Keyence

FD-R125 Keyence

Specifications

Model

FD-R125

Supported pipe diameter

4" (100 A), ø100 to ø127 3.94" to 5.00"
5" (125 A), ø127 to ø152 5.00" to 5.98"

Supported pipe materials

Metal / resin*1

Supported fluids

Various liquids (i.e. water, oils, chemicals)*1

Supported fluid temperature

- 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface)*2

Maximum rated flow

Rated flow velocity range: 5.0 m/s
Flow rate range (Typical):
4"(100 A): 2500 L/min 660 gal/min 150 m3 /h
5" (125 A): 3700 L/min 990 gal/min 220 m3/h)

Zero cut flow rate

Zero cut: 0.3 m/s (default)*3
Flow rate (Typical): 220 L / min 60 gal / min 12 m3/h

Display method

Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator

Display update cycle

Approx. 3 Hz

Display resolution

1 (L / min)

Response time

0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)

Measurement accuracy

Between 20 and 100% of F.S. : ±2.0% of RD*4*5
Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5

Protection circuit

Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output

Zero point error

±0.5% of F.S.*4*6

Hysteresis

Variable

Flow units

L / min, m3 / h, gal / min

Integrated flow unit display

1 / 10 / 100 / 1000 / 10000 (L)

Pipe temperature measurement accuracy

±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F)
±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F)
(ambient operating temperature of 25°C 77°F)*4

Wiring specifications

Power supply

DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)

I/O

When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7

Analog output (ch.1/ch.2)

Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less*7

External input (ch.2)

Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7

Rating

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)

Current consumption

When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less

Environmental resistance

Enclosure rating

IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)

Ambient temperature

- 20 to + 60°C - 4.0 to 140 °F (no freezing)*2

Relative humidity

5 to 90%RH (no condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis

Shock resistance

100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis

Dimensions

Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78"

Material

Main unit

Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent

Unit rear

Rubber

Upper/lower bracket

SUS304

Weight

Main unit: Approx. 1.0 kg
Upper/lower bracket: Approx.2.3 kg (including sub unit)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable due to the type and status of the pipes.
*2 Perform derating depending on the ambient temperature and liquid temperature when using an AC power supply.
*3 The zero cut flow rate can be changed in the settings.
*4 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by the type and status of the pipes, the type and temperature of the fluid, and the zero cut flow rate.
*5 This is the value when considering linearity + span error + repeatability in a stable environment of 25°C 77°F.
*6 It is possible to enhance the precision of zero point error by performing an origin adjustment.
*7 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in an environment where downloading the file is not accessible via Internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)


Sale price$1,574.69
1-year warranty
FREE WORDWIDE SHIPPING
Est. delivery between and  
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Condition:
$0.00
$1,574.69
$0.00

Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa
Description
Warranty
Shipping and Return

Specifications

Model

FD-R125

Supported pipe diameter

4" (100 A), ø100 to ø127 3.94" to 5.00"
5" (125 A), ø127 to ø152 5.00" to 5.98"

Supported pipe materials

Metal / resin*1

Supported fluids

Various liquids (i.e. water, oils, chemicals)*1

Supported fluid temperature

- 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface)*2

Maximum rated flow

Rated flow velocity range: 5.0 m/s
Flow rate range (Typical):
4"(100 A): 2500 L/min 660 gal/min 150 m3 /h
5" (125 A): 3700 L/min 990 gal/min 220 m3/h)

Zero cut flow rate

Zero cut: 0.3 m/s (default)*3
Flow rate (Typical): 220 L / min 60 gal / min 12 m3/h

Display method

Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator

Display update cycle

Approx. 3 Hz

Display resolution

1 (L / min)

Response time

0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)

Measurement accuracy

Between 20 and 100% of F.S. : ±2.0% of RD*4*5
Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5

Protection circuit

Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output

Zero point error

±0.5% of F.S.*4*6

Hysteresis

Variable

Flow units

L / min, m3 / h, gal / min

Integrated flow unit display

1 / 10 / 100 / 1000 / 10000 (L)

Pipe temperature measurement accuracy

±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F)
±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F)
(ambient operating temperature of 25°C 77°F)*4

Wiring specifications

Power supply

DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)

I/O

When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7

Analog output (ch.1/ch.2)

Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less*7

External input (ch.2)

Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7

Rating

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)

Current consumption

When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less

Environmental resistance

Enclosure rating

IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)

Ambient temperature

- 20 to + 60°C - 4.0 to 140 °F (no freezing)*2

Relative humidity

5 to 90%RH (no condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis

Shock resistance

100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis

Dimensions

Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78"

Material

Main unit

Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent

Unit rear

Rubber

Upper/lower bracket

SUS304

Weight

Main unit: Approx. 1.0 kg
Upper/lower bracket: Approx.2.3 kg (including sub unit)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable due to the type and status of the pipes.
*2 Perform derating depending on the ambient temperature and liquid temperature when using an AC power supply.
*3 The zero cut flow rate can be changed in the settings.
*4 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by the type and status of the pipes, the type and temperature of the fluid, and the zero cut flow rate.
*5 This is the value when considering linearity + span error + repeatability in a stable environment of 25°C 77°F.
*6 It is possible to enhance the precision of zero point error by performing an origin adjustment.
*7 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in an environment where downloading the file is not accessible via Internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Description
Warranty
Shipping and Return

Specifications

Model

FD-R125

Supported pipe diameter

4" (100 A), ø100 to ø127 3.94" to 5.00"
5" (125 A), ø127 to ø152 5.00" to 5.98"

Supported pipe materials

Metal / resin*1

Supported fluids

Various liquids (i.e. water, oils, chemicals)*1

Supported fluid temperature

- 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface)*2

Maximum rated flow

Rated flow velocity range: 5.0 m/s
Flow rate range (Typical):
4"(100 A): 2500 L/min 660 gal/min 150 m3 /h
5" (125 A): 3700 L/min 990 gal/min 220 m3/h)

Zero cut flow rate

Zero cut: 0.3 m/s (default)*3
Flow rate (Typical): 220 L / min 60 gal / min 12 m3/h

Display method

Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator

Display update cycle

Approx. 3 Hz

Display resolution

1 (L / min)

Response time

0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)

Measurement accuracy

Between 20 and 100% of F.S. : ±2.0% of RD*4*5
Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5

Protection circuit

Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output

Zero point error

±0.5% of F.S.*4*6

Hysteresis

Variable

Flow units

L / min, m3 / h, gal / min

Integrated flow unit display

1 / 10 / 100 / 1000 / 10000 (L)

Pipe temperature measurement accuracy

±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F)
±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F)
(ambient operating temperature of 25°C 77°F)*4

Wiring specifications

Power supply

DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)

I/O

When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7

Analog output (ch.1/ch.2)

Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less*7

External input (ch.2)

Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7

Rating

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)

Current consumption

When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less

Environmental resistance

Enclosure rating

IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)

Ambient temperature

- 20 to + 60°C - 4.0 to 140 °F (no freezing)*2

Relative humidity

5 to 90%RH (no condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis

Shock resistance

100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis

Dimensions

Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78"

Material

Main unit

Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent

Unit rear

Rubber

Upper/lower bracket

SUS304

Weight

Main unit: Approx. 1.0 kg
Upper/lower bracket: Approx.2.3 kg (including sub unit)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable due to the type and status of the pipes.
*2 Perform derating depending on the ambient temperature and liquid temperature when using an AC power supply.
*3 The zero cut flow rate can be changed in the settings.
*4 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by the type and status of the pipes, the type and temperature of the fluid, and the zero cut flow rate.
*5 This is the value when considering linearity + span error + repeatability in a stable environment of 25°C 77°F.
*6 It is possible to enhance the precision of zero point error by performing an origin adjustment.
*7 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in an environment where downloading the file is not accessible via Internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator

You may also like

Recently viewed