
ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
94fc082b-5d76-4eeb-8e15-5bc418ea47af Italy
fa3b011f-e8ce-44e9-b47c-88318fee50f7 Germany
3ec8def3-26e1-4ea0-aa32-57f71b742262 Netherlands
75bbca28-e587-474a-9cd9-93bd683eb6bd Poland
0f3c025e-76a4-42f8-a532-77289e6ce527 France
7e0ca652-f8ae-4579-b473-9a158dafbc5c Sweden
bac36a39-01c4-4a6f-af9e-9b7161d1e1bc Germany
c51b95da-3991-4a00-8ef2-a296e7f49316 Germany
f63704f1-3070-4977-8e44-350fb8cf5b76 France
35ec6a18-d596-47b6-bac9-d899ecfe1a71 Netherlands
60ba9153-13fb-4c7d-847d-fd8687e3684f Spain
c22759bd-e767-42ec-a60c-4a0bf8d08046 Poland
8176d198-3736-4051-a517-95d2c29d4933 Norway
25687a92-dfaa-486f-9862-2989dc1e4d20 Finland
f63704f1-3070-4977-8e44-350fb8cf5b76 France
35ec6a18-d596-47b6-bac9-d899ecfe1a71 Netherlands
60ba9153-13fb-4c7d-847d-fd8687e3684f Spain
3ec8def3-26e1-4ea0-aa32-57f71b742262 Netherlands
35fcd6a6-24d8-4ae4-9584-618010b0dd12 Bulgaria
3bff1077-073c-4af5-8b20-c327726bb6ec Sweden
cfa3eca7-9354-475b-a8cf-e1ee7abe2bf0 Estonia
e6c36f1a-665b-4b63-aeed-1f21831af460 Greece
de8c84de-a508-41dd-a934-57ef560cec5e Portugal
7e0ca652-f8ae-4579-b473-9a158dafbc5c Sweden
bac36a39-01c4-4a6f-af9e-9b7161d1e1bc Germany
c51b95da-3991-4a00-8ef2-a296e7f49316 Germany
e6265f58-711e-4fd2-bef1-0881d3c8addf Netherlands
27c0fb6e-d769-4603-9bf6-3ff184b9c964 Germany
53a6811b-361d-42c0-8fdd-ceafeda65111 Denmark
b53d8468-4e87-491b-b3f7-b7aa24061656 Germany
9f412e57-8038-4a0e-81da-a6d522566174 Croatia
1d62ba95-6642-4c2c-ab93-b59bb2a2ee4d Czech Republic
4c6f5836-0888-465b-b68d-ffa17714d0df Poland
c22759bd-e767-42ec-a60c-4a0bf8d08046 Poland
8176d198-3736-4051-a517-95d2c29d4933 Norway
25687a92-dfaa-486f-9862-2989dc1e4d20 Finland
e6265f58-711e-4fd2-bef1-0881d3c8addf Netherlands
27c0fb6e-d769-4603-9bf6-3ff184b9c964 Germany
53a6811b-361d-42c0-8fdd-ceafeda65111 Denmark
b53d8468-4e87-491b-b3f7-b7aa24061656 Germany
9f412e57-8038-4a0e-81da-a6d522566174 Croatia
1d62ba95-6642-4c2c-ab93-b59bb2a2ee4d Czech Republic
4c6f5836-0888-465b-b68d-ffa17714d0df Poland
924d376e-341e-48de-a6bd-e4907f9d0cf8 Netherlands
d353cc07-7fe6-457f-a644-d0f476b52145 Netherlands
0f3c025e-76a4-42f8-a532-77289e6ce527 France
35fcd6a6-24d8-4ae4-9584-618010b0dd12 Bulgaria
3bff1077-073c-4af5-8b20-c327726bb6ec Sweden
75bbca28-e587-474a-9cd9-93bd683eb6bd Poland
924d376e-341e-48de-a6bd-e4907f9d0cf8 Netherlands
d353cc07-7fe6-457f-a644-d0f476b52145 Netherlands
cfa3eca7-9354-475b-a8cf-e1ee7abe2bf0 Estonia
e6c36f1a-665b-4b63-aeed-1f21831af460 Greece
de8c84de-a508-41dd-a934-57ef560cec5e Portugal
fa3b011f-e8ce-44e9-b47c-88318fee50f7 Germany
3ec8def3-26e1-4ea0-aa32-57f71b742262 Netherlands
75bbca28-e587-474a-9cd9-93bd683eb6bd Poland
0f3c025e-76a4-42f8-a532-77289e6ce527 France
7e0ca652-f8ae-4579-b473-9a158dafbc5c Sweden
bac36a39-01c4-4a6f-af9e-9b7161d1e1bc Germany
c51b95da-3991-4a00-8ef2-a296e7f49316 Germany
f63704f1-3070-4977-8e44-350fb8cf5b76 France
35ec6a18-d596-47b6-bac9-d899ecfe1a71 Netherlands
60ba9153-13fb-4c7d-847d-fd8687e3684f Spain
Environmental
Ordering
XT1NEN160AFF000XXX
3640535
8015644013202
1 piece
85362090
Dimensions
101.6 mm
130 mm
70 mm
1.4 kg
Container Information
box 1 piece
128 mm
135 mm
143 mm
1.54 kg
8015644013202
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 45.5 ... 80 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
4P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 15 W
160 A
50 / 60 Hz
8 kV
1600 A
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
160 A
690 V
Main Circuit M6
TMD
TM
112...160 A
N
IEC60947-2
XT1
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644561512
1 piece
85389099
Dimensions
0.853 kg
Container Information
1 piece
220 mm
30 mm
220 mm
0.9 kg
8015644561512
Additional Information
Accessories for Tmax T
Accessory
Accessory
T4
SACE Tmax T
Technical
Loose or configurable
4P
IEC
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

Technical
100 A
100 A
5 A
FS 5
5 V·A
Plug-in connection
Through-feed current converter
Primary 1
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20230928
No data - If REACH inform is not yet available for a certain product
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
IP20
Dimensions
0.065 m
0.075 m
0.100 m
0.187 kg
30 mm
Ordering
box 1 piece
0.217 kg
6701046
8261072
Certificates and Declarations
Installation
DIN-Rail
Popular Downloads
External Classifications and Standards
EC002048 - Current transformer
EC002048 - Current transformer
V11.0 : 27210902
T

Ordering
1 piece
85364900
Popular Downloads
Dimensions
45 mm
77 mm
86 mm
0.31 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Main Circuit 690 V
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
(690 V) 40 °C 30 A
(690 V) 60 °C 30 A
(690 V) 70 °C 26 A
(690 V) 40 °C 30 A
(690 V) 60 °C 30 A
(690 V) 70 °C 26 A
(415 V) 60 °C 18 A
(440 V) 60 °C 18 A
(500 V) 60 °C 15 A
(690 V) 60 °C 10.5 A
(380 / 400 V) 60 °C 18 A
(220 / 230 / 240 V) 60 °C 18 A
(415 V) 60 °C 18 A
(440 V) 60 °C 18 A
(500 V) 60 °C 15 A
(690 V) 60 °C 10.5 A
(380 / 400 V) 60 °C 18 A
(220 / 230 / 240 V) 60 °C 18 A
(400 V) 7.5 kW
(415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
(400 V) 7.5 kW
(415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
6 kV
(AC-1) 600 cycles per hour
3600 cycles per hour
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
at Rated Operating Conditions AC-1 per Pole 1.2 W
at Rated Operating Conditions AC-3 per Pole 0.35 W
at Rated Operating Conditions AC-1 per Pole 1.2 W
at Rated Operating Conditions AC-3 per Pole 0.35 W
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
2 x M4 Screws Placed Diagonally
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Control Circuit 10 mm
Main Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Control Circuit 1.2 N·m
Main Circuit 1.5 N·m
Control Circuit 1.2 N·m
Main Circuit 1.5 N·m
Screw Terminals
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 30 A
Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Environmental
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Category B according to IEC 60947-1 Annex Q
Without Derating 3000 m
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
4g Closed Position & 2g Open position 5 ... 300 Hz
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
83466862-a48a-4256-9e40-a34ec37345f8 China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Recycled Cardboard - 86 %
Recycled Metal - 28 %
Certificates and Declarations
Container Information
box 1 piece
87 mm
79 mm
47 mm
0.31 kg
3471523116733
box 27 piece
250 mm
300 mm
315 mm
16.74 kg
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3706356

Technical
E 90
Fuse holders
3
3P
3.5...4 N·m
Connecting and disconnecting under no-load conditions - occasional actuation (AC-20B)
Padlockable
Sealing Wire
Copper
With LED
Pozidriv 2
Rigid 4…35 mm²
Rigid Stranded|4…50 mm²
Rigid 4…35 mm²
Rigid Stranded|4…50 mm²
22x58 mm
max. 90% with temp. +20 °C|50% with max. temp. +40 °C
125 A
Electrical
acc. To IEC 690 V
acc. To UL 690 V
acc. To IEC 690 V
acc. To UL 690 V
AC-20B 690 V
1 kV
50/60 Hz
at Rated Operating Conditions per Pole 9.5 W
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
01/01/2014 0.00.00
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Storage -5...+40 °C
Storage Operation|-25...+70 °C
Storage -5...+40 °C
Storage Operation|-25...+70 °C
IP20
1 mm 2 … 13 Hz
15g 18 shocks 11 ms
Dimensions
6
105 mm
112 mm
73.26 mm
405 g
73.26 mm
Ordering
box 2 piece
0.54 kg
1416168
Certificates and Declarations
Installation
DIN-Rail
External Classifications and Standards
EC002705 - Holder for cylindrical fuse
EC002705 - Holder for cylindrical fuse
39121624
V11.0 : 27142121
4974 >> Holder for cylindrical fuse
F
BV
Korean register
CCC
EAC
BV
Korean register
CCC
EAC
UL

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2NSEJBK200A000000XX
8015644748494
1 piece
85362090
Dimensions
276 mm
371 mm
270 mm
41 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
46 kg
8015644748494
Additional Information
Technical
AC
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
136 W
1600 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
1600 A
690 V
Main Circuit M12
Ekip Hi-Touch LSIG
EL
N
IEC
E2.2
Yes, 690V
Rear flat Horizontal
Bolt
70 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644574765
1 piece
85362090
Dimensions
558 mm
461 mm
396.5 mm
81 kg
Container Information
1 piece
515 mm
600 mm
785 mm
96 kg
8015644574765
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
4P
350 W
2500 A
12 kV
1000 V
2500 A
690 V AC
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
for 1 s 65 kA
for 3 s 65 kA
for 1 s 65 kA
for 3 s 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
2500 A
690 V
PR121/P-LI
EL
N
IEC
E3
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
4. Large Equipment (Any External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KT6MI-V
8015644631970
1 piece
85389099
Dimensions
5.6 kg
Container Information
1 piece
350 mm
85 mm
830 mm
5.9 kg
8015644631970
Additional Information
Accessories for Tmax T
Accessory
Accessory
T6
SACE Tmax T
Technical
Loose or configurable
IEC
Certificates and Declarations
External Classifications and Standards
EC001044 - Mechanic interlock for switch
EC001044 - Mechanic interlock for switch
Q
39121100
4. Large Equipment (Any External Dimension More Than 50 cm)
V11.1 : 27371303

ABB
2CSK2240CH ABB - IP40 enclosure, 2 places, 2 modules width Grey - Chiara
Sale price€0,00
Sold OutInstallation
Wall-/ceiling mounting
Environmental
IP40
Technical
Design
Chiara
Square
Basic
Plastic
Mounting Cover
RAL 7035 - Light Grey
Grey
Dimensions
2
65 mm
60 m
55 mm
0.007 kg
Material Compliance
Certificates and Declarations
External Classifications and Standards
EC002600 - Box/housing for surface mounting on the wall/ceiling
EC002600 - Box/housing for surface mounting on the wall/ceiling

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z1BQEGAA000A000000XX
8015644759810
1 piece
85362090
Dimensions
278 mm
363.5 mm
271 mm
18 kg
Container Information
box 1 piece
270 mm
350 mm
330 mm
20 kg
8015644759810
Additional Information
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
156 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
100 %
for 1 s 42 kA
for 3 s 24 kA
for 1 s 42 kA
for 3 s 24 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
1000 A
690 V
Ekip Dip LI
EL
B
IEC
E1.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 56.30 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
4b451c7c-8583-4be9-8289-16ffac0488e9 China
Environmental
Ordering
XT4LE4250FFF000XXX
4380183
8015644024918
1 piece
85362090
Dimensions
140 mm
160 mm
82.5 mm
3.5 kg
Container Information
box 1 piece
145 mm
210 mm
168 mm
3.5 kg
8015644024918
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 85..200 mm²
AC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
4P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 16.4 W
250 A
50 / 60 Hz
8 kV
1000 V
690 V AC
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 50 kA
(690 V AC) 20 kA
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 50 kA
(690 V AC) 20 kA
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 50 kA
(690 V AC) 20 kA
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 50 kA
(690 V AC) 20 kA
250 A
690 V
Main Circuit M8
Ekip LSI
EL
L
IEC60947-2
XT4
Front
Bolt
8 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
4308991
8015644605650
1 piece
85389099
Dimensions
1 kg
Container Information
1 piece
0.4 kg
8015644605650
Additional Information
Accessories for Emax
Accessory
Accessory
E1, E2, E3, E4, E6
SACE Emax
Technical
Loose or configurable
IEC
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644233846
1 piece
85389099
Dimensions
1.067 kg
Container Information
1 piece
100 mm
70 mm
210 mm
1.067 kg
8015644233846
Additional Information
Accessories for Tmax T
Accessory
Accessory
S6
T6
S6
T6
SACE Tmax T
SACE Isomax
SACE Tmax T
SACE Isomax
Technical
S6 800 (3x185 mm2)
3P
IEC
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZANSEJBF000A000000XX
8015644753665
1 piece
85362090
Dimensions
280 mm
296 mm
183 mm
16 kg
Container Information
box 1 piece
350 mm
350 mm
330 mm
18 kg
8015644753665
Additional Information
Technical
AC
Ue =< 440 V 3000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
Ue =< 440 V 3000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
100 %
4P
201 W
1600 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
100 %
for 1 s 50 kA
for 3 s 30 kA
for 1 s 50 kA
for 3 s 30 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
1600 A
690 V
Main Circuit M10
Ekip Touch LSIG
EL
N
IEC
E1.2
Yes, 690V
Front
Bolt
45 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
Z1NMECBQ200A000000XX
8015644745509
1 piece
85362090
Dimensions
210 mm
296 mm
183 mm
14 kg
Container Information
box 1 piece
270 mm
350 mm
330 mm
16 kg
8015644745509
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
31 W
250 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
100 %
for 1 s 50 kA
for 3 s 30 kA
for 1 s 50 kA
for 3 s 30 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
250 A
690 V
Ekip G Hi-Touch LSIG
EL
N
IEC
E1.2
Yes, 690V
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
ZBNQEGAD000A000000XX
8015644767549
1 piece
85362090
Dimensions
407 mm
425 mm
383 mm
55 kg
Container Information
box 1 piece
515 mm
610 mm
615 mm
60 kg
8015644767549
Additional Information
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
100 %
4P
113 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
1000 A
690 V
Ekip Touch LI
EL
N
IEC
E2.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
e4ecbbb5-e237-4fd0-a64e-9f1f9abcbdb9 China
Environmental
Ordering
XT2SE3010FFF000XXX
4379419
8015644017064
1 piece
85362090
Dimensions
90 mm
130 mm
82.5 mm
1.2 kg
Container Information
box 1 piece
130 mm
208 mm
145 mm
1.22 kg
8015644017064
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 32.5..100 mm²
AC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 0.10 W
10 A
50/60 Hz
8 kV
1000 V AC
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
160 A
690 V AC
Main Circuit M6
Ekip C Dip LSI
EL
S
IEC60947-2
XT2
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT4DIN-4
4381081
8015644868567
1 piece
85389099
Dimensions
0.03 kg
Container Information
box 1 piece
145 mm
15 mm
200 mm
0.05 kg
8015644868567
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT4
Technical
Loose or configurable
4P
1 piece
IEC60947-2
Certificates and Declarations
External Classifications and Standards
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
3012 >> Electrical fixture brackets
31162504
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371390






