keyence Stock Image
Keyence GL-VM32LN Keyence
Sale price€0,00
Sold Out

Specifications

Model

GL-VM32LN

Beam axis spacing/Lens diameter

40 mm 1.57": ø5 ø0.197"

Number of beam axes

32

Total length

1280 mm 50.39"

Detection height

1240 mm 48.82"

Protection height

1325 mm 52.17"

Minimum detectable object size

ø45 mm ø1.77" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

5.1

OFF→ON

48.4 *3

All blocked→ON

55.4 *4

With channel A or B

ON→OFF

14.4

OFF→ON

64.2 *3

All blocked→ON

83.9 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

134 *5

Receiver

148 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

54 *5

Receiver

59 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

840 g 29.65 oz

Receiver

850 g 30.00 oz

Total

1690 g 59.65 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence FD-HK2 Keyence
Sale price€0,00
Sold Out

Specifications

Model

FD-HK2

Weight

Approx. 10 g

Keyence Stock Image
Keyence OP-99012 Keyence
Sale price €139,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-87756 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence CA-DPW2 Keyence
Sale price €982,95
Only 5 units left

Specifications

Model

CA-DPW2

Type

Spot Light

LED color

White

Power consumption

8.4 W (2.0 W)*1

Input voltage

12 VDC

Weight

Approx. 20 g

*1 The power consumption specification indicates the total consumption (CA-DP spot + CA-DP power adapter). The specification in parenthesis is just for the CA-DP spot light.

FS-N12P Keyence
Keyence FS-N12P Keyence
Sale price €150,95
In stock, 12 units

Specifications

Model

FS-N12P

Type

Standard 1 output
Cable

Output

PNP

Main unit/expansion unit

Expansion unit

Control output

1
PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

External input

-

Light source LED

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Response time

50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Unit expansion

Up to 16 units can be connected total (two output type is treated as two units)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*1
Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*1
Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C -4 to +131 °F (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 45 g

*1 Increases 100 mW (4.0 mA) for High Speed mode
*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).
When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.

keyence Stock Image
Keyence OP-87652 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87652

Cable end

M12 L-shaped type - Loose wires

Length

10 m 32.81'

Material

Covering: PVC, Nut: SUS316L

keyence Stock Image
Keyence XG-X2802 Keyence
Sale price €2.250,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence MP-FCAC10 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence AH-114 Keyence
Sale price€0,00
Sold Out

Specifications

Model

AH-114

Type

Sensor head

Amplifier unit

AS-421E

Shape

M14 threaded

Measuring range

0 to 5 mm 0.20"

Analog output voltage

Output voltage

0.8 to 2.2V

Straight line range

0.8 to 2.2mm 0.031" to 0.087"

Impedance

100 Ω

Resolution

0.2% of F.S.

Linearity

±2.0% of F.S.

Response

3.3 kHz (-3 dB)

Temperature
fluctuation

Sensor head

0.06% of F.S./°C*1

Temperature characteristics

Amplifier unit

0.1% of F.S.*1

Rating

Power voltage

110/120/220/240 VAC ±10 %, 50/60 Hz

Power consumption

6VA

Environmentalresistance

Enclosure rating

Sensor head

Operating ambient temperature

-10 to +60°C 14 to 140°F

Amplifier unit

0 to +50°C 32 to 122°F

Environmental resistance

Relative humidity

35 to 85 % RH (No condensation)

Weight

Sensor head

Weight (including cord)

Amplifier unit

*1 When the distance between the sensor head and the target is within 50% of the measurement range.

keyence Stock Image
Keyence XM-WA Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence KV-40DR Keyence
Sale price €652,95
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence GL-VM32HN Keyence
Sale price €822,95
Only 2 units left

Specifications

Model

GL-VM32HN

Beam axis spacing/Lens diameter

20 mm 0.79": ø5 ø0.197"

Number of beam axes

32

Total length

640 mm 25.20"

Detection height

620 mm 24.41"

Protection height

665 mm 26.18"

Minimum detectable object size

ø25 mm ø0.98" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

5.1

OFF→ON

48.4 *3

All blocked→ON

55.4 *4

With channel A or B

ON→OFF

14.4

OFF→ON

64.2 *3

All blocked→ON

83.9 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

93 *5

Receiver

104 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

54 *5

Receiver

59 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

420 g 14.82 oz

Receiver

430 g 15.17 oz

Total

850 g 30.00 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence OP-88813 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence TH-105 Keyence
Sale price €1.260,95
Only 5 units left

Specifications

Model

TH-105

Type

Detecting small metallic objects

Minimum detectable object

2.0 mm
0.08" dia.
steel ball*1

Detecting area

50 mm
1.97" dia.

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 450 g

*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69".

Keyence Stock Image
Keyence GL-R72H Keyence
Sale price €1.307,95
In stock, 13 units

Specifications

Model

GL-R72H

Detection capability

ø0.98" ø25 mm

Total length

56.69" 1440mm

No. of beam

72

Detection height

55.91" 1420mm

Protection height

57.68" 1465mm

Beam axis spacing/Lens diameter

20 mm / ø5 0.79" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

12.2

OFF→ON

57.1*2

All blocked→ON

85.6*3

Optical synchronization system
(Channel A or B)

ON→OFF

17.8

OFF→ON

65.5*2

All blocked→ON

108.1*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

75

Receiver

85

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

2010 g

Receiver

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence OP-88754 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-LAR16 Keyence
Sale price€0,00
Sold Out

Specifications

Model

CA-LAR16

Focal point

16 mm 0.63"

F-stop range (aperture)

F1.8 to F16

Minimum WD

0.1 m 0.3'

Mount

C-mount

Filter size

M34 × P0.5

Compatible image sensor size

2/3"

TV distortion

0.08%

Resolving power

250 cycles/mm at center, 180 cycles/mm on periphery

Ambient temperature/humidity range

0 to +50°C 32 to 122°F, 80% RH or less (No condensation)

Lens coating

WIDE, BAND MULTICOATING

Weight

Approx. 186 g 6.56 oz

Keyence New Stock Image
Keyence CZ-H32 Keyence
Sale price €246,95
Only 6 units left

Specifications

Model

CZ-H32

Type

Adjustable spot

Detecting area

50 to 95 mm 1.97" to 3.74"
(Reco mmended: 70 mm 2.76")

Smallest spot diameter

Small: 3 mm 0.12"dia.
Medium: 4.5 mm 0.18"dia.
Large: 5.5 mm 0.22"dia.
at respective reference distance*1

Light source

Red LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm)

Minimum bend radius of fi ber

25 mm 0.98"

Environmental resistance

Enclosure rating

IP40

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing:Fiberglass reinforced plastic , Lens cover:Polyarylate

Weight

Approx. 40 g

*1 Reference distance: 65 mm 2.56” for Small, 60 mm 2.36” for Medium, and 50 mm 1.97” for Large

Keyence Stock Image
Keyence GL-R88H Keyence
Sale price €1.697,95
Only 8 units left

Specifications

Model

GL-R88H

Detection capability

ø0.98" ø25 mm

Total length

69.29" 1760mm

No. of beam

88

Detection height

68.50" 1740mm

Protection height

70.28" 1785mm

Beam axis spacing/Lens diameter

20 mm / ø5 0.79" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

13.9

OFF→ON

59.7*2

All blocked→ON

92.5*3

Optical synchronization system
(Channel A or B)

ON→OFF

20.6

OFF→ON

69.7*2

All blocked→ON

119.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

79

Receiver

89

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

2450 g

Receiver

2460 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence NQ-P8C03 Keyence
Sale price€0,00
Sold Out

Specifications

Model

NQ-P8C03

Length

0.3 m 1.0'

Material

PVC

Weight

Approx. 100 g 3.52 oz

keyence Stock Image
Keyence BT-AB1 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-CN5L Keyence
Sale price €799,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence GL-VM36HP Keyence
Sale price €689,95
Only 6 units left

Specifications

Model

GL-VM36HP

Beam axis spacing/Lens diameter

20 mm 0.79": ø5 ø0.197"

Number of beam axes

36

Total length

720 mm 28.35"

Detection height

700 mm 27.56"

Protection height

745 mm 29.33"

Minimum detectable object size

ø25 mm ø0.98" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

5.3

OFF→ON

48.0 *3

All blocked→ON

55.2 *4

With channel A or B

ON→OFF

15.0

OFF→ON

60.8 *3

All blocked→ON

81.6 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

99 *5

Receiver

110 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

55 *5

Receiver

59 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

480 g 16.94 oz

Receiver

Total

960 g 33.88 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.