PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AS-440-02U |
|||
Type |
General-use amplifier unit |
|||
Sensor head |
AH-110 |
|||
Shape |
M10 threaded |
|||
Measuring range |
0 to 2mm0.08" |
|||
Analog output voltage |
Output voltage |
0 to 2V |
||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F, No freezing |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 55g |
||
Weight (including cord) |
Amplifier unit |
Approx 320g |
||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AS-440-05U |
|||
Type |
General-use amplifier unit |
|||
Sensor head |
AH-416 |
|||
Shape |
Cylindrical and threaded, diameter: 14.5 |
|||
Measuring range |
0 to 5 mm 0.20" |
|||
Analog output voltage |
Output voltage |
0 to 5 V |
||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F, No freezing |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 75 g |
||
Weight (including cord) |
Amplifier unit |
Approx 320g |
||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AS-440-10U |
|||
Type |
General-use amplifier unit |
|||
Sensor head |
AH-422 |
|||
Shape |
Cylindrical and threaded, diameter: 22 |
|||
Measuring range |
0 to 10 mm0" to 0.394" |
|||
Analog output voltage |
Output voltage |
0 to 10 V |
||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F, No freezing |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 200g |
||
Weight (including cord) |
Amplifier unit |
Approx 320g |
||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||




PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.




PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
BC-1000 |
|||
Camera |
High resolution |
5472 × 3648 |
||
CMOS |
20 megapixels |
|||
Counting |
Measurement area |
ø105 mm ø4.13" |
||
Supported samples |
Petri dishes, well plates, and culture film |
|||
Observation |
Front camera |
Included (with variable tilting and support for 2D codes) |
||
Lighting type |
Automatic variable illumination |
|||
Lens |
Proprietary high-resolution lens |
|||
Image format |
JPEG, TIFF |
|||
Recording |
Output format |
Excel, PDF, CSV |
||
Operation |
Center console |
Included |
||
Dimensions |
Outer dimensions |
364 × 518 × 615 mm 14.33"×20.39"×24.21" |
||
Software |
Supported OS |
Windows 11, Windows 10 |
||
Power supply |
Power voltage |
100 to 240 VAC ±10%, 50/60 Hz |
||
Power consumption |
240 VA |
|||
Environmental resistance |
Ambient temperature |
+15°C to 35°C +59°F to 95°F |
||
Relative humidity |
35% to 80% RH (no condensation) |
|||
Weight |
23 kg 50.71 lb (Main unit) |
|||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.