Filters

Measurement Sensors

719 products

Showing 313 - 336 of 719 products

Showing 313 - 336 of 719 products
View
Keyence New Stock Image
Keyence LJ-G030 Keyence
Sale price €2.178,95
Only 7 units left

Specifications

Model

LJ-G030

Mounting

Diffuse reflective

Reference distance

30 mm 1.18"

Measuring range

Z-axis (Height)

±10 mm ±0.39"

X-axis (Width)

Near

20 mm 0.79"

Reference distance

22 mm 0.87"

Far

25 mm 0.98"

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 2 laser product (JIS C6802)

Output

0.95 mW

Laser Class

Class II Laser Product (FDA (CDRH) 21CFR PART1040.10), Class 2 Laser Product (IEC 60825-1)

Spot shape (at reference distance)

Approx 40 µm x 25 mm
0.001575" x 0.98"

Repeatability

Z-axis (Height)

1 µm 0.000040"*1

X-axis (Width)

5 µm 0.000197"*2

Linearity Z-axis (Height)

±0.1% of F.S.*3

Sampling cycle (trigger interval)

3.8 ms*4

Temperature characteristics

0.02% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.*5

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 290 g

*1 The value obtained after 64 times averaging at the reference distance.The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*2 The value obtained after 64 times averaging at the reference distance.The target is ø10 mm ø0.39" pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
*3 The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*4 With initial setting, minimum measuring range, and single smoothing processing
*5 The illumination on the receiver of the sensor head when targeting an illuminated white paper.

keyence Stock Image
Keyence LJ-S160 Keyence
Sale price€0,00
Sold Out

Specifications

Model

LJ-S160

Reference distance

211 mm 8.31"*1

Measurement range

Z-axis (height)

±50 mm ±1.97" (F.S.=100 mm 3.94")

X-axis (width)

NEAR side

124 mm 4.88"

Reference distance

143 mm 5.63"

FAR side

160 mm 6.30"

Y-axis

Reference distance

XY data interval

50 μm 0.0020"

Number of XY data points

3200×3200

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

3 μm 0.000118"*4

XY (distance)

5 μm 0.000197"*5

Linearity

Standard area

±0.02% of F.S.*6

High-accuracy area

Imaging time

Min. 0.3 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 5.5 A (at 19.2 V), 4.4 A (at 24 V)*9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 3600 g 7.94 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Keyence Stock Image
Keyence LJ-G015K Keyence
Sale price €11.575,95
Only 4 units left

Specifications

Model

LJ-G015K

Mounting

Specular reflective

Reference distance

15 mm 0.59"

Measuring range

Z-axis (Height)

±2.3 mm ±0.09"

X-axis (Width)

Near

6.5 mm 0.26"

Reference distance

7.0 mm 0.28"

Far

7.5 mm 0.30"

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 2 laser product (JIS C6802)

Output

0.95 mW

Laser Class

Class II Laser Product (FDA (CDRH) 21CFR PART1040.10), Class 2 Laser Product (IEC 60825-1)

Spot shape (at reference distance)

Approx 32 µm x 12 mm 0.001260" x 0.47"

Repeatability

Z-axis (Height)

0.2 µm 0.000008"*1

X-axis (Width)

2.5 µm 0.000099"*2

Linearity Z-axis (Height)

±0.1% of F.S.*3

Sampling cycle (trigger interval)

3.8 ms*4

Temperature characteristics

0.02% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.*5

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 260 g

*1 The value obtained after 64 times averaging at the reference distance.The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*2 The value obtained after 64 times averaging at the reference distance.The target is ø10 mm ø0.39" pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
*3 The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*4 With initial setting, minimum measuring range, and single smoothing processing
*5 The illumination on the receiver of the sensor head when targeting an illuminated white paper.

keyence Stock Image
Keyence LJ-S080 Keyence
Sale price€0,00
Sold Out

Specifications

Model

LJ-S080

Reference distance

160 mm 6.30" *1

Measurement range

Z-axis (height)

±23 mm ±0.91" (F.S.=46 mm 1.81")

X-axis (width)

NEAR side

66 mm 2.60"

Reference distance

72 mm 2.83"

FAR side

78 mm 3.07"

Y-axis

Reference distance

160 mm 6.30"

XY data interval

25 μm 0.0010"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

1 μm 0.000039" *4

XY (distance)

3 μm 0.000118" *5

Linearity

Standard area

±0.055% of F.S. *6

High-accuracy area

±0.03% of F.S. *6

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Keyence Stock Image
Keyence LJ-G015 Keyence
Sale price €1.228,95
Only 6 units left

Specifications

Model

LJ-G015

Mounting

Diffuse reflective

Reference distance

15 mm 0.59"

Measuring range

Z-axis (Height)

±2.6 mm ±0.1"

X-axis (Width)

Near

6.5 mm 0.26"

Reference distance

7.0 mm 0.28"

Far

7.5 mm 0.30"

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 2 laser product (JIS C6802)

Output

0.95 mW

Laser Class

Class II Laser Product (FDA (CDRH) 21CFR PART1040.10), Class 2 Laser Product (IEC 60825-1)

Spot shape (at reference distance)

Approx 32 µm x 12 mm 0.001260" x 0.47"

Repeatability

Z-axis (Height)

0.2 µm 0.000008"*1

X-axis (Width)

2.5 µm 0.000099"*2

Linearity Z-axis (Height)

±0.1% of F.S.*3

Sampling cycle (trigger interval)

3.8 ms*4

Temperature characteristics

0.02% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.*5

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 260 g

*1 The value obtained after 64 times averaging at the reference distance.The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*2 The value obtained after 64 times averaging at the reference distance.The target is ø10 mm ø0.39" pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
*3 The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*4 With initial setting, minimum measuring range, and single smoothing processing
*5 The illumination on the receiver of the sensor head when targeting an illuminated white paper.

Keyence Stock Image
Keyence LJ-S040 Keyence
Sale price €33.115,95
Only 1 unit left

Specifications

Model

LJ-S040

Reference distance

70 mm 2.76" *1

Measurement range

Z-axis (height)

±18 mm ±0.71" (F.S.=36 mm 1.42")

X-axis (width)

NEAR side

31 mm 1.22"

Reference distance

35 mm 1.38"

FAR side

39 mm 1.54"

Y-axis

Reference distance

80 mm 3.15"

XY data interval

12.5 μm 0.0005"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.5 μm 0.000020" *4

XY (distance)

1 μm 0.000039" *5

Linearity

Standard area

±0.02% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Keyence New Stock Image
Keyence LJ-G5001P Keyence
Sale price €5.727,95
Only 9 units left

Specifications

Model

LJ-G5001P

Head compatibility

Compatible

Number of connectable sensors

2 units max.

Display

Minimum display unit

0.1 µm *1, 0.001 mm2, 0.01° (Inch mode : 0.01 Mil, 0.00001 inch)

Maximum display range

±99999.9 mm, ±999999 mm2, ±99999.9° (Inch mode : ±9999.99 Mil, ±999.999 inch)

Input terminal block

Laser remote interlock input

Non-voltage input

Trigger input

For sensor head A, voltage input

Timing 1 input

Voltage input

Auto-zero 1 input

Reset input

Output terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Total judgment output

PNP open-collector output

Error output

PNP open-collector output (N.C.)

Process output

PNP open-collector output

Trigger input enable output

For sensor head A, PNP open-collector output

Adjusted error output

Expansion connector

Timing 2 input

Voltage input

Auto-zero 2 input

Trigger input

For sensor head B, voltage input

Program switching input

Voltage input, 4 inputs

Memory card save input

Voltage input

Laser-Off input

For sensor head A/B, voltage input

Judgment/Binary output

3-level judgment output: OUT1 to OUT8, total judgment output
Binary output: OUT1 to OUT8 measured data output (21 bits)
PNP open-collector output*2

Strobe output

PNP open-collector output

Trigger input enable output

For sensor head B, PNP open-collector output

Adjusted error output

Analog RGB monitor output

SVGA (800 x 600 pixels)

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible)

Ethernet interface

100BASE-TX/10BASE-T

Memory card

Compatible with NR-M1G (1 GB). (with FAT32)

Major functions

Sensor heads calculation, Profile adjustment, Filter, Smoothing, Averaging,
Position adjustment, OUT name change, Measurement mode selection
(Height, position, gap, width, center position, section area, intersection, angle, profile comparison, profile tracking),
Scaling, Average, Measurement, Measured value alarm, Tolerance setting, Auto-zero, Storage (data/profile),
Memory card saving, Program memory, Trigger mode change, Mutual interference prevention, Measuring range change,
Calibration, Laser light adjustment, Sampling time setting, Mask, Profile alarm setting, Inclination adjustment, Height adjustment,
Display language switch, Setting support software connection, Trigger pitch/Measuring time display, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

800 mA or less with 1 sensor head/1 A or less with two sensor heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 1,050 g

*1 When LJ-G015 or LJ-G015K is connected only. When other sensor heads are connected, the minimum display unit is 1 µm.
*2 Time-sharing output of judgment results or binary measured data.
The rating of the NPN open-collector output: 50 mA max. (30 V max.), residual voltage of 1 V max. The rating of the PNP open-collector output: 50 mA max. (30 V max.), residual voltage of 1 V max.
The rating of the non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current (Trigger input terminal: 1 V or less ON voltage, 1.0 mA or less OFF current)
The rating of the voltage input: 26.4 V maximum rating, 10.8 V or less ON voltage, 0.6 mA or less OFF current (Trigger input terminal: 26.4 V maximum rating, 10.8 V or less ON voltage, 1.0 mA or less
OFF current)

keyence Stock Image
Keyence LJ-S025 Keyence
Sale price€0,00
Sold Out

Specifications

Model

LJ-S025

Reference distance

68.5 mm 2.70" *1

Measurement range

Z-axis (height)

±9 mm ±0.35" (F.S.=18 mm 0.71")

X-axis (width)

NEAR side

21 mm 0.83"

Reference distance

23 mm 0.91"

FAR side

25 mm 0.98"

Y-axis

Reference distance

51.2 mm 2.02"

XY data interval

8 μm 0.000315"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.4 μm 0.000016" *4

XY (distance)

0.7 μm 0.000028" *5

Linearity

Standard area

±0.03% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2100 g 4.63 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Keyence New Stock Image
Keyence LJ-G5001 Keyence
Sale price €2.876,95
Only 9 units left

Specifications

Model

LJ-G5001

Head compatibility

Measuring units are interchangeable without factory recalibration.

Number of connectable sensors

Maximum of 2 units

Display

Minimum display unit

0.1 µm *1, 0.001 mm2, 0.01° (Inch mode : 0.01 Mil, 0.00001 inch)

Maximum display range

±99999.9 mm, ±999999 mm2, ±99999.9° (Inch mode : ±9999.99 Mil, ±999.999 inch)

Input terminal block

Laser remote interlock input

Non-voltage or voltage input *2.

Trigger input

For sensor head A, non-voltage input

Timing 1 input

Non-voltage input

Auto-zero 1 input

Reset input

Output terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Total judgment output

NPN open-collector output

Error output

NPN open-collector output (N.C.)

Process output

NPN open-collector output

Trigger input enable output

For sensor head A, NPN open-collector output

Adjusted error output

Expansion connector

Timing 2 input

Non-voltage input

Auto-zero 2 input

Trigger input

For sensor head B, non-voltage input

Program switching input

Non-voltage input, 4 inputs

Memory card save input

Non-voltage input

Laser-Off input

For sensor head A/B, non-voltage input

Judgment/Binary output

3-level judgment output: OUT1 to OUT8, total judgment output
Binary output: OUT1 to OUT8 measured data output (21 bits)
NPN open-collector output*3

Strobe output

NPN open-collector output

Trigger input enable output

For sensor head B, NPN open-collector output

Adjusted error output

Analog RGB monitor output

SVGA (800 × 600 pixels)

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable)

USB interface

Supports USB 2.0 Hi-Speed (compatible with USB 1.1 Full Speed)

Ethernet interface

100BASE-TX/10BASE-T*4

Memory card

Compatible with NR-M1G (1 GB). (with FAT32)

Major functions

Sensor heads calculation, Profile adjustment, Filter, Smoothing, Averaging,
Position adjustment, OUT name change, Measurement mode selection
(Height, position, gap, width, center position, section area, intersection, angle, profile comparison, profile tracking),
Scaling, Average, Measurement, Measured value alarm, Tolerance setting, Auto-zero, Storage (data/profile),
Memory card saving, Program memory, Trigger mode change, Mutual interference prevention, Measuring range change,
Calibration, Laser light adjustment, Sampling time setting, Mask, Profile alarm setting, Inclination adjustment, Height adjustment,
Display language switch, Setting support software connection, Trigger pitch/Measuring time display, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

800 mA or less with 1 sensor head/1 A or less with two sensor heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 1,050 g

*1 When LJ-G015 or LJ-G015K is connected only. When other sensor heads are connected, the minimum display unit is 1 µm.
*2 (NPN model) The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current. (PNP model) The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFFcurrent.
*3 Time-sharing output of judgment results or binary measured data.
The rating of the NPN open-collector output: 50 mA max. (30 V max.), residual voltage of 1 V max. The rating of the PNP open-collector output: 50 mA max. (30 V max.), residual voltage of 1 V max.
The rating of the non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current (Trigger input terminal: 1 V or less ON voltage, 1.0 mA or less OFF current)
The rating of the voltage input: 26.4 V maximum rating, 10.8 V or less ON voltage, 0.6 mA or less OFF current (Trigger input terminal: 26.4 V maximum rating, 10.8 V or less ON voltage, 1.0 mA or less
OFF current)
*4 This is dedicated for connection with IV-series sensor.

keyence Stock Image
Keyence LJ-S015 Keyence
Sale price€0,00
Sold Out

Specifications

Model

LJ-S015

Reference distance

56.5 mm 2.22" *1

Measurement range

Z-axis (height)

±4 mm ±0.16" (F.S.=8 mm 0.31")

X-axis (width)

NEAR side

14 mm 0.55"

Reference distance

15 mm 0.59"

FAR side

16 mm 0.63"

Y-axis

Reference distance

25 mm 0.98"

XY data interval

5 μm 0.000197"

Number of XY data points

3200 × 5000

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.3 μm 0.000012" *4

XY (distance)

0.5 μm 0.000020" *5

Linearity

Standard area

±0.035% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2300 g 5.07 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

keyence Stock Image
Keyence LJ-S8002 Keyence
Sale price€0,00
Sold Out

Specifications

Model

LJ-S8002

Head input

Up to two LJ-S8000 Series head units
* When using two units, heads A and B must be the same model.

Number of registered inspection settings

Up to 1000 settings (depending on SD card capacity and setting contents) for each of SD card 1 and SD card 2; External switching possible

Master profile / number of reference images

Up to 400 per setting (depending on SD card capacity)

Memory card

• SD card slot × 2
• Supports OP-87133 (512 MB), CA-SD1G (1 GB), CA-SD4G (4 GB; Equipped as standard for SD1 slot), and CA-SD16G (16 GB)

Number of tools

Up to 100 per setting

Interface

Control input

20 points (Input terminal block: 5 points, Parallel I/O: 15 points)

Control output

• 28 points (Output terminal block: 6 points, Parallel I/O: 22 points)
• Photo MOSFET*1

RS-232C

• Numerical value output and control I/O (When in use, PLC Link using the RS-232C port cannot be used)
• Supports baud rates of up to 230400 bps

PLC link

• Numerical value output and control I/O using Ethernet or RS-232C ports
(Cannot be used with EtherNet/IP™; When using an RS-232C port, cannot be used with RS-232C no-procedure communication)

Ethernet

• Numerical value output and control I/O
• In addition to the functions above, uploading/downloading inspection settings, performing various simulations, and sending/receiving images and other data, and using remote desktop connections are possible via KEYENCE PC application software.
• Supports FTP client, FTP server, VNC server (for non-PC clients, only monitor screen display is supported), and BOOTP functions supported
• 1000BASE-T/100BASE-TX/10BASE-T
• Supports jumbo frames

USB

• In addition to numerical value output, uploading/downloading inspection settings, performing various simulations, and sending/receiving images and other data, and using remote desktop connections are possible via KEYENCE PC application software.
• USB 2.0 only

EtherNet/IPTM

• Numerical value I/O and control I/O using the Ethernet port or optional EtherNet/IP™ unit CB-NEP20E
(Cannot be used with PLC Link, PROFINET, or EtherCAT®)
• Supports cyclic communication (max. 1436 bytes) and message communication
• Maximum number of connections: 32 (Ethernet port) / 1: Exclusive Owner, 4: Input Only (CB-NEP20E)
• Complies with Version CT19.1 (Ethernet port) / CT19.1 (CB-NEP20E) conformance tests

PROFINET

• Can input/output numerical values and perform control I/O using the Ethernet port or the optional PROFINET unit CB-NPN20EA (Cannot be used with PLC Link, EtherNet/IP™, and EtherCAT®)
• Supports cyclic communication (max. 1408 bytes) (Ethernet port) / 1252 bytes (CB-NPN20EA)
• Supports acyclic communication (recorded data)
• Complies with Conformance Class A (Ethernet port) / C (CB-NPN20EA)

EtherCAT®

• Numerical value output and control I/O using optional EtherCAT® unit CB-NEC20E (Cannot be used with PLC Link, EtherNet/IP™, or PROFINET)
• Supports cyclic communication (process data object communication) (Input: Max. 536 bytes / Output: Max. 532 bytes)
• Supports acyclic communication (mailbox communication)
• Supports CoE
• Explicit device identification
• Complies with Version 2.5.0 conformance test

Mouse

Various menus can be controlled using the dedicated mouse (included with the controller)

SNTP

Automatic correction of controller date and time when connected to an SNTP server

USB HDD

Images and other data can be output by connecting an HDD (2 TB max.) to the dedicated USB port
(USB 3.0-compliant, bus-powered, rated output: 900 mA)

Monitor output

Analog RGB output, XGA 1024 × 768 (24-bit color, 60 Hz)

Cooling fan

Available

Language

Switchable between English, Japanese, and Chinese (Simplified)

Ratings

Power voltage

24 VDC ±10%

Maximum current consumption

Max. 2.5 A (Typ. 28 W)

Environmental resistance

Ambient temperature

0 to 45°C 32.0°F to 113.0°F (DIN rail mounting) / 0 to 40°C 32.0°F to 104.0°F (Base surface mounting)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 2200 g 4.85 lb

*1 Positive common connection for NPN input devices and negative common connection for PNP input devices supported.

Keyence Stock Image
Keyence CA-EC80LJ Keyence
Sale price €1.158,95
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CA-E110LJ Keyence
Sale price €2.249,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CA-E100LJ Keyence
Sale price €7.157,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87055 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87504 Keyence
Sale price €326,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence LJ-VM100 Keyence
Sale price €898,95
Only 7 units left

Specifications

Model

LJ-VM100

Monitor output

Analog RGB XGA (1024 × 768)
Touch panel monitor (CA-MP120T), specialized connector included

Rating

Power voltage

Supplied from the controller

Power consumption

2.5 W or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

20 to 85 % RH (No condensation)

Weight

Approx. 400 g

Keyence Stock Image
Keyence CA-MP120T Keyence
Sale price €2.607,95
Only 9 units left

Specifications

Model

CA-MP120T*1*2

Display panel

No. of dots

1,024 (W) x 768 (H) dots or 800 (W) x 600 (H) dots

Active display area

245 (W) x 184 (H) mm 9.65 " (W) x 7.24 " (H)

Structure

Panel-mount type Front face is IP65 rated when panel mounted

Backlight

Duration

Approx 100,000 hours (When installed in an upright position under 25 °C 77 °F)

Input/Output

Input signal

Analog RGB signal (0.7 Vp-p, 75 Ω) , Horizontal/vertical synchronization signal

Input signal mode

1,024 (W) x 768 (H) , Vertical frequency: 60 Hz or
800 (W) x 600 (H) , Vertical frequency: 60 Hz

Connector

High-density D-sub 15-pin female (3-way, inch screw)

Touch panel connector

D-sub 9-pin male (2-way, inch screw) *3

Console connector

Connector for RJ45 use

Rating

Power voltage

24 VDC ±10 %

Current consumption

1 A max.

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

85% RH or less

Weight

Approx. 2.3 kg

*1 Options for CA-MP120(T) Monitor mounting stand: OP-87262, Pole-mounting bracket: OP-42279
*2 Options for CA-MP120T
For XG-X/XG-7000/CV-X400: OP-87264 (Touch panel modular RS-232C cable 3 m 9.84 ') , OP-87265 (Touch panel modular RS-232C cable 10 m 32.8 ')
For XG-8000: OP-87258 (Touch panel RS-232C cable 3 m 9.84 ') , OP-87259 (Touch panel RS-232C cable 10 m 32.8 ')
Screen protector: OP-87263
Handheld console junction cable: OP-87260 (Handheld console junction cable 3 m 9.84 ') , OP-87261 (Handheld console junction cable 10 m 32.8 ')
*3 Use a junction cable if the handheld console is inserted into the slot at the console connector.
Console connector does not support XG-X Series USB consoles.

Keyence Stock Image
Keyence CA-MP120 Keyence
Sale price €564,95
Only 8 units left

Specifications

Model

CA-MP120*1

Display panel

No. of dots

1,024 (W) x 768 (H) dots or 800 (W) x 600 (H) dots

Active display area

245 (W) x 184 (H) mm 9.65 " (W) x 7.24 " (H)

Structure

Panel-mount type Front face is IP65 rated when panel mounted

Backlight

Duration

Approx 100,000 hours (When installed in an upright position under 25 °C 77 °F)

Input/Output

Input signal

Analog RGB signal (0.7 Vp-p, 75 Ω) , Horizontal/vertical synchronization signal

Input signal mode

1,024 (W) x 768 (H) , Vertical frequency: 60 Hz or
800 (W) x 600 (H) , Vertical frequency: 60 Hz

Connector

High-density D-sub 15-pin female (3-way, inch screw)

Touch panel connector

-

Console connector

Rating

Power voltage

24 VDC ±10 %

Current consumption

1 A max.

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

85% RH or less

Weight

Approx. 2.3 kg

*1 Options for CA-MP120(T) Monitor mounting stand: OP-87262, Pole-mounting bracket: OP-42279

Keyence New Stock Image
Keyence LJ-V7300 Keyence
Sale price €4.479,95
In stock, 11 units

Specifications

Model

LJ-V7300

Mounting conditions

Diffuse reflection

Reference distance

300 mm 11.81"

Measurement range

Z-axis (height)

±145 mm 5.71"
(F.S.=290 mm 11.42")

X-axis (width)

NEAR side

110 mm 4.33"

Reference distance

180 mm 7.09"

Far side

240 mm 9.45"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 240 mm × 610 µm
9.45" × 0.024016"

Repeatability

Z-axis (height)

5 µm 0.000197"*2*3

X-axis (width)

60 µm 0.002363"*2*4

Linearity

Z-axis (height)

±0.05 to ±0.15% of F.S.*5*6

Profile data interval

X-axis (width)

300 µm 0.012"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*7

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*8

Ambient light

Incandescent lamp: 10,000 lux max.*9

Ambient temperature

0 to +45 °C 32 to 113 °F*10

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 1,000 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 The linearity will differ depending on the measurement area.
*7 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*8 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*9 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*10 The sensor head must be mounted on a metal plate for use.

Keyence New Stock Image
Keyence LJ-V7200 Keyence
Sale price €3.272,95
In stock, 12 units

Specifications

Model

LJ-V7200

Mounting conditions

Diffuse reflection

Reference distance

200 mm 7.87"

Measurement range

Z-axis (height)

±48 mm 1.89"
(F.S.=96 mm 3.78")

X-axis (width)

NEAR side

51 mm 2.01"

Reference distance

62 mm 2.44"

Far side

73 mm 2.87"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 90 mm × 85 µm
3.54" × 0.003543

Repeatability

Z-axis (height)

1 µm 0.000040"*2*3

X-axis (width)

20 µm 0.000788"*2*4

Linearity

Z-axis (height)

±0.1% of F.S.*5

Profile data interval

X-axis (width)

100 µm 0.004"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*6

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*7

Ambient light

Incandescent lamp: 10,000 lux max.*8

Ambient temperature

0 to +45 °C 32 to 113 °F*9

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 550 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*7 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*8 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*9 The sensor head must be mounted on a metal plate for use.

Keyence New Stock Image
Keyence LJ-V7080 Keyence
Sale price €651,95
Only 8 units left

Specifications

Model

LJ-V7080

Mounting conditions

Diffuse reflection

Reference distance

80 mm 3.15"

Measurement range

Z-axis (height)

±23 mm 0.91"
(F.S.=46 mm 1.81")

X-axis (width)

NEAR side

25 mm 0.98"

Reference distance

32 mm 1.26"

Far side

39 mm 1.54"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 48 mm × 48 µm
1.89" × 0.001890"

Repeatability

Z-axis (height)

0.5 µm 0.000020"*2*3

X-axis (width)

10 µm 0.000394"*2*4

Linearity

Z-axis (height)

±0.1% of F.S.*5

Profile data interval

X-axis (width)

50 µm 0.002"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*6

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*7

Ambient light

Incandescent lamp: 10,000 lux max.*8

Ambient temperature

0 to +45 °C 32 to 113 °F*9

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 400 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*7 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*8 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*9 The sensor head must be mounted on a metal plate for use.

Keyence Stock Image
Keyence LJ-V7060K Keyence
Sale price €3.120,95
Only 5 units left

Specifications

Model

LJ-V7060K

Mounting conditions

Specular reflection

Reference distance

54.6 mm 2.15"

Measurement range

Z-axis (height)

±7.6 mm 0.30"
(F.S.=15.2 mm 0.60")

X-axis (width)

NEAR side

8 mm 0.31"

Reference distance

14 mm 0.55"

Far side

8 mm 0.31"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 21 mm × 45 µm
0.83" × 0.001772"

Repeatability

Z-axis (height)

0.4 µm 0.000016"*2*3

X-axis (width)

5 µm 0.000197"*2*4

Linearity

Z-axis (height)

±0.1% of F.S.*5

Profile data interval

X-axis (width)

20 µm 0.0008"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*6

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*7

Ambient light

Incandescent lamp: 10,000 lux max.*8

Ambient temperature

0 to +45 °C 32 to 113 °F*9

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 450 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*7 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*8 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*9 The sensor head must be mounted on a metal plate for use.

keyence Stock Image
Keyence LJ-V7020K Keyence
Sale price €2.311,95
Only 4 units left

Specifications

Model

LJ-V7020K*1

Mounting conditions

Specular reflection

Reference distance

24.2 mm 0.95"

Measurement range

Z-axis (height)

±2.3 mm 0.09"
(F.S.=4.6 mm 0.18")

X-axis (width)

NEAR side

6.5 mm 0.26"

Reference distance

7 mm 0.28"

Far side

7.5 mm 0.30"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2M Laser Product*2
(IEC60825-1, FDA(CDRH) Part 1040.10*3)

Output

10 mW

Spot size (reference distance)

Approx. 14 mm × 35 µm
0.55" × 0.001378"

Repeatability

Z-axis (height)

0.2 µm 0.000008"*4*5

X-axis (width)

2.5 µm 0.000099"*4*6

Linearity

Z-axis (height)

±0.1% of F.S.*7

Profile data interval

X-axis (width)

10 µm 0.0004"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*8

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*9

Ambient light

Incandescent lamp: 10,000 lux max.*10

Ambient temperature

0 to +45 °C 32 to 113 °F*11

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 410 g

*1 The double polarization function cannot be used.
*2 Do not look into the beam directly using any optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars).
Viewing the laser output with an optical instrument may pose an eye hazard.
*3 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*4 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*5 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*6 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*7 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*8 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*9 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*10 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*11 The sensor head must be mounted on a metal plate for use.

Recently viewed