it with one of the other included diaphragm plates (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-C10CG |
|||
Type |
Motor power cable, Hi-flex robotic cable |
|||
Length |
10 m 32.8' |
|||
Note |
for 750 W motor |
|||

Specifications
Model |
EH-416 |
|||
Type |
Standard , Non-shielded , Cylindrical and threaded |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
20 x 20 mm 0.79" x 0.79" |
|||
Stable detecting range |
0 to 6 mm0.24" |
|||
Maximum detecting distance |
13 mm0.51" |
|||
Hysteresis |
0.05 mm0.002" |
|||
Repeatability |
0.012 mm0.0005" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 72 g (including nuts and 3-m 9.8' cable) |
|||


Specifications
Model |
OP-51625 |
|||
Overview |
Bottom-mounting bracket for the MS2-H50. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H50 |
|||
Weight |
Approx. 79 g |
|||

Specifications
Model |
ER-GM12P03C |
|||
Type |
General-purpose all-metal shielded type Screw type M12 Connector with pigtail (M12 4-pin) PNP output Mid-Range |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
4 mm 0.16" ±10% *2 |
|||
Response frequency |
150 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
12 × 12 mm 0.47" × 0.47" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303, Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 50 g 1.77 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types. | ||||

Specifications
Model |
OP-91127 |
|||
Type |
Mounting Fittings |
|||
Overview |
Dedicated mounting bracket for PQ. Transmitter/receiver setup. |
|||
Applicable product |
PQ-01, PQ-02 |
|||
Number included |
2 pcs. |
|||
Material |
Steel (Black chromate) |
|||


Specifications
Model |
CL-V020G |
|||
Type |
Optical unit |
|||
Head |
CL-V020 *1 |
|||
Reference distance |
20 mm 0.79" |
|||
Reference measurement range |
Measurement range |
±1.3 mm ±0.05" |
||
Linearity |
±0.3 μm ±0.000012" *2 |
|||
High precision measurement range |
Measurement range |
±0.5 mm ±0.02" |
||
Linearity |
±0.23 μm ±0.000009" *2 |
|||
Resolution |
0.01 μm *3 |
|||
Spot diameter |
ø20 μm ø0.0008" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP40 degassed structure for vacuum environments *4 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 200°C -4 to 392°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Ultra-high-vacuum environments *5 |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.013% of F.S./°C *6 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 100 g 3.53 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
OP-87667 |
|||
Type |
Plate nut for flat |
|||
Applicable product |
PR-F Series |
|||
Number included |
2 pcs. |
|||
Material |
SUS316L |
|||
Weight |
Approx. 1 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-32*1 |
|||
Optical axis diameter |
ø0.6 mm0.024" |
|||
Beam emitting direction |
Side |
|||
Fibre unit length |
1 m39.37" free-cut |
|||
Fibre unit diameter |
ø1.3 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||