Machine Vision Systems

5768 products

Showing 5521 - 5544 of 5768 products

Showing 5521 - 5544 of 5768 products
View
keyence Stock Image
Keyence OP-35382 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-35382

Overview

Cable for RS-232C communication. (includes communication cable 9-pin conversion connector).

Applicable product

CV-100, CV-300, CV-500, CV-700

Length

3 m 9.84'

keyence Stock Image
Keyence EV-112MSO(2062) Keyence
Sale price€0,00
Sold Out

Specifications

Model

EV-112MSO (2062)

Type

Shielded

Shape

M12

Detecting distance

2.5 mm 0.10" ±10%

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target
(iron, t=1 mm 0.04")

12 x 12 mm 0.47" x 0.47"

Hysteresis

10% max. of detecting distance

Response frequency

600 Hz

Operation mode

N.O.

Temperature characteristics

±10% max. of detecting distance at 23°C 73.4°F,
within -25 to +70°C -13 to +158°F

Control output
(switching capacity)

5 to 200 mA

Protection circuit

Reversed polarity, short-circuit, surge voltage

Cable length

500 mm19.685"

Rating

Power voltage

12 to 24 VDC

Current consumption (leakage
current)

Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Residual voltage

Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +80 °C -13 to 176 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Case material

Nickel-plated brass

Weight

Approx. 55 g

keyence Stock Image
Keyence CA-LMHE0510 Keyence
Sale price €2.508,95
Only 5 units left

Specifications

Model

CA-LMHE0510 *1

Optical magnification

×0.5 to ×1.0

WD (at reference magnification)

×0.5: 80.0 mm 3.15"
×1.0: 81.8 mm 3.22" *2

Compatible image sensor size

4/3" (ø23 mm ø0.91")

Field of view

20.5 mm × 25.5 mm to 10.2 mm × 12.8 mm 0.81" × 1.00" to 0.40" × 0.50" (With CA-HF2100x connected)

F-stop range (aperture)

5.0 to 32

Resolution

×0.5: 6.7 μm 0.26 Mil
×1.0: 3.4 μm 0.13 Mil *3

Resolving power

Center/periphery: 120 cycles/mm

TV distortion

0.10 %

Depth-of-field

×0.5: 5.12 mm 0.20"
×1.0: 1.28 mm 0.05" *4

Mount

C-mount

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

80% RH or less (no condensation)

Weight

Approx. 1050 g 2.31 lb

*1 Depending on factors such as the installation orientation and the vibrations of the environment, consider reinforcing the installation such as by implementing countermeasures to hold the lens in place.
For information on the locations to hold the lens in place, see the installation examples.
The above values were calculated according to optical design values. Actual values for individual lenses will differ according to precision of assembly.
*2 WD indicates the distance from the tip of the lens to the workpiece. Changing the magnification changes this distance.
*3 The smallest resolvable feature able to be detected under 550 nm wavelength light.
*4 The depth-of-field is a theoretical value calculated with an F-stop of 16 and a circle of least confusion of 40 μm 1.57 Mil. This varies depending on the F-stop.

keyence Stock Image
Keyence XM-P5000 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence RK-10AYC Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence LV-H65 Keyence
Sale price €241,95
Only 9 units left

Specifications

Model

LV-H65

Type

Wide

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

100 mm 3.94" (150 mm5.91")*1

TURBO

10 to 150 mm 0.39" to 5.91" (10 to 250 mm 0.39" to 9.84")*1

SUPER

100 to 200 mm 3.94" to 7.87" (150 to 350 mm 5.91" to 13.78")*1

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Material

Case

Reinforced glass/plastic

Lens cover

Norbornene plastic

Reflective mirror

Polycarbonate, acrylic

Weight

Approx. 45 g

*1 The parentheses indicate the detecting distance when OP-51428 is used.

Keyence Stock Image
Keyence DL-NS1 Keyence
Sale price €817,95
Only 1 unit left

Specifications

Model

DL-NS1

Cable connector

M12 Male

USB connector

USB TypeA

USB Communication

USB2.0 Full Speed

Interface

USB-COM

OS

Windows 11 Home/Pro/Enterprise (32bit/64bit)
Windows 10 Home/Pro/Enterprise (32bit/64bit)
One OS must be installed.

Control input

The number of input

2

Input type

Voltage input

Maximum rating

26.4V

Minmum ON voltage

DC15V

Maximum OFF current

0.2mA

Control output

The number of output

2

Output type

Photo relay output

Control output current

30VDC 50mA max.per output

Maximum leak current

0.1mA max.

Maximum residual voltage

1V max.

Switch input

Input type

No-voltage input

Supplied voltage

Approx. 5V

Supplied current

10mA max.

Power voltage

USB bus power

Power consumption

100mA max.

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit:Polycarbonate(PC)、Cable:PVC

Weight

Approx. 45 g (including the cable)

Keyence Stock Image
Keyence FT-H50 Keyence
Sale price €433,95
Only 7 units left

Specifications

Model

FT-H50

Type

Mid to low temperature, Ultra long-range

Rated temperature range

32 to 932°F (0 to 500°C) *1

Displayable temperature range

-58 to +968°F (-50 to +520°C)

Detecting distance

Unlimited *2

Measuring distance /
View diameter (example)

500/ø18 mm 19.69"/ø0.71"
1500/ø30 mm 59.06"/ø1.18"
3000/ø75 mm 118.11"/ø2.95"

Sight

2-point visible laser beam *3

Detecting element

Thermopile

Detecting wavelength

8 to 14 μm

Repeatability

±5.4°F (±3°C)

Emissivity (ε) correction

0.10 to 1.99 (0.01 step)

Environmental resistance

Ambient temperature

14 to 131°F (-10 to 55°C), No freezing

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions

Shock resistance

500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total

Material

Case: Reinforced glass plastic,
Infrared collector lens: Germanium,
Laser transmitter: Polyarylate,
Lens tube: Aluminum,
Cable: Vinyl chloride,
Mounting bracket: SUS304,
Mounting screw: Stainless steel

Accessory

Mounting bracket

Weight

Approx. 150g

*1 Repeatability is guaranteed within the rated temperature range.
*2 Place at a distance so that object appears 1.5 times larger than the view diameter.
*3 Visible semiconductor laser beam wavelength 655 nm, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part1040.10). The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.

Keyence Stock Image
Keyence CA-DQW15 Keyence
Sale price €1.806,95
Only 1 unit left

Specifications

Model

CA-DQW15

Type

Square Light (Direct)

LED color

White

Diffusion plate

OP-87042*1

Power consumption

19.2 W*2

Input voltage

12 VDC

Weight

Approx. 520 g

*1 These models are for a single bar. Four sets are required for the whole square.
*2 Total value of four bars

keyence Stock Image
Keyence OP-88392 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88392*1

Type

Separate system

Length

15 m 49.21'

Material

PVC

Weight

Approx. 600 g

*1 The unit connection cable for a vertical integrated system is included with the flow meter.

keyence Stock Image
Keyence OP-42339 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88604 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence GL-R24L Keyence
Sale price €1.200,95
Only 5 units left

Specifications

Model

GL-R24L

Detection capability

ø1.77" ø45 mm

Total length

37.80" 960mm

No. of beam

24

Detection height

36.22" 920mm

Protection height

39.57" 1005mm

Beam axis spacing/Lens diameter

40 mm / ø5 1.57" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

7

OFF→ON

49.3*2

All blocked→ON

64.9*3

Optical synchronization system
(Channel A or B)

ON→OFF

9.5

OFF→ON

53*2

All blocked→ON

74.7*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

57

Receiver

76

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1330 g

Receiver

1340 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

Keyence New Stock Image
Keyence CA-H200M Keyence
Sale price €1.175,95
Only 10 units left

Specifications

Model

CA-H200M

Image element

Monochrome CMOS, 7×/16× high-speed reading using square-pixel

Unit cell size

4.5 µm × 4.5 µm 0.18 Mil × 0.18 Mil

Valid pixel count

2 megapixel mode: 1600 (H) × 1200 (V), 1 megapixel mode: 1024 (H) × 960 (V)

Image size

Equivalent to 1/1.8"

Scanning system

Progressive
At 7× transfer speed: 28.9 ms*1, At 16× transfer speed: 11.8 ms*2

Pixel transfer frequency

At 7× transfer speed: 86 MHz (43 MHz × 2)*1, At 16× transfer speed: 198 MHz*2

Transfer system

Digital serial transfer

Electronic shutter

Can be set to 0.05 to 9000 msec by specifying the following numerical inputs:
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000

Lens mount

C-mount

Enclosure rating

IP64*3

Environmental resistance

Ambient temperature

0 to 45°C 32 to 113°F

Relative humidity

85% RH or less

Weight

Approx. 75 g (not including lens)

*1 Transfer speed setting: Standard
*2 Transfer speed setting: Fast
*3 A KEYENCE-specified IP64-rated lens and environment-resistant cable must be used on the product.

keyence Stock Image
Keyence GS-B41 Keyence
Sale price€0,00
Sold Out

Specifications

Model

GS-B41

Type

Locking type

Weight

Approx. 380 g

Keyence New Stock Image
Keyence DL-RS1A Keyence
Sale price €269,95
In stock, 11 units

Specifications

Model

DL-RS1A*1

Synchronization between the transmitter and receiver

Asynchronous

Transmission code

ASCII

Baud rate

2,400/4,800/9,600/19,200/38,400 bps selectable (Factory-setting: 9,600 bps)

Data bit length

8 bits/7 bits selectable (Factory-setting: 8 bits)

Parity check

None/Even/Odd selectable (Factory-setting: None)

Stop bit length

1 bit

Data delimiter

Data reception: automatically recognizes CR or CR+LF
Data transmission: Fixed to CR+LF

Indicator

Communication indicator lamp (green x 2), Alarm indicator lamp (red),
Power indicator lamp (green)

Sensor
connection
specifications

Number of
connectable
sensor units

Up to 15 units (including main unit)

Power voltage

20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

Power consumption

25 mA max.

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Case/Polycarbonate

Weight

Approx. 53 g

Communication method

Full duplex

*1 For connecting with sensor, please refer to the user's Manual

Keyence Stock Image
Keyence MT-200 Keyence
Sale price €2.933,95
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence CV-X102AP Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88836 Keyence
Sale price €313,95
Only 2 units left

Specifications

Model

OP-88836

Length

5 m 16.4'

keyence Stock Image
Keyence OP-87699 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence BT-WUC74GA Keyence
Sale price€0,00
Sold Out

Specifications

Model

BT-WUC74GA

Dedicated AC adapter specifications

Input side

100 to 240 VAC, 50/60 Hz

Output side

16 VDC, Max. 3.75 A

Dimensions

Dedicated AC adapter specifications

102.5 x 42.5 x 28 mm 4.04" x 1.67" x 1.1"
(not including the cable)

Weight

Approx. 250 g

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F (No freezing)

Relative humidity

20 to 85 % RH (No condensation)

Storage temperature

-20 to +60 °C -4 to 140 °F (No freezing)

Storage relative humidity

20 to 85 % RH (No condensation)

Accessory

AC adapter (OP-88149)*1

Dimensions

67.4 x 105.3 x 288.1 mm 2.65" x 4.15" x 11.34"

Weight

Approx. 410 g

*1 A separate AC cable is required.

keyence Stock Image
Keyence OP-42198 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-42198

Type

Long-distance reflector

Applicable product

LV-H67

Material

Reflector: Acrylic, Base: ABS

keyence Stock Image
Keyence OP-88627 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence FD-G125 Keyence
Sale price €4.140,95
Only 2 units left

Specifications

Model

FD-G125

Pipe size

DN (Diameter Nominal)

100 A, 125 A

NPS (Nominal Pipe Size)

4", 5"

Outer diameter of pipe

ø111 to 117 mm 4.37" to 4.61", ø138 to 144 mm 5.43" to 5.67"

Pipe thickness

3.1 to 6.8 mm 0.122" to 0.27"

Supported pipe materials

Iron, steel, stainless steel

Supported fluids

Air, Nitrogen, other gases*1

Fluid temperature

0 to 60ºC 32 to 140 °F

Recommended pressure

0.4 MPa or greater (58 PSI or greater)

Rated velocity of flow range

Up to 15 m/s

Actual flow rate range (typical)

m3/h

Pipe size 100 A: 470.0
Pipe size 125 A: 720.0

L/min

Pipe size 100 A: 7800
Pipe size 125 A: 12000

CFM

Pipe size 100 A: 280.00
Pipe size 125 A: 420.00

Standard flow rate range (typical) [CFM]

20°C 68°F 60 psi 0.41 MPa

Pipe size 100 A: 1326.34
Pipe size 125 A: 1989.51

20°C 68°F 80 psi 0.55 MPa

Pipe size 100 A: 1681.49
Pipe size 125 A: 2522.23

20°C 68°F 100 psi 0.69 MPa

Pipe size 100 A: 2036.63
Pipe size 125 A: 3054.95

20°C 68°F 120 psi 0.83 MPa

Pipe size 100 A: 2391.78
Pipe size 125 A: 3587.67

Display

QVGA 2.2" LCD color monitor

Display update cycle

Approx. 3 Hz

Display resolution

Instantaneous flow rate

0.1 m3/h, 1 L/min, 0.1 CFM

Consumption/leakage amount

0.1 m3, 1 L, 1 CF

Response time

1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)

Measurement accuracy

Between 10 and 100% of F.S.

±2.0% of RD*2*3*4*5

Between 1 and 10% of F.S.

±1.0% of F.S.*2*3*4*5

Zero point error

±0.15% of F.S.*2*6

Static leakage repeatability

±1.0% of RD*4*7

Hysteresis

Variable

Flow units

CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min

I/O wiring connection port

M12 4-pin connector (male)

Detection mode (switchable)

ch.1

Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8

ch.2

Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8

Standard I/O (switchable)

Control output (ch.1/ch.2)

NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less

Analog output (ch.2)

4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less

External input (ch.2)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output

Analog input (for volume conversion)

M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less

Power supplied to pressure sensor

Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)

Communication interface

USB

USB 2.0

Ethernet

Standard

IEEE 802.3u (100BASE-TX)

Transmission rate

100 Mbps

Cable

Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable

Connector

M12 connector (female, D-code)

Network function

Modbus TCP, EtherNet/IP™, IO-Link*9

Recording capacity

Consumption amount/ leakage amount

Approx. 5 years

Events

100

Power supply

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2

Power consumption

350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),
550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*10

Ambient temperature

Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)

Relative humidity

5 to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Display unit

Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating

Detection head

Body: PPS/SUS304, rear surface: rubber

Mounting/damping bracket

SUS304

Weight

Approx. 2.7 kg

*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.
*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.
*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.
*5 The linearity error characteristic due to the pipe is not included in this value.
*6 It is possible to reduce zero point errors by performing an origin adjustment.
*7 This is the value within the range where measurement accuracy is guaranteed.
*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.
• ch.1: Pulse(+) mode
• ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input
*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 The IP65/67 enclosure rating is lost when a USB connection is established.

Recently viewed