Specifications
Model |
S-P12 |
|||
Type |
Tough mounting bracket |
|||
Applicable product |
PZ2 Series |
|||
Number included |
1 unit |
|||

Specifications
Model |
GL-VP2 |
|||
Type |
Main unit connection cable |
|||
Number included |
1 pc. |
|||
Cable end |
Female side: M12 connector 5 pin |
|||
Number of cores |
5 |
|||
Length |
2 m 6.6' |
|||
Material |
connector: PVC/Nickel-plated brass |
|||
Weight |
130 g |
|||

Specifications
Model |
DL-EC1A |
|||
Ethernet |
Compliant standards |
IEEE802.3u (100BASE-TX) |
||
Transmission speed |
100 Mbps (100BASE-TX) |
|||
Transmission interface |
Category 5e or higher STP cable |
|||
Distance between |
100 m 3937.01' |
|||
Communication port |
RJ-45 x 2 |
|||
EtherCAT |
Compatible functions |
Process data object communication (cyclic communication) |
||
Conformance test |
Complies with V2.0.42 |
|||
Sensor |
Connectable |
Sensor amplifiers with D-bus support*1 |
||
Number of |
15 units max.*2 |
|||
Indicator lamps |
Power indicator (PWR): Green LED |
|||
Power voltage |
20 to 30 VDC, including ripple (p-p) of 10 % |
|||
Power consumption |
2,100 mW or less (at 30 V, 70 mA max.) |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit: Polycarbonate |
|||
Weight |
Approx. 70 g (including connectors) |
|||
*1 D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers. | ||||

Specifications
Model |
GL-VM06LN |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
6 |
|||
Total length |
240 mm 9.45" |
|||
Detection height |
200 mm 7.87" |
|||
Protection height |
285 mm 11.22" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.1 |
|
OFF→ON |
45.7 *3 |
|||
All blocked→ON |
51.2 *4 |
|||
With channel A or B |
ON→OFF |
10.0 |
||
OFF→ON |
54.9 *3 |
|||
All blocked→ON |
68.2 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
60 *5 |
||
Receiver |
73 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
48 *5 |
||
Receiver |
56 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
170 g 6.00 oz |
||
Receiver | ||||
Total |
340 g 12.00 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CA-DQR15 |
|||
Type |
Square Lights (Direct) |
|||
LED color |
red |
|||
Diffusion plate |
OP-87042*1 |
|||
Power consumption |
14.4 W*2 |
|||
Weight |
Approx 520 g |
|||
*1 The models listed on the left are for a single bar. Four sets are required for the whole square. | ||||

Specifications
Model |
GL-R08L |
|||
Detection capability |
ø1.77" ø45 mm |
|||
Total length |
12.60" 320mm |
|||
No. of beam |
8 |
|||
Detection height |
11.02" 280mm |
|||
Protection height |
14.37" 365mm |
|||
Beam axis spacing/Lens diameter |
40 mm / ø5 1.57" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
6.6 |
|
OFF→ON |
48.7*2 |
|||
All blocked→ON |
63.1*3 |
|||
Optical synchronization system |
ON→OFF |
6.9 |
||
OFF→ON |
49.1*2 |
|||
All blocked→ON |
64.2*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
41 |
||
Receiver |
68 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
430 g |
||
Receiver |
440 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||


Specifications
Model |
GL-VM191FP |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
191 |
|||
Total length |
1920 mm 75.59" |
|||
Detection height |
1900 mm 74.80" |
|||
Protection height |
1924 mm 75.75" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
11.9 |
|
OFF→ON |
61.3 *3 |
|||
All blocked→ON |
78.4 *4 |
|||
With channel A or B |
ON→OFF |
41.1 |
||
OFF→ON |
118.8 *3 |
|||
All blocked→ON |
178.6 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
187 *5 |
||
Receiver |
213 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
66 *5 |
||
Receiver |
80 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1250 g 44.12 oz |
||
Receiver |
1260 g 44.47 oz |
|||
Total |
2510 g 88.60 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CL-P030G |
|||
Type |
Optical unit |
|||
Head |
CL-P030 *1 |
|||
Reference distance |
30 mm 1.18" |
|||
Reference measurement range |
Measurement range |
±3.7 mm ±0.15" |
||
Linearity |
±0.81 μm ±0.000032" *2 |
|||
High precision measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.59 μm ±0.000023" *2 |
|||
Resolution |
0.015 μm 0.000001" *3 |
|||
Spot diameter |
ø38 μm ø0.0015" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 200 g 7.06 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
OP-87569 |
|||
Cable end |
M12 L-shaped type - Loose wires |
|||
Length |
5 m 16.40' |
|||
Material |
Covering: PVC, Nut: Nickel plating over zinc die-cast |
|||

Specifications
Model |
GS-71PCSO(3197) |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
EV-130F |
|||
Type |
Spatter-resistant/Shielded |
|||
Shape |
M30 |
|||
Detecting distance |
10 mm 0.39" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
30 x 30 mm 1.18" x 1.18" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
250 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 200 mA |
|||
Protection circuit |
Reversed polarity, short-circuit, surge voltage |
|||
Cable length |
2 m 6.6' |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Fluoro-chemical-coated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 300 g |
|||


Specifications
Model |
OP-87551 |
|||
Overview |
Anti-condensation mounting brackets (G3/4) for the FL-001. |
|||
Applicable product |
FL-001 |
|||
Material |
SUS303 |
|||
Note |
2 gaskets for the FL-001 (OP-87548) are included. |
|||



Specifications
Model |
LM-1100 |
|||
Type |
Head |
|||
Image sensor |
1", 20-mega pixel monochrome CMOS |
|||
Display |
10.4" LCD monitor (XGA: 1024 × 768) |
|||
Receiver lens |
Double telecentric lens |
|||
Image measurement |
Field of view |
Wide-field measurement mode |
225 mm × 125 mm 8.86" × 4.92" |
|
High-precision measurement mode |
206 mm × 106 mm 8.11" × 4.17" |
|||
Minimum display unit |
0.1 µm |
|||
Repeatability |
Inside camera's field of view (2σ) |
Wide-field measurement mode |
±0.5 µm |
|
High-precision measurement mode |
±0.1 µm |
|||
With stage movement |
X/Y axis |
±0.9 µm |
||
X/Y plane | ||||
Measurement accuracy |
Inside camera's field of view (2σ) |
Wide-field measurement mode |
±2 µm*1 |
|
High-precision measurement mode |
±0.7 µm*2 |
|||
With stage movement |
X/Y axis (EUX,MPE , EUY,MPE) |
±(1.8 + 0.02 L) µm*3 |
||
X/Y plane (EUXY,MPE) |
±(2.8 + 0.02 L) µm*3 |
|||
AF height measurement |
Repeatability |
±2 µm |
||
Measurement accuracy (EUZ,MPE) |
±(4.8 + 0.04 L) µm*4 |
|||
External remote input |
Non-voltage input (with and without contact) |
|||
External output |
OK/NG/FAIL/MEAS. |
PhotoMOS output |
||
Interface |
LAN |
RJ-45 (10BASE-T/100BASE-TX/1000BASE-T) |
||
USB 3.1 |
2 ports (rear: 2) |
|||
USB 2.0 Series A |
4 ports (front: 2, rear: 2) |
|||
Monitor output |
DVI-D |
|||
Record |
Hard disk drive |
500 GB |
||
Illumination system |
Transparent |
Telecentric transparent illumination |
||
Ring |
Four division, multi-angle illumination (electric) |
|||
External illumination control |
Intensity control |
PWM control, 100 kHz |
||
Output voltage |
12 V DC |
|||
Output current |
1.6 A (max.) |
|||
XY stage |
Moving range |
200 mm × 100 mm 7.87" × 3.94" (electric) |
||
Withstand load |
7 kg |
|||
Z stage |
Moving range |
75 mm 2.95" (electric) |
||
Power supply |
Power voltage |
100 to 240 V AC ±10% (50/60 Hz) |
||
Power consumption |
430 VA or lower |
|||
Environmental resistance |
Ambient temperature |
+10 to 35°C +50 to 95°F*5 |
||
Relative humidity |
20–80% RH (no condensation) |
|||
Overvoltage category |
ll |
|||
Pollution degree |
2 |
|||
Weight |
Approx. 30 kg |
|||
*1 In the range of 20 mm × 20 mm 0.79" × 0.79" within the operating ambient temperature range of +23°C ±1°C +73.4°F ±1.8°F at the focused focal point position. | ||||

Specifications
Model |
KV-CAL16 |
|||
Focal distance |
16 mm 0.63" |
|||
F-stop |
F1.6 to CLOSE |
|||
Minimum working distance |
0.4 m 1.3' |
|||
Supported cameras |
KV-CAC1H/KV-CAC1R |
|||

Specifications
Model |
FU-F38H |
|||
Type |
Definite-reflective model |
|||
Standard detection object |
Mirrored surface with a reflectivity of approximately 98% |
|||
Detection distance |
TERA |
0.3 to 2.3 mm 0.0118" to 0.0906"*1 |
||
MEGA | ||||
ULTRA |
0.3 to 2.2 mm 0.0118" to 0.0866"*1 |
|||
SUPER |
0.4 to 2.0 mm 0.0157" to 0.0787"*1 |
|||
TURBO |
0.5 to 1.8 mm 0.0197" to 0.0709"*1 |
|||
FINE |
0.6 to 1.6 mm 0.0236" to 0.0630"*1 |
|||
HSPD |
—*1 |
|||
S-HSPD | ||||
Minimum bend radius |
Fiber cable |
R4 mm R0.14" or more |
||
Film fiber |
No bending*2 |
|||
Tightening torque |
Tip detector/relay case |
4.3 cN•m (M1.6) |
||
Length |
Fiber cable |
Approx. 1000 mm 39.37" (free-cut) |
||
Film fiber |
Approx. 131 mm 5.16" |
|||
Environmental resistance |
Ambient temperature |
5°C to 60°C 41°F to 140°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Fiber cable |
Fiber coating: Polyethylene, Fiber core: Acrylic |
||
Relay case |
PC, SUS304 |
|||
Film fiber |
Polyimide, Special optical resin, SUS304 |
|||
Accessories |
Fiber cutter, FU adapter, Usage Precautions sheet |
|||
Weight |
Approx. 3 g |
|||
*1 Values are for FS-N40 Series devices with standard detectable objects. | ||||

Specifications
Model |
OP-88638 |
|||
Type |
2-axis adjustment mounting bracket (when illumination unit is used) |
|||
Weight |
Approx. 260 g |
|||

Specifications
Model |
FU-63T*1 |
|||
Beam emitting direction |
Top |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.3×2 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 10 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
OP-85584 |
|||
Overview |
This is a connector cable for the M8 connector sensor. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M8 connector sensor |
|||
Cable end |
M8 L-shaped connector - Loose wire |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 65 g |
|||