Machine Vision Systems

5768 products

Showing 1225 - 1248 of 5768 products

Showing 1225 - 1248 of 5768 products
View
Keyence Stock Image
Keyence KV-RC32BX Keyence
Sale price €981,95
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SV2-B020AK Keyence
Sale price €747,95
Only 1 unit left

Specifications

Model

SV2-B020AK

General specifications

Applicable servo amplifier

SV2-020L2

Rated output

200 W

Rated torque

0.637 N·m *1

Instant maximum torque

2.23 N·m

Rated current

1.6 Arms

Instant maximum current

5.8 Arms

Rated rotation speed

3000min-1

High rotation speed

6000 min-1

Torque constant

0.444 N·m/Arms

Rotor moment of inertia

0.333 ×10-4kg·m2

Rated power rating

15.4 kW/s

Rated angle acceleration

24200 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

22 bits

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20 to 80% RH (no condensation)

Operating atmosphere

Indoors (no corrosive gas, flammable gas, oil mist, or dust)

Altitude

2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: phase A, CE: phase B

Min. insulation resistance

500 VDC, 10 MΩ or more with insulation resistance tester

Isolation voltage tolerance

1500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part15 B, ICES-003. Class A

Allowable load inertia moment

15 ×

Approx. weight

1.4 kg

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

0.637 N·m

Release time

60 ms *2

Operating time

100 ms *2

*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*2 The release time and operation time of the electromagnetic brake vary depending on the discharge circuit.

Keyence Stock Image
Keyence LS-C10A Keyence
Sale price €210,95
In stock, 11 units

Specifications

Model

LS-C10A

Type

Cable between the controller and measuring head

Applicable product

LS-7000 series

Number included

1

Cable end

Straight

Length

10 m 32.8'

Note

Up to two cables are connectable, provided that the total length is a maximum of 40 m 131.2'.

Weight

Approx. 700 g

keyence Stock Image
Keyence FI-T8 Keyence
Sale price€0,00
Sold Out

Specifications

Model

FI-T8

Supported pipe diameter

1/8", 1/4"
(6 A, 8 A)
ø8–14 ø0.31"–0.55"

Supported pipe materials

Metal piping

Supported temperature range

−20 to +180°C –4 to +356°F*1

Display method

Organic EL, status indicator light

Display resolution

0.1°C 32.18°F

Response time

5 s (50% response), 15 s (90% response)*2

Display amplifier averaging time

0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s

Measurement accuracy

±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3
±1.0°C ±1.8°F (pipe temperature 80–180°C 176–356°F) (ambient temperature of 25°C 77°F)*2*3

Hysteresis

Variable

Measurement principle

Pt100 4-wire type

Power I/O connector

M8 4-pin connector

Power supply

Current consumption

20 mA or less (excluding load current)*4

When used standalone

I/O (switchable)

Output (Ch1/Ch2)

Control output: switching NPN/PNP setting
Open collector output: 30 VDC or less, maximum 100 mA/ch or less, residual voltage 2.5 V or less*5

Analog output (Ch2)

4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5

Power voltage

20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges*5

Network compatibility

IO-Link*6*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

–10 to +60°C -14 to +140°F (no freezing)

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Material

Display amplifier

PBT / PAR / POM / SUS303

Sensor head

Head: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin

Display amplifier mounting bracket

SUS304

Weight

Approx. 70 g 2.47 oz

*1 When pipe temperature is 100°C 212°F or more, the display amplifier cannot be mounted on the pipe clamp unit. Install the amplifier so it is insulated from the heat from the pipe.
*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes and fluid, the ambient temperature and other factors.
*3 This is the value for a constant 25°C 77°F environment, taking into account absolute error and repeatability.
*4 During standalone use, 220 mA or less including load.
*5 When connecting to a FD-H Series/FI-1000 model, please follow the specifications of the display unit.
*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com).
IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).

keyence Stock Image
Keyence OP-89119 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-89119

Type

M12 L-shaped bracket

Material

SUS304

Weight

Approx. 35 g 1.24 oz

Keyence Stock Image
Keyence GL-VM44HP Keyence
Sale price €820,95
Only 2 units left

Specifications

Model

GL-VM44HP

Beam axis spacing/Lens diameter

20 mm 0.79": ø5 ø0.197"

Number of beam axes

44

Total length

880 mm 34.65"

Detection height

860 mm 33.86"

Protection height

905 mm 35.63"

Minimum detectable object size

ø25 mm ø0.98" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

5.6

OFF→ON

49.1 *3

All blocked→ON

56.8 *4

With channel A or B

ON→OFF

16.4

OFF→ON

66.9 *3

All blocked→ON

89.7 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

111 *5

Receiver

122 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

56 *5

Receiver

61 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

580 g 20.47 oz

Receiver

590 g 20.82 oz

Total

1170 g 41.30 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence GS-P8C3 Keyence
Sale price€0,00
Sold Out

Specifications

Model

GS-P8C3

Type

Standard (Straight)

Length

3 m 9.8'

Weight

Approx. 160 g 5.64 oz

Keyence New Stock Image
Keyence XM-P1000 Keyence
Sale price €14.095,95
Only 4 units left

Specifications

Model

XM-P1000*1

Type

Probe

Stage marker

No. of markers

7

Marker light source

Near-infrared LED (870 nm)

Applicable stylus

M4 (Commercially available styluses can be used)

Camera

Compact CMOS image sensor

Status LED

Green: Measurement possible
Yellow: Probe camera image capture possible
Red: Measurement impossible
Off: Not selected

Housing material

Marker body

Quartz glass

Probe housing

PBT plastic

Weight

Approx. 370 g (including the cable)

*1 Included with XM-1000/XM-T1000/XM-1200 and XM-T1200 models.

Keyence Stock Image
Keyence CV-X150A Keyence
Sale price €4.566,95
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence EV-130M Keyence
Sale price €871,95
Only 1 unit left

Specifications

Model

EV-130M*1

Type

DC , Shielded

Shape

M30

Detecting distance

10 mm 0.39" ±10%

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target
(iron, t=1 mm 0.04")

30 x 30 mm 1.18" x 1.18"

Hysteresis

10% max. of detecting distance

Response frequency

250 Hz

Operation mode

N.O.

Temperature characteristics

±10% max. of detecting distance at 23°C 73.4°F,
within -25 to +70°C -13 to +158°F

Control output
(switching capacity)

5 to 200 mA

Protection circuit

Reversed polarity, short-circuit, surge voltage

Cable length

2 m 6.6'

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 20 % or less

Current consumption (leakage
current)

Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Residual voltage

Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +80 °C -13 to 176 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Nickel-plated brass

Accessories

Nut × 2, toothed washer × 1, instruction manual

Weight

Approx. 300 g

*1 This product does not comply with EMC directive.

keyence Stock Image
Keyence GL-R1LP Keyence
Sale price €684,95
Only 5 units left

Specifications

Model

GL-R1LP

Light source

Wavelength

635 nm

Laser class

Class 2 laser product (IEC60825-1/JIS C 6802)
Class 2 laser product (FDA (CDRH) Part 1040.10)*1

Control output

1.0 mW

Power supply

AAA battery × 2

Weight

260 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.

keyence Stock Image
Keyence SV2-B040AS Keyence
Sale price€0,00
Sold Out

Specifications

Model

SV2-B040AS

General specifications

Applicable servo amplifier

SV2-040L2

Rated output

400 W

Rated torque

1.27 N·m *1

Instant maximum torque

4.46 N·m

Rated current

2.5 Arms

Instant maximum current

9.3 Arms

Rated rotation speed

3000min-1

High rotation speed

6000 min-1

Torque constant

0.544 N·m/Arms

Rotor moment of inertia

0.556 ×10-4kg·m2

Rated power rating

33.1 kW/s

Rated angle acceleration

26100 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

22 bits

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20 to 80% RH (no condensation)

Operating atmosphere

Indoors (no corrosive gas, flammable gas, oil mist, or dust)

Altitude

2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: phase A, CE: phase B

Min. insulation resistance

500 VDC, 10 MΩ or more with insulation resistance tester

Isolation voltage tolerance

1500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part15 B, ICES-003. Class A

Allowable load inertia moment

10 ×

Approx. weight

1.7 kg

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

1.27 N·m

Release time

60 ms *2

Operating time

100 ms *2

*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*2 The release time and operation time of the electromagnetic brake vary depending on the discharge circuit.

keyence Stock Image
Keyence SZ-VS005 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SZ-VS005

Type

Connection cable

Applicable product

SZ-V Series

Cable end

Connector (connected to the SZ-V) - Connector (connected to the SZ-V)

Length

0.05 m 0.16'

Material

PVC

Weight

Approx. 80 g

keyence Stock Image
Keyence OP-88502 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88502

Appearance

Adjustable Bracket B (Includes Sensor Head Fastening Screw × 2)

Material

SUS316L Other

Weight

Approx. 20 g

Keyence Stock Image
Keyence CA-D10X Keyence
Sale price €710,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence OP-51664 Keyence
Sale price€0,00
Sold Out
Buy the Keyence OP-51664 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence OP-51664 is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence GS-73PCSO(3198) Keyence
Sale price€0,00
Sold Out

Specifications

Model

GS-73PCSO(3198)

Lock type

Power-to-lock type

Type

Advanced function type

Response time

Lock

Lock→Unlock

320 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

2*6

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

Approx. 10 mA × 1

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

Approx. 2.5 mA × 2*7

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*8

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*9

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 380 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 The number of AUX outputs is 1 when the OSSD operation is open/close link mode.
*7 The number of OSSD operation switching inputs is 1 when the OSSD operation is lock link mode.
*8 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*9 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence OP-89011 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence PR-F51N1 Keyence
Sale price €297,95
Only 1 unit left

Specifications

Model

PR-F51N1

Type

Thrubeam

Output

NPN

Shape

Flat

Cable connection

1 m cable

Detection distance

0.6 m

Number of control outputs

2 outputs

Output operation

Output 1

Dark-ON

Output 2

Light-ON

Response time

Output 1

0.5 ms

Output 2

ON→OFF: 2.7 ms, OFF→ON: 0.5 ms

Sensitivity adjustment

None

Spot diameter

-

Light source

4 element, point light source, red LED (650 nm)

Mutual interference prevention function

-

Indicator lamp

Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green)

Control output

30 VDC or lower, 50 mA or lower
Leakage current:
When 3 kΩ load resistance, 0.3 mA or lower. When 1 kΩ load resistance, 0.5 mA or lower. When 0.2 kΩ load resistance, 1.5 mA or lower
Residual voltage:
When 10 mA or lower, 1.0 V or lower. When 10 to 30 mA, 1.5 V or lower. When 30 to 50 mA, 2.0 V or lower.

Protection circuit

Power supply reverse connection protection, output overcurrent protection,
output surge protection, power supply surge protection

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %

Current consumption

Transmitter: 11 mA, Receiver: 16 mA

Environmental resistance

Enclosure rating

IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250)

Insulation resistance

20 MΩ or higher (500 VDC)

Ambient light

Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower

Ambient temperature

-25 to +55 °C -13 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, indicator cover/lens cover: polysulfone,
cord protector: polymethylpentene, filler: polyester-based resin

Accessories

Instruction manual

Weight

Approx. 36 g

keyence Stock Image
Keyence AI-F10B Keyence
Sale price€0,00
Sold Out

Specifications

Model

AI-F10B

Type

Polarized Light Filter Attachment for Built-in amplifier models, Long range

Applicable product

AI-B160

Note

Included in sensor head package

Keyence Stock Image
Keyence CV-X202FP Keyence
Sale price €1.937,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence GL-S32FH Keyence
Sale price €957,95
Only 3 units left

Specifications

Model

GL-S32FH

Type

Flat type

Detection capability

ø25 mm ø0.98"

Total length

659.5 mm 25.96"

No. of beam

32

Detection height

620mm 24.41"

Protection height

666mm 26.22"

Beam axis spacing

20 mm 0.79"

Operating distance

0.1 to 2 m 0.3' to 6.6'

Effective aperture angle

Max. ±3.75° (when the operating distance is 2 m 6.6')

Light source

Infrared LED (870 nm)

Response time(ms)

Wire synchronization, one-line, or optical synchronization system (channel 0)

ON→OFF

7.9 *1

OFF→ON

50.6 *1 *2

All blocked→ON

68.3 *1 *3

Optical synchronization system (channel A or B)

ON→OFF

10.9 *1

OFF→ON

55.1 *1 *2

All blocked→ON

80.2 *1 *3

OSSD operation

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or wire synchronization
(determined by the wiring)

Light interference prevention function

Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output (OSSD output)

Output type

2 transistor outputs
(PNP or NPN output is determined by the cable type.)

Max. load current

Max. 300 mA

Residual voltage (when ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

OFF state voltage

Max. 2.0 V (with a cable length of 5 m 16.4')

Leakage current

Max. 200 µA

Max. load capacitance

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Inputs 1 and 2

Short-circuit current: approx. 1 mA

Power supply

Current consumption(mA)

When the center indicator is ON

Transmitter

45*4

Receiver

70*4

When the center indicator is OFF

Transmitter

29*4

Receiver

53*4

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1: 2015 (Category 4, PLe)
UL508, UL1998
GB/T4584

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Operating relative humidity

15 to 85 % RH (no condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Polyarylate

Weight

Transmitter

290 g

Receiver

295 g

*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”.
In the case of series connection, if the total number of beam axes exceeds 100, the response time must be limited to 30 ms or less.
When the GL-S units are connected in series, the response time is calculated according to the following steps;
1. Sum up the response time of all unit.
2. Subtract the following time from the result of previous step.
(ON → OFF)
One sub unit connected: 2 ms
Two sub units connected: 4.2 ms
(When using Optical synchronization system and Channel A or B)
One sub unit connected: 2.7 ms
Two sub units connected: 5.7 ms
(OFF → ON)
One sub unit connected: 42 ms
Two sub units connected: 84 ms
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-S operates in optical synchronization system and the transmitter and receiver is not synchronized (top and bottom beam axes are both blocked).
In this situation, the response time is longer because the GL-S synchronizes the transmitter and receiver first and then determines the clear or blocked.
*4 The control output (OSSD) current is not included. When inputs are turned ON, the current consumption increases by 1 mA per input.

keyence Stock Image
Keyence OP-88492 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87588 Keyence
Sale price €373,95
Only 3 units left

Specifications

Model

OP-87588

Cable end

M12 L-shaped type - Loose wires

Length

10 m 32.81'

Material

Covering: PUR, Nut: Nickel plating over zinc die-cast