Schneider_New_Products

5001 products

Showing 4249 - 4272 of 5001 products

Showing 4249 - 4272 of 5001 products
View
Schneider New Stock Image
Schneider LXM05BD57N4 Schneider
Sale price €5.307,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LXM05BD10M2 Schneider
Sale price €769,95
Only 3 units left

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05B
Network number of phases Single phase
power supply voltage 200...240 V - 15...10 %
Continuous output current 4 A at 4 kHz
3.2 A at 8 kHz
Nominal power 0.75 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Type of polarization No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 170…264 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 6 A at 8 kHz for 3 s
7 A at 4 kHz for 3 s
Line current 6.7 A at 240 V
8.1 A at 200 V
maximum prospective line Isc 1 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 2.5 mm², AWG 14 (PA/+, PBI, PBe)
Terminal, clamping capacity: 2.5 mm², AWG 14 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 0.8 N.m
R/L1, S/L2, T/L3: 0.8 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol Profibus DP
Modbus
Connector type RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for Profibus DP
Physical interface 2-wire RS485 multidrop Modbus
2-wire RS485 multidrop Profibus DP
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 9600 bps, 19.2, 45.45, 93.75, 187.5, 500 kbps, 1.5, 3, 6, 12 Mbps for Profibus DP
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…126 for Profibus DP
1…247 for Modbus
Communication service 12 Process Data bytes for Profibus DP
8 PKW bytes for Profibus DP
Communication monitoring for Modbus
Communication monitoring for Profibus DP
Diagnostics (08) for Modbus
PPO type 2 for Profibus DP
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
ERR: 1 LED (Profibus DP)
RUN: 1 LED (Profibus DP)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Natural convection
Operating position Vertical +/- 10 degree
Product weight 1.1 kg
Schneider New Stock Image
Schneider LXM05BD14N4 Schneider
Sale price €2.425,95
Only 5 units left

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05B
Network number of phases Three phase
power supply voltage 380...480 V - 15...10 %
Continuous output current 5 A at 8 kHz
6 A at 4 kHz
Nominal power 1.4 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Type of polarization No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 323…528 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 10 A at 4 kHz for 3 s
7.5 A at 8 kHz for 3 s
Line current 3.3 A at 480 V
4.2 A at 380 V
maximum prospective line Isc 5 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol Profibus DP
Modbus
Connector type RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for Profibus DP
Physical interface 2-wire RS485 multidrop Modbus
2-wire RS485 multidrop Profibus DP
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 9600 bps, 19.2, 45.45, 93.75, 187.5, 500 kbps, 1.5, 3, 6, 12 Mbps for Profibus DP
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…126 for Profibus DP
1…247 for Modbus
Communication service 12 Process Data bytes for Profibus DP
8 PKW bytes for Profibus DP
Communication monitoring for Modbus
Communication monitoring for Profibus DP
Diagnostics (08) for Modbus
PPO type 2 for Profibus DP
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
ERR: 1 LED (Profibus DP)
RUN: 1 LED (Profibus DP)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 1.4 kg
Schneider New Stock Image
Schneider LXM05AD57N4 Schneider
Sale price €1.467,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LXM05AD34N4 Schneider
Sale price €1.829,95
Only 3 units left

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05A
Network number of phases Three phase
power supply voltage 380...480 V - 15...10 %
Continuous output current 11 A at 8 kHz
15 A at 4 kHz
Nominal power 3 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Analogue input number 2
Type of polarization Integrated and switchable impedances for CANopen
No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 323…528 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 18 A at 8 kHz for 3 s
24 A at 4 kHz for 3 s
Line current 7.7 A at 480 V
9.7 A at 380 V
maximum prospective line Isc 5 kA
Switching frequency 4 kHz
8 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol CANopen
Modbus
CANopen Motionbus
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 2 kg
Schneider New Stock Image
Schneider LXM05AD28F1 Schneider
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05A
Network number of phases Single phase
power supply voltage 110...120 V - 15...10 %
Continuous output current 13 A at 8 kHz
15 A at 4 kHz
Nominal power 0.85 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Analogue input number 2
Type of polarization Integrated and switchable impedances for CANopen
No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 85…132 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 20 A at 4 kHz for 3 s
20 A at 8 kHz for 3 s
Line current 20.7 A at 120 V
22.6 A at 110 V
maximum prospective line Isc 1 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol Modbus
CANopen Motionbus
CANopen
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Natural convection
Operating position Vertical +/- 10 degree
Product weight 2 kg
Schneider New Stock Image
Schneider LXM05AD22N Schneider
Sale price €2.177,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LXM05AD22N4 Schneider
Sale price €1.652,95
Only 1 unit left

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05A
Network number of phases Three phase
power supply voltage 380...480 V - 15...10 %
Continuous output current 7 A at 8 kHz
9 A at 4 kHz
Nominal power 2 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Analogue input number 2
Type of polarization Integrated and switchable impedances for CANopen
No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 323…528 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 14 A at 8 kHz for 3 s
16 A at 4 kHz for 3 s
Line current 5 A at 480 V
6.3 A at 380 V
maximum prospective line Isc 5 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol CANopen
Modbus
CANopen Motionbus
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 2 kg
Schneider New Stock Image
Schneider LXM05AD17M2 Schneider
Sale price €4.305,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LXM05AD17F1 Schneider
Sale price €1.226,95
Only 1 unit left

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05A
Network number of phases Single phase
power supply voltage 110...120 V - 15...10 %
Continuous output current 7 A at 8 kHz
8 A at 4 kHz
Nominal power 0.65 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Analogue input number 2
Type of polarization Integrated and switchable impedances for CANopen
No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 85…132 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 11 A at 8 kHz for 3 s
12 A at 4 kHz for 3 s
Line current 10.5 A at 120 V
11.5 A at 110 V
maximum prospective line Isc 1 kA
Switching frequency 4 kHz
8 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol CANopen
Modbus
CANopen Motionbus
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 1.4 kg
Schneider New Stock Image
Schneider LXM05AD10M2S0 Schneider
Sale price €3.345,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV540306 Schneider
Sale price €303,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV432894 Schneider
Sale price €741,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV510347 Schneider
Sale price €138,95
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV432597 Schneider
Sale price €94,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV432464 Schneider
Sale price €628,95
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV431633 Schneider
Sale price €230,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV431631 Schneider
Sale price €263,95
Only 4 units left

This Compact NSX250F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 200A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX250F is part of Schneider Electric EcoStruxure Power architecture.

Main

Characteristic Value(s)
Range ComPact
product name ComPact NSX
Range of Product ComPact NSX100...250
Device short name NSX250F
Product or Component Type Circuit breaker
Device Application Distribution
Number of poles 3P
Protected poles description 3t
Line Rated Current 200 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz
Suitability for isolation Yes EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA 240 V AC 50/60 Hz UL 508
22 kA Icu 525 V AC 50/60 Hz IEC 60947-2
35 kA Icu 440 V AC 50/60 Hz IEC 60947-2
36 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2
8 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
85 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2
35 kA 480 V AC 50/60 Hz UL 508
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
15 kA 600 V AC 50/60 Hz UL 508
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control Type Toggle
Circuit breaker mounting mode Fixed

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 35 kA 440 V AC 50/60 Hz IEC 60947-2
36 kA 380/415 V AC 50/60 Hz IEC 60947-2
85 kA 220/240 V AC 50/60 Hz IEC 60947-2
22 kA 525 V AC 50/60 Hz IEC 60947-2
30 kA 500 V AC 50/60 Hz IEC 60947-2
8 kA 660/690 V AC 50/60 Hz IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 5000 cycles 690 V In
10000 cycles 690 V In/2
10000 cycles 440 V In
20000 cycles 440 V In/2
Mounting Support Backplate
Upside connection Front
Downside connection Front
Connection pitch 1.4 in (35 mm)
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 200 A 104 °F (40 °C)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 5...10 x In
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5
Width (W) 4.1 in (105 mm)
Height (H) 6.3 in (161 mm)
Depth (D) 3.4 in (86 mm)
Product Weight 5.3 lb(US) (2.4 kg)
Schneider New Stock Image
Schneider LV430833 Schneider
Sale price €167,95
Only 4 units left

Main

Characteristic Value(s)
Range ComPact
product name ComPact NSX
Range of product ComPact NSX100...250
Device short name NSX160N
Product or component type Circuit breaker
Device application Motor
Number of poles 3P
Protected poles description 3t
[In] rated current 100 A at 65 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 480 V AC 50/60 Hz conforming to UL 508
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name MA
Trip unit technology Magnetic
Trip unit protection functions I
control type Toggle
Circuit breaker mounting mode Fixed

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 40000 cycles
Electrical durability 7500 cycles at 690 V In
15000 cycles at 690 V In/2
20000 cycles at 440 V In
40000 cycles at 440 V In/2
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Protection type I : for short-circuit protection (magnetic)
Trip unit rating 100 A at 65 °C
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 9...14 x In
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Product weight 2.2 kg
Schneider New Stock Image
Schneider LV430633 Schneider
Sale price €177,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV430630 Schneider
Sale price €203,95
Only 1 unit left

This Compact NSX160F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 160A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX160F is part of Schneider Electric EcoStruxure Power architecture.

Main

Characteristic Value(s)
Range ComPact
product name ComPact NSX
Range of Product ComPact NSX100...250
Device short name NSX160F
Product or Component Type Circuit breaker
Device Application Distribution
Number of poles 3P
Protected poles description 3t
Line Rated Current 160 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz
Suitability for isolation Yes EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 10 kA 600 V AC 50/60 Hz UL 508
85 kA 240 V AC 50/60 Hz UL 508
22 kA Icu 525 V AC 50/60 Hz IEC 60947-2
35 kA Icu 440 V AC 50/60 Hz IEC 60947-2
36 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2
8 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
85 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2
35 kA 480 V AC 50/60 Hz UL 508
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control Type Toggle
Circuit breaker mounting mode Fixed

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 35 kA 440 V AC 50/60 Hz IEC 60947-2
36 kA 380/415 V AC 50/60 Hz IEC 60947-2
85 kA 220/240 V AC 50/60 Hz IEC 60947-2
22 kA 525 V AC 50/60 Hz IEC 60947-2
30 kA 500 V AC 50/60 Hz IEC 60947-2
8 kA 660/690 V AC 50/60 Hz IEC 60947-2
Mechanical durability 40000 cycles
Electrical durability 7500 cycles 690 V In
15000 cycles 690 V In/2
20000 cycles 440 V In
40000 cycles 440 V In/2
Mounting Support Backplate
Upside connection Front
Downside connection Front
Connection pitch 1.4 in (35 mm)
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 160 A 104 °F (40 °C)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 1250 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5
Width (W) 4.1 in (105 mm)
Height (H) 6.3 in (161 mm)
Depth (D) 3.4 in (86 mm)
Product Weight 4.9 lb(US) (2.2 kg)
Schneider New Stock Image
Schneider LV429854 Schneider
Sale price €188,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV429846 Schneider
Sale price €153,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LV429842 Schneider
Sale price €153,95
Only 1 unit left

This Compact NSX100N is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 63A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX100N is part of Schneider Electric EcoStruxure Power architecture.

Main

Characteristic Value(s)
Range ComPact
product name ComPact NSX
Range of product ComPact NSX100...250
Device short name NSX100N
Product or component type Circuit breaker
Device application Distribution
Number of poles 3P
Protected poles description 3t
[In] rated current 63 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
50 kA at 480 V AC 50/60 Hz conforming to UL 508
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
control type Toggle
Circuit breaker mounting mode Fixed

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 500 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Product weight 2.05 kg

Recently viewed