Specifications
Model |
AP-C31K |
|||
Type |
Negative pressure, NPN |
|||
Rated pressure |
0 to -29.9 inchHg |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Display resolution |
Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less |
||
Eco mode |
12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of F.S.)*1 |
|||
Response time (Chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Pressure port |
NPT 1/8 180 ° rotation |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Pressure resistance |
500 kPa |
||
Ambient temperature |
0 to 50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting |
|||
Accessories |
Power supply cord (6.6' 2-m with connector) |
|||
Weight |
Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable) |
|||
*1 A standard of 0.2 % of FS applies while in focus mode. | ||||

Specifications
Model |
AP-C31KP |
|||
Type |
Negative pressure, PNP |
|||
Rated pressure |
0 to -29.9 inchHg |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Display resolution |
Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 900 mW (75 mA) or less, 24 V: 1,320 mW (55 mA) or less |
||
Eco mode |
12 V: 600 mW (50 mA) or less, 24 V: 960 mW (40 mA) or less |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of F.S.)*1 |
|||
Response time (Chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
PNP open collector 100 mA max. (at 30 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Pressure port |
NPT 1/8 180 ° rotation |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Pressure resistance |
500 kPa |
||
Ambient temperature |
0 to 50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting |
|||
Accessories |
Power supply cord (6.6' 2-m with connector) |
|||
Weight |
Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable) |
|||
*1 A standard of 0.2 % of FS applies while in focus mode. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-C33K |
|||
Type |
Positive pressure, NPN |
|||
Rated pressure |
0 to 145.0 Psi |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Display resolution |
Normal mode: 0.2 Psi, Focus mode: 0.02 Psi |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less |
||
Eco mode |
12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of F.S.)*1 |
|||
Response time (Chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Pressure port |
NPT 1/8 180 ° rotation |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Pressure resistance |
1.5 MPa |
||
Ambient temperature |
0 to 50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting |
|||
Accessories |
Power supply cord (6.6' 2-m with connector), Unit seal |
|||
Weight |
Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable) |
|||
*1 A standard of 0.2 % of FS applies while in focus mode. | ||||

Specifications
Model |
AP-C33KP |
|||
Type |
Positive pressure, PNP |
|||
Rated pressure |
0 to 145.0 Psi |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Display resolution |
Normal mode: 0.2 Psi, Focus mode: 0.02 Psi |
|||
Power consumption |
Normal |
12 V: 900 mW (75 mA) or less, 24 V: 1,320 mW (55 mA) or less |
||
Eco mode |
12 V: 600 mW (50 mA) or less, 24 V: 960 mW (40 mA) or less |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of F.S.)*1 |
|||
Response time (Chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
PNP open collector 100 mA max. (at 30 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Pressure port |
NPT 1/8 180 ° rotation |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Pressure resistance |
1.5 MPa |
||
Ambient temperature |
0 to 50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting |
|||
Accessories |
Power supply cord (6.6' 2-m with connector), Unit seal |
|||
Weight |
Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable) |
|||
*1 A standard of 0.2 % of FS applies while in focus mode. | ||||






PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-C40W |
|||
Type |
Amplifier Unit, NPN |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Set and display range |
-15 to +110 % of F.S.*1 |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 780 mW (65 mA) max., 24 V: 1,080 mW (45 mA) max. |
||
Eco mode |
12 V: 540 mW (45 mA) max., 24 V: 840 mW (35 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) |
|||
Response time (Chattering prevention function) |
1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 100 mA max. (at 40 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate |
|||
Accessories |
Power supply code (2-m 6.6' cable with connector), Head connector, and Unit seal |
|||
Weight |
Approx. 74 g (with 2-m 6.6' cable) |
|||
*1 The focus range applies while in focus mode only. | ||||

Specifications
Model |
AP-C40WP |
|||
Type |
Amplifier Unit, PNP |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Set and display range |
-15 to +110 % of F.S.*1 |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 960 mW (80 mA) max., 24 V: 1,400 mW (60 mA) max. |
||
Eco mode |
12 V: 660 mW (55 mA) max., 24 V: 1,080 mW (45 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) |
|||
Response time (Chattering prevention function) |
1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
PNP open collector 100 mA max. (at 30 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate |
|||
Accessories |
Power supply code (2-m 6.6' cable with connector), Head connector, and Unit seal |
|||
Weight |
Approx. 74 g (with 2-m 6.6' cable) |
|||
*1 The focus range applies while in focus mode only. | ||||

Specifications
Model |
AP-N10 |
|||
Type |
Single output type |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44, AP-48 |
|||
Configuration/Display range |
-15 to +110 % of F.S. |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa |
|||
Power consumption |
Normal |
770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less) |
||
Eco mode |
560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less) |
|||
Expansion units |
Max. 16 units (Dual output type is counted as 2 units.)*1 |
|||
Control output(s) |
1*2 |
|||
Display temperature characteristic |
±1 % of F.S. (When the temperature varies from 25 °C 77 °F) |
|||
Response time (Chattering prevention function) |
1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2 |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing)*3 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Material |
Main unit and cover: Polycarbonate |
|||
Weight |
Approx. 20 g |
|||
*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers. | ||||

Specifications
Model |
AP-N10D |
|||
Type |
Dual output type |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44, AP-48 |
|||
Configuration/Display range |
-15 to +110 % of F.S. |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa |
|||
Power consumption |
Normal |
770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less) |
||
Eco mode |
560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less) |
|||
Expansion units |
Max. 16 units (Dual output type is counted as 2 units.)*1 |
|||
Control output(s) |
2*2 |
|||
Display temperature characteristic |
±1 % of F.S. (When the temperature varies from 25 °C 77 °F) |
|||
Response time (Chattering prevention function) |
1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2 |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing)*3 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Material |
Main unit and cover: Polycarbonate |
|||
Weight |
Approx. 20 g |
|||
*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-V41AW |
|||
Type |
Amplifier Unit, NPN |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Set and display range |
-15 to +110 % of F.S.*1 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green), Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
||
Eco mode |
12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) |
|||
Response time (Chattering prevention function) |
1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 100 mA max. (at 40 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
Mounting bracket, Head connector |
|||
Weight |
Approx. 80 g (with 2-m 6.6' cable) |
|||
*1 The focus range applies while in focus mode only. | ||||

Specifications
Model |
AP-V41AWP |
|||
Type |
Amplifier Unit, PNP |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Set and display range |
-15 to +110 % of F.S.*1 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green), Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
||
Eco mode |
12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) |
|||
Response time (Chattering prevention function) |
1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
PNP open collector 100 mA max. (at 30 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
Mounting bracket, Head connector |
|||
Weight |
Approx. 80 g (with 2-m 6.6' cable) |
|||
*1 The focus range applies while in focus mode only. | ||||

Specifications
Model |
AP-V41W |
|||
Type |
Amplifier Unit, NPN |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED × 2 (corresponding to control output 1 and control output 2) |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
||
Eco mode |
12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. or less |
|||
Hysteresis |
Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable |
|||
Response time (Chattering prevention function) |
1/2.5/5/100/500 ms (selectable; 1 ms is used when high-speed mode is selected) |
|||
I/O |
Analog output |
1 to 5 V, output impedance: 1 kΩ or less (switchable with zero shift input) |
||
Zero-shift input |
Input time: 2 ms or more (switchable with analog output) |
|||
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)*1 |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
Mounting bracket, head connection connector |
|||
Weight |
Approx. 80 g (with 2 m cable) |
|||
*1 20 mA or less when extended | ||||

Specifications
Model |
AP-V41WP |
|||
Type |
Amplifier Unit, PNP |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED × 2 (corresponding to control output 1 and control output 2) |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 840 mW (70 mA) max., 24 V: 1,200 mW (50 mA) max. |
||
Eco mode |
12 V: 600 mW (50 mA) max., 24 V: 960 mW (40 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. or less |
|||
Hysteresis |
Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable |
|||
Response time (Chattering prevention function) |
1/2.5/5/100/500 ms (selectable; 1 ms is used when high-speed mode is selected) |
|||
I/O |
Analog output |
1 to 5 V, output impedance: 1 kΩ or less (switchable with zero shift input) |
||
Zero-shift input |
Input time: 2 ms or more (switchable with analog output) |
|||
Control output |
Maximum PNP open-collector output: 100 mA (30 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)*1 |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
Mounting bracket, head connection connector |
|||
Weight |
Approx. 80 g (with 2 m cable) |
|||
*1 20 mA or less when extended | ||||