Schneider_New_Products

5001 products

Showing 4153 - 4176 of 5001 products

Showing 4153 - 4176 of 5001 products
View
Schneider New Stock Image
Schneider METSEPM2125C2DI2RO Schneider
Sale price €328,95
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEPM2120 Schneider
Sale price €396,95
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEPM2110 Schneider
Sale price €726,95
Only 2 units left

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having 3 rows of bright red 4 digits 14.2 mm height LED display. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion for both current and volrage on per phase basis. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. The meter also has one digital pulse output for any energy parameters congigurable to different energy scaling. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).

Main

Characteristic Value(s)
Range EasyLogic
product name EasyLogic PM2100
Product or Component Type Power meter
Device short name PM2110

Complementary

Characteristic Value(s)
Device Application Power monitoring
Sub billing
Power quality analysis total harmonic distortion
Type of measurement Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Apparent energy total
Active and reactive energy total
Apparent power total
Active and reactive power total
Current average
Voltage average
Frequency average
Power factor average
Metering type Peak demand power PM, QM, SM
Apparent power S, S1, S2, S3
Current I, I1, I2, I3
Reactive power Q, Q1, Q2, Q3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Peak demand currents
Unbalance current
Demand power P, Q, S
Active power P, P1, P2, P3
Active, reactive, apparent energy (signed, four quadrant)
Accuracy class Class 1 active energy IEC 62053-21
Class 1 reactive energy IEC 62053-24
Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current 5…6000 mA
Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range 45…65 Hz
[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %
44...277 V DC +/- 10 %
Network Frequency 60 Hz
50 Hz
Ride-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
Line Rated Current 5 A
1 A
Maximum power consumption in VA 6 VA 277 V AC
Maximum power consumption in W 3.3 W power lines (AC))
2 W 277 V power lines (DC))
input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display Type 7 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 - 0.6 in (14.2 mm)
Demand intervals Configurable from 1 to 60 min
Information displayed Demand current past value)
Demand current present value)
Demand power past value)
Demand power present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type 3 x button
Local signalling Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED module operating (RUN)
Number of inputs 0
Number of Outputs 1 pulse
POP parameter 20 ms 5...40 V DC, 20 mA 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Impulse duration 20 ms
Communication port protocol POP
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication Service Remote monitoring
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-tick
Mounting Mode Clip-on
Mounting position Vertical
Mounting support Framework
Provided equipment 1 x Installation guide
Measurement category Category III 480 V
Category II 480…600 V
Electrical Insulation Class Double insulation
Class II
Flame retardance V-0 conforming to UL 94
Connections - terminals Current transformer screw connection bottom) 6
Voltage inputs screw connection top) 4
Material Polycarbonate
Width 3.8 in (96 mm)
Depth Total : 3.00 in (76.09 mm)
Embedded : 2.43 in (61.64 mm)
Height 3.8 in (96 mm)
Product Weight 10.6 oz (300 g)
Compatibility code PM2110
Schneider New Stock Image
Schneider METSEPM2105CL05 Schneider
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEPM1120H Schneider
Sale price €634,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEPM1000 Schneider
Sale price €395,95
Only 1 unit left

Main

Characteristic Value(s)
Range of product PowerLogic PM1000
Device short name PM1000
Product or component type Power meter

Complementary

Characteristic Value(s)
Power quality analysis Up to the 9th harmonic
Type of measurement Current
Voltage
Frequency
Active and reactive power
Active and reactive energy
Power factor
supply voltage 44...277 V AC 50/60 Hz
44...277 V DC
Network frequency 50/60 Hz
Maximum power consumption in VA 3 VA at 240 V AC
Display type LED
Display resolution 3 lines with 4 digits
Sampling rate 20 samples/cycle
Measurement current 50…6000 mA
input type Current 0...5 A (impedance <= 0.1 Ohm)
Current 0...1 A (impedance <= 0.1 Ohm)
Measurement voltage 80…480 V AC 50/60 Hz phase to phase
0…999000 V AC 50/60 Hz with external VT
Measurement accuracy Power 1 %
Current 1 %
Voltage 1 %
Energy 1 %
Frequency 0.1 %
Power factor 1 %
Apparent power 1 %
Accuracy class Class 2 reactive energy conforming to IEC 62053-23
Class 1 active energy conforming to IEC 62053-21
Schneider New Stock Image
Schneider METSEION95030 Schneider
Sale price €17.254,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEPM Schneider
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEION93040 Schneider
Sale price €17.826,95
Only 3 units left

The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs with low voltage transducer; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Energy and power quality meter
Device short name ION93040
product name PowerLogic ION9000
Device Application Power monitoring
WAGES metering
Net metering
Medium voltage
High voltage
Metering type Demand current I1, I2, I3, I4, I5
Peak demand currents
Demand power P, Q, S
Peak demand power PM, QM, SM
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Provided Equipment Remote display
Remote display adapter
Mounting instructions
Mounting Hardware

Complementary

Characteristic Value(s)
Power quality analysis EN 50160 compliance checking
IEEE 519 harmonic limit
IEC 61000-4-30 class A compliance reporting
IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to the 63rd harmonic
up to the 127th harmonic with software
disturbance direction detection
dip, swell and transient
half cycle data acquisition
transient detection (20 µs)
Type of measurement Voltage sags and swells
Current sags and swells
Voltage
Current
Frequency
Active and reactive power total
Apparent power total
Active and reactive power per phase
Apparent power per phase
Power factor total
Power factor per phase
Active and reactive energy
Apparent energy
Harmonic distorsion (I THD & U THD)
[Us] rated supply voltage 90...480 V AC 45...66 Hz +/- 10 %
90...120 V AC 400 Hz +/- 10 %
110...480 V DC +/- 10 %
Network Frequency 50 Hz
60 Hz
Ride-through time 100 ms 6 cycles at 60 Hz 120 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
type of network 3P + N + E
Power consumption in VA 38 VA 480 V AC
Maximum power consumption in VA 80 VA 480 V AC
Display Resolution 800 x 480 pixels
Display Type Remote LCD display
Colour touchscreen
Sampling rate 1024 samples/cycle
input type Voltage (impedance 5 MOhm)
Split core current transducer (impedance 200 kOhm)5 x
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Frequency measurement range 20…450 Hz
Number of inputs 8 digital 30 V AC/60 V DC
Measurement accuracy Voltage +/- 0.1 %
Current +/- 0.1 %
Accuracy class Class 0.1S active energy IEC 62053-22
Class 0.1 active energy IEC 61557-12
Class 0.1 active energy ANSI C12.20
Class 0.5S reactive energy IEC 62053-24
Class 0.1 current IEC 61557-12
Class 0.1 voltage IEC 61557-12
Class 0.1 active power IEC 61557-12
Class 0.5 power factor IEC 61557-12
Number of Outputs 4 digital
2 form C relay output
Communication port protocol Modbus RTU 2400...115200 bps - 2-wire
ION 2400...115200 bps - 2-wire
DNP3 2400...115200 bps - 2-wire
Modbus TCP 10/100 Mbit/s
ION TCP 10/100 Mbit/s
DNP3 TCP 10/100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
DHCP
DNS
DLMS
Communication port support 2 RS485 removable screw terminal block
Port Ethernet 10/100BASE-TX 2 RJ45
Communication gateway Ethernet/serial
Time synchronisation protocol GPS
IRIG-B
NTP
SNTP
PTP
Data recording Time stamping
Min/max of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trending/forecasting
Event logs
Alarm logs
Configuration change
Power outage
User login/logout
Data logs
GPS synchronisation
Sequence of event recording
Memory capacity 2 GB
Cybersecurity Syslog protocol support
Robust security logs
Port hardening
Enable/disable communication ports
Hardware metrology lock
Web services Viewing of captured waveform
Web page
Pass/fail report for IEEE 519
Pass/fail report for EN 50160
ITIC (CBEMA) curve
SEMI curve
NEMA motor derating curve
Alarm notification by e-mail
TLS 1.2
Push historical data via mail
Ethernet service DHCP client
Device Profile Web Services (DPWS)
Rapid Scanning Tree Protocol (RSTP)
FTP/HTTP/HTTPS
Communication Service Compliant reports
Power quality summary
Energy report
EcoStruxure Power Events Analysis
SMTP e-mail notification
SNMP
Tamperproof of settings Protected by sealable cover
Mounting support DIN rail meter device
Door cut-out remote display
Electrical insulation class Class III EN/IEC 62052-11
Isolation voltage III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width 6.3 in (160 mm)
Depth 5.3 in (135.3 mm)
Height 6.3 in (160 mm)
Product Weight 3.3 lb(US) (1.5 kg)
Market Segment Data center
Healthcare
Semiconductor
Pharmaceutical
Chemical
Energy
Mining
Schneider New Stock Image
Schneider METSEION92130 Schneider
Sale price €8.586,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEION92040 Schneider
Sale price €20.276,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEION92030 Schneider
Sale price €16.220,95
Only 5 units left

The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs of 1 A, 5 A; current class 2, 10, 20 A; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting or panel mounting (with back to back adapter) transducer, plus 2 display options, further enhance the flexibility and adaptability of the ION9000.

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Energy and power quality meter
Device short name ION92030
product name PowerLogic ION9000
Device Application Power monitoring
WAGES metering
Net metering
Medium voltage
High voltage
Metering type Demand current I1, I2, I3, I4, I5
Peak demand currents
Demand power P, Q, S
Peak demand power PM, QM, SM
Calculated active and reactive energy (+/- W.h, +/- VAR.h)

Complementary

Characteristic Value(s)
Power quality analysis EN 50160 compliance checking
IEEE 519 harmonic limit
IEC 61000-4-30 class A compliance reporting
IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to the 63rd harmonic
up to the 127th harmonic with software
disturbance direction detection
dip, swell and transient
half cycle data acquisition
transient detection (20 µs)
Type of measurement Voltage sags and swells
Current sags and swells
Voltage
Current
Frequency
Active and reactive power total
Apparent power total
Active and reactive power per phase
Apparent power per phase
Power factor total
Power factor per phase
Active and reactive energy
Apparent energy
Harmonic distorsion (I THD & U THD)
[Us] rated supply voltage 90...480 V AC 45...66 Hz +/- 10 %
90...120 V AC 400 Hz +/- 10 %
110...480 V DC +/- 10 %
Network Frequency 50 Hz
60 Hz
Ride-through time 100 ms 6 cycles at 60 Hz 120 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
Line Rated Current 1 A
5 A
type of network 3P + N + E
Power consumption in VA 38 VA 480 V AC
Maximum power consumption in VA 80 VA 480 V AC
Display Type Without Display
Sampling rate 1024 samples/cycle
Measurement current 0.01…20 A
input type Voltage (impedance 5 MOhm)
External CT (impedance 0.3 mOhm)5 x
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Frequency measurement range 20…450 Hz
Number of inputs 8 digital 30 V AC/60 V DC
Measurement accuracy Voltage +/- 0.1 %
Current +/- 0.1 %
Accuracy class Class 0.1S active energy IEC 62053-22
Class 0.1 active energy IEC 61557-12
Class 0.1 active energy ANSI C12.20
Class 0.5S reactive energy IEC 62053-24
Class 0.1 current IEC 61557-12
Class 0.1 voltage IEC 61557-12
Class 0.1 active power IEC 61557-12
Class 0.5 power factor IEC 61557-12
Number of Outputs 4 digital
2 form C relay
Communication port protocol Modbus RTU 2400...115200 bps - 2-wire
ION 2400...115200 bps - 2-wire
DNP3 2400...115200 bps - 2-wire
Modbus TCP 10/100 Mbit/s
ION TCP 10/100 Mbit/s
DNP3 TCP 10/100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
DHCP
DNS
DLMS
Communication port support 2 RS485 removable screw terminal block
Port Ethernet 10/100BASE-TX 2 RJ45
Communication gateway Ethernet/serial
Time synchronisation protocol GPS
IRIG-B
NTP
SNTP
PTP
Data recording Time stamping
Min/max of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trending/forecasting
Event logs
Alarm logs
Configuration change
Power outage
User login/logout
Data logs
GPS synchronisation
Sequence of event recording
Memory capacity 2 GB
Cybersecurity Syslog protocol support
Robust security logs
Port hardening
Enable/disable communication ports
Hardware metrology lock
Web services Viewing of captured waveform
Web page
Pass/fail report for IEEE 519
Pass/fail report for EN 50160
ITIC (CBEMA) curve
SEMI curve
NEMA motor derating curve
Alarm notification by e-mail
TLS 1.2
Push historical data via mail
Ethernet service DHCP client
Device Profile Web Services (DPWS)
Rapid Scanning Tree Protocol (RSTP)
FTP/HTTP/HTTPS
Communication Service Compliant reports
Power quality summary
Energy report
EcoStruxure Power Events Analysis
SMTP e-mail notification
SNMP
Tamperproof of settings Protected by sealable cover
Mounting support DIN rail
Electrical insulation class Class III EN/IEC 62052-11
Isolation voltage III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width 6.3 in (160 mm)
Depth 5.3 in (135.3 mm)
Height 6.3 in (160 mm)
Product Weight 3.3 lb(US) (1.5 kg)
Market Segment Data center
Healthcare
Semiconductor
Pharmaceutical
Chemical
Energy
Mining
Schneider New Stock Image
Schneider METSEION7400 Schneider
Sale price €6.086,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEHDPM6S480VC Schneider
Sale price €2.802,95
Only 2 units left

Main

Characteristic Value(s)
Range PowerLogic
product name PowerLogic HDPM6000
Product or Component Type Base unit
Device short name HDPM6000
Energy management Asset management
Measurement
Cost management
Power quality analysis waveform capture
total harmonic distortion
Type of measurement Current per channel
Current all channels
Active energy per channel
Active energy all channels
Active power per channel
Active power all channels
Apparent power per channel
Apparent power all channels
Reactive power per channel
Reactive power all channels
Frequency
Power factor per channel
Power factor average
Harmonic distorsion (I THD & U THD)
Harmonics meter
Active energy total
Active power total
Apparent power total
Apparent power demand per channel
Apparent power demand all channels
Active power demand per channel
Active power demand all channels
[Us] rated supply voltage 24 V DC
Network Frequency 60 Hz
50 Hz

Complementary

Characteristic Value(s)
current transformer input External CT
Measurement voltage 120…480 V AC 50/60 Hz
Poles description 2P + E
3P + E
3P + N + E
Measurement accuracy +/- 1 %
Measurement category Category III
Sampling rate 128 samples/cycle
Communication port protocol TCP/IP
Modbus
SNMP
BACnet
Communication port support 2 RJ45 ETHERNET
RS485 screw block terminal
I/O bus RJ45
Web services Web page
Controller configuration
Viewing of captured waveform
Real time viewing of data
Communication of data Power quality
Reading of measurements
Percentage of load
Memory capacity 8 GB
Noise level 0…65 dB
Schneider New Stock Image
Schneider METSEHDPM6S208VC Schneider
Sale price €1.882,95
Only 2 units left

Main

Characteristic Value(s)
Range PowerLogic
product name PowerLogic HDPM6000
Product or Component Type Base unit
Device short name HDPM6000
Energy management Asset management
Measurement
Cost management
Power quality analysis waveform capture
total harmonic distortion
Type of measurement Current per channel
Current all channels
Active energy per channel
Active energy all channels
Active power per channel
Active power all channels
Apparent power per channel
Apparent power all channels
Reactive power per channel
Reactive power all channels
Frequency
Power factor per channel
Power factor average
Harmonic distorsion (I THD & U THD)
Harmonics meter
Active energy total
Active power total
Apparent power total
Apparent power demand per channel
Apparent power demand all channels
Active power demand per channel
Active power demand all channels
[Us] rated supply voltage 24 V DC
Network Frequency 60 Hz

Complementary

Characteristic Value(s)
current transformer input External CT
Measurement voltage 120 V AC 60 Hz
208 V AC 60 Hz
Poles description 2P + E
3P + E
3P + N + E
Measurement accuracy +/- 1 %
Measurement category Category III
Sampling rate 128 samples/cycle
Communication port protocol TCP/IP
Modbus
SNMP
BACnet
Communication port support 2 RJ45 ETHERNET
RS485 screw block terminal
I/O bus RJ45
Web services Web page
Controller configuration
Viewing of captured waveform
Real time viewing of data
Communication of data Power quality
Reading of measurements
Percentage of load
Memory capacity 8 GB
Noise level 0…65 dB
Schneider New Stock Image
Schneider METSEHDPM6R24 Schneider
Sale price €2.457,95
Only 1 unit left

Main

Characteristic Value(s)
Range PowerLogic
product name PowerLogic HDPM6000
Product or Component Type Metering module
Device short name HDPM6000R
Energy management Asset management
Measurement
Cost management
Power quality analysis total harmonic distortion
Type of measurement Current per channel
Current all channels
Active energy per channel
Active energy all channels
Active power per channel
Active power all channels
Apparent power per channel
Apparent power all channels
Reactive power per channel
Reactive power all channels
Frequency
Power factor per channel
Power factor average

Complementary

Characteristic Value(s)
current transformer input External CT
Measurement category Category III
Sampling rate 128 samples/cycle
Communication port protocol TCP/IP
Modbus
SNMP
BACnet
Communication port support 2 RJ45 ETHERNET
Communication of data Power quality
Reading of measurements
Percentage of load
Memory capacity 8 GB
Noise level 0…65 dB
Schneider New Stock Image
Schneider METSEHDPM42BCLE4 Schneider
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Enclosure

Complementary

Characteristic Value(s)
Range compatibility PowerLogic PowerLogic HDPM6000
Cut-out dimensions 118.5 x 92.5 mm
Provided equipment 42 measuring input retrofit module
meter display
Display size 4.3 inch
Type of Door Solid
Width 16 in (406.4 mm)
Height 20 in (508.0000000000 mm)
Depth 6.75 in (171.45 mm)
Enclosure mounting Wall mounted
Acceptable Input Voltage 120 V
Material Steel
Schneider New Stock Image
Schneider METSEEM6400NGRSCL1 Schneider
Sale price €391,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEEM6436HCL10RS Schneider
Sale price €367,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSEDM6200 Schneider
Sale price €409,95
Only 1 unit left

Main

Characteristic Value(s)
Range of Product PowerLogic
Device short name DM6200
Product or Component Type Multimeter

Complementary

Characteristic Value(s)
Device Application Equipment monitoring
Power monitoring
Preventive maintenance
Type of measurement Current
Voltage
Frequency
Power factor
Phase unbalance
Phase angle
RPM
[Us] rated supply voltage 44...277 V AC 50/60 Hz
44...277 V DC
Network Frequency 45...65 Hz
Maximum power consumption in VA 3 VA 240 V AC
Display Type LED indicator
Sampling rate 20 samples/cycle
Measurement current 5 A
1 A
Analogue input type Current 0.05...6 A (impedance <= 0.1 Ohm)
Measurement voltage 80…480 V AC phase to phase
Measurement accuracy Frequency 0.1 %
Power factor 1 %
Voltage 1 % 46...277 V
Current 1 % 0.05...6 A
Communication Port Protocol Modbus
Communication port support Terminal block RS485
Transmission Rate 19.2 kbauds
Schneider New Stock Image
Schneider METSECTSP5A4120U Schneider
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Current transformer
Accessory / separate part category Measurement accessory

Complementary

Characteristic Value(s)
Range compatibility PowerLogic PowerLogic PM5000 power meter
PowerLogic PowerLogic PM3000 power meter
Acti 9 Acti9 iEM3000 energy meter
EasyLogic EasyLogic PM2100 power meter
EasyLogic EasyLogic PM2200 power meter
Current transformer type Split core
Primary operational current 1200 A
Secondary current 5 A
Network type AC
Network Frequency 50 Hz
60 Hz
Current transformer ratio 1200/5
Electrical connection 8 ft (2.4 m) AWG 16 flying lead
Insulation Basic insulation 600 V AC
Reinforced insulation 300 V AC
Measurement accuracy 1 %
Mounting Location Indoor use only
Width Internal: 2.47 in (62.74 mm)
Total: 4.91 in (124.71 mm)
Depth 1.16 in (29.46 mm)
Height Internal: 5.73 in (145.54 mm)
Total: 8.12 in (206.25 mm)
Product Weight 36.6 oz (1039 g)
Schneider New Stock Image
Schneider METSEDM2355N Schneider
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider METSECTSP5A4200U Schneider
Sale price €500,95
Only 1 unit left

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Current transformer
Accessory / separate part category Measurement accessory

Complementary

Characteristic Value(s)
Range compatibility PowerLogic PowerLogic PM5000 power meter
PowerLogic PowerLogic PM3000 power meter
Acti 9 Acti9 iEM3000 energy meter
EasyLogic EasyLogic PM2100 power meter
EasyLogic EasyLogic PM2200 power meter
Current transformer type Split core
Primary operational current 2000 A
Secondary current 5 A
Network type AC
Network Frequency 50 Hz
60 Hz
Current transformer ratio 2000/5
Electrical connection 8 ft (2.4 m) AWG 16 flying lead
Insulation Basic insulation 600 V AC
Reinforced insulation 300 V AC
Measurement accuracy 1 %
Mounting Location Indoor use only
Width Internal: 2.47 in (62.74 mm)
Total: 4.91 in (124.71 mm)
Depth 1.16 in (29.46 mm)
Height Internal: 5.73 in (145.54 mm)
Total: 8.12 in (206.25 mm)
Product Weight 34.9 oz (988 g)
Schneider New Stock Image
Schneider METSEDM2350N Schneider
Sale price €242,95
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed