Display (RD96) compatible with PowerLogic PM8000, ION7400 and ION9000. 96mm by 96mm color graphical LCD with push-button interface. Information avaiable from the display: power, energy consumption, harmonics, frequency, voltage, current, alarms and input output status. Viewable area: color TFT LCD, 320 pixels by 240 pixels QVGA. Panel mounting using a 30 mm push-button hole or 1/4 DIN cutout. Ingress Protection IP54 (UL type 12) rating.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| Product or Component Type | Remote display |
| Device Application | Human-machine dialogue application |
| Range compatibility | PowerLogic PowerLogic PM8000 PowerLogic PowerLogic ION7400 |
| Display Type | Colour TFT LCD |
Complementary
| Characteristic | Value(s) |
|---|---|
| Display Resolution | 320 x 240 pixels QVGA |
| Display size | 3.5 inch |
| Information Displayed | Energy consumption Voltage Power Harmonic distortion Frequency Current System alarm I/O status |
| Messages display capacity | Graphic objects (bargraph, button, light...) |
| Local signalling | Status LED Green) Alarm LED Red) |
| Control type | 5 x push-button |
| Connector Type | RJ45 |
| Provided equipment | Mounting Hardware Cable 9.8 ft (3 m) |
| Mounting Mode | Flush-mounted |
| Mounting support | Framework remote display |
| Width | 3.8 in (96 mm) |
| Height | 3.8 in (96 mm) |
| Projecting depth | 1.06 in (27 mm) |
| Product Weight | 10.6 oz (300 g) |


Optional Input Output module compatible with PowerLogic PM8000, ION7400 and ION9000 devices that provides additional analog inputs and analog outputs. This analog module provides 4 analog inputs that support 0 to 20mA, 4 to 20mA and 0 to 30V. Plus 2 analog outputs to interface with BMS and other systems. The analog outputs support 0 to 20mA, 4 to 20mA and 0 to 10V. Analog inputs and outputs are sampled by the host meter at a 1/2 cycle (8-10ms) rate. The option modules are attached to the side of the meter providing connection for control power and interfacing bus. The PowerLogic PM8000, ION7400 and ION9000 devices allow up to 4 input/output option modules per meter.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| Product or Component Type | I/O module |
| Device Application | Optional expansion module |
| Range compatibility | PowerLogic PowerLogic PM8000 PowerLogic PowerLogic ION7400 PowerLogic PowerLogic ION9000 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Number of outputs | 2 analog, 0-20 mA or 4-20 mA 0...10 V |
| Number of inputs | 4 analog 0...20 mA/4...20 mA 0...30 V |
| Width | 0.9 in (22 mm) |
| Depth | 3.6 in (90.5 mm) |
| Height | 3.6 in (90.5 mm) |
| Product Weight | 4.9 oz (140 g) |




The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. They reveal and provide understanding of complex power quality conditions enabling action to be taken to mitigate any issue. The PowerLogic PM8000 series meters have the versatility to perform nearly any job you need a meter to do, wherever you need it! The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. With patented Disturbance Direction Detection, revenue grade accuracy, multiple communication ports, onboard power quality analysis, web interface and a color graphical display. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). The PowerLogic PM8000 series provides data quality confidence you can count on. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 50 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Low voltage control power range of 24-60 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. Panel mounting (1/4 DIN) with integrated display.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | PowerLogic PM8000 |
| Product or Component Type | Power meter |
| Device short name | PM8210 |
| Market segment | Buildings large building cost management: billing: sub feeder Buildings small building network management: main incomer Buildings medium building network management: main incomer Buildings large building network management: main incomer Buildings large building network management: sub feeder Buildings multi-site network management: main incomer Buildings multi-site network management: sub feeder Data center network management: main incomer Data center network management: sub feeder Healthcare network management: main incomer Healthcare network management: sub feeder Industry network management: main incomer Industry network management: sub feeder Utility: sub feeder |
| model type | Standard |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power quality analysis | EN 50160 2010 compliance report IEEE 519 2014 compliance report IEC 61000-4-30 class S power quality measurement up to the 63rd harmonic harmonic distortion waveform capture voltage sag and swell detection programmablity (logic and math functions) IEC 62586 power quality monitoring disturbance direction detection rapid voltage change |
| Device Application | Power monitoring WAGES metering |
| Type of measurement | Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms |
| supply voltage | 20...60 V DC +/- 10 % |
| Network Frequency | 60 Hz 50 Hz |
| Line Rated Current | 10 A 5 A 1 A |
| Poles description | 3P 1P + N 3P + N |
| Power Consumption in W | 18 W |
| Display Type | Colour TFT LCD |
| Display Resolution | 320 x 240 pixels QVGA |
| Sampling rate | 256 samples/cycle |
| Measurement current | 50â¦10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm) Current (impedance 0.3 mOhm) |
| Measurement voltage | 57â¦400 V AC 42...69 Hz between phase and neutral 100â¦690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42â¦69 Hz |
| Number of inputs | 3 digital 30 V AC 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 % Voltage +/- 0.1 % Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy IEC 62053-22 Class 0.2 active energy ANSI C12.20 Class 0.2 active power IEC 61557-12 Class 0.5S reactive energy IEC 62053-24 Class 0.5 power factor IEC 61557-12 Class 0.2 voltage IEC 61557-12 Class 0.2 current IEC 61557-12 |
| Number of Outputs | 1 pulse |
| Information displayed | Voltage Current Frequency Power Energy consumption Harmonic distortion |
| Communication port protocol | Modbus RTU 115 kbauds - 2-wire ION 115 kbauds - 2-wire DNP3 IEC 61850 Modbus TCP/IP Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s RSTP 801.1d 2004 |
| Communication port support | ETHERNET Screw terminal block RS485 |
| Communication Network Type | IPv6 (internet protocol) |
| Data recording | Data logs Harmonics logs Waveform logs Min/max of instantaneous values Trending/forecasting Sag and swell logs Sequence of event recording GPS synchronisation Alarm logs Event logs Time stamping 50 data recorders |
| Memory capacity | 512 MB |
| Web services | Customizable home page File upload/download via FTP File upload/download via SFTP Web server Alarm notification by e-mail Viewing of captured waveform (FTP) Viewing of captured waveform (web) HTTPS server |
| Communication Service | NTP time synchronization SMTP e-mail notification DHCP RSTP support SNMP PTP time synchronization |
| Cybersecurity | Syslog protocol support Password protection Port hardening Enable/disable communication ports Robust security logs |
| Mounting Mode | Flush-mounted |
| Mounting support | Framework |
| Installation category | III |
| Safety Construction | III400â¦690 V conforming to IEC 61010-1:ed. 3 III400â¦690 V conforming to EN 61010-1:ed. 3 III347â¦600 V conforming to UL 61010-1:ed. 3 III347â¦600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 62052-11 IEC 61557-12 IEC 62053-22 IEC 62053-24 IEEE 1588 IEC 62586-2 IEC 61326-1 |
| Product certifications | CE CULus N998 |
| Width | 3.8 in (96 mm) |
| Depth | 3.05 in (77.5 mm) |
| Height | 3.8 in (96 mm) |
| Product Weight | 20.5 oz (581 g) |






This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 31st Harmonic. Include 256 kiloBytes of memory for two fixed parameters, active and reactive energy. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol are Modbus TCP/IP and BACnet/IP based on 10/100 Mbit/s, Ethernet with RJ45 port support. The meter also has two digital inputs or digital outputs, configurable. There are 35 configurable alarms and it supports four tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 15.2 onces (430 g).
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | PowerLogic PM5000 |
| Device short name | PM5320 |
| Product or component type | Power meter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power quality analysis | up to the 31st harmonic |
| Device application | Multi-tariff Power monitoring |
| Type of measurement | Current Voltage Frequency Power factor Energy Active and reactive power |
| supply voltage | 90...450 V AC 45...65 Hz 100...300 V DC |
| Network frequency | 50 Hz 60 Hz |
| [In] rated current | 1 A 5 A |
| type of network | 1P + N 3P + N 3P |
| Maximum power consumption in VA | 11 VA at 415 V |
| Ride-through time | 80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical 50 ms 125 V DC typical |
| Display type | Monochrome graphic LCD |
| Display resolution | 128 x 128 pixels |
| Sampling rate | 64 samples/cycle |
| Measurement current | 5â¦8500 mA |
| Analogue input type | Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm) |
| Measurement voltage | 35â¦760 V AC 45...65 Hz between phases 20â¦440 V AC 45...65 Hz between phase and neutral |
| Frequency measurement range | 45â¦65 Hz |
| Number of inputs | 2 digital |
| Measurement accuracy | Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.5 Current +/- 0.5 % Voltage +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 % |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
| Number of outputs | 2 digital |
| Information displayed | Tariff (4) |
| Communication port protocol | Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V BACnet IP |
| Communication port support | ETHERNET |
| Data recording | Maintenance logs Alarm logs Min/max of instantaneous values Event logs Time stamping Data logs |
| Memory capacity | 256 kB |
| Connections - terminals | Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 Relay output: screw terminal block4 Ethernet network: RJ45 connector |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Standards | IEC 62053-22:2020 EN 50470-1 IEC 60529 IEC 61557-12:2015 UL 61010-1 EN 50470-3 IEC 62053-24 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 |
| Width | 96 mm |
| Depth | 72 mm |
| Height | 96 mm |
| Product weight | 430 g |

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display and carries additional MID certification for revenue applications. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has one digital pulse output and 33 configurable alarms. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | PowerLogic PM5000 |
| Device short name | PM5111 |
| Product or component type | Power meter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power quality analysis | up to the 15th harmonic |
| Device application | Power monitoring |
| Type of measurement | Current Voltage Frequency Power factor Energy Active and reactive power |
| supply voltage | 90...450 V AC 45...65 Hz 100...300 V DC |
| Network frequency | 50 Hz 60 Hz |
| [In] rated current | 5 A 1 A |
| type of network | 3P 1P + N 3P + N |
| Maximum power consumption in VA | 11 VA at 415 V |
| Ride-through time | 80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical |
| Display type | Monochrome graphic LCD |
| Display resolution | 128 x 128 pixels |
| Sampling rate | 64 samples/cycle |
| Measurement current | 50â¦8500 mA |
| Analogue input type | Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm) |
| Measurement voltage | 35â¦760 V AC 45...65 Hz between phases 20â¦440 V AC 45...65 Hz between phase and neutral |
| Frequency measurement range | 45â¦65 Hz |
| Number of inputs | 0 |
| Measurement accuracy | Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.5 Current +/- 0.5 % Voltage +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 % |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
| Number of outputs | 1 digital |
| Communication port protocol | Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V JBUS |
| Communication port support | RS485 |
| Data recording | Time stamping Min/max of instantaneous values |
| Connections - terminals | Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 RS485 link: screw terminal block4 |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Standards | IEC 61557-12:2015 EN 50470-1 UL 61010-1 IEC 62053-24 IEC 60529 EN 50470-3 IEC 62053-22:2020 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 MID conforming to EN 50470-1 MID conforming to EN 50470-3 |
| Width | 96 mm |
| Depth | 72 mm |
| Height | 96 mm |
| Product weight | 380 g |


This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication is pulse output only. The meter also has 33 configurable alarms. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | PowerLogic PM5000 |
| Device short name | PM5100 |
| Product or component type | Power meter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power quality analysis | up to the 15th harmonic |
| Device application | Power monitoring |
| Type of measurement | Current Voltage Frequency Power factor Energy Active and reactive power |
| supply voltage | 90...450 V AC 45...65 Hz 100...300 V DC |
| Network frequency | 60 Hz 50 Hz |
| [In] rated current | 5 A 1 A |
| type of network | 3P + N 1P + N 3P |
| Maximum power consumption in VA | 11 VA at 415 V |
| Ride-through time | 80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical 50 ms 125 V DC typical |
| Display type | Monochrome graphic LCD |
| Display resolution | 128 x 128 pixels |
| Sampling rate | 64 samples/cycle |
| Measurement current | 50â¦8500 mA |
| Analogue input type | Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm) |
| Measurement voltage | 35â¦760 V AC 45...65 Hz between phases 20â¦400 V AC 45...65 Hz between phase and neutral |
| Frequency measurement range | 45â¦65 Hz |
| Number of inputs | 0 |
| Measurement accuracy | Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.5 Current +/- 0.5 % Voltage +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 % |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
| Number of outputs | 1 pulse (energy) |
| Communication port protocol | - |
| Communication port support | - |
| Data recording | Min/max of instantaneous values Time stamping |
| Connections - terminals | Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 RS485 link: screw terminal block4 |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Standards | EN 50470-1 IEC 62053-22:2020 UL 61010-1 IEC 62053-24 IEC 61557-12:2015 EN 50470-3 IEC 60529 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 |
| Width | 96 mm |
| Depth | 72 mm |
| Height | 96 mm |
| Product weight | 380 g |

PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | PowerLogic PM3000 |
| Product or Component Type | Power meter |
| Device short name | PM3250 |
| Market segment | Buildings small building cost management: billing: sub feeder Buildings medium building cost management: billing: sub feeder Buildings large building cost management: billing: sub feeder Buildings multi-site cost management: billing: sub feeder Data center cost management: billing: sub feeder Healthcare cost management: billing: sub feeder Industry cost management: billing: sub feeder Buildings small building cost management: cost allocation: sub feeder Buildings medium building cost management: cost allocation: sub feeder Buildings large building cost management: cost allocation: sub feeder Buildings multi-site cost management: cost allocation: sub feeder Data center cost management: cost allocation: sub feeder Healthcare cost management: cost allocation: sub feeder Industry cost management: cost allocation: sub feeder |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power quality analysis | up to the 15th harmonic |
| Device Application | Multi-tariff Power monitoring Sub billing |
| Type of measurement | Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U) |
| supply voltage | 100...277 V AC 45...65 Hz 173...480 V AC 45...65 Hz 100...300 V DC |
| Network Frequency | 60 Hz 50 Hz |
| Line Rated Current | 5 A 1 A |
| type of network | 1P + N 3P 3P + N |
| Power Consumption in VA | 5 VA |
| Display Type | Backlit LCD |
| Display Resolution | 128 x 96 pixels |
| Sampling rate | 32 samples/cycle |
| Measurement current | 0.02â¦1.2 A 0.05â¦6 A |
| Analogue input type | Current 0...5 A Current 0...1 A |
| Measurement voltage | 50â¦330 V AC 45...65 Hz direct 50â¦330 V AC 45...65 Hz phase to neutral 80â¦570 V AC 45...65 Hz direct 80â¦570 V AC 45...65 Hz phase to phase 570â¦999000 V AC 45...65 Hz with external VT |
| Frequency measurement range | 45â¦65 Hz |
| Number of inputs | 0 |
| Measurement accuracy | Current 0.3 % 0.5...6 A Current 0.5 % 0.1...1.2 A Voltage 0.3 % 50...330 V Voltage 0.3 % 80...570 V |
| Accuracy class | Class 0.5S active energy IEC 62053-22 Class 1 active energy IEC 62053-21 Class 2 reactive energy IEC 62053-23 Class C active energy EN 50470-3 |
| Number of Outputs | 0 |
| Information displayed | Tariff 4) |
| Communication port protocol | Modbus 9.6...38.4 kbauds |
| Communication port support | RS485 |
| Data recording | Time stamping Min/max of instantaneous values 5 alarms |
| Mounting Mode | Clip-on |
| Mounting support | DIN rail |
| Standards | BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20 |
| Product certifications | CE IEC 61010-1 safety) CE EN 61557-12 power monitor) CE EN/IEC 61326-1 EMC) UKCA BS EN 61010-1 safety) UKCA BS EN 61557-12 power monitor) UKCA BS EN 61326-1 EMC) CULus EN 61010-1 safety) CULus UL 61010-1 safety) EAC sub-meter) RCM |
| Width | 3.5 in (90 mm) |
| Depth | 2.8 in (70 mm) |
| Height | 3.7 in (95 mm) |
| Product Weight | 0.57 lb(US) (0.26 kg) |
| Market Segment | Residential Small commercial |