1SDA056475R1 ABB - E3H2500PR122/P-LIIn=2500A4pFHR

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644578152
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
530 mm
Product Net Height:
418 mm
Product Net Depth / Length:
302 mm
Product Net Weight:
76 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
785 mm
Package Level 1 Gross Weight:
90 kg
Package Level 1 EAN:
8015644578152

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
205 W
Rated Current (In):
2500 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
2500 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 75 kA
for 3 s 65 kA
for 1 s 75 kA
for 3 s 65 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Uninterrupted Current (Iu):
2500 A
Rated Voltage (Ur):
690 V
Release:
PR122/P-LI
Release Type:
EL
Short-Circuit Performance Level:
H
Standards:
IEC
Sub-type:
E3
Terminal Connection Type:
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)
7TCG009460R0102 ABB - TY5272MR
ABB 7TCG009460R0102 ABB - TY5272MR
Sale price€0,00
Sold Out

Eco Transparency

Environmental Product Declaration - EPD:

Ordering

EAN:
5414363065760
UPC:
786210613789
Minimum Order Quantity:
50 piece
Country or Territory of Origin:
Hungary
Selling Unit of Measure:
each

Container Information

Package Level 1 Units:
50 piece
Package Level 1 EAN:
05414363065760
Package Level 2 Units:
5000 piece
Package Level 2 Width:
15.4 in
391 mm
15.4 in
391 mm
Package Level 2 Height:
11 in
279 mm
11 in
279 mm
Package Level 2 Depth / Length:
23.6 in
599 mm
23.6 in
599 mm

Technical UL/CSA

Flammability According to UL94:
V-2

Additional Information

Brand / Label:
Ty-Rap
Color:
Natural
Effective Date:
19980621
Lock Type:
Stainless Steel Barb
Material:
Nylon/Polyamide 6.6
Order Multiple:
50 piece
Product Main Type:
PERFORMANCE CABLE TIES AND ACCESSORIES
Product Name:
TY-RAP FASTENING
Tensile Strength:
120 lb
540 N
120 lb
540 N
Thickness:
0.07 in
1.78 mm
0.07 in
1.78 mm

External Classifications and Standards

ETIM 7:
EC000046 - Cable tie
ETIM 8:
EC000046 - Cable tie
ETIM 9:
EC000046 - Cable tie
ETIM 10:
EC000046 - Cable tie
UNSPSC:
39121703
IDEA Granular Category Code (IGCC):
5034 >> Cable ties

Material Compliance

RoHS Information:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH Information:
False - does not contain substances > 0.1 mass percentage
WEEE Category:
Product Not in WEEE Scope
1SBK134037R1400 ABB - DRAF09-14P 250-500V50/60HZ

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Product Main Type:
DRAF09

Dimensions

Product Net Width:
107 mm
Product Net Depth / Length:
131 mm
Product Net Height:
230 mm
Product Net Weight:
0.82 kg

Technical

Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 60 Hz 250 V·A
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Housing Material:
ABS
Number of Auxiliary Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Main Contacts NC:
0
Number of Main Contacts NO:
3
Number of Poles:
3P
Pollution Degree:
3
Rated Control Circuit Voltage (Uc):
50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 25 A
(690 V) 60 °C 25 A
(690 V) 70 °C 22 A
(690 V) 40 °C 25 A
(690 V) 60 °C 25 A
(690 V) 70 °C 22 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe):
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-3e (Pe):
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
Terminal Type:
Screw Terminals

Technical UL/CSA

Pilot Duty UL/CSA:
A600
Q600
A600
Q600

Material Compliance

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
243 mm
Package Level 1 Depth / Length:
112 mm
Package Level 1 Height:
143 mm
Package Level 1 Gross Weight:
0.82 kg
Package Level 1 EAN:
3471522144843

External Classifications and Standards

eClass:
V11.0 : 27371205
E-Number (Finland):
3709751
ETIM 6:
EC000200 - Enclosure for control circuit devices
ETIM 7:
EC000200 - Enclosure for control circuit devices
ETIM 8:
EC000200 - Enclosure for control circuit devices
ETIM 9:
EC000200 - Enclosure for control circuit devices
IDEA Granular Category Code (IGCC):
4727 >> Motor starter controls
UNSPSC:
39121521
1SDA057831R1 ABB - E4S-A 3200 PR122/P-LSI In=3200A 3p F HR

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644600945
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
566 mm
Product Net Height:
418 mm
Product Net Depth / Length:
302 mm
Product Net Weight:
81 kg

Container Information

Package Level 1 EAN:
8015644600945

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
CB
Version:
F

Technical

Current Type:
AC
Electrical Durability:
Ue =< 508 V 5000 cycle
Ue = 508 ... 635 V 5000 cycle
30 cycles per hour
Ue =< 508 V 5000 cycle
Ue = 508 ... 635 V 5000 cycle
30 cycles per hour
Mechanical Durability:
8000 cycle
30 cycles per hour
8000 cycle
30 cycles per hour
Number of Poles:
3P
Power Loss:
at Rated Operating Conditions per Pole 230 W
Rated Current (In):
3200 A
Rated Operational Current (Ie):
3200 A
Rated Service Short-Circuit Breaking Capacity (Ics):
(240 V AC) 85 kA
(480 V AC) 65 kA
(600 V AC) 65 kA
(240 V AC) 85 kA
(480 V AC) 65 kA
(600 V AC) 65 kA
Rated Uninterrupted Current (Iu):
3200 A
Rated Voltage (Ur):
600 V
Release:
PR122/P-LSI
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
UL 1066
Sub-type:
E4
Terminal Connection Type:
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal

Technical UL/CSA

Interrupting Rating acc. to UL1066:
(240 V AC) 85 kA
(480 V AC) 65 kA
(600 V AC) 65 kA
(240 V AC) 85 kA
(480 V AC) 65 kA
(600 V AC) 65 kA

Certificates and Declarations

External Classifications and Standards

WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)
ABB Stock Image
ABB 1SBL901074R8110 ABB
Sale price€0,00
Sold Out
Buy the ABB 1SBL901074R8110 - a genuine ABB industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The ABB 1SBL901074R8110 is a direct drop-in replacement for existing installations and ships ready for integration.
1SBV010351R1211 ABB - LS32P51B11
ABB 1SBV010351R1211 ABB - LS32P51B11
Sale price€0,00
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:

Dimensions

Product Net Width:
30 mm
Product Net Height:
98.5 mm
Product Net Depth / Length:
45.5 mm
Product Net Weight:
0.092 kg

Technical

Action Type of the Contact Element (acc. to IEC 60947-5-1):
Snap Action Simultaneous
Actuator Type:
adjustable plastic roller lever (Ø18 mm)
B10d Value:
Operations 30 Millions
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Degree of Protection:
acc. to IEC 60529 IP65
Housing Material:
Plastic
Maximum Electrical Switching Frequency:
(AC-15) 3600 cycles per hour
(DC-13) 3600 cycles per hour
(AC-15) 3600 cycles per hour
(DC-13) 3600 cycles per hour
Maximum Mounted Auxiliary Contacts:
1 NO, 1 NC
Mechanical Durability:
10 million
Mounting Type:
30 mm (EN 50047)
Number and Type of Bottom Cable Glands:
1 x M16x1.5 - Bottom
Pilot Duty UL/CSA:
A600
Q600
A600
Q600
Rated Impulse Withstand Voltage (Uimp):
6 kV
Rated Operational Current AC-15 (Ie):
(230 V AC) 3.1 A
(400 V) NC 4
(24 V) 10 A
(130 V) 5.5 A
(240 V) 3 A
(230 V AC) 3.1 A
(400 V) NC 4
(24 V) 10 A
(130 V) 5.5 A
(240 V) 3 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V
acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V
acc. to UL/CSA 600 V
Rated Operational Current DC-13 (Ie):
(24 V) 6 A
(110 V) 0.6 A
(125 V) 0.55 A
(250 V) 0.4 A
(24 V) 6 A
(110 V) 0.6 A
(125 V) 0.55 A
(250 V) 0.4 A
Short-Circuit Protective Devices:
gG Type Fuses 10 A

Environmental

Ambient Air Temperature:
Operation -25 ... +70 °C
Storage -30 ... +80 °C
Operation -25 ... +70 °C
Storage -30 ... +80 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
54 mm
Package Level 1 Depth / Length:
32 mm
Package Level 1 Height:
118 mm
Package Level 1 Gross Weight:
0.106 kg
Package Level 1 EAN:
3471522000453

External Classifications and Standards

Object Classification Code:
B
ETIM 6:
EC000030 - End switch
ETIM 7:
EC000030 - End switch
ETIM 8:
EC000030 - End switch
eClass:
V11.0 : 27272601
UNSPSC:
39121500
ABB New Stock Image
ABB 1SDA073756R1 ABB
Sale price €166,95
Only 7 units left

ABB EcoSolutions

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
ZEBAUX6
EAN:
8015644776893
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Weight:
0.2 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
220 mm
Package Level 1 Height:
40 mm
Package Level 1 Depth / Length:
500 mm
Package Level 1 Gross Weight:
0.2 kg
Package Level 1 EAN:
8015644776893

Additional Information

Product Main Type:
Accessories for Emax 2
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
E2.2, E4.2, E6.2
Suitable for Product Class:
SACE Emax 2

Technical

Configuration Type:
Mounted only
Number of Auxiliary Contacts CO (SPDT):
6
Remarks:
Extracode
Standards:
IEC

External Classifications and Standards

ETIM 9:
EC000041 - Auxiliary contact block
ETIM 10:
EC000041 - Auxiliary contact block
IDEA Granular Category Code (IGCC):
4743 >> Auxiliary contact block
Object Classification Code:
Q
UNSPSC:
39121522
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27371302
1SDA070765R1 ABB - E1.2N 800 Ekip Touch LSI 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 76.4 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
f0aac47d-5f25-440e-8893-a91bf8913c47 Italy
Simplified SCIP:
c4dea726-8d03-4dd9-a384-8820196e4d29 France
946ce6dd-e65c-4877-a9ec-d9518dab0222 Estonia
9c256df3-4bba-4ba0-868e-c5a2761c1804 Spain
d6669862-c900-41f1-8f3c-311b1a352606 Bulgaria
93ced8bc-3f6d-41d7-8a4e-30f49aa0ce0c Czech Republic
8e5241c4-277f-4155-9c22-b88035e9658e Hungary
946ce6dd-e65c-4877-a9ec-d9518dab0222 Estonia
664da7d8-ced9-4cca-a0a8-be5204739862 Poland
a0b977b4-73a3-462f-9b4c-7045ea01dfec Germany
838d5893-c1cb-4b6f-84de-6f4683df18e6 Sweden
4d1938e7-6ae4-4f1c-b897-d1fee1d038bf France
80b34637-aa66-4276-9b84-03a30ef0052e Poland
9d1d3e6d-c738-4b12-ae0c-0f341c052649 Sweden
9c256df3-4bba-4ba0-868e-c5a2761c1804 Spain
ebe6a6ec-faa5-4a97-86e3-c3bc69b614c3 Germany
c4dea726-8d03-4dd9-a384-8820196e4d29 France
ec47aa9d-0ed8-487d-bab2-781fd37d9682 Hungary
d7732256-8ac1-41e6-9817-3849ab3031bd Belgium
d7732256-8ac1-41e6-9817-3849ab3031bd Belgium
a08450f4-804b-4a67-b15d-9914e2fd2372 Belgium
99b0dafd-f7e8-4116-928c-8f50cbd5f858 Norway
69f2b450-9f87-457e-91b7-e1f7acc9886d Germany
d6669862-c900-41f1-8f3c-311b1a352606 Bulgaria
b2a82559-5df8-42ff-9407-83ef6ce76ee3 Germany
9d1d3e6d-c738-4b12-ae0c-0f341c052649 Sweden
f2df3df0-b281-474e-b404-771d002c6de4 Finland
1f10f9c3-ab94-4298-86bf-681bbbfe2a3d Denmark
80b34637-aa66-4276-9b84-03a30ef0052e Poland
ac8ac188-87ca-4aba-95dc-41d8d3802b93 Greece
949df4e5-c0a6-4e97-8313-7bedc4d2cf2a Poland
ec47aa9d-0ed8-487d-bab2-781fd37d9682 Hungary
1f10f9c3-ab94-4298-86bf-681bbbfe2a3d Denmark
b05f338e-00b5-43eb-9738-37339e12a394 Germany
69f2b450-9f87-457e-91b7-e1f7acc9886d Germany
a08450f4-804b-4a67-b15d-9914e2fd2372 Belgium
15870914-28e8-47a8-b96f-04d609dfcf2b Croatia
8e5241c4-277f-4155-9c22-b88035e9658e Hungary
838d5893-c1cb-4b6f-84de-6f4683df18e6 Sweden
f69c2b5b-db5c-4597-916e-d498919255d8 Portugal
e7e3a98e-1d38-4046-ad3c-3804c1573747 Netherlands
15870914-28e8-47a8-b96f-04d609dfcf2b Croatia
a0b977b4-73a3-462f-9b4c-7045ea01dfec Germany
ebe6a6ec-faa5-4a97-86e3-c3bc69b614c3 Germany
99b0dafd-f7e8-4116-928c-8f50cbd5f858 Norway
b05f338e-00b5-43eb-9738-37339e12a394 Germany
4d1938e7-6ae4-4f1c-b897-d1fee1d038bf France
b2a82559-5df8-42ff-9407-83ef6ce76ee3 Germany
f2df3df0-b281-474e-b404-771d002c6de4 Finland
93ced8bc-3f6d-41d7-8a4e-30f49aa0ce0c Czech Republic
949df4e5-c0a6-4e97-8313-7bedc4d2cf2a Poland
e7e3a98e-1d38-4046-ad3c-3804c1573747 Netherlands
664da7d8-ced9-4cca-a0a8-be5204739862 Poland
f69c2b5b-db5c-4597-916e-d498919255d8 Portugal
ac8ac188-87ca-4aba-95dc-41d8d3802b93 Greece
c4dea726-8d03-4dd9-a384-8820196e4d29 France
946ce6dd-e65c-4877-a9ec-d9518dab0222 Estonia
9c256df3-4bba-4ba0-868e-c5a2761c1804 Spain
d6669862-c900-41f1-8f3c-311b1a352606 Bulgaria
93ced8bc-3f6d-41d7-8a4e-30f49aa0ce0c Czech Republic
8e5241c4-277f-4155-9c22-b88035e9658e Hungary
946ce6dd-e65c-4877-a9ec-d9518dab0222 Estonia
664da7d8-ced9-4cca-a0a8-be5204739862 Poland
a0b977b4-73a3-462f-9b4c-7045ea01dfec Germany
838d5893-c1cb-4b6f-84de-6f4683df18e6 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z1NPEFBE000A000000XX
EAN:
8015644746155
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
210 mm
Product Net Height:
296 mm
Product Net Depth / Length:
183 mm
Product Net Weight:
14 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
270 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
330 mm
Package Level 1 Gross Weight:
16 kg
Package Level 1 EAN:
8015644746155

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
50 W
Rated Current (In):
800 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 50 kA
for 3 s 30 kA
for 1 s 50 kA
for 3 s 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
Rated Uninterrupted Current (Iu):
800 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M10
Release:
Ekip Touch LSI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E1.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
45 N·m

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SBL347001R1300 ABB AF40-30-00-13
ABB 1SBL347001R1300 ABB AF40-30-00-13
Sale price €120,95
Only 9 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.95 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 70 A
(690 V) 60 °C 60 A
(690 V) 70 °C 50 A
(690 V) 40 °C 70 A
(690 V) 60 °C 60 A
(690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 40 A
(440 V) 60 °C 40 A
(500 V) 60 °C 35 A
(690 V) 60 °C 25 A
(380 / 400 V) 60 °C 40 A
(220 / 230 / 240 V) 60 °C 40 A
(415 V) 60 °C 40 A
(440 V) 60 °C 40 A
(500 V) 60 °C 35 A
(690 V) 60 °C 25 A
(380 / 400 V) 60 °C 40 A
(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 40 A
(440 V) 60 °C 40 A
(500 V) 60 °C 35 A
(690 V) 60 °C 25 A
(380 / 400 V) 60 °C 40 A
(220 / 230 / 240 V) 60 °C 40 A
(415 V) 60 °C 40 A
(440 V) 60 °C 40 A
(500 V) 60 °C 35 A
(690 V) 60 °C 25 A
(380 / 400 V) 60 °C 40 A
(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 70 A
(110 V) 2 Poles in Series, 60 °C 60 A
(110 V) 2 Poles in Series, 70 °C 50 A
(110 V) 3 Poles in Series, 40 °C 70 A
(110 V) 3 Poles in Series, 60 °C 60 A
(110 V) 3 Poles in Series, 70 °C 50 A
(220 V) 3 Poles in Series, 40 °C 70 A
(220 V) 3 Poles in Series, 60 °C 60 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 70 A
(72 V) 1-Pole, 60 °C 60 A
(72 V) 1-Pole, 70 °C 50 A
(72 V) 2 Poles in Series, 40 °C 70 A
(72 V) 2 Poles in Series, 60 °C 60 A
(72 V) 2 Poles in Series, 70 °C 50 A
(72 V) 3 Poles in Series, 40 °C 70 A
(72 V) 3 Poles in Series, 60 °C 60 A
(72 V) 3 Poles in Series, 70 °C 50 A
(110 V) 2 Poles in Series, 40 °C 70 A
(110 V) 2 Poles in Series, 60 °C 60 A
(110 V) 2 Poles in Series, 70 °C 50 A
(110 V) 3 Poles in Series, 40 °C 70 A
(110 V) 3 Poles in Series, 60 °C 60 A
(110 V) 3 Poles in Series, 70 °C 50 A
(220 V) 3 Poles in Series, 40 °C 70 A
(220 V) 3 Poles in Series, 60 °C 60 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 70 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 70 A
(110 V) 2 Poles in Series, 60 °C 60 A
(110 V) 2 Poles in Series, 70 °C 50 A
(110 V) 3 Poles in Series, 40 °C 70 A
(110 V) 3 Poles in Series, 60 °C 60 A
(110 V) 3 Poles in Series, 70 °C 50 A
(220 V) 3 Poles in Series, 40 °C 70 A
(220 V) 3 Poles in Series, 60 °C 60 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 70 A
(72 V) 1-Pole, 60 °C 60 A
(72 V) 1-Pole, 70 °C 50 A
(72 V) 2 Poles in Series, 40 °C 70 A
(72 V) 2 Poles in Series, 60 °C 60 A
(72 V) 2 Poles in Series, 70 °C 50 A
(72 V) 3 Poles in Series, 40 °C 70 A
(72 V) 3 Poles in Series, 60 °C 60 A
(72 V) 3 Poles in Series, 70 °C 50 A
(110 V) 2 Poles in Series, 40 °C 70 A
(110 V) 2 Poles in Series, 60 °C 60 A
(110 V) 2 Poles in Series, 70 °C 50 A
(110 V) 3 Poles in Series, 40 °C 70 A
(110 V) 3 Poles in Series, 60 °C 60 A
(110 V) 3 Poles in Series, 70 °C 50 A
(220 V) 3 Poles in Series, 40 °C 70 A
(220 V) 3 Poles in Series, 60 °C 60 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 70 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 70 A
(110 V) 2 Poles in Series, 60 °C 60 A
(110 V) 2 Poles in Series, 70 °C 50 A
(110 V) 3 Poles in Series, 40 °C 70 A
(110 V) 3 Poles in Series, 60 °C 60 A
(110 V) 3 Poles in Series, 70 °C 50 A
(220 V) 3 Poles in Series, 40 °C 70 A
(220 V) 3 Poles in Series, 60 °C 60 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 70 A
(72 V) 1-Pole, 60 °C 60 A
(72 V) 1-Pole, 70 °C 50 A
(72 V) 2 Poles in Series, 40 °C 70 A
(72 V) 2 Poles in Series, 60 °C 60 A
(72 V) 2 Poles in Series, 70 °C 50 A
(72 V) 3 Poles in Series, 40 °C 70 A
(72 V) 3 Poles in Series, 60 °C 60 A
(72 V) 3 Poles in Series, 70 °C 50 A
(110 V) 2 Poles in Series, 40 °C 70 A
(110 V) 2 Poles in Series, 60 °C 60 A
(110 V) 2 Poles in Series, 70 °C 50 A
(110 V) 3 Poles in Series, 40 °C 70 A
(110 V) 3 Poles in Series, 60 °C 60 A
(110 V) 3 Poles in Series, 70 °C 50 A
(220 V) 3 Poles in Series, 40 °C 70 A
(220 V) 3 Poles in Series, 60 °C 60 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 70 A
Rated Operational Power AC-3 (Pe):
(400 V) 18.5 kW
(415 V) 22 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
(400 V) 18.5 kW
(415 V) 22 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe):
(415 V) 22 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
(415 V) 22 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 3 W
at Rated Operating Conditions AC-3 per Pole 1 W
at Rated Operating Conditions AC-1 per Pole 3 W
at Rated Operating Conditions AC-3 per Pole 1 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
2
Continuous Current Rating NEMA:
45 A
Horsepower Rating NEMA:
(115 V AC) Single Phase 3 Hp
(200 V AC) Three Phase 10 Hp
(230 V AC) Single Phase 7-1/2 Hp
(230 V AC) Three Phase 15 Hp
(460 V AC) Three Phase 25 Hp
(575 V AC) Three Phase 25 Hp
(115 V AC) Single Phase 3 Hp
(200 V AC) Three Phase 10 Hp
(230 V AC) Single Phase 7-1/2 Hp
(230 V AC) Three Phase 15 Hp
(460 V AC) Three Phase 25 Hp
(575 V AC) Three Phase 25 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 60 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 10 hp
(220 ... 240 V AC) Three Phase 15 hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 30 hp
(550 ... 600 V AC) Three Phase 40 hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 10 hp
(220 ... 240 V AC) Three Phase 15 hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 30 hp
(550 ... 600 V AC) Three Phase 40 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 32.2 A
(220 ... 240 V AC) Three Phase 42 A
(240 V AC) Single Phase 40 A
(440 ... 480 V AC) Three Phase 41 A
(550 ... 600 V AC) Three Phase 40 A
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 32.2 A
(220 ... 240 V AC) Three Phase 42 A
(240 V AC) Single Phase 40 A
(440 ... 480 V AC) Three Phase 41 A
(550 ... 600 V AC) Three Phase 40 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
32002722-9adc-4d60-b9d4-fa0b8941454b France
Simplified SCIP:
0363edf7-0705-44a2-a8db-ee90992e79a1 Sweden
d347bfae-af24-49a5-9ac4-d3c66bd7a51e France
b04fda13-35c3-4bf8-b80f-ef0c636f4283 Poland
92761cb3-4806-43ed-bb04-43f235c34c1b Sweden
c40e5db5-f20b-4c32-a229-6cf5aea0dd62 Germany
643255ac-732c-4217-a174-297f27f05bb4 Germany
5138f2a4-8987-4bcf-978f-852d159d58f4 Bulgaria
264668cf-87a9-4865-9054-46f8a01e0c49 Belgium
99d618a8-d94a-40d6-9d4c-1abd02a9b378 Portugal
d68760d3-4322-4e34-9b65-2bbe53486d0c Hungary
116de3e1-3a7a-44ea-b3da-51694ac449e4 Norway
12ccfd45-e1f4-4361-b19b-67e01f179859 Poland
ed30a39e-b3e4-4980-929c-5c63a3dda5cd Spain
9ab5e309-fcae-4c72-94ea-43020b9a4974 Germany
bc54b264-f551-4b51-9205-c62bbdc47bd2 Greece
7081aa9a-8f64-4f20-8608-b8877e1bffb4 Netherlands
9c345ac9-8727-40cb-b336-e32b39d4b635 Italy
860630b9-3860-4680-915e-c63ecc0003ab Finland
4af1b451-efda-4f5d-9103-35dda7c1d117 Germany
707f923c-0f2d-43e4-b4a0-c4f1abb2eb8b Denmark
b54a6a98-667d-4aa8-ab40-b64fb4f13047 Poland
d71e326b-49ee-4ffc-9f13-f66fcf2c0520 Czech Republic
3f1087ca-7321-4583-a272-14b4362f7319 Germany
0363edf7-0705-44a2-a8db-ee90992e79a1 Sweden
d347bfae-af24-49a5-9ac4-d3c66bd7a51e France
b04fda13-35c3-4bf8-b80f-ef0c636f4283 Poland
92761cb3-4806-43ed-bb04-43f235c34c1b Sweden
c40e5db5-f20b-4c32-a229-6cf5aea0dd62 Germany
643255ac-732c-4217-a174-297f27f05bb4 Germany
5138f2a4-8987-4bcf-978f-852d159d58f4 Bulgaria
264668cf-87a9-4865-9054-46f8a01e0c49 Belgium
99d618a8-d94a-40d6-9d4c-1abd02a9b378 Portugal
d68760d3-4322-4e34-9b65-2bbe53486d0c Hungary
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.05 kg
Package Level 1 EAN:
3471523132030
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.5 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3706599
E-Number (Sweden):
3210033
1SDA050692R1 ABB - KIT ES UP T6 - S6 3pcs

ABB EcoSolutions

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

E-Number (Finland):
3655704
E-Number (Norway):
4383569
EAN:
8015644509842
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Weight:
1.883 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
280 mm
Package Level 1 Height:
40 mm
Package Level 1 Depth / Length:
300 mm
Package Level 1 Gross Weight:
1.883 kg
Package Level 1 EAN:
8015644509842

Additional Information

Product Main Type:
Accessories for Tmax T
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
S6, T6
Suitable for Product Class:
SACE Tmax T
SACE Isomax
SACE Tmax T
SACE Isomax

Technical

Configuration Type:
Loose or configurable
Device:
S6
Number of Poles:
3P
Standards:
IEC

External Classifications and Standards

ETIM 9:
EC002019 - Connection vane/phase spreader
ETIM 10:
EC002019 - Connection vane/phase spreader
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27371305
1SDA055946R1 ABB - E2N2000PR121/P-LSIGIn=2000A4pWMP

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644572860
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
414 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
61 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
73 kg
Package Level 1 EAN:
8015644572860

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
330 W
Rated Current (In):
2000 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
2000 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
Rated Uninterrupted Current (Iu):
2000 A
Rated Voltage (Ur):
690 V
Release:
PR121/P-LSIG
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E2
Terminal Connection Type:
Withdrawable Circuit-Breakers

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
1SDA067660R1 ABB - XT2L 160 TMD 20-300 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2LE4020BFF000XXX
E-Number (Norway):
4379630
EAN:
8015644015565
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
120 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.45 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
131 mm
Package Level 1 Height:
212 mm
Package Level 1 Depth / Length:
147 mm
Package Level 1 Gross Weight:
1.55 kg
Package Level 1 EAN:
8015644015565

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 1.62 W
Rated Current (In):
20 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
300 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 36 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 85 kA
(500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 36 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 85 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 36 kA
(690 V AC) 18 kA
(250 V DC) 2 Poles in Series 85 kA
(500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA
(230 V AC) 150 kA
(240 V AC) 150 kA
(380 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 60 kA
(525 V AC) 36 kA
(690 V AC) 18 kA
(250 V DC) 2 Poles in Series 85 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
14...20 A
Short-Circuit Performance Level:
L
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA057419R1 ABB - E3N-A 2500 PR122/P-LSIG In=2500A 3p F HR

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644596828
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
404 mm
Product Net Height:
418 mm
Product Net Depth / Length:
302 mm
Product Net Weight:
60 kg

Container Information

Package Level 1 EAN:
8015644596828

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
CB
Version:
F

Technical

Current Type:
AC
Electrical Durability:
Ue =< 508 V 8000 cycle
Ue = 508 ... 635 V 8000 cycle
30 cycles per hour
Ue =< 508 V 8000 cycle
Ue = 508 ... 635 V 8000 cycle
30 cycles per hour
Mechanical Durability:
15000 cycle
30 cycles per hour
15000 cycle
30 cycles per hour
Number of Poles:
3P
Power Loss:
at Rated Operating Conditions per Pole 205 W
Rated Current (In):
2500 A
Rated Operational Current (Ie):
2500 A
Rated Service Short-Circuit Breaking Capacity (Ics):
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
Rated Uninterrupted Current (Iu):
2500 A
Rated Voltage (Ur):
600 V
Release:
PR122/P-LSIG
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
UL 1066
Sub-type:
E3
Terminal Connection Type:
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal

Technical UL/CSA

Interrupting Rating acc. to UL1066:
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA

Certificates and Declarations

External Classifications and Standards

WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
1SDA013866R1 ABB - CONNECTOR SOR-UVR L=1MT S3-S4-S5-S6 P/W

Environmental

Environmental Information:

Ordering

EAN:
8015644138660
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Width:
110 mm
Product Net Height:
60 mm
Product Net Depth / Length:
0.14 m
Product Net Weight:
0.075 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Height:
60 mm
Package Level 1 Depth / Length:
110 mm
Package Level 1 Gross Weight:
0.075 kg
Package Level 1 EAN:
8015644138660

Additional Information

Product Main Type:
Spare Parts
Product Name:
Accessory
Suitable For:
S3
S4
S5
S6
S3
S4
S5
S6
Suitable for Product Class:
Isomax

Technical

Device:
S3-S4-S5-S6

Certificates and Declarations

Data Sheet, Technical Information:
Declaration of Conformity - CE:
Instructions and Manuals:

External Classifications and Standards

Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
1SDA067830R1 ABB - XT2S 160 Ekip M-I In=32A 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2SE3032KFF000XXX
E-Number (Norway):
4379425
EAN:
8015644017262
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
90 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.12 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
131 mm
Package Level 1 Height:
212 mm
Package Level 1 Depth / Length:
147 mm
Package Level 1 Gross Weight:
1.22 kg
Package Level 1 EAN:
8015644017262

Additional Information

Circuit Breaker Type to be Associated:
Motor Protection
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 0.7 W
Rated Current (In):
32 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
Ekip M-I
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
2CSK2255CH ABB
ABB 2CSK2255CH ABB
Sale price€0,00
Sold Out

Installation

Instructions and Manuals:
Mounting Type:
Wall-/ceiling mounting

Environmental

Degree of Protection:
IP55

Technical

Data Sheet, Technical Information:
Number of Conduit Inlets:
2
Cover Mounting Type:
Hinged
Entrance Type:
Type of housing feed-through: Seal membrane
Illumination:
Non-illuminated
Includes:
Clamp

Design

Design Range:
Chiara
Shape:
Square
Surface Finishing:
Basic
Material:
Plastic
Cover Style:
Blind Cover
RAL Number:
RAL 7035 - Light Grey
Color:
Grey

Dimensions

Width in Number of Modular Spacings:
2
Product Net Width:
65 mm
Product Net Height:
60 m
Product Net Depth / Length:
63 mm
Product Net Weight:
0.01 kg

Material Compliance

Conflict Minerals Reporting Template (CMRT):
WEEE Category:
Product Not in WEEE Scope
WEEE B2C / B2B:
Business To Consumer

Certificates and Declarations

Declaration of Conformity - CE:

External Classifications and Standards

ETIM 9:
EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM 10:
EC002600 - Box/housing for surface mounting on the wall/ceiling
7TCA085400R0292 ABB - OVR CAT-6/POE
ABB 7TCA085400R0292 ABB - OVR CAT-6/POE
Sale price€0,00
Sold Out

Technical

Suitable For:
To protect systems against transient overvoltages or surges from lightning and electrical switching events
Nominal AC Voltage of the System (Uo):
58 V
Maximum Continuous Operating Voltage (Uc):
58 V
Discharge Current:
I (max, 8 / 20 µs) 10 kA
Number of Protected Poles:
1
Connection Type:
Push-In
Serial Resistance:
1.5 Ω

Electrical

Voltage Protection Level ( Up):
87 V
Rated Current (In):
600 mA

Material Compliance

RoHS Information:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH Information:
False - does not contain substances > 0.1 mass percentage
REACH Date:
20230117
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -40 ... +80 °C

Dimensions

Width in Number of Modular Spacings:
1
Product Net Width:
240 mm
Product Net Height:
60 mm
Product Net Depth / Length:
106 mm
Product Net Weight:
0.15 kg

Ordering

Package Level 1 Units:
1 piece

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Popular Downloads

Data Sheet, Technical Information:

External Classifications and Standards

ETIM 9:
EC000943 - Surge protection device for data networks/MCR-technology
ETIM 10:
EC000943 - Surge protection device for data networks/MCR-technology
Standards:
IEC 61643-21
1SDA072242R1 ABB - E2.2N 800 Ekip Dip LSI 3p WMP

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z2NPEFAB000A000000XX
EAN:
8015644760922
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
317 mm
Product Net Height:
425 mm
Product Net Depth / Length:
383 mm
Product Net Weight:
48 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
515 mm
Package Level 1 Gross Weight:
53 kg
Package Level 1 EAN:
8015644760922

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
72 W
Rated Current (In):
800 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
Rated Uninterrupted Current (Iu):
800 A
Rated Voltage (Ur):
690 V
Release:
Ekip Dip LSI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SBL161001R8110 ABB - A12-30-10 24V 50Hz / 24V 60Hz

A12-30-10 24V 50Hz / 24V 60Hz Contactor

E2N2000PR121/P-LIIn=2000A4pWMP ABB - 1SDA055944R1

E2N 2000 PR121/P-LI In=2000A 4p W MP

1SDA066808R1 ABB - XT1B 160 TMD 125-1250 3p F F
ABB 1SDA066808R1 ABB - XT1B 160 TMD 125-1250 3p F F
Sale price €135,95
In stock, 12 units

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
6774955b-d880-4def-9c74-19a93e0bae4c Italy
Simplified SCIP:
c9218e91-3702-48c7-bafc-2a74747ba1b2 Germany
0d2150b0-2b95-48d1-ab50-aaa310de7cb0 Poland
cee9d778-423b-4301-9f27-16e26d8be184 Norway
6b8f38c8-1ec2-4c2b-beeb-31ed145d161d Finland
dcaf512d-d6f7-4e34-8d7c-982d94a7f49c Netherlands
97a89143-ee64-45d0-a21b-cfae8450263a Germany
2f5e5e2f-ab8d-4466-a2bd-3cb87ff7223e Denmark
2a4f90b7-7165-43c0-87f0-06e205cbb250 Germany
556152b5-5ed1-4bb6-90d2-a8846f692834 Croatia
5d2ea5a0-3812-4d07-bc83-e7557e2c20cd Czech Republic
340d33d7-db60-4da5-8988-3d97adf34e40 Poland
6f662a23-c2f2-45aa-8b67-7622964ab8e6 Netherlands
c6796a85-e78d-406b-86fd-9d50ed361761 Netherlands
642eed60-ab43-438e-b29b-d2b83a1d1d0a Estonia
710d4b07-1223-4202-8a2a-8f2c8a75f77e Greece
27624ad5-a53c-4371-b226-08015a416947 Portugal
36b5dfe7-336d-4134-952e-28633cf67e81 Bulgaria
37bea7dc-eb4c-4a6d-a626-31b8e1a6ac35 Sweden
8e83dd65-51f4-470f-a07f-c2e48c91cd0c Poland
c5e5f6cf-d260-44c6-aac5-44b3514c85b0 France
247f3a3c-b0a8-42bf-aae0-452961210a71 Sweden
635ad7c9-532f-4f1d-a1a1-5137b6daac93 Germany
1ecf956f-f5a6-4ebb-b28c-be0db3d867c8 Germany
f525384a-8929-44a6-aa0d-3ea572ba0573 France
360273d7-50aa-43b3-8eef-efbe04b1f63c Netherlands
827c34ff-479a-4864-9411-9b7485068d3b Spain
529713d3-e7e2-46e2-ad21-1ee6884c5827 Netherlands
c9218e91-3702-48c7-bafc-2a74747ba1b2 Germany
0d2150b0-2b95-48d1-ab50-aaa310de7cb0 Poland
cee9d778-423b-4301-9f27-16e26d8be184 Norway
6b8f38c8-1ec2-4c2b-beeb-31ed145d161d Finland
dcaf512d-d6f7-4e34-8d7c-982d94a7f49c Netherlands
97a89143-ee64-45d0-a21b-cfae8450263a Germany
2f5e5e2f-ab8d-4466-a2bd-3cb87ff7223e Denmark
2a4f90b7-7165-43c0-87f0-06e205cbb250 Germany
556152b5-5ed1-4bb6-90d2-a8846f692834 Croatia
5d2ea5a0-3812-4d07-bc83-e7557e2c20cd Czech Republic

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3125AFF000XXX
E-Number (Finland):
3640496
E-Number (Norway):
4309609
EAN:
8015644007157
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.137 kg
Package Level 1 EAN:
8015644007157

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 10.7 W
Rated Current (In):
125 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1250 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
87.5...125 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA072942R1 ABB
ABB 1SDA072942R1 ABB
Sale price€0,00
Sold Out

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
ZBSREHAB000A000000XX
EAN:
8015644767921
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
407 mm
Product Net Height:
425 mm
Product Net Depth / Length:
383 mm
Product Net Weight:
55 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
60 kg
Package Level 1 EAN:
8015644767921

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu]):
100 %
Number of Poles:
4P
Power Loss:
176 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
Rated Uninterrupted Current (Iu):
1250 A
Rated Voltage (Ur):
690 V
Release:
Ekip Dip LSI
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
2CSM232275N0001 ABB - WLC101X
ABB 2CSM232275N0001 ABB - WLC101X
Sale price€0,00
Sold Out

Installation

Technical

Dimensions

Product Net Width:
0.07 mm
Product Net Height:
0.28 mm
Product Net Depth / Length:
0.28 mm
Product Net Weight:
304 g

Material Compliance

REACH Information:
No data - If REACH inform is not yet available for a certain product
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC002971 - System device clinic-installation
ETIM 10:
EC002971 - System device clinic-installation
1SDA067558R1 ABB - XT2S 160 TMA 100-1000 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2SE3100BFF000XXX
E-Number (Finland):
3638186
E-Number (Norway):
4379278
EAN:
8015644014544
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
90 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
130 mm
Package Level 1 Height:
208 mm
Package Level 1 Depth / Length:
145 mm
Package Level 1 Gross Weight:
1.652 kg
Package Level 1 EAN:
8015644014544

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 8.08 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
500…1000 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMA
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

Recently viewed