Specifications
Model |
FL-P140 |
|||
Probe length |
1,400*1 |
|||
Measurement range (dead zone excluded) |
1,365 (1,320)*2 |
|||
Weight |
Approx. 565 g |
|||
*1 Total length including the projected areas of the sensor refer to External Dimension Diagrams for details. Can be shortened up to 100 mm 3.93". | ||||

Specifications
Model |
FD-ECA1 |
|||
Type |
Cable type |
|||
Number of control outputs |
2 |
|||
Number of analog outputs |
1 |
|||
Number of external inputs | ||||
Power supply cable |
2 m 6.6', strand wire, 6 cores |
|||
Response time (90% response) |
50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms)*1 |
|||
I/O |
Control outputs 1 and 2 |
Instantaneous flow/Accumulated flow/Alarm output/Pulse output |
||
Analog output |
Instantaneous flow |
|||
External input |
Zero flow/Origin adjust./Reset total |
|||
Network compatibility |
IO-Link*2 |
|||
Number of connectible units |
─ |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection, and incorrect head cable wiring |
|||
Power supply |
Power voltage |
24 VDC +20%/-10% (including ripple), Class2/LPS |
||
Power consumption |
1680 mW*3excluding load current |
|||
Environmental resistance |
Ambient temperature |
−10°C to +55°C 14 to 131°F (no freezing)*4 |
||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Main unit: polycarbonate, FG terminal: copper/iron |
|||
Weight |
Approx. 90 g 3.17 oz |
|||
*1 5 ms is added to the analog output response time and the response is set to 63%. | ||||


Specifications
Model |
OP-87199 |
|||
Overview |
This is a conversion unit for extending the FS-N10/LV-N10/PS-N10 Series main unit with conventional amplifiers. |
|||
Applicable product |
FS-N10/LV-N10/PS-N10 Series |
|||
Note |
The existing amplifier cannot be connected to the main unit. |
|||


Specifications
Model |
OP-96659 |
|||
Overview |
Connector cable for PZ2 thrubeam. It is printed as P-1S/P-2S. |
|||
Applicable product |
PZ2 Series thrubeam |
|||
Number included |
One for transmitter, the other for receiver. |
|||
Length |
10 m 32.81' |
|||



Specifications
Model |
ES-32DC |
|||
Type |
DC |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
NPN: 200 mA (40 V) max. |
||
Disconnection alarm output |
NPN: 100 mA (40 V) max. Residual voltage: 1 V max. |
|||
Leakage current (OFF time) |
― |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
10 to 28 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
18 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 48 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-42197 |
|||
Overview |
Reflective tape used with polarized retro-reflective laser sensor (25x25m). |
|||
Applicable product |
LV-H62, LV-S61 |
|||
Material |
Polycarbonate, Acrylic adhesive |
|||
Note |
25X25mm, 0.7mm thick |
|||

Specifications
Model |
CA-DBR8 |
|||
Type |
Bar Light |
|||
LED color |
Red |
|||
Diffusion plate |
OP-87042 |
|||
Polarizing plate |
OP-87043 |
|||
Power consumption |
3.6 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 60 g |
|||


Specifications
Model |
XC-T40B2 |
|||
Rated voltage |
125 VAC/DC |
|||
Rated current |
1 A/pin |
|||
Ambient operating temperature |
−40 to +80°C −40 to +176°F |
|||
Screw torque |
0.8 N·m (max.) |
|||
Applicable wire diameter |
AWG22 to 16 |
|||
Environmental resistance |
Insulation resistance |
500 VDC, 1000 MΩ or greater |
||
Withstand voltage |
500 VAC, 1 minute, 1 mA or less |
|||

Specifications
Model |
LV-20A |
|||
Type |
NPN output |
|||
Main unit/expansion unit |
Expansion unit (0 line) |
|||
Control output |
NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.) |
|||
Response speed |
280 µs to 4.7 ms |
|||
Monitor output |
NPN output |
|||
Number of interference |
FINE : None , TURBO : 2 units , SUPER : 4 units |
|||
Protection circuit |
Reversed polarity protection, over-current protection, surge absorber |
|||
Unit expansion |
Up to 7 additional expansion units can be installed (8 units including the main unit), |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less (For the LV-20A/22A/22AP, the power supply voltage is supplied from the main unit.) |
||
Power consumption |
1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) *1 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit |
Polycarbonate |
||
Case | ||||
Weight |
Approx. 35 g |
|||
*1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected. | ||||

Specifications
Model |
SJ-E036H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
420 mm 16.54"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
680 g 23.99oz |
|||
*1 Measured under the following conditions. | ||||


Specifications
Model |
GL-VM104HN |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
104 |
|||
Total length |
2080 mm 81.89" |
|||
Detection height |
2060 mm 81.10" |
|||
Protection height |
2105 mm 82.87" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
8.2 |
|
OFF→ON |
52.1 *3 |
|||
All blocked→ON |
63.6 *4 |
|||
With channel A or B |
ON→OFF |
26.5 |
||
OFF→ON |
87.4 *3 |
|||
All blocked→ON |
125.3 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
185 *5 |
||
Receiver |
201 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
61 *5 |
||
Receiver |
67 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1350 g 47.65 oz |
||
Receiver |
1370 g 48.36 oz |
|||
Total |
2720 g 96.01 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CV-H035C |
|||
Type |
Camera*1 |
|||
Image element |
1/3-inch color CCD image receiving element, 7 x high-speed reading using square-pixel, 340,000 pixels |
|||
Valid pixel count |
310,000 pixels 640 (H) × 480 (V) *2 |
|||
Pixel transfer frequency |
80 MHz 40 MHz × 2ch |
|||
Scanning system |
Progressive (4.7 ms) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values |
|||
Lens mount |
C mount |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 120 g (not including lens) |
|||
*1 Only the high-speed camera cable can be used. | ||||

Specifications
Model |
OP-88381*1 |
|||
Material |
A5052 (black electrode position coating) |
|||
Weight |
Approx. 800 g (not including camera, illumination, or mounting screws) |
|||
*1 The environmental resistance depends on the specifications of the camera and illumination to be used. | ||||

Specifications
Model |
OP-87548 |
|||
Overview |
Gasket for standard specifications. |
|||
Material |
Inorganic fiber + oil resistant rubber |
|||