Specifications
Model |
FD-G50L |
|||
Pipe size |
DN (Diameter Nominal) |
32 A, 40 A, 50 A |
||
NPS (Nominal Pipe Size) |
1 1/4", 1 1/2", 2" |
|||
Outer diameter of pipe |
ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44" |
|||
Pipe thickness |
1.65 to 3.5 mm 0.06" to 0.138" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 32 A: 54.00 |
||
L/min |
Pipe size 32 A: 900.0 |
|||
CFM |
Pipe size 32 A: 32.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 32 A: 151.58 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 32 A: 192.17 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 32 A: 232.76 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 32 A: 273.35 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.01 m3/h, 0.1 L/min, 0.01 CFM |
||
Consumption/leakage amount |
0.01 m3, 1 L, 0.1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.7 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||


Specifications
Model |
ER-GM08P |
|||
Type |
General-purpose all-metal shielded type Screw type M8 Cable PNP output Mid-Range |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
2 mm 0.08" ±10% *2 |
|||
Response frequency |
120 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
8 × 8 mm 0.31" × 0.31" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less (32 mA or less at 24 V, 47 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303, Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g 2.29 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types. | ||||

Specifications
Model |
FU-85H*1 |
|||
Heat resistant temperature |
150°C 302°F*2*3 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Minimum bend radius |
R20 mm0.787" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *4 |
|||
Environmental resistance |
Ambient temperature |
-40 to +150 °C -40 to 302 °F |
||
Weight |
Approx. 35 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
GL-VM06LP |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
6 |
|||
Total length |
240 mm 9.45" |
|||
Detection height |
200 mm 7.87" |
|||
Protection height |
285 mm 11.22" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.1 |
|
OFF→ON |
45.7 *3 |
|||
All blocked→ON |
51.2 *4 |
|||
With channel A or B |
ON→OFF |
10.0 |
||
OFF→ON |
54.9 *3 |
|||
All blocked→ON |
68.2 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
60 *5 |
||
Receiver |
73 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
48 *5 |
||
Receiver |
56 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
170 g 6.00 oz |
||
Receiver | ||||
Total |
340 g 12.00 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
SH-440*1 |
|||
Type |
Standard Non-shielded Cylindrical & Threaded |
|||
Shape |
ø40×55 Cylindrical + Threaded |
|||
Detectable object |
Ferrous metal (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
40 x 40 mm 1.57"*2 |
|||
Stable detecting range |
0 to 18 mm 0.71" |
|||
Maximum detecting distance |
40 mm 1.57" |
|||
Repeatability |
0.015 mm 0.0006"*2 |
|||
Hysteresis |
0.05 mm 0.0002"*2 |
|||
Temperature characteristics |
0.08%/°C*2 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 280 g |
|||
*1 The EG-547(W) cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822. | ||||


Specifications
Model |
GL-VM40HN |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
40 |
|||
Total length |
800 mm 31.50" |
|||
Detection height |
780 mm 30.71" |
|||
Protection height |
825 mm 32.48" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
5.5 |
|
OFF→ON |
49.7 *3 |
|||
All blocked→ON |
57.2 *4 |
|||
With channel A or B |
ON→OFF |
15.7 |
||
OFF→ON |
63.9 *3 |
|||
All blocked→ON |
85.6 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
105 *5 |
||
Receiver |
116 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
55 *5 |
||
Receiver |
60 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
530 g 18.70 oz |
||
Receiver | ||||
Total |
1060 g 37.41 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
VS-S500MX |
|||
Storage |
Internal storage |
7 GB |
||
microSD card (external) |
Max. 64 GB *1 |
|||
Image sensor |
Frame rate |
81 fps |
||
Lens |
Mount |
Lens-integrated type |
||
Max. optical magnification |
× 2.0 |
|||
Installation distance |
50 mm to 500 mm 1.97" to 19.69" *2 |
|||
Field of view |
27 mm to 417 mm 1.06" to 16.42" |
|||
I/O connection |
Number of inputs |
1 (insulated) |
||
Number of outputs |
3 (insulated) |
|||
Number of inputs/outputs |
2 (insulated) (input and output switched via settings) |
|||
I/F |
Ethernet |
PoE IEEE 802.3at, M12 X cable × 1 |
||
I/O |
1 In/3 Out/2 In, Out M12 A cable × 1 |
|||
Lighting interface |
Dedicated lighting connection interface × 1 |
|||
External media |
microSD card slot × 1 (UHS-1) |
|||
Functions |
Imaging mode |
1.6 M |
||
Output image pixels |
(5 M mode) |
|||
Exposure time |
0.033 msec to 1000 msec |
|||
Image correction functions |
Gain, Offset, Gamma correction, White balance, Fine HDR |
|||
Indicators |
OLED display, Status LED, Ethernet LED (LINK/ACT), SD card access indicator |
|||
Buttons |
Operation buttons × 3 |
|||
Installation support functions |
Pointer (Class 1 laser product *3), Angle monitor |
|||
Power supply |
Power voltage |
24 V +25%/−20% or PoE (IEEE802.3at Power Class 4) |
||
Current consumption (camera only) |
0.97 A, 18.7 W (for 19.2 V)/0.78 A, 18.7 W (for 24 V) |
|||
Current consumption (including lighting) |
4.7 A, 89.7 W (for 19.2 V)/3.8 A, 89.7 W (for 24 V) |
|||
Current consumption (With CA-DEx10X connected) |
11.3 A, 216.7 W (for 19.2 V)/9.1 A, 216.7 W (for 24 V) *4 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Relative humidity |
85% RH or below (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.05 G2/Hz; X, Y, and Z directions, 0.5 hours (IEC60068-2-64) |
|||
Shock resistance |
50 G, 3 times in each of the 6 directions (IEC60068-2-27) |
|||
Size (H×W×D) |
122.3 mm × 52.6 mm × 69.2 mm 4.81" × 2.07" × 2.72" |
|||
Case temperature |
0°C to 65°C 32 to 149°F *5 |
|||
Standard certifications |
CE, FCC, NRTL, KC, UKCA |
|||
Material |
Case: Aluminum die-casting, Front cover: Glass *6 |
|||
Weight |
Approx. 570 g 20.12 oz |
|||
*1 Using the configuration software, format the media before use. | ||||

Specifications
Model |
FS-N44N |
|||
Type |
Cable |
|||
Output |
NPN |
|||
Main unit/expansion unit |
Expansion unit |
|||
Response time |
23 µs (S-HSPD*1*2) /50 µs (HSPD*3) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
2 |
|||
Number of external inputs |
1 |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*4 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5 |
||
Power consumption |
During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*7 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 73 g |
|||
*1 Restrictions when S-HSPD is selected: Output 2 of dual output types is fixed to OFF. | ||||


Specifications
Model |
AP-31A |
|||
Type |
Negative pressure, Analog, NPN |
|||
Rated pressure |
0 to -101.3 kPa |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure, air or non-corrosive gases |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/s |
|||
Display resolution |
0.1 kPa (0.001 bar) |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Hysteresis |
Variable (when hysteresis mode is selected), 0.5 % of F.S. in standard mode |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
NPN open collector: 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |
|||
Accessories |
Mounting bracket A, mounting bracket B, hexagon socket head cap plug |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
KV-TF40 |
|||
Type |
Temperature control unit |
|||
Memory elements |
EEPROM rewritable one million times |
|||
Number of temperature input points |
4 ch |
|||
Input |
Thermocoupler/Platinum temperature measuring resistor*1 |
|||
Temperature sensor types |
Thermocoupler: K, J, T, E, R, B, N, S, W5Re/W26Re |
|||
Indicated accuracy |
±0.3% of F.S. ±1 digit (at 25°C 77°F), ±0.7% of F.S. ±1 digit (at 0 to 50°C 32 to 122°F) |
|||
Cold junction correction precision |
±1°C ±1.8°F |
|||
Sampling cycle |
125 ms/ch (500 ms/4 ch) |
|||
Control period |
1 to 100 seconds |
|||
Operation mode |
PID control (with auto-tuning and 3 mode stabilizer function installed), |
|||
Tuning mode |
PID auto-tuning mode |
|||
Control output |
Transistor (sink) |
|||
Alarm output |
Transistor (sink)*2 |
|||
Alarm mode |
Absolute value upper limit, absolute value lower limit, deviation upper limit, deviation lower limit, deviation upper limit unexcited, |
|||
Output |
Rated load |
30 VDC, 100 mA or less |
||
Leakage current at OFF |
100 μA or less |
|||
Residual voltage at ON |
1.5 V or less |
|||
Current sensor (CT) input |
4 ch*4 |
|||
Current measurement precision |
Larger of ±5% of an input value and ±2 A of an input value |
|||
Insulation mode |
Between inputs and outputs: Photocoupler and transformer insulation, Between input channels: Photocoupler and transformer insulation |
|||
Others |
Heater wire breaking alarm, control loop wire breaking alarm, measured value |
|||
Internal current consumption |
210 mA or less |
|||
Weight |
Approx. 270 g |
|||
*1 Can be set for each channel. | ||||

Specifications
Model |
OP-87660 |
|||
Applicable product |
IL Series |
|||
Number included |
1 cable |
|||
Cable end |
M8 L-shaped type - e-con |
|||
Length |
2 m 6.56' |
|||
Note |
If you cut the cable, you will require a connector (OP-84338) for connecting to the display unit (amplifier unit). |
|||
Weight |
Approx. 80 g |
|||

Specifications
Model |
FD-GU1 |
|||
System |
Switching type |
|||
Input supply voltage |
100 to 240 VAC; +10%/−15% (50/60 Hz) |
|||
Output voltage |
24 VDC ±5% |
|||
Overvoltage category |
ll |
|||
Ripple noise |
260 mV (p-p) or lower |
|||
Output capacity |
9.1 W (0.38 A) (Class 2) |
|||
Power consumption |
100 VAC: 0.3 A or lower; 200 VAC: 0.2 A or lower |
|||
Pollution degree |
2 |
|||
Withstand voltage |
3000 VAC, 1 minute (between input and output, between all external terminals and case) |
|||
Momentary interruption |
20 ms or lower |
|||
Wiring specifications |
AC input: power supply M4 terminal block, 2 poles; Analog output: M3 terminal block, 2 poles; DC output: M12 4-pin connector |
|||
Protection circuit |
Protection against power supply surge, protection against output short-circuiting |
|||
Main unit size |
63 2.48" × 240 9.45" × 40 1.57" mm |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Ambient temperature |
-20 to +50ºC -4 to 122°F (no freezing) |
|||
Relative humidity |
5 to 90%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz power spectral density: 0.816 G2/Hz in X, Y, Z axis directions |
|||
Shock resistance |
Shock resistance 50 m/s2; 16 ms pulses, 1000 times each for X, Y, and Z axes |
|||
Material |
PBT |
|||
Weight |
Approx. 400 g |
|||

Specifications
Model |
OP-82177 |
|||
Type |
Binding Band and Rubber Tube Set |
|||
Applicable product |
FU-95W |
|||
Number included |
Binding band (2), nonslip rubber (2) |
|||
Material |
Binding band: Nylon Nonslip rubber: Neoprene |
|||
Note |
Compatible with ø26 to 80mm pipe diameter. |
|||

Specifications
Model |
ER-30N03C |
|||
Type |
Ultra-long distance shielded type Screw type M30 Connector with pigtail (M12 4-pin) NPN output |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
26 mm 1.02" ±10% *2 |
||
With distance switching (Mode 2) |
20 mm 0.79" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
15 Hz *3 *4 |
||
With distance switching (Mode 2) |
30 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
78 × 78 mm 3.07" × 3.07" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 150 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||


Specifications
Model |
SJ-M300 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.46" (SJ-M030G,SJ-M030C) |
|||
Total length |
220 mm 8.66" (SJ-M030G,SJ-M030C) |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 300 g |
|||
*1 Measured under the following conditions: | ||||