That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
circuit breaker 3VA6 UL frame 400 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 160%) ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 400 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 400 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 400 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In w/o connection
circuit breaker 3VA6 UL frame 400 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU856, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In neutral protection optional with ext. CT;up to160% ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In neutral protection adjustable(OFF; up to 100%) ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5... 10 x Ir, Ii=10 x In w/o connection
circuit breaker 3VA6 UL frame 400 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5...12 x In w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5...10 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU856, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In neutral protection adjustable(OFF; up to 160%) ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU856, LSI, In=60A overload protection Ir=24A ...60A short circuit protection Isd=1,5..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In neutral protection optional with ext. CT;up to160% ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU860, LSIG, In=60A overload protection Ir=24A ...60A short circuit protection Isd=1,5..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 100%) ground fault protection Ig=0,4... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5... 10 x Ir, Ii=10 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5...10 x In neutral protection adjustable(OFF; 50%; 100%) ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU350, LSI, In=60A overload protection Ir=24A ...60A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5...10 x In ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 250 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5...10 x In w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU320, LI, In=60A overload protection Ir=24A ...60A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 100%) w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU856, LSI, In=60A overload protection Ir=24A ...60A short circuit protection Isd=1,5..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 100%) ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU860, LSIG, In=60A overload protection Ir=24A ...60A short circuit protection Isd=1,5..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault protection Ig=0,4... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU350, LSI, In=60A overload protection Ir=24A ...60A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In neutral protection adjustable(OFF; 100%) w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU330, LIG, In=60A overload protection Ir=24A ...60A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 100%) ground fault protection Ig=0,4... 1 x In, tg=0,1/0,3s w/o connection
Filters