Servo Drives

13938 products

Showing 25 - 48 of 13938 products

Showing 25 - 48 of 13938 products
View
ATV71HD30N4 Schneider
Schneider ATV71HD30N4 Schneider
Sale price €2.132,95
In stock, 11 units

Main

Characteristic Value(s)
Range of Product Altivar 71
Product or Component Type Variable speed drive
Product Specific Application Complex, high-power machines
Component name ATV71
Motor power kW 30 kW, 3 phase 380...480 V
Maximum Horse Power Rating 40 hp, 3 phase 380...480 V
Maximum motor cable length 328.08 ft (100 m) shielded cable
656.2 ft (200 m) unshielded cable
power supply voltage 380...480 V - 15...10 %
Phase 3 phase
Line current 56 A 480 V 3 phase 30 kW / 40 hp
66 A 380 V 3 phase 30 kW / 40 hp
EMC filter Integrated
Assembly style With heat sink
Apparent power 43.4 kVA 380 V 3 phase 30 kW / 40 hp
Prospective line Isc 22 kA 3 phase
Nominal output current 52 A 4 kHz 460 V 3 phase 30 kW / 40 hp
66 A 4 kHz 380 V 3 phase 30 kW / 40 hp
Maximum transient current 109 A 2 s 3 phase 30 kW / 40 hp
99 A 60 s 3 phase 30 kW / 40 hp
Output frequency 0.1…599 Hz
Nominal switching frequency 4 kHz
Switching frequency 1...16 kHz adjustable
4...16 kHz with derating factor
Asynchronous motor control profile Sensorless flux vector control (SFVC) (voltage or current vector)
Voltage/frequency ratio (2 or 5 points)
Flux vector control (FVC) with sensor (current vector)
ENA (Energy adaptation) system for unbalanced loads
Type of polarization No impedance Modbus

Complementary

Characteristic Value(s)
Product destination Asynchronous motors
Synchronous motors
power supply voltage limits 323…528 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Speed range 1…100 asynchronous motor in open-loop mode, without speed feedback
1…1000 asynchronous motor in closed-loop mode with encoder feedback
1…50 synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn
+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
+/- 5 % in closed-loop mode with encoder feedback
Transient overtorque 170 % +/- 10 % 60 s every 10 minutes
220 % +/- 10 % 2 s
Braking torque <= 150 % with braking or hoist resistor
30 % without braking resistor
Synchronous motor control profile Vector control without speed feedback
Regulation loop Adjustable PI regulator
Motor slip compensation Suppressable
Adjustable
Not available in voltage/frequency ratio (2 or 5 points)
Automatic whatever the load
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
Insulation Electrical between power and control
type of cable for mounting in an enclosure With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal 50 mm², AWG 1/0 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
106.2 lbf.in (12 N.m), 102.2 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign
AI2 software-configurable current 0...20 mA 242 Ohm 11 bits
AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
input sampling time 2 ms +/- 0.5 ms AI1-/Al1+) - analog
2 ms +/- 0.5 ms Al2) - analog
2 ms +/- 0.5 ms LI1...LI5) - discrete
2 ms +/- 0.5 ms LI6)if configured as logic input - discrete
Response time <= 100 ms in STO (Safe Torque Off)
AO1 2 ms +/- 0.5 ms analog
R1A, R1B, R1C 7 ms +/- 0.5 ms discrete
R2A, R2B 7 ms +/- 0.5 ms discrete
absolute accuracy precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % AI2) for a temperature variation 60 °C
+/- 1 % AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value AI1-/Al1+, AI2)
+/- 0.2 % AO1)
Analogue output number 1
Analogue output type AO1 software-configurable logic output 10 V 20 mA
AO1 software-configurable current 0...20 mA 500 Ohm 10 bits
AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic R2A, R2B) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current R1, R2 2 A 250 V AC inductive, cos phi = 0.4
R1, R2 2 A 30 V DC inductive, cos phi = 0.4
R1, R2 5 A 250 V AC resistive, cos phi = 1
R1, R2 5 A 30 V DC resistive, cos phi = 1
Discrete input number 7
Discrete input type LI1...LI5 programmable 24 V DC level 1 PLC 3500 Ohm
LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm
LI6 switch-configurable PTC probe 0…6 1500 Ohm
PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d
Discrete input logic Negative logic (sink) LI1...LI5), > 16 V, < 10 V
Positive logic (source) LI1...LI5), < 5 V, > 11 V
Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V
Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
S, U or customized
Braking to standstill By DC injection
Protection type Against exceeding limit speed drive
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Short-circuit between motor phases drive
Thermal protection drive
Motor phase break motor
Power removal motor
Thermal protection motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Communication Port Protocol Modbus
CANopen
Connector type 1 RJ45 on front face)Modbus
1 RJ45 on terminal)Modbus
Male SUB-D 9 on RJ45CANopen
Physical interface 2-wire RS 485 Modbus
Transmission frame RTU Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
9600 bps, 19200 bps Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format 8 bits, 1 stop, even parity Modbus on front face
8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses 1…127 CANopen
1…247 Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Height 21.7 in (550 mm)
Depth 10.5 in (266 mm)
Width 9.4 in (240 mm)
Product Weight 81.6 lb(US) (37 kg)
Functionality Full
Specific application Other applications
Option card Communication card CC-Link
Controller inside programmable card
Communication card DeviceNet
Communication card EtherNet/IP
Communication card Fipio
I/O extension card
Communication card Interbus-S
Interface card for encoder
Communication card Modbus Plus
Communication card Modbus TCP
Communication card Modbus/Uni-Telway
Overhead crane card
Communication card Profibus DP
Communication card Profibus DP V1
ATV61HD30N4 Schneider
Schneider ATV61HD30N4 Schneider
Sale price €2.568,95
Only 6 units left

Variable Speed Drive Altivar 61 - 30kW 40hp 480V 3 Phases EMC IP20 with Graphic Terminal

ATV312HU55N4 Schneider
Schneider ATV312HU55N4 Schneider
Sale price €1.064,95
In stock, 17 units

Variable Speed Drive Altivar ATV312 - 5.5kW - 15kVA - 232W - 380..500 V - 3-Phase Supply

ATV630D11N4 Schneider Electric
Schneider ATV630D11N4 Schneider Electric
Sale price €821,95
Only 9 units left

Variable Speed Drive ATV630 - 11kW/15hp - 380...480V - IP21/UL type 1

ATV12H075M2 Schneider
Schneider ATV12H075M2 Schneider
Sale price €153,95
Only 5 units left

Variable Speed Drive Altivar ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with Heat Sink

ATV630U75N4 Schneider
Schneider ATV630U75N4 Schneider
Sale price €768,95
Only 5 units left

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 7.5kW / 10hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 5.5kW / 7.5hp for applications requiring significant overload (up to 150%). It weighs 7.7kg and its dimensions are, 171mm wide, 409mm high, 233mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV600
Product Specific Application Process and utilities
Product or Component Type Variable speed drive
Variant Standard version
Device short name ATV630
Mounting Mode Wall mount
Communication Port Protocol Ethernet
Modbus serial
Modbus TCP
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 16.5 A
IP degree of protection IP21
Product destination Asynchronous motors
Synchronous motors
EMC filter Integrated 164.04 ft (50 m) IEC 61800-3 category C2
Integrated 492.1 ft (150 m) IEC 61800-3 category C3
IP degree of protection IP21IEC 61800-5-1
IP21IEC 60529
Degree of protection UL type 1 UL 508C
type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
Motor power kW 7.5 kW normal duty)
5.5 kW heavy duty)
Maximum Horse Power Rating 10 hp normal duty
7.5 hp heavy duty
Line current 13.8 A 380 V normal duty)
11.9 A 480 V normal duty)
10.5 A 380 V heavy duty)
9.2 A 480 V heavy duty)
Continuous output current 16.5 A 4 kHz normal duty
12.7 A 4 kHz heavy duty
Speed drive output frequency 0.1…500 Hz
Safety function STO (safe torque off) SIL 3
Option card Slot A communication module, Profibus DP V1
Slot A communication module, PROFINET
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/EtherNet/IP
Slot A communication module, CANopen daisy chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw terminals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A communication module, Ethernet IP/Modbus TCP/MD-Link
communication module, BACnet MS/TP
communication module, Ethernet Powerlink

Complementary

Characteristic Value(s)
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
Discrete input logic 16 preset speeds
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 10 bits
Software-configurable current DQ-, DQ+ 30 V DC
Software-configurable current DQ-, DQ+ 100 mA
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
Maximum switching current Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Phase 3 phase
Physical interface Ethernet
2-wire RS 485
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frame RTU
Output voltage <= power supply voltage
Permissible temporary current boost 1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Frequency resolution Display unit 0.1 Hz
Analog input 0.012/50 Hz
Electrical connection Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Motor screw terminal 6...10 mm² AWG 10...AWG 8
Line side screw terminal 4...6 mm² AWG 12...AWG10
Connector type RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling 3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Input compatibility DI1...DI6 discrete input level 1 PLC IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI4) - discrete input
5 ms +/- 1 ms DI5, DI6) - discrete input
5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete and process manufacturing Building - HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Power range 7…11 kW 380…440 V 3 phase
7…11 kW 480…500 V 3 phase
Enclosure mounting Wall mounted
4 quadrant operation possible False
Asynchronous motor control profile Variable torque standard
Optimized torque mode
Constant torque standard
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 500 kHz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Not available in permanent magnet motor law
Can be suppressed
Automatic whatever the load
Adjustable
Switching frequency 2...12 kHz adjustable
4...12 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated False
Maximum Input Current per Phase 13.8 A
Maximum output voltage 480.0 V
Apparent power 9.9 kVA 480 V normal duty)
7.6 kVA 480 V heavy duty)
Maximum transient current 18.2 A 60 s normal duty)
19.1 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 12.7 A
Base load current at low overload 16.5 A
Power dissipation in W Natural convection 172 W 380 V 4 kHz
Forced convection 44 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) False
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) False
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 6.7 in (171 mm)
Height 16.1 in (409 mm)
Depth 9.2 in (233 mm)
Product Weight 17.0 lb(US) (7.7 kg)
ATV312HU22N4 Schneider
Schneider ATV312HU22N4 Schneider
Sale price €508,95
In stock, 14 units

Altivar ATV312 variable frequency drives (VFD) provide a compact, cost effective adjustable speed control for asynchronous motors from 0.25 to 20 HP. It is suitable for industrial machines such as materials handling and packaging, packing, textile machines, special machines, pumps and fans. It has a compact form-factor with 142mm width, allowing for a flexible and easy installation on a mounting plate. It also offers a snap-lock seal, status and faults display, a jog dial navigation button and an integrated EMC filter. It offers high readability of key parameters thanks to a bright LED 4-digit display. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime.

Main

Characteristic Value(s)
Range of Product Altivar 312
Product or Component Type Variable speed drive
Product destination Asynchronous motors
Product Specific Application Simple machine
Assembly style With heat sink
Component name ATV312
Motor power kW 2.2 kW
Maximum Horse Power Rating 3 hp
[Us] rated supply voltage 380...500 V - 15...10 %
Supply frequency 50...60 Hz - 5...5 %
Phase 3 phase
Line current 8.9 A 380 V, Isc = 5 kA
6.7 A 500 V
EMC filter Integrated
Apparent power 5.9 kVA
Maximum transient current 8.3 A 60 s
Power dissipation in W 79 W at nominal load
Speed range 1…50
Asynchronous motor control profile Sensorless flux vector control with PWM type motor control signal
Factory set : constant torque
Electrical connection Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 0.004 in² (2.5 mm²) AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.008 in² (5 mm²) AWG 10
Supply Internal supply for logic inputs 19...30 V 100 mA overload and short-circuit protection
Internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V 10 mA overload and short-circuit protection
Communication Port Protocol CANopen
Modbus
IP degree of protection IP20 on upper part without cover plate
IP21 on connection terminals
IP31 on upper part
IP41 on upper part
Option card Communication card CANopen daisy chain
Communication card DeviceNet
Communication card Fipio
Communication card Modbus TCP
Communication card Profibus DP

Complementary

Characteristic Value(s)
Supply voltage limits 323…550 V
Prospective line Isc 5 kA
Continuous output current 5.5 A 4 kHz
Output frequency 0…500 Hz
Nominal switching frequency 4 kHz
Switching frequency 2...16 kHz adjustable
Transient overtorque 170…200 % of nominal motor torque
Braking torque 150 % 60 s with braking resistor
100 % with braking resistor continuously
150 % without braking resistor
Regulation loop Frequency PI regulator
Motor slip compensation Automatic whatever the load
Adjustable
Suppressable
Output voltage <= power supply voltage
Tightening torque Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 5.3 lbf.in (0.6 N.m)
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 10.6 lbf.in (1.2 N.m)
Insulation Electrical between power and control
Analogue input number 3
Analogue input type AI1 configurable voltage 0...10 V 30 V max 30000 Ohm
AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm
AI3 configurable current 0...20 mA 250 Ohm
Sampling duration AI1, AI2, AI3 8 ms analog
LI1...LI6 4 ms discrete
Response time AOV, AOC 8 ms analog
R1A, R1B, R1C, R2A, R2B 8 ms discrete
Linearity error +/- 0.2 % output
Analogue output number 1
Analogue output type AOC configurable current 0...20 mA 800 Ohm 8 bits
AOV configurable voltage 0...10 V 470 Ohm 8 bits
Discrete input logic Logic input not wired LI1...LI4), < 13 V
Negative logic (source) LI1...LI6), > 19 V
Positive logic (source) LI1...LI6), < 5 V, > 11 V
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
Configurable relay logic R2A, R2B) NC - 100000 cycles
Minimum switching current R1-R2 10 mA 5 V DC
Maximum switching current R1-R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms
R1-R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms
R1-R2 5 A 250 V AC resistive, cos phi = 1 0 ms
R1-R2 5 A 30 V DC resistive, cos phi = 1 0 ms
Discrete input number 6
Discrete input type LI1...LI6) programmable 24 V, 0…100 mA PLC 3500 Ohm
Acceleration and deceleration ramps S, U or customized
Linear adjustable separately from 0.1 to 999.9 s
Braking to standstill By DC injection
Protection type Input phase breaks drive
Line supply overvoltage and undervoltage safety circuits drive
Line supply phase loss safety function, for three phases supply drive
Motor phase breaks drive
Overcurrent between output phases and earth (on power up only) drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection motor
Insulation resistance >= 500 mOhm 500 V DC for 1 minute
Local signalling 1 LED (red) for drive voltage
Four 7-segment display units for CANopen bus status
Time constant 5 ms for reference change
Frequency resolution Analog input 0.1...100 Hz
Display unit 0.1 Hz
Connector type 1 RJ45 Modbus/CANopen
Physical interface RS485 multidrop serial link
Transmission frame RTU
Transmission Rate 10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen
4800, 9600 or 19200 bps Modbus
Number of addresses 1…127 CANopen
1…247 Modbus
Number of drive 127 CANopen
31 Modbus
Marking CE
Operating position Vertical +/- 10 degree
Outer dimension 402 x 239 x 192 mm
184 x 140 x 150 mm
215 x 185 x 158 mm
Height 7.2 in (184 mm)
Width 5.6 in (142 mm)
Depth 6.0 in (152 mm)
Product Weight 6.8 lb(US) (3.1 kg)
ATV630D55N4 Schneider Electric
Schneider ATV630D55N4 Schneider Electric
Sale price €2.711,95
In stock, 11 units

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 55kW / 75hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 45kW / 60hp for applications requiring significant overload (up to 150%). It weighs 56.5kg and its dimensions are, 290mm wide, 922mm high, 323mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV600
Product Specific Application Process and utilities
Product or Component Type Variable speed drive
Variant Standard version
Device short name ATV630
Mounting Mode Wall mount
Communication Port Protocol Ethernet
Modbus serial
Modbus TCP
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 106.0 A
IP degree of protection IP21
Product destination Asynchronous motors
Synchronous motors
EMC filter Integrated 492.1 ft (150 m) IEC 61800-3 category C3
IP degree of protection IP21IEC 61800-5-1
IP21IEC 60529
Degree of protection UL type 1 UL 508C
type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
Motor power kW 55 kW normal duty)
45 kW heavy duty)
Maximum Horse Power Rating 75 hp normal duty
60 hp heavy duty
Line current 97.2 A 380 V normal duty)
84.2 A 480 V normal duty)
81.4 A 380 V heavy duty)
71.8 A 480 V heavy duty)
Continuous output current 106 A 2.5 kHz normal duty
88 A 2.5 kHz heavy duty
Speed drive output frequency 0.1…500 Hz
Safety function STO (safe torque off) SIL 3
Option card Slot A communication module, Profibus DP V1
Slot A communication module, PROFINET
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/EtherNet/IP
Slot A communication module, CANopen daisy chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw terminals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A communication module, Ethernet IP/Modbus TCP/MD-Link
communication module, BACnet MS/TP
communication module, Ethernet Powerlink

Complementary

Characteristic Value(s)
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
Discrete input logic 16 preset speeds
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 10 bits
Software-configurable current DQ-, DQ+ 30 V DC
Software-configurable current DQ-, DQ+ 100 mA
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
Maximum switching current Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Phase 3 phase
Physical interface Ethernet
2-wire RS 485
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frame RTU
Output voltage <= power supply voltage
Permissible temporary current boost 1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Frequency resolution Display unit 0.1 Hz
Analog input 0.012/50 Hz
Electrical connection Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 70...120 mm² AWG 1/0...250 kcmil
Motor screw terminal 70...120 mm² AWG 1/0...250 kcmil
Connector type RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling 3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Input compatibility DI1...DI6 discrete input level 1 PLC IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI4) - discrete input
5 ms +/- 1 ms DI5, DI6) - discrete input
5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete and process manufacturing Building - HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Power range 55…100 kW 380…440 V 3 phase
55…100 kW 480…500 V 3 phase
Enclosure mounting Wall mounted
4 quadrant operation possible False
Asynchronous motor control profile Constant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 500 kHz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Not available in permanent magnet motor law
Can be suppressed
Automatic whatever the load
Adjustable
Switching frequency 2.5...8 kHz with derating factor
2...8 kHz adjustable
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated False
Maximum Input Current per Phase 97.2 A
Maximum output voltage 480.0 V
Apparent power 70 kVA 480 V normal duty)
59.7 kVA 480 V heavy duty)
Maximum transient current 116.6 A 60 s normal duty)
132 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 88.0 A
Base load current at low overload 106.0 A
Power dissipation in W Natural convection 131 W 380 V 2.5 kHz
Forced convection 917 W 380 V 2.5 kHz
With safety function Safely Limited Speed (SLS) False
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) False
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 11.4 in (290 mm)
Height 36.3 in (922 mm)
Depth 12.7 in (323 mm)
Product Weight 124.6 lb(US) (56.5 kg)
ATV320U22N4C Schneider
Schneider ATV320U22N4C Schneider
Sale price €289,95
Only 8 units left

This Altivar 320 variable speed drive can feed 3-phase synchronous and asynchronous motors. Its compact form factor allows vertical stacking of drives inside machine frames. It works at a rated power up to 2.2kW / 3hp and a rated voltage from 380V to 500V AC. Its robust design with IEC 60721-3-3 class 3C3 coated printed circuit boards allows to extend machine availability in harsh environmental conditions, for example at ambient temperatures of up to 60°C without the need of additional cooling. It incorporates functions suitable for the most common applications, including torque and speed accuracy at very low speed, high dynamic performance with flux vector control without sensor and extended frequency range for high-speed motors. It also incorporates parallel connection of motors and special drives using the voltage/frequency ratio and static speed accuracy and energy saving for open-loop synchronous motors. The drive software includes 5 safety functions that help machines meet safety requirements, whether or not they are used in conjunction with a Preventa safety module. These safety functions are configured using SoMove software. Altivar Machine ATV320 was designed for Original Equipment Manufacturers (OEMs) that meets simple and advanced application requirements covered for packaging, material handling, textile, material working, mechanical actuators and hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, NOM, EAC and RCM certified. Mounting accessories and external options (braking resistors, line chokes, motor chokes, additional EMC filters) are available with Altivar Machine ATV320 drives. The type of external accessories and options depends on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV320 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Main

Characteristic Value(s)
Range of Product Altivar Machine ATV320
Product or Component Type Variable speed drive
Product Specific Application Complex machines
Variant Standard version
With disconnect switch
Format of the drive Compact
Mounting Mode Wall mount
Communication Port Protocol Modbus serial
CANopen
Option card communication module, CANopen
communication module, EtherCAT
communication module, Profibus DP V1
communication module, PROFINET
communication module, Ethernet Powerlink
communication module, EtherNet/IP
communication module, DeviceNet
[Us] rated supply voltage 380...500 V - 15...10 %
nominal output current 5.5 A
Motor power kW 2.2 kW heavy duty
EMC filter Class C2 EMC filter integrated
IP degree of protection IP20

Complementary

Characteristic Value(s)
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC1.5 kOhm
DI1...DI6 logic inputs, 24 V DC 30 V)
DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage 0...10 V DC 30 kOhm 10 bits
AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits
AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits
Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Relay output type Configurable relay logic R1A 1 NO 100000 cycles
Configurable relay logic R1B 1 NC 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
Method of access Slave CANopen
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensation Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 8.7 A 380 V heavy duty)
6.6 A 500 V heavy duty)
Maximum Input Current per Phase 8.7 A
Maximum output voltage 500 V
Apparent power 5.7 kVA 500 V heavy duty)
Network Frequency 50-60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 5 kA
Base load current at high overload 8.0 A
Power dissipation in W Fan 74.0 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks drive
Overcurrent between output phases and earth drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection drive
Width 5.5 in (140 mm)
Height 7.2 in (184.0 mm)
Depth 6.2 in (158.0 mm)
Product Weight 4.6 lb(US) (2.1 kg)
Transient overtorque 170…200 % of nominal motor torque
ATV930D30N4 Schneider Electric
Schneider ATV930D30N4 Schneider Electric
Sale price €1.564,95
Only 8 units left

Variable Speed Drive - ATV930 - 30kW - 400/480V - with braking unit - IP21

ATV212HU75N4 Schneider
Schneider ATV212HU75N4 Schneider
Sale price €550,95
Only 3 units left

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 7.5kW / 10hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.45kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.

Main

Characteristic Value(s)
Device short name ATV212
Product destination Asynchronous motors
Phase 3 phase
Motor power kW 7.5 kW
Maximum Horse Power Rating 10 hp
Supply voltage limits 323…528 V
Supply frequency 50...60 Hz - 5...5 %
Line current 11.7 A 480 V
14.7 A 380 V
Range of Product Altivar 212
Product or Component Type Variable speed drive
Product Specific Application Pumps and fans in HVAC
Communication Port Protocol APOGEE FLN
LonWorks
BACnet
METASYS N2
Modbus
[Us] rated supply voltage 380...480 V - 15...10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP21

Complementary

Characteristic Value(s)
Apparent power 12.2 kVA 380 V
Continuous output current 16 A 380 V
16 A 460 V
Maximum transient current 17.6 A 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14
L1/R, L2/S, L3/T terminal 0.02 in² (16 mm²) / AWG 6
Tightening torque 5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
22.1 lbf.in (2.5 N.m), 22 lb.in L1/R, L2/S, L3/T)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms +/- 0.5 ms analog
FLA, FLC 7 ms +/- 0.5 ms discrete
FLB, FLC 7 ms +/- 0.5 ms discrete
RY, RC 7 ms +/- 0.5 ms discrete
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C
+/- 0.6 % VIB) for a temperature variation 60 °C
+/- 1 % FM) for a temperature variation 60 °C
Linearity error VIA +/- 0.15 % of maximum value input
VIB +/- 0.15 % of maximum value input
FM +/- 0.2 % output
Analogue output type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits
FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles
Configurable relay logic FLB, FLC) NC - 100000 cycles
Configurable relay logic RY, RC) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm
R programmable 24 V DC level 1 PLC 4700 Ohm
RES programmable 24 V DC level 1 PLC 4700 Ohm
Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit 0.1 Hz
Analog input 0.024/50 Hz
Communication Service Monitoring inhibitable
Read holding registers (03) 2 words maximum
Write multiple registers (16) 2 words maximum
Write single register (06)
Read device identification (43)
Time out setting from 0.1 to 100 s
Option card Communication card LonWorks
Power dissipation in W 291 W
air flow 26417.7 Gal/hr(US) (100 m3/h)
Functionality Mid
Specific application HVAC
Variable speed drive application selection Building - HVAC compressor for scroll
Building - HVAC fan
Building - HVAC pump
Motor power range AC-3 7…11 kW 380…440 V 3 phase
7…11 kW 480…500 V 3 phase
Motor starter type Variable speed drive
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable PTC probe 0...6 probes 1500 Ohm
VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector Type 1 open style
1 RJ45
Transmission Rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio - Energy Saving, quadratic U/f
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, 2 points
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load
Motor slip compensation Not available in voltage/frequency ratio motor control
Automatic whatever the load
Adjustable
Switching frequency 6...16 kHz adjustable
12...16 kHz with derating factor
Nominal switching frequency 12 kHz
Braking to standstill By DC injection
Network Frequency 47.5...63 Hz
Prospective line Isc 22 kA
Protection type Overheating protection drive
Thermal power stage drive
Short-circuit between motor phases drive
Input phase breaks drive
Overcurrent between output phases and earth drive
Overvoltages on the DC bus drive
Break on the control circuit drive
Against exceeding limit speed drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Against input phase loss drive
Thermal protection motor
Motor phase break motor
With PTC probes motor
Width 7.09 in (180 mm)
Height 9.1 in (232 mm)
Depth 6.7 in (170 mm)
Product Weight 14.22 lb(US) (6.45 kg)
ATV930D37N4 Schneider Electric
Schneider ATV930D37N4 Schneider Electric
Sale price €2.013,95
In stock, 11 units

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 37kW/50hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 30kW/40hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV900
Product Specific Application Process for industrial
Product or Component Type Variable speed drive
Variant With braking chopper
Standard version
Device Application Industrial Application
Product destination Asynchronous motors
Synchronous motors
Phase 3 phase
Mounting Mode Wall mount
Continuous output current 74.5 A 4 kHz normal duty
61.5 A 4 kHz heavy duty
Communication Port Protocol Modbus TCP
Modbus serial
EtherNet/IP
Option card Slot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
communication module Ethernet Powerlink
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 74.5 A
Motor power kW 37.0 kW normal duty
30.0 kW heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1

Complementary

Characteristic Value(s)
Electrical connection Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
DC bus screw terminal 25...50 mm² AWG 4...AWG 1
Line side screw terminal 35...50 mm² AWG 3...AWG 1
Motor screw terminal 35...50 mm² AWG 3...AWG 1
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling Local diagnostic: 3 LED (mono/dual colour)
Embedded communication status: 5 LED (dual colour)
Communication module status: 2 LED (dual colour)
Presence of voltage: 1 LED (red)
Input compatibility DI1...DI8 discrete input level 1 PLC IEC 61131-2
DI7, DI8 pulse input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI8) - discrete input
5 ms +/- 1 ms DI7, DI8) - pulse input
1 ms +/- 1 ms AI1, AI2, AI3) - analog input
5 ms +/- 1 ms AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AQ1, AQ2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete input number 10
Discrete input type DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete input logic 16 preset speeds
Discrete output number 2
Discrete output type Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Maximum switching current Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Variable torque standard
Optimized torque mode
Constant torque standard
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Can be suppressed
Adjustable
Automatic whatever the load
Not available in permanent magnet motor law
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 66.2 A 380 V normal duty)
54.8 A 380 V heavy duty)
57.3 A 480 V normal duty)
48.3 A 480 V heavy duty)
Maximum Input Current per Phase 66.2 A
Maximum output voltage 480.0 V
Apparent power 47.6 kVA 480 V normal duty)
40.2 kVA 480 V heavy duty)
Maximum transient current 89.4 A 60 s normal duty)
92.3 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 61.5 A
Base load current at low overload 74.5 A
Power dissipation in W Natural convection 106 W 380 V 4 kHz
Forced convection 796 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 8.9 in (226 mm)
Height 26.5 in (673 mm)
Depth 10.7 in (271 mm)
Product Weight 62.2 lb(US) (28.2 kg)
ATV71HD15N4 Schneider Electric Altivar 71 Variable speed drive

Main

Characteristic Value(s)
Range of Product Altivar 71
Product or Component Type Variable speed drive
Product Specific Application Complex, high-power machines
Component name ATV71
Motor power kW 15 kW, 3 phase 380...480 V
Maximum Horse Power Rating 20 hp, 3 phase 380...480 V
Maximum motor cable length 164.04 ft (50 m) shielded cable
328.08 ft (100 m) unshielded cable
power supply voltage 380...480 V - 15...10 %
Phase 3 phase
Line current 39 A 480 V 3 phase 15 kW / 20 hp
48 A 380 V 3 phase 15 kW / 20 hp
EMC filter Integrated
Assembly style With heat sink
Apparent power 31.6 kVA 380 V 3 phase 15 kW / 20 hp
Prospective line Isc 22 kA 3 phase
Nominal output current 27 A 4 kHz 460 V 3 phase 15 kW / 20 hp
33 A 4 kHz 380 V 3 phase 15 kW / 20 hp
Maximum transient current 49.5 A 60 s 3 phase 15 kW / 20 hp
54.5 A 2 s 3 phase 15 kW / 20 hp
Output frequency 0.1…599 Hz
Nominal switching frequency 4 kHz
Switching frequency 1...16 kHz adjustable
4...16 kHz with derating factor
Asynchronous motor control profile ENA (Energy adaptation) system for unbalanced loads
Sensorless flux vector control (SFVC) (voltage or current vector)
Flux vector control (FVC) with sensor (current vector)
Voltage/frequency ratio (2 or 5 points)
Type of polarization No impedance Modbus

Complementary

Characteristic Value(s)
Product destination Synchronous motors
Asynchronous motors
power supply voltage limits 323…528 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Speed range 1…100 asynchronous motor in open-loop mode, without speed feedback
1…1000 asynchronous motor in closed-loop mode with encoder feedback
1…50 synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn
+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
+/- 5 % in closed-loop mode with encoder feedback
Transient overtorque 170 % +/- 10 % 60 s every 10 minutes
220 % +/- 10 % 2 s
Braking torque <= 150 % with braking or hoist resistor
30 % without braking resistor
Synchronous motor control profile Vector control without speed feedback
Regulation loop Adjustable PI regulator
Motor slip compensation Adjustable
Not available in voltage/frequency ratio (2 or 5 points)
Automatic whatever the load
Suppressable
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
Insulation Electrical between power and control
type of cable for mounting in an enclosure With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal 35 mm², AWG 2 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
47.8 lbf.in (5.4 N.m), 47.7 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign
AI2 software-configurable current 0...20 mA 242 Ohm 11 bits
AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
input sampling time 2 ms +/- 0.5 ms AI1-/Al1+) - analog
2 ms +/- 0.5 ms Al2) - analog
2 ms +/- 0.5 ms LI1...LI5) - discrete
2 ms +/- 0.5 ms LI6)if configured as logic input - discrete
Response time <= 100 ms in STO (Safe Torque Off)
AO1 2 ms +/- 0.5 ms analog
R1A, R1B, R1C 7 ms +/- 0.5 ms discrete
R2A, R2B 7 ms +/- 0.5 ms discrete
absolute accuracy precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % AI2) for a temperature variation 60 °C
+/- 1 % AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value AI1-/Al1+, AI2)
+/- 0.2 % AO1)
Analogue output number 1
Analogue output type AO1 software-configurable logic output 10 V 20 mA
AO1 software-configurable current 0...20 mA 500 Ohm 10 bits
AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic R2A, R2B) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current R1, R2 2 A 250 V AC inductive, cos phi = 0.4
R1, R2 2 A 30 V DC inductive, cos phi = 0.4
R1, R2 5 A 250 V AC resistive, cos phi = 1
R1, R2 5 A 30 V DC resistive, cos phi = 1
Discrete input number 7
Discrete input type LI1...LI5 programmable 24 V DC level 1 PLC 3500 Ohm
LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm
LI6 switch-configurable PTC probe 0…6 1500 Ohm
PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d
Discrete input logic Negative logic (sink) LI1...LI5), > 16 V, < 10 V
Positive logic (source) LI1...LI5), < 5 V, > 11 V
Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V
Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Braking to standstill By DC injection
Protection type Against exceeding limit speed drive
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Short-circuit between motor phases drive
Thermal protection drive
Motor phase break motor
Power removal motor
Thermal protection motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Communication Port Protocol Modbus
CANopen
Connector type 1 RJ45 on front face)Modbus
1 RJ45 on terminal)Modbus
Male SUB-D 9 on RJ45CANopen
Physical interface 2-wire RS 485 Modbus
Transmission frame RTU Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
9600 bps, 19200 bps Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format 8 bits, 1 stop, even parity Modbus on front face
8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses 1…127 CANopen
1…247 Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Height 15.7 in (400 mm)
Depth 8.4 in (213 mm)
Width 9.06 in (230 mm)
Product Weight 28.7 lb(US) (13 kg)
Functionality Full
Specific application Other applications
Option card Communication card CC-Link
Controller inside programmable card
Communication card DeviceNet
Communication card EtherNet/IP
Communication card Fipio
I/O extension card
Communication card Interbus-S
Interface card for encoder
Communication card Modbus Plus
Communication card Modbus TCP
Communication card Modbus/Uni-Telway
Overhead crane card
Communication card Profibus DP
Communication card Profibus DP V1
ATV320U07M2C Schneider
Schneider ATV320U07M2C Schneider
Sale price €174,95
Only 5 units left

This Altivar 320 variable speed drive can feed three-phase synchronous and asynchronous motors. Its compact form factor allows vertical stacking of drives inside machine frames. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 200V to 240V AC. Its robust design with IEC 60721-3-3 class 3C3 coated printed circuit boards allows to extend machine availability in harsh environmental conditions, for example at ambient temperatures of up to 60°C without the need of additional cooling. It incorporates functions suitable for the most common applications, including torque and speed accuracy at very low speed, high dynamic performance with flux vector control without sensor and extended frequency range for high-speed motors. It also incorporates parallel connection of motors and special drives using the voltage/frequency ratio and static speed accuracy and energy saving for open-loop synchronous motors. The drive software includes 5 safety functions that help machines meet safety requirements, whether or not they are used in conjunction with a Preventa safety module. These safety functions are configured using SoMove software. Altivar Machine ATV320 was designed for Original Equipment Manufacturers (OEMs) that meets simple and advanced application requirements covered for packaging, material handling, textile, material working, mechanical actuators and hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, NOM, EAC and RCM certified. Mounting accessories and external options (braking resistors, line chokes, motor chokes, additional EMC filters) are available with Altivar Machine ATV320 drives. The type of external accessories and options depends on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV320 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Main

Characteristic Value(s)
Range of Product Altivar Machine ATV320
Product or Component Type Variable speed drive
Product Specific Application Complex machines
Variant Standard version
Format of the drive Compact
Mounting Mode Wall mount
Communication Port Protocol Modbus serial
CANopen
Option card communication module, CANopen
communication module, EtherCAT
communication module, Profibus DP V1
communication module, PROFINET
communication module, Ethernet Powerlink
communication module, EtherNet/IP
communication module, DeviceNet
[Us] rated supply voltage 200...240 V - 15...10 %
nominal output current 4.8 A
Motor power kW 0.75 kW heavy duty
EMC filter Class C2 EMC filter integrated
IP degree of protection IP20

Complementary

Characteristic Value(s)
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC1.5 kOhm
DI1...DI6 logic inputs, 24 V DC 30 V)
DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage 0...10 V DC 30 kOhm 10 bits
AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits
AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits
Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Relay output type Configurable relay logic R1A 1 NO 100000 cycles
Configurable relay logic R1B 1 NC 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
Method of access Slave CANopen
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensation Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 10.1 A 200 V heavy duty)
8.4 A 240 V heavy duty)
Maximum Input Current per Phase 10.1 A
Maximum output voltage 240 V
Apparent power 2.0 kVA 240 V heavy duty)
Network Frequency 50-60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 1 kA
Base load current at high overload 33.0 A
Power dissipation in W Self-cooled 45.0 W 200 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks drive
Overcurrent between output phases and earth drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection drive
Width 2.8 in (72.0 mm)
Height 5.6 in (143.0 mm)
Depth 5.4 in (138.0 mm)
Product Weight 2.4 lb(US) (1.1 kg)
Transient overtorque 170…200 % of nominal motor torque
ATV320U07N4B Schneider
Schneider ATV320U07N4B Schneider
Sale price €210,95
Only 10 units left

This Altivar 320 variable speed drive can feed 3-phase synchronous and asynchronous motors. Its book form factor allows for a simple and compact installation in your automation cabinets. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 500V AC. Its robust design with IEC 60721-3-3 class 3C3 coated printed circuit boards allows to extend machine availability in harsh environmental conditions, for example at ambient temperatures of up to 60°C without the need of additional cooling. It incorporates functions suitable for the most common applications, including torque and speed accuracy at very low speed, high dynamic performance with flux vector control without sensor and extended frequency range for high-speed motors. It also incorporates parallel connection of motors and special drives using the voltage/frequency ratio and static speed accuracy and energy saving for open-loop synchronous motors. The drive software includes 5 safety functions that help machines meet safety requirements, whether or not they are used in conjunction with a Preventa safety module. These safety functions are configured using SoMove software. Altivar Machine ATV320 was designed for Original Equipment Manufacturers (OEMs) that meets simple and advanced application requirements covered for packaging, material handling, textile, material working, mechanical actuators and hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, NOM, EAC and RCM certified. Mounting accessories and external options (braking resistors, line chokes, motor chokes, additional EMC filters) are available with Altivar Machine ATV320 drives. The type of external accessories and options depends on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV320 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Main

Characteristic Value(s)
Range of Product Altivar Machine ATV320
Product or Component Type Variable speed drive
Product Specific Application Complex machines
Variant Standard version
Format of the drive Book
Mounting Mode Cabinet mount
Communication Port Protocol Modbus serial
CANopen
Option card communication module, CANopen
communication module, EtherCAT
communication module, Profibus DP V1
communication module, PROFINET
communication module, Ethernet Powerlink
communication module, EtherNet/IP
communication module, DeviceNet
[Us] rated supply voltage 380...500 V - 15...10 %
nominal output current 2.3 A
Motor power kW 0.75 kW heavy duty
EMC filter Class C2 EMC filter integrated
IP degree of protection IP20

Complementary

Characteristic Value(s)
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC1.5 kOhm
DI1...DI6 logic inputs, 24 V DC 30 V)
DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage 0...10 V DC 30 kOhm 10 bits
AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits
AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits
Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Relay output type Configurable relay logic R1A 1 NO 100000 cycles
Configurable relay logic R1B 1 NC 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
Method of access Slave CANopen
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensation Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 3.6 A 380 V heavy duty)
2.7 A 500 V heavy duty)
Maximum Input Current per Phase 3.6 A
Maximum output voltage 500 V
Apparent power 2.3 kVA 500 V heavy duty)
Network Frequency 50-60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 5 kA
Base load current at high overload 3.0 A
Power dissipation in W Fan 31 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks drive
Overcurrent between output phases and earth drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection drive
Width 1.8 in (45.0 mm)
Height 12.8 in (325.0 mm)
Depth 9.6 in (245.0 mm)
Product Weight 5.5 lb(US) (2.5 kg)
Transient overtorque 170…200 % of nominal motor torque
ATV12HU22M2 Schneider
Schneider ATV12HU22M2 Schneider
Sale price €214,95
Only 10 units left

Variable Speed Drive Altivar ATV12 - 2.2kW - 3hp - 200..240V - 1ph - with Heat Sink

ATV212HD37N4 Schneider
Schneider ATV212HD37N4 Schneider
Sale price €1.635,95
Only 8 units left

Variable Speed Drive Altivar ATV212 - 37kW - 50hp - 480V - 3ph - EMC - IP21

ATV930D22N4 Schneider Electric
Schneider ATV930D22N4 Schneider Electric
Sale price €1.238,95
In stock, 11 units

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 22kW/30hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 18.5kW/25hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV900
Product Specific Application Process for industrial
Product or Component Type Variable speed drive
Variant Standard version
With braking chopper
Device Application Industrial Application
Product destination Synchronous motors
Asynchronous motors
Phase 3 phase
Mounting Mode Wall mount
Continuous output current 46.3 A 4 kHz normal duty
39.2 A 4 kHz heavy duty
Communication Port Protocol Modbus serial
EtherNet/IP
Modbus TCP
Option card Slot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
communication module Ethernet Powerlink
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 46.3 A
Motor power kW 22.0 kW normal duty
18.5 kW heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1

Complementary

Characteristic Value(s)
Electrical connection Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 10...16 mm² AWG 8...AWG 6
DC bus screw terminal 10...16 mm² AWG 8...AWG 6
Motor screw terminal 16 mm² AWG 6
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling Local diagnostic: 3 LED (mono/dual colour)
Embedded communication status: 5 LED (dual colour)
Communication module status: 2 LED (dual colour)
Presence of voltage: 1 LED (red)
Input compatibility DI1...DI8 discrete input level 1 PLC IEC 61131-2
DI7, DI8 pulse input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI8) - discrete input
5 ms +/- 1 ms DI7, DI8) - pulse input
1 ms +/- 1 ms AI1, AI2, AI3) - analog input
5 ms +/- 1 ms AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AQ1, AQ2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete input number 10
Discrete input type DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete input logic 16 preset speeds
Discrete output number 2
Discrete output type Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Maximum switching current Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Variable torque standard
Optimized torque mode
Constant torque standard
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 39.6 A 380 V normal duty)
34.1 A 380 V heavy duty)
34.4 A 480 V normal duty)
29.9 A 480 V heavy duty)
Maximum Input Current per Phase 39.6 A
Maximum output voltage 480.0 V
Apparent power 28.6 kVA 480 V normal duty)
24.9 kVA 480 V heavy duty)
Maximum transient current 55.6 A 60 s normal duty)
58.8 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 39.2 A
Base load current at low overload 46.3 A
Power dissipation in W Natural convection 68 W 380 V 4 kHz
Forced convection 505 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 8.3 in (211 mm)
Height 21.5 in (545.9 mm)
Depth 9.3 in (235 mm)
Product Weight 31.5 lb(US) (14.3 kg)
ATV630D75N4 Schneider Electric
Schneider ATV630D75N4 Schneider Electric
Sale price €3.591,95
Only 9 units left

Variable Speed Drive ATV630 - 75kW/100hp - 380...480V - IP21/UL type 1

ATV930U75N4 Schneider Electric
Schneider ATV930U75N4 Schneider Electric
Sale price €742,95
Only 7 units left

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 7.5kW/10hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 5.5kW/7.5hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV900
Product Specific Application Process for industrial
Product or Component Type Variable speed drive
Variant Standard version
With braking chopper
Device Application Industrial Application
Product destination Asynchronous motors
Synchronous motors
Phase 3 phase
Mounting Mode Wall mount
Continuous output current 16.5 A 4 kHz normal duty
12.7 A 4 kHz heavy duty
Communication Port Protocol EtherNet/IP
Modbus TCP
Modbus serial
Option card Slot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
communication module Ethernet Powerlink
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 16.5 A
Motor power kW 7.5 kW normal duty
5.5 kW heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1

Complementary

Characteristic Value(s)
Electrical connection Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 4...6 mm² AWG 12...AWG 10
Motor screw terminal 6...10 mm² AWG 10...AWG 8
DC bus screw terminal 4...6 mm² AWG 12...AWG 10
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling Local diagnostic: 3 LED (mono/dual colour)
Embedded communication status: 5 LED (dual colour)
Communication module status: 2 LED (dual colour)
Presence of voltage: 1 LED (red)
Input compatibility DI1...DI8 discrete input level 1 PLC IEC 61131-2
DI7, DI8 pulse input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI8) - discrete input
5 ms +/- 1 ms DI7, DI8) - pulse input
1 ms +/- 1 ms AI1, AI2, AI3) - analog input
5 ms +/- 1 ms AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AQ1, AQ2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete input number 10
Discrete input type DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete input logic 16 preset speeds
Discrete output number 2
Discrete output type Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Maximum switching current Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Variable torque standard
Constant torque standard
Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 13.8 A 380 V normal duty)
10.5 A 380 V heavy duty)
11.9 A 480 V normal duty)
9.2 A 480 V heavy duty)
Maximum Input Current per Phase 13.8 A
Maximum output voltage 480.0 V
Apparent power 9.9 kVA 480 V normal duty)
7.6 kVA 480 V heavy duty)
Maximum transient current 19.8 A 60 s normal duty)
19.1 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 12.7 A
Base load current at low overload 16.5 A
Power dissipation in W Forced convection 172 W 380 V 4 kHz
Natural convection 44 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 6.7 in (171 mm)
Height 16.1 in (409 mm)
Depth 9.3 in (236 mm)
Product Weight 17.0 lb(US) (7.7 kg)
ATV212HD18N4 Schneider
Schneider ATV212HD18N4 Schneider
Sale price €1.033,95
In stock, 63 units

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 18.5kW / 25hp and a rated voltage from 380V to 480V AC. Its design allows for up to 70% reduction in energy consumption compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 11.65kg and its dimensions are, 245mm wide, 330mm high, 190mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.

Main

Characteristic Value(s)
Device short name ATV212
Product destination Asynchronous motors
Phase 3 phase
Motor power kW 18.5 kW
Maximum Horse Power Rating 25 hp
Supply voltage limits 323…528 V
Supply frequency 50...60 Hz - 5...5 %
Line current 27.8 A 480 V
34.8 A 380 V
Range of Product Altivar 212
Product or Component Type Variable speed drive
Product Specific Application Pumps and fans in HVAC
Communication Port Protocol APOGEE FLN
BACnet
LonWorks
Modbus
METASYS N2
[Us] rated supply voltage 380...480 V - 15...10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP21

Complementary

Characteristic Value(s)
Apparent power 28.2 kVA 380 V
Continuous output current 37 A 380 V
37 A 460 V
Maximum transient current 40.7 A 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14
L1/R, L2/S, L3/T terminal 0.04 in² (25 mm²) / AWG 3
Tightening torque 5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
39.8 lbf.in (4.5 N.m), 40 lb.in L1/R, L2/S, L3/T)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms +/- 0.5 ms analog
FLA, FLC 7 ms +/- 0.5 ms discrete
FLB, FLC 7 ms +/- 0.5 ms discrete
RY, RC 7 ms +/- 0.5 ms discrete
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C
+/- 0.6 % VIB) for a temperature variation 60 °C
+/- 1 % FM) for a temperature variation 60 °C
Linearity error VIA +/- 0.15 % of maximum value input
VIB +/- 0.15 % of maximum value input
FM +/- 0.2 % output
Analogue output type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits
FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles
Configurable relay logic FLB, FLC) NC - 100000 cycles
Configurable relay logic RY, RC) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm
R programmable 24 V DC level 1 PLC 4700 Ohm
RES programmable 24 V DC level 1 PLC 4700 Ohm
Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit 0.1 Hz
Analog input 0.024/50 Hz
Communication Service Time out setting from 0.1 to 100 s
Read device identification (43)
Monitoring inhibitable
Read holding registers (03) 2 words maximum
Write multiple registers (16) 2 words maximum
Write single register (06)
Option card Communication card LonWorks
Power dissipation in W 603 W
air flow 56533.8 Gal/hr(US) (214 m3/h)
Functionality Mid
Specific application HVAC
Variable speed drive application selection Building - HVAC compressor for scroll
Building - HVAC fan
Building - HVAC pump
Motor power range AC-3 15…25 kW 380…440 V 3 phase
15…25 kW 480…500 V 3 phase
Motor starter type Variable speed drive
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable PTC probe 0...6 probes 1500 Ohm
VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector Type 1 open style
1 RJ45
Transmission Rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Voltage/frequency ratio - Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Flux vector control without sensor, standard
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load
Motor slip compensation Not available in voltage/frequency ratio motor control
Automatic whatever the load
Adjustable
Switching frequency 6...16 kHz adjustable
8...16 kHz with derating factor
Nominal switching frequency 8 kHz
Braking to standstill By DC injection
Network Frequency 47.5...63 Hz
Prospective line Isc 22 kA
Protection type Overheating protection drive
Thermal power stage drive
Short-circuit between motor phases drive
Input phase breaks drive
Overcurrent between output phases and earth drive
Overvoltages on the DC bus drive
Break on the control circuit drive
Against exceeding limit speed drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Against input phase loss drive
Thermal protection motor
Motor phase break motor
With PTC probes motor
Width 9.6 in (245 mm)
Height 13.0 in (330 mm)
Depth 7.5 in (190 mm)
Product Weight 25.68 lb(US) (11.65 kg)
ATV930D45N4 Schneider Electric
Schneider ATV930D45N4 Schneider Electric
Sale price €2.211,95
In stock, 12 units

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 45kW/60hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 37kW/50hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV900
Product Specific Application Process for industrial
Product or Component Type Variable speed drive
Variant Standard version
With braking chopper
Device Application Industrial Application
Product destination Synchronous motors
Asynchronous motors
Phase 3 phase
Mounting Mode Wall mount
Continuous output current 88 A 4 kHz normal duty
74.5 A 4 kHz heavy duty
Communication Port Protocol EtherNet/IP
Modbus serial
Modbus TCP
Option card Slot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
communication module Ethernet Powerlink
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 88.0 A
Motor power kW 45.0 kW normal duty
37.0 kW heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1

Complementary

Characteristic Value(s)
Electrical connection Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 35...50 mm² AWG 2...AWG 1
Motor screw terminal 50 mm² AWG 1
DC bus screw terminal 35...50 mm² AWG 3...AWG 1
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling Local diagnostic: 3 LED (mono/dual colour)
Embedded communication status: 5 LED (dual colour)
Communication module status: 2 LED (dual colour)
Presence of voltage: 1 LED (red)
Input compatibility DI1...DI8 discrete input level 1 PLC IEC 61131-2
DI7, DI8 pulse input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI8) - discrete input
5 ms +/- 1 ms DI7, DI8) - pulse input
1 ms +/- 1 ms AI1, AI2, AI3) - analog input
5 ms +/- 1 ms AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AQ1, AQ2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete input number 10
Discrete input type DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete input logic 16 preset speeds
Discrete output number 2
Discrete output type Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Maximum switching current Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Constant torque standard
Optimized torque mode
Variable torque standard
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Automatic whatever the load
Adjustable
Not available in permanent magnet motor law
Can be suppressed
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 79.8 A 380 V normal duty)
67.1 A 380 V heavy duty)
69.1 A 480 V normal duty)
59.0 A 480 V heavy duty)
Maximum Input Current per Phase 79.8 A
Maximum output voltage 480.0 V
Apparent power 57.4 kVA 480 V normal duty)
49.1 kVA 480 V heavy duty)
Maximum transient current 105.6 A 60 s normal duty)
111.8 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 74.5 A
Base load current at low overload 88.0 A
Power dissipation in W Natural convection 121 W 380 V 4 kHz
Forced convection 943 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 8.9 in (226 mm)
Height 26.5 in (673 mm)
Depth 10.8 in (274 mm)
Product Weight 63.3 lb(US) (28.7 kg)
ATV630U15N4 Schneider Electric
Schneider ATV630U15N4 Schneider Electric
Sale price €534,95
Only 6 units left

Variable Speed Drive ATV630 - 1.5kW/2hp - 380...480V - IP21/UL type 1

ATV630C13N4 Schneider Electric
Schneider ATV630C13N4 Schneider Electric
Sale price €5.559,95
Only 6 units left

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 132kW / 200hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 110kW / 150hp for applications requiring significant overload (up to 150%). It weighs 82kg and its dimensions are, 320mm wide, 852mm high, 390mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Main

Characteristic Value(s)
Range of Product Altivar Process ATV600
Product Specific Application Process and utilities
Product or Component Type Variable speed drive
Variant Standard version
Device short name ATV630
Mounting Mode Wall mount
Communication Port Protocol Ethernet
Modbus TCP
Modbus serial
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 250.0 A
IP degree of protection IP21
Product destination Asynchronous motors
Synchronous motors
EMC filter Integrated 492.1 ft (150 m) IEC 61800-3 category C3
IP degree of protection IP00IEC 61800-5-1
IP00IEC 60529
IP21 with kit VW3A9704)IEC 61800-5-1
IP21 with kit VW3A9704)IEC 60529
type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
Motor power kW 132 kW normal duty)
110 kW heavy duty)
Maximum Horse Power Rating 200 hp normal duty
150 hp heavy duty
Line current 237 A 380 V normal duty)
213 A 480 V normal duty)
201 A 380 V heavy duty)
165 A 480 V heavy duty)
Continuous output current 250 A 2.5 kHz normal duty
211 A 2.5 kHz heavy duty
Speed drive output frequency 0.1…500 Hz
Safety function STO (safe torque off) SIL 3
Option card Slot A communication module, Profibus DP V1
Slot A communication module, PROFINET
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/EtherNet/IP
Slot A communication module, CANopen daisy chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw terminals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A communication module, Ethernet IP/Modbus TCP/MD-Link
communication module, BACnet MS/TP
communication module, Ethernet Powerlink

Complementary

Characteristic Value(s)
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
Discrete input logic 16 preset speeds
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 10 bits
Software-configurable current DQ-, DQ+ 30 V DC
Software-configurable current DQ-, DQ+ 100 mA
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
Maximum switching current Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Phase 3 phase
Physical interface Ethernet
2-wire RS 485
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frame RTU
Output voltage <= power supply voltage
Permissible temporary current boost 1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Frequency resolution Display unit 0.1 Hz
Analog input 0.012/50 Hz
Electrical connection Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 2 x 70...3 x 120 mm² 2 x AWG 2/0...2 x 300 kcmil
Motor screw terminal 2 x 70...3 x 120 mm² 2 x AWG 2/0...2 x 300 kcmil
Connector type RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses 1…247 Modbus serial
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling 3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Input compatibility DI1...DI6 discrete input level 1 PLC IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Sampling duration 2 ms +/- 0.5 ms DI1...DI4) - discrete input
5 ms +/- 1 ms DI5, DI6) - discrete input
5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation Between power and control terminals
Discrete and process manufacturing Building - HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Power range 110…220 kW 380…440 V 3 phase
110…220 kW 480…500 V 3 phase
Enclosure mounting Wall mounted
4 quadrant operation possible False
Asynchronous motor control profile Constant torque standard
Optimized torque mode
Variable torque standard
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 500 kHz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
Can be suppressed
Switching frequency 2.5...8 kHz with derating factor
2...8 kHz adjustable
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated False
Maximum Input Current per Phase 237.0 A
Maximum output voltage 480.0 V
Apparent power 161.4 kVA 480 V normal duty)
121.8 kVA 480 V heavy duty)
Maximum transient current 275 A 60 s normal duty)
316.5 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 211.0 A
Base load current at low overload 250.0 A
Power dissipation in W Forced convection 2755 W 380 V 2.5 kHz
With safety function Safely Limited Speed (SLS) False
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) False
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 12.6 in (320 mm)
Height 33.5 in (852 mm)
Depth 15.4 in (390 mm)
Product Weight 180.8 lb(US) (82 kg)

Recently viewed