Filters
Siemens PLCs
52107 products
That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 4-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 3-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class H 65kA @ 480 V 4-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class H 65kA @ 480 V 2-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class H 65kA @ 480 V 4-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class H 65kA @ 480 V 3-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class M 35kA @ 480 V 4-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class M 35kA @ 480 V 2-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class M 35kA @ 480 V 4-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 2-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class M 35kA @ 480 V 3-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 max short-circuit curr. rating 100kA @ 480V w/o contactor 3-pole, mot. starter protection TM120M, AM, In=800A without overload protection short circuit protection Ii=6...12 x In busbar connection
circuit breaker 3VA5 UL frame 800 max short-circuit curr. rating 65 kA @ 480 V w/o contactor 3-pole, mot. starter protection TM120M, AM, In=800A without overload protection short circuit protection Ii=6...12 x In busbar connection
molded case switch 3VA5 UL frame 800 max short-circuit curr. rating 65kA @ 480 V 3-pole MCS110, In=800A without overload protection self protection Ii=12 x In busbar connection
molded case switch 3VA5 UL frame 800 max short-circuit curr. rating 100kA @ 480 V 2-pole MCS110, In=800A without overload protection self protection Ii=12 x In busbar connection
molded case switch 3VA5 UL frame 800 max short-circuit curr. rating 100kA @ 480 V 3-pole MCS110, In=800A without overload protection self protection Ii=12 x In busbar connection
molded case switch 3VA5 UL frame 800 max short-circuit curr. rating 65kA @ 480 V 2-pole MCS110, In=800A without overload protection self protection Ii=12 x In busbar connection
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 2-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 4-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 4-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 3-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class H 65kA @ 480 V 2-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class H 65kA @ 480 V 3-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
circuit breaker 3VA5 UL frame 800 breaking capacity class M 35kA @ 480 V 4-pole, line protection TM230, FTAM, In=700A overload protection Ir=700A fixed short circuit protection Ii=5...10 x In
Filters