

Specifications
Model |
TH-315 |
|||
Type |
Detecting minute metallic objects |
|||
Minimum detectable object |
0.3 mm dia. |
|||
Detecting area |
15 mm |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 170 g |
|||
*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69". | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



Specifications
Model |
TA-340 |
|||
Sensitivity adjustment |
Sensitivity selector switch and fi ne-adjustment trimmer |
|||
Output |
Control output |
Solid-state |
100 mA (40 V max.)*1 |
|
Relay contact |
SPDT 250 VAC 2 A*2 |
|||
Control output |
1 ms |
|||
10 ms | ||||
OFF-delay time |
65 ms (contact output only) |
|||
Rating |
Power voltage |
100/200 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Accessories |
Plastic screwdriver |
|||
Weight |
Approx. 330 g |
|||
*1 Both the solid-state and contact outputs of the amplifi er are one-shot signals; the signals turn on as the object enters the sensor head. NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. | ||||

Specifications
Model |
SV2-BE20G |
|||
Type |
Encoder cable, Hi-flex robotic cable with battery |
|||
Length |
20 m 65.6' |
|||
Note |
for 50 to 750 W motor |
|||

Specifications
Model |
OP-84350 |
|||
Type |
L-shaped Mounting Bracket |
|||
Applicable product |
LV-S62 |
|||
Material |
SUS304, SUS(Screw) |
|||
Note |
Screw (SUS) attached. Optional. |
|||

Specifications
Model |
SV2-M005AS |
|||
General specifications |
Applicable servo amplifier |
SV2-005L2 |
||
Rated output |
50 W |
|||
Rated torque |
0.159 N·m *1 |
|||
Instant maximum torque |
0.557 N·m |
|||
Rated current |
0.55 Arms |
|||
Instant maximum current |
2.0 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.316 N·m/Arms |
|||
Rotor moment of inertia |
0.0395 ×10-4kg·m2 |
|||
Rated power rating |
6.40 kW/s |
|||
Rated angle acceleration |
40200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.3 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
AP-N10D |
|||
Type |
Dual output type |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44, AP-48 |
|||
Configuration/Display range |
-15 to +110 % of F.S. |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa |
|||
Power consumption |
Normal |
770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less) |
||
Eco mode |
560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less) |
|||
Expansion units |
Max. 16 units (Dual output type is counted as 2 units.)*1 |
|||
Control output(s) |
2*2 |
|||
Display temperature characteristic |
±1 % of F.S. (When the temperature varies from 25 °C 77 °F) |
|||
Response time (Chattering prevention function) |
1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2 |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing)*3 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Material |
Main unit and cover: Polycarbonate |
|||
Weight |
Approx. 20 g |
|||
*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers. | ||||


Specifications
Model |
SJ-L005MT |
|||
Type |
Tube type |
|||
Voltage application method |
High frequency AC method (68 kHz) |
|||
Applied voltage |
2.5 kVAC |
|||
Ion balance |
±10 V*1 |
|||
Static elimination time |
See Data Sheet. |
|||
Air supply pressure |
0.05 to 0.5 MPa |
|||
Air supply temperature |
0 to +50°C 32 to 122°F |
|||
Connection tube |
Outer diameter: ø6 0.24", inner diameter: ø4 0.16" |
|||
Ozone concentration |
0.05 ppm or less*2 |
|||
Control input |
Static elimination stop input |
Switchable between non-voltage input and voltage input |
||
Reset input | ||||
LPC mode input | ||||
Control output |
Alarm (N.C.)/Ion level alarm (N.O.) |
Open-collector output 30 VDC or less |
||
Ratings |
Power voltage |
24 VDC ±10% (including ripple) or |
||
Current consumption |
0.2 A or less (24 VDC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used) |
||
Relative humidity |
35 to 65% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Material |
Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT |
|||
Weight |
Approx. 65 g |
|||
*1 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 50 mm 1.97", and air supply pressure of 0.2 MPa (typical values) | ||||

Specifications
Model |
IV4-G500MA |
|||
Type |
Standard model |
|||
Installed distance |
From 50 mm 1.97" |
|||
Field of view |
Installation distance of 50 mm 1.97": 22 (H) × 16 (V) mm to |
|||
Image receiving element |
Type |
1/2.9 inch monochrome CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Focus adjustment |
Auto *1 |
|||
Exposure time |
12 μs to 9 ms *2 *3 |
|||
Lights |
Illumination |
Infrared LED |
||
Lighting method |
Pulse lighting |
|||
Indicators |
2 indicators (both displaying same content) |
|||
Power supply |
Average power consumption |
2.5 W (without AI imaging illumination unit installed) |
||
Environmental resistance |
Enclosure rating |
IP67 *4 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *5 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions |
|||
Material |
Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *6 |
|||
Weight |
Approx. 75 g 2.65 oz (no AI imaging illumination unit) |
|||
*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program. | ||||


Specifications
Model |
FD-XS8E |
|||
Supported pipe materials |
Metal pipes, Plastic pipes (soft/hard) *1 |
|||
Supported fluids |
Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1 |
|||
Supported fluid temperature |
0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature) |
|||
Clamp set model |
Plastic pipe/tube attachment |
FD-XC8R1, FD-XC8R2, FD-XC8R3 |
||
Metal pipe attachment |
FD-XC8M*2 |
|||
Maximum rated flow rate |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : 3000 mL/min |
|||
Zero cut flow rate |
50 mL/min*3 (variable, default) |
|||
Display resolution |
Instantaneous flow rate |
1/10 mL/min (Displayed on controller) |
||
Repeatability |
Response time 50 ms: ±20 % of RD |
|||
Hysteresis |
Variable |
|||
Display method |
Status indicator |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4 |
||
Ambient temperature |
-10 to 60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 % to 85 %RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction |
|||
Shock resistance |
50 G 11 ms 3 times each for X,Y,Z direction |
|||
Material |
Sensor head |
Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM |
||
Clamp set |
For plastic pipe |
Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7 |
||
For metal pipe |
Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7 |
|||
Weight |
Approx. 250 g |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe. | ||||

Specifications
Model |
CA-DWC30 |
|||
Peak wavelength after conversion |
615 nm 0.024 Mil |
|||
Conversion efficiency |
Approx. 80 to 90 %*1 |
|||
Sheet size |
A4 (210 × 297 mm 8.27" × 11.69"), thickness: 0.2 mm 0.01"*2 |
|||
Sheet composition |
(1) Laminate: Polyester film (transparent, sand mat treatment) |
|||
Weight |
Approx. 20 g (including the peelable sheet) |
|||
*1 This is the value only for the special wavelength converting material. | ||||

Specifications
Model |
FD-XA5 |
|||
Type |
Panel type, main unit |
|||
Display method |
Output indicator, 4-digit 7 segment display, OLED, Stability level display |
|||
Display refresh frequency |
Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second |
|||
Response time |
50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms) |
|||
Integration data storage interval |
Written to the memory every 10 seconds |
|||
Memory back up |
EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more) *1 |
|||
Detection mode |
ch.1 |
Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable) |
||
ch.2 |
Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable) |
|||
Input/output |
Output |
NPN/PNP setting switch |
||
Analog output |
4-20 mA/0-20 mA (selectable) load resistance: 500 ohms or lower |
|||
External input |
Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable) |
|||
Network support |
IO-Link*3 |
|||
Unit expansion |
- |
|||
Protection circuit |
Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10 % ripple (P-P) , Class 2 |
||
Power consumption |
195 mA or lower (including the sensor head, excluding the load current) |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C (No freezing) 14 to 122 °F |
||
Relative humidity |
35 % to 85 %RH (No condensation) |
|||
Vibration resistance |
10 - 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction |
|||
Shock resistance |
100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction |
|||
Material |
Main body case/front sheet: PC, Key top: POM, Cable: PVC |
|||
Weight |
Approx. 210 g |
|||
*1 Internal data from full time recording can be read via USB (Ver.2.0) communication. | ||||


Specifications
Model |
PX-H72G*1 |
|||
Type |
M12 Thrubeam Armored |
|||
Light source LED |
Infrared LED |
|||
Detecting distance |
TURBO |
10 m 32.8' |
||
SUPER |
15 m 49.2' |
|||
ULTRA |
30 m 98.4' |
|||
MEGA |
40 m 131.2' |
|||
Detectable object |
ø7.5 mm ø0.30" |
|||
Spot diameter |
― |
|||
Environmental resistance |
Enclosure rating |
IEC: IP68/JEM: IP68g/NEMA: 4X, 6P, 13/DIN: IP69K |
||
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Case material |
Housing :SUS303 (Plastic parts:PMP, POM) Lens :BK7 |
|||
Accessories |
Screw nut (SUS303) x 4, toothed washer (SUS304) x 2 |
|||
Weight |
Approx. 260 g (Including cable) |
|||
*1 The PX-H72 is available with a 30 m 98.4' cable for the transmitter and 10 m 32.8' cable for the receiver. | ||||

Specifications
Model |
KV-XH16ML |
|||
Type |
Positioning/motion unit |
|||
No. of control axes |
16 axes (total including virtual axes) |
|||
Appropriated device |
Relay: 2112 points (132 channels) |
|||
Output format |
MECHATROLINK-III |
|||
Connectable CPU unit |
KV-X Series/KV-8000A |
|||
Max. number of connectable units |
7 |
|||
Refresh |
Automatic refresh, direct refresh, synchronous refresh between units |
|||
Control mode |
Positioning control, Torque control, Speed control, ML-III command, I/O control |
|||
Control period |
62.5 μs or more (With SV2 Series: 125 μs or more) |
|||
Starting time |
125 μs |
|||
Axis control function execution method |
Ladder program, unit program (flow, C language) |
|||
Unit program capacity |
3 MB (Max. number of blocks: 20000) |
|||
Flow |
Block type |
Positioning control block, synchronization control block, speed control block, torque control block, origin return block, current coordinate change block, speed change block, target coordinate change block, continuous positioning start block, “continuous-point number block” continuous–independent/linear interpolation block, continuous–arc interpolation block, continuous positioning complete standby block, calculation block, standby block, program execute block, program stop/restart block, force close program block, unit interrupt block, cam data read/write block, selection branch block, parallel branch block, merge block, GOTO block, start block, end block |
||
flow |
Max. number of flows |
256 |
||
Number of simultaneous activities |
No upper limit |
|||
Flow |
Internal data Memory |
524288 words |
||
Position unit |
mm, inch, deg (angle), PLS (number of pulses) Decimal point position from 0 to 9 digits, unit conversion function available |
|||
Cumulative address |
-2147483648 to +2147483647 specification units |
|||
Positioning control |
Positioning mode |
Absolute value/relative value |
||
Position setting range |
-2147483648 to +2147483647 specification units |
|||
Interpolation |
Linear interpolation, arc interpolation, helical interpolation |
|||
Single operation address |
-2147483648 to +2147483647 specification units |
|||
Acceleration/deceleration curve |
Linear, SIN |
|||
Acceleration/deceleration time |
0 to 65535 ms |
|||
M-code |
1 to 65000, WITH/AFTER mode |
|||
Sensor positioning |
External input-based switching control from speed to position |
|||
Number of points |
100 points/axis (Trajectory control at 100 points or more possible with flows) |
|||
Special function |
Synchronous tracking control, absolute position tracking control |
|||
Synchronization control |
Input |
External reference, instruction coordinates, current coordinates |
||
Input filter |
Interference prevention function |
|||
Clutch |
Select from direct, slide, and follow-up |
|||
Cam |
Resolution: 2048 to 32768 Data points: 4 to 64 (changes according to the resolution) |
|||
Compensation during operation |
Compensation via auxiliary input, phase compensation, and step angle compensation |
|||
Origin return |
Origin return method |
Data set type, dog type (push), |
||
JOG/inching |
JOG (high speed/low speed), inching (specifiable pulses) |
|||
Teaching |
Current coordinate teaching |
|||
Memory data |
Point parameters (each axis), synchronization parameters (each axis), cam data, unit program, servo parameters, setting read/write during RUN (with some restrictions) |
|||
Output display |
LINK, CONNECT, error status |
|||
Self-diagnosis function |
Diagnosis can be made through hardware errors, various parameter errors, error numbers, and error messages |
|||
Parameter setting |
Parameters can be set from KV STUDIO, ladder programs, and unit programs (flow) |
|||
Data backup |
Coordinates: nonvolatile memory backup (unlimited) Parameter settings: flash ROM backup (20000 switches) |
|||
Internal current consumption |
400 mA or less |
|||
Weight |
Approx. 280 g |
|||

Specifications
Model |
MP-FR10 |
|||
Type |
Single model |
|||
Connection bore diameter |
Rc3/8" (10 A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
2.0 to 1000.0 L/min |
|||
Zero cut flow rate |
2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
─ |
||
Filtration degree | ||||
Drainage cup capacity | ||||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 550 g 19.40 oz |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||


Specifications
Model |
OP-87901 |
|||
Type |
Polarised light filter attachment |
|||
Applicable product |
IV-G600MA |
|||
Weight |
Approx. 5 g |
|||

