
Specifications
Model |
GS-P12C10 |
|||
Type |
Standard/High performance type (12-pin) |
|||
Length |
10 m 32.81' |
|||
Weight |
Approx. 480 g |
|||

Specifications
Model |
SJ-M071G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode | ||||

Specifications
Model |
NR-XHA08T |
|||
Input method |
Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system) |
|||
Number of input channels |
8*1 |
|||
Input connector type |
Dedicated 3-pin connector |
|||
Measurement cycle |
Maximum sampling cycle: 100 μs (10 kHz) to 60 s |
|||
A/D converting system |
Delta-sigma method |
|||
A/D resolution |
24 bits |
|||
A/D integration time (noise filter) |
AUTO (Automatic configuration according to sampling cycle), 25 μs (40 kHz), 208 μs (4.8 kHz), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz) |
|||
Input frequency band |
2 kHz (−3 dB or more) |
|||
Input type |
Voltage input: ±60 V, ±20 V, ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV |
|||
Averaging |
Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average) |
|||
Input impedance |
Voltage input ±2 V range or higher |
1 MΩ ±2% |
||
Voltage input ±1 V range or higher |
10 MΩ ±2% |
|||
Current input |
Approx. 100 Ω |
|||
Measurement range |
±60 V |
Measurable range: −60.000 to +60.000 V |
||
±20 V |
Measurable range: −22.000 to +22.000 V |
|||
±10 V |
Measurable range: −11.000 to +11.000 V |
|||
±5 V |
Measurable range: −5.5000 to +5.5000 V |
|||
±2 V |
Measurable range: −2.2000 to +2.2000 V |
|||
±1 V |
Measurable range: −1.1000 to +1.1000 V |
|||
±500 mV |
Measurable range: −550.00 to +550.00 mV |
|||
±200 mV |
Measurable range: −220.00 to +220.00 mV |
|||
±100 mV |
Measurable range: −110.000 to +110.000 mV |
|||
±20 mA |
Measurable range: −22.000 to +22.000 mA |
|||
Maximum input rating |
Voltage input: ±60 V, Current input: ±30 mA |
|||
Maximum allowable input ground voltage |
120 VAC and 170 Vpeak, or 120 VDC (when using NR-XHA08T protective grounding) |
|||
Withstand voltage |
Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute |
|||
Buffer memory |
16M data*3 |
|||
Warm up time |
30 minutes or more |
|||
Residual noise level |
0.005% of F.S. (typ.) when A/D integration time is set to 20 ms (50 Hz) / 16.7 ms (60 Hz) |
|||
Common mode noise reduction ratio |
105 dB or more (up to 60 Hz DC) (typ.)*2 |
|||
Remote connection |
Dedicated environment-resistant remote unit input port × 1 (Remote IN), Output port × 1 (Remote OUT) |
|||
Synchronization accuracy between remote connection units |
±1 μs*5 |
|||
Power supply |
Supplied from NR-X100W master unit |
|||
Power consumption |
5.8 W or less |
|||
Surrounding air temperature |
−40 to +85°C -40°F to +185°F*6 |
|||
Operating ambient humidity |
Max. 100% RH*7 |
|||
Vibration resistance |
100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*8 |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27) |
|||
Enclosure rating |
IP65/IP67 (IEC 60529) |
|||
Material |
Main unit case: Aluminum die-casting (coated), Display: Reinforced glass, Connectors: Brass (chromate processing), Connector protection cap: PBT+PC |
|||
Weight |
Approx. 690 g 24.36 oz |
|||
*1 Max. expansion: 64 ch (with 8 units connected, using NR-X100W) | ||||

Specifications
Model |
FU-95H |
|||
Type |
Liquid-level detection fiber unit |
|||
Mounting transparent tube diameter |
4 to 26 mm0.157" to 1.024"*1 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Environmental resistance |
Ambient temperature |
-40 to +105 °C -40 to 221 °F |
||
Accessories |
Binding band × 2, nonslip rubber × 2, spacer × 2, screw × 2, nut × 2 |
|||
Weight |
Approx. 22 g |
|||
*1 When the FS-V** Series is used. We recommend a pipe thickness of 1 mm. | ||||

Specifications
Model |
SJ-L005F |
|||
Voltage application method |
High frequency AC method |
|||
Applied voltage |
3 kVAC |
|||
Ion balance |
±10 V *1 |
|||
Installation distance |
50 mm 1.97 " or greater |
|||
Maximum air speed |
7 m/s *1 |
|||
Maximum air flow |
0.16 m3/min |
|||
Ozone concentration |
0.05 ppm or less *1 |
|||
Control input |
Static elimination stop input |
Can switch between “non-voltage input” and “voltage input” *2*3 |
||
Control output |
Alarm (N.C.) /Ion level alarm (N.O.) |
Open collector output: 30 V DC or less |
||
Power supply |
Power voltage |
24 V DC ±10 % (including ripple) or 12 V DC |
||
Power consumption |
310 mA or less (for 24 V DC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to +122 °F |
||
Relative humidity |
35 to 65 % RH (assuming no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Weight |
Approx. 100 g (main unit weight) |
|||
*1 Measurement results taken with an installation distance of 100 mm 3.94 " , maximum air flow and no air filter. (Representative values) | ||||

Specifications
Model |
OP-42192 |
|||
Overview |
AP30/40 panel mounting bracket (Compatible with 5mm thick panel) |
|||
Applicable product |
AP-30, AP-40 |
|||
Material |
Polyacetal |
|||
Note |
Incompatible with AP-C. |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
SV2-B010AS |
|||
General specifications |
Applicable servo amplifier |
SV2-010L2 |
||
Rated output |
100 W |
|||
Rated torque |
0.318 N·m *1 |
|||
Instant maximum torque |
1.11 N·m |
|||
Rated current |
0.85 Arms |
|||
Instant maximum current |
3.1 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.413 N·m/Arms |
|||
Rotor moment of inertia |
0.0739 ×10-4kg·m2 |
|||
Rated power rating |
15.3 kW/s |
|||
Rated angle acceleration |
48200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.7 kg |
|||
Electromagnetic brake specifications |
Capacity |
5.5 W |
||
Rated voltage |
24 VDC ±10% |
|||
Rated current (@20°C 68°F) |
0.23 A |
|||
Holding torque |
0.318 N·m |
|||
Release time |
60 ms *2 |
|||
Operating time |
100 ms *2 |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||


Specifications
Model |
CZ-V22P |
|||
Output |
PNP output |
|||
Main unit/expansion unit |
Expansionunit (with outputcable) |
|||
Response time |
8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED) |
|||
Control output |
PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1 |
|||
Protection circuit |
Reverse-polarity protection, overcurrent protection, surge absorber |
|||
External calibration input |
No-voltage input, input time: 20 ms or more |
|||
External shift input | ||||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively) |
|||
Unit expansion |
Up to 3 units (4 units total including the main unit)*2 |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*3 |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing, cover: Polycarbonate |
|||
Weight |
Approx. 100 g |
|||
*1 20 mA max. when several units are connected. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
EH-440 |
|||
Type |
Standard , Non-shielded , Cylindrical and threaded |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
40 x 40 mm1.57" |
|||
Stable detecting range |
0 to 18 mm0.71" |
|||
Maximum detecting distance |
36 mm1.42" |
|||
Hysteresis |
0.1 mm0.004" |
|||
Repeatability |
0.037 mm0.001" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 280 g (including nuts and 3-m 9.8' cable) |
|||

Specifications
Model |
CA-LHS8 |
|||
Type |
High-resolution lens |
|||
Overview |
Specialised lens for the compact camera (ø17 ø0.67"). |
|||

Specifications
Model |
FS-N11P |
|||
Type |
Standard 1 output |
|||
Output |
PNP |
|||
Main unit/expansion unit |
Main unit |
|||
Control output |
1 |
|||
External input |
- |
|||
Light source LED |
Red, 4-element LED |
|||
APC |
ON/OFF switchable (Factory setting: OFF) |
|||
Response time |
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA |
|||
Unit expansion |
Up to 16 units can be connected total (two output type is treated as two units) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current Consumption |
Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*1 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
||
Ambient temperature |
-20 to +55 °C -4 to +131 °F (No freezing)*2 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Both main unit and expansion unit housing material: Polycarbonate |
|||
Weight |
Approx. 75 g |
|||
*1 Increases 100 mW (4.0 mA) for High Speed mode | ||||

Specifications
Model |
CA-DRW20X*1 |
|||
Type |
High-Intensity LumiTraxTM Light |
|||
LED color |
White |
|||
Power consumption |
60.9 W (during normal light emission) |
|||
Weight |
Approx. 610 g |
|||
*1 When connecting two units, including the CA-DRW20X, to the CA-DC50E, DC30E, the maximum light intensity that can be set is limited. For details, contact KEYENCE. | ||||

Specifications
Model |
SV-E10A |
|||
Type |
Encoder cable, Standard |
|||
Length |
10 m 32.8' |
|||
Note |
for 1 k to 5 kW motor |
|||

Specifications
Model |
OP-87664 |
|||
Type |
Adjustable relay bracket |
|||
Applicable product |
PR Series, PZ Series, LR Series |
|||
Material |
Nickel-plated zinc, etc. |
|||
Weight |
Approx. 190 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-88664 |
|||
Type |
Ethernet cable (M12 X-coded 8-pin) NFPA79-compatible |
|||
Length |
2 m 6.6' |
|||
Weight |
Approx. 130 g |
|||

Specifications
Model |
AP-V80W |
|||
Type |
Standard (DIN), NPN |
|||
Display |
2-level display with 4 1/2-digit, 7-segment LED (Character height: Upper level: 8 mm 0.32", red, Lower level: 5.7 mm 0.22", green) Alarm indicator: Red LED |
|||
Operation indicator |
Red LED x 3 (corresponding to control output 1 and 2) |
|||
Display resolution |
AP-10SK/AP-11SK: Standard mode 0.1inchHg, High-resolution mode 0.01inchHg |
|||
Power consumption |
Normal |
12V:1380mW(115mA) or less |
||
Eco mode |
12V:1020mW(85mA) or less |
|||
Hysteresis |
Variable (Standard: 0.5% of FS; high-resolution: 0.1% of F.S.) |
|||
Response time (Chattering prevention function) |
Selectable from 5, 10, 100, 500 and 1000 seconds |
|||
I/O |
Analog output |
4 to 20 mA, Maximum load resistance: 260Ω . |
||
Zero-shift input |
Input time of 20 ms or more. (or analog output selectable) |
|||
Bank input | ||||
Control output |
NPN (PNP) open collector x 2 channels (N.O./N.C. selectable), 40 VDC (30 VDC) max., 100 mA max. with residual voltage of 1 V max. |
|||
Rating |
Power voltage |
12 to 24 VDC Ripple (P-P) 10% or less |
||
Environmental resistance |
Ambient temperature |
-10 to +50°C (14 to 122°F), No condensation |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively |
|||
Material |
Housing and cover: Polycarbonate, Keytop: Elastomer |
|||
Accessories |
AP-V80W (P) / V82W (P): DIN-rail mounting bracket, power cable, unit stickers |
|||
Weight |
Approx. 85 g |
|||
*1 Excluding the current for analog output Including the current for the sensor head | ||||


