Specifications
Model |
OP-87415 |
|||
Applicable product |
SJ-E Series |
|||
Note |
Attaching this product to the SJ-E Series prevents bending. Attach this product at equal intervals. |
|||

Specifications
Model |
OP-94737 |
|||
Overview |
Connector cable with M12 on the both edges for connection. |
|||
Applicable product |
For extension of standard cables of connector sensors FD-P and FW. |
|||
Cable end |
M12 straight connector - M12 straight connector |
|||
Length |
1 m 3.28' |
|||

Specifications
Model |
TM-CX10U |
|||
Max. connections |
Number of steps |
2 |
||
Cable length |
30 m 98.4' total (10 m 32.8' between devices) |
|||
Environmental resistance |
Ambient temperature |
0 to +45°C 32 to 113°F |
||
Relative humidity |
35 to 85% (No condensation) |
|||
Weight |
Approx. 60 g |
|||


Specifications
Model |
GL-VM119FN |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
119 |
|||
Total length |
1200 mm 47.24" |
|||
Detection height |
1180 mm 46.46" |
|||
Protection height |
1204 mm 47.40" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
8.8 |
|
OFF→ON |
52.8 *3 |
|||
All blocked→ON |
65.3 *4 |
|||
With channel A or B |
ON→OFF |
29.0 |
||
OFF→ON |
82.5 *3 |
|||
All blocked→ON |
124.2 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
141 *5 |
||
Receiver |
156 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
63 *5 |
||
Receiver |
70 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
780 g 27.53 oz |
||
Receiver |
790 g 27.88 oz |
|||
Total |
1570 g 55.42 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
OP-87310 |
|||
Overview |
O-ring for conversion adapter female. |
|||
Applicable product |
GP-M adapter (G female) OP-87283 |
|||
Number included |
1 pcs. |
|||
Material |
FKM |
|||
Note |
Attached to the GP-M adapter (G female). |
|||

Specifications
Model |
CA-LMA4*1 |
|||
Type |
Coaxial |
|||
Optical magnification (reference magnification) |
x4 |
|||
Magnification range |
Approx. ±5 % relative to reference axis |
|||
WD (at reference magnification) |
70.3 mm 2.77" *2 |
|||
Compatible image sensor size |
1/2" |
|||
Field of view (at reference magnification) |
1/3" |
0.9 x 1.2 mm 0.035" x 0.047" |
||
1/2" |
1.2 x 1.6 mm 0.047" x 0.063" |
|||
2/3" |
- |
|||
F-stop range (aperture) |
26.5 |
|||
Depth-of-field |
172 µm 6.77 Mil*3 |
|||
Max. TV distortion |
-0.22 % |
|||
Resolution |
4.5 µm 0.18 Mil*4 |
|||
Mount |
C-mount |
|||
Ambient temperature/humidity range |
0 to +50 °C 32 to 122 °F, 80 % RH (No condensation) |
|||
Weight |
Approx. 66 g |
|||
*1 The above values are all calculated according to optical design values. Actual values for individual lenses will differ according to precision of assembly. | ||||


Specifications
Model |
CA-DEB10X |
|||
Light source |
Color |
Blue |
||
Control interface |
Connector |
Dedicated 12-pin circular connector |
||
Power source |
Supplies power via control interface |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC 60529) |
||
Ambient temperature |
0–40°C |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.05 G2/Hz, 0.5 hours in X/Y/Z directions (IEC 60068-2-64) |
|||
Shock resistance |
50 G in 6 directions, 3 times each (IEC 60068-2-27) |
|||
Size (H×W×D) |
116 mm × 116 mm × 53 mm |
|||
Standard certifications |
CE, FCC, NRTL, KC, UKCA |
|||
Material |
Main device case: Magnesium die-casting |
|||
Weight |
Approx. 390 g |
|||
*1 ESD-safe and IEC 61340-5-1-compliant when used with the OP-88808 (protective attachment for high-intensity smart ring lighting). | ||||



Specifications
Model |
NU-EP1 |
|||
Name |
Communication unit that supports EtherNet/IP™ |
|||
Ethernet |
Compliant standards |
IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-TX), IEEE802.3af (Power over Ethernet, Class 3) |
||
Transmission rate |
10 Mbps (10BASE-T), 100 Mbps (100BASE-TX) |
|||
Transmission media |
STP or category 3 or higher UTP (10BASE-T),*1 STP or category 5 or higher UTP (100BASE-TX) |
|||
Maximum cable length |
100 m 328.1' (the length between this unit and the Ethernet switch) |
|||
Max. number of connection stages |
4 (10BASE-T) 2 (100BASE-TX)*2 |
|||
EtherNet/IP™ |
Compliant functions |
Cyclic communication (implicit messages), message communication (explicit messages) |
||
Number of connections |
64 |
|||
RPI (Transmission cycle) |
0.5 to 10,000 ms (in units of 0.5 ms) |
|||
Tolerable communication bandwidth for cyclic communication |
6,000 pps |
|||
Message communication |
Supports UCMM, Class 3 |
|||
Conformance test |
Supports version A7 |
|||
Sensor connection |
Connectable sensors |
Sensor amplifier that supports N-bus*3 |
||
Number of connectable units |
16 maximum*4 |
|||
Power supply |
Power is supplied by this unit through the sensor amplifier connection connector. |
|||
Allowable passing current |
Total: 1,200 mA or less*5 |
|||
Power during PoE power receiving |
Supply voltage: 24 V ±10 %, supply current: 360 mA or less*6 (UL Class 2)*7 |
|||
Indicator lamp |
Link/activity indicator (LINK/ACT): green LED, module status indicator (MS): 2-color (green and red) LED, network status indicator (NS): 2-color (green and red) LED, sensor communication indicator (N-bus): 2-color (green and red) LED |
|||
Power voltage |
24 VDC ±10 %, ripple (P-P): 10 % or less (when using the power supply connector); 48 VDC (57 V maximum; during PoE power receiving) |
|||
Power consumption |
1,500 mW or less (60 mA or less at 24 V)*8 |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit case and dust cover: polycarbonate, power supply connector: polyamide (plug), PBT (socket) |
|||
Accessories |
Instruction manual, power supply connection connector, end unit x 2 |
|||
Weight |
Approx. 80 g (including connectors) |
|||
*1 When using the PoE power receiving function to form a connection, use an STP cable or category 5 or higher UTP cable. | ||||

Specifications
Model |
OP-89130 |
|||
Type |
High-flex *1 *2 |
|||
Sensor side |
Connector size |
M8 3-pin |
||
Appearance |
Straight |
|||
Cable connector |
Connector size |
M12 4-pin |
||
Appearance |
Straight |
|||
Length |
10 m 32.8' |
|||
Material |
Cable: PVC, |
|||
Weight |
Approx. 270 g |
|||
*1 Use a heat/cleaning-resistant cable for the weld-resistant all-metal type in environments of 80°C 176°F or higher and for the environment-resistant all-metal type in environments of -25°C -13°F or lower or at 80°C 176°F or higher. | ||||

Specifications
Model |
LV-L02 |
|||
Type |
Lens attachment for the LV-NH47/LV-H47 |
|||
Area width |
Standard mode |
Detecting distance at 55 mm 2.17": 17 mm 0.67" |
||
When slit 1 is equipped |
Detecting distance at 55 mm 2.17": 13.0 mm 0.51" |
|||
When slit 2 is equipped |
Detecting distance at 55 mm 2.17": 11.0 mm 0.43" |
|||
When slit 3 is equipped |
Detecting distance at 55 mm 2.17": 8.5 mm 0.33" |
|||
When slit 4 is equipped |
Detecting distance at 55 mm 2.17": 6.0 mm 0.24" |
|||
Area thickness |
Detecting distance at 55 mm 2.17": 3.0 mm 0.12" |
|||
Material |
Case |
Polyacetal (main body), Arton (lens) |
||
Weight |
Approx. 1 g |
|||

Specifications
Model |
OP-87445 |
|||
Type |
Panel power cable |
|||
Cable end |
M8 4-pin - strand wire |
|||
Length |
10 m 32.8' |
|||

Specifications
Model |
PR-FB15C3PL*1 |
|||
Type |
Reflective (Background suppression) |
|||
Output |
PNP |
|||
Shape |
Flat |
|||
Cable connection |
M8 connector (3 pin) |
|||
Detection distance |
1 to 15 mm 0.04" to 0.59" |
|||
Number of control outputs |
1 output |
|||
Output operation |
Output 1 |
- |
||
Output 2 |
Light-ON |
|||
Response time |
Output 1 |
- |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. 2.5 x 4.5 mm (at 15 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including 10 % ripple (P-P) |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 10 g |
|||
*1 The M8 connector (3 pin) type has 1 control output. If "D" is at the end of the part number, the sensor is equipped with a Dark-ON output. If "L" is at the end of the part number, the sensor is equipped with a Light-ON output. Example: The PR-M51C3PL has a Light-ON output. | ||||


Specifications
Model |
FR-LP20L |
|||
Type |
Long range Chemical model |
|||
Measuring range |
Up to 15 m 49.2'*1 |
|||
Display range |
Up to 25 m 82.0'*1 |
|||
Measurable dielectric constant of medium |
2 or higher*2 |
|||
Resolution |
1 mm 0.04" |
|||
Precision |
Up to 0.1 m 0.3': ±10 mm 0.39"; |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||
Tank pressure |
-0.1 to +0.1 Mpa |
|||
Material |
Tank interior |
Lens: PTFE |
||
Housing |
PPS PPSU |
|||
Connection diameter |
G1-1/2 (40 A) |
|||
Output |
No. of control outputs |
Maximum 5 |
||
Control output/auxiliary output |
NPN/PNP open collector (switching type) |
|||
Analog output |
0–20 mA/4–20 mA maximum load resistance 260 Ω |
|||
External input |
─ |
|||
Network compatibility |
IO-Link v1.1/COM2 |
|||
Analog output accuracy |
Resolution |
1 mm 0.04"*4 |
||
Zero accuracy |
±0.1 mA (zero point = 4 mA)*4 |
|||
F.S. accuracy |
±0.2 mA (full-scale = 20 mA)*4 |
|||
Power supply |
Power voltage |
24 VDC + 25%/–20% |
||
Power consumption |
98 mA or less (Excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
Display part when combined and separated: –10 to +50°C 14°F to 122°F (no freezing)*5*6 |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Temperature of coupling used |
–10 to +85°C 14°F to 185°F (no freezing)*5*6 |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Enclosure rating |
IP67 (IEC60529), Enclosure Type 4X (NEMA250) |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||
Weight |
Approx. 400 g 14.11 oz |
|||
*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened. | ||||

Specifications
Model |
CV-200M |
|||
Type |
Camera*1 |
|||
Image element |
1/1.8-inch monochrome CCD image receiving element, square-pixel/all-pixel reading, 2,010,000 pixels |
|||
Valid pixel count |
1,920,000 pixels 1600 (H) x 1200 (V) *2 |
|||
Pixel transfer frequency |
40 MHz |
|||
Scanning system |
Progressive (58.5 ms: 2,000,000-pixel mode, 47.6 ms: 1,000,000-pixel mode) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values. |
|||
Lens mount |
C mount |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 110 g (not including lens) |
|||
*1 The CA-CN17 camera cable (17 m 55.8') and the CA-CN17R high-flex camera cable (17 m 55.8') cannot be used. | ||||

Specifications
Model |
FU-35A |
|||
Detecting method |
Diffuse Reflective |
|||
Size |
M3 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
0.5 m |
|||
Shape |
Straight |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Detection distance |
20 mm0.787"*1 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 The detecting distance is a value for white mat paper (the standard detection object) detections. | ||||