PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
PR-FB15CP |
|||
Type |
Reflective (Background suppression) |
|||
Output |
PNP |
|||
Shape |
Flat |
|||
Cable connection |
M8 connector (4 pin) |
|||
Detection distance |
1 to 15 mm 0.04" to 0.59" |
|||
Number of control outputs |
2 |
|||
Output operation |
Output 1 |
Light-ON |
||
Output 2 |
Dark-ON |
|||
Response time |
Output 1 |
0.5 ms |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. 2.5 x 4.5 mm (at 15 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 10 g |
|||

Specifications
Model |
GL-RA1120 |
|||
Type |
Front Protection Cover |
|||
Overview |
Plastic cover that is used to protect the detecting surface. |
|||
Applicable product |
GL-R111F,GL-R56H,GL-R28L |
|||
Number included |
1 unit |
|||
Material |
Frame: ABS, Transparent parts: Polycarbonate |
|||
Weight |
Approx. 105 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
WI-C5R |
|||
Type |
Sensor head connecting cable, Hi-flex robotic |
|||
Cable end |
Straight |
|||
Length |
5 m 16.40' |
|||

Specifications
Model |
CA-LH35 |
|||
Focal point |
35 mm 1.38" |
|||
F-stop range (aperture) |
F2.0 to F16 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Mount |
C-mount |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
-0.2 % (-0.05 %)*1 |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 69 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||

Specifications
Model |
OP-88092 |
|||
Type |
Ethernet extension cable (M12) |
|||
Length |
20 m 65.62' |
|||
Weight |
Approx. 1,280 g |
|||


Specifications
Model |
CB-B10E*1 |
|||
Type |
Head extension cable |
|||
Cable min. bending R |
22 mm 0.87" |
|||
Cable length |
10 m 32.8' |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529)*2 |
||
Material |
PVC |
|||
Weight |
Approx. 800 g |
|||
*1 Regarding cable extension between the head and controller: Up to 2 cables can be connected with the CB-BxxE, and these cables should be kept to a total length of 30 m 98.4' or less. | ||||

Specifications
Model |
FD-XC20R4 |
|||
Supported diameter |
Outer diameter of pipe: 1/2 " (12.7 mm) |
|||
Weight |
Approx. 80 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
MD-X1000C*1 |
|||
Type |
Marking unit (controller + head) 13 W Standard area |
|||
2D code reader add-in (sold separately) |
MD-XAD1/MD-XAD1A |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
YVO4 laser, Class 4 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*2 |
||
Wavelength |
1,064 nm |
|||
Output |
13 W |
|||
Q-switch frequency |
CW (continuous wave), 1 to 400 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*2 |
|||
Marking area |
125 x 125 x 42 mm |
|||
Standard working distance (±variable width) |
189 mm (±21 mm) 7.44" (±0.83") |
|||
Marking resolution |
2 µm |
|||
Scan speed |
Max. 12,000 mm/s 472.44"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), user font, TrueType font, OpenType font*3 |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E |
|||
2D code |
QR code, micro QR code, DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, GS1 DataBar Limited, |
|||
Logo image |
Custom character font and logo (CAD) data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary marking, Moving marking (constant, encoder) |
||
Character size (marking height/width) |
0.1 to 125 mm 0.004" to 4.92" |
|||
No. of registered programs |
2,000 max. |
|||
No. of program blocks |
256 |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, contactor control I/O*4 |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*5 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.3 ±0.1 m 0.17" ±0.01" |
|||
Cooling method |
Forced air cooling |
|||
Rated voltage and power consumption |
100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, 650 VA max. |
|||
Environmental resistance |
Enclosure rating |
IP64 (marking head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 23.0 kg |
|||
*1 Type equipped with a contactor control terminal block. | ||||

Specifications
Model |
FR-S01 |
|||
Type |
Short range Standard model |
|||
Measuring range |
Up to 1.5 m 4.9'*1 |
|||
Display range |
Up to 2 m 6.6'*1 |
|||
Measurable dielectric constant of medium |
2 or higher*2 |
|||
Resolution |
1 mm 0.04" |
|||
Precision |
Up to 0.1 m 0.3': ±20 mm 0.79"; |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||
Tank pressure |
-0.1 to +1 Mpa |
|||
Material |
Tank interior |
Lens: PTFE |
||
Housing |
PBT PAR |
|||
Connection diameter |
G3/4 (20 A) |
|||
Output |
No. of control outputs |
Maximum 5 |
||
Control output/auxiliary output |
NPN/PNP open collector (switching type) |
|||
Analog output |
0–20 mA/4–20 mA |
|||
External input |
Short-circuit current: 1.5 mA or less |
|||
Network compatibility |
IO-Link v1.1/COM2 |
|||
Analog output accuracy |
Resolution |
1 mm 0.04"*4 |
||
Zero accuracy |
±0.1 mA (zero point = 4 mA)*4 |
|||
F.S. accuracy |
±0.2 mA (full-scale = 20 mA)*4 |
|||
Power supply |
Power voltage |
24 VDC + 25%/–20% Including ripple Class 2 or LPS |
||
Power consumption |
80 mA or less (Excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
−20°C to +55°C*5*6 -4°F to +131°F |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Temperature of coupling used |
–20 to +85°C -4°F to +185°F (no freezing)*5*6 |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Enclosure rating |
IP67 (IEC60529) |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||
Weight |
Approx. 170 g 6.00 oz |
|||
*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened. | ||||


Specifications
Model |
CA-HX200C |
|||
Image element |
Color CMOS image receiving element, 16× high-speed reading using square-pixel, |
|||
Valid pixel count |
1.92 M pixels, 1600 (H) × 1200 (V) |
|||
Image size |
Equivalent to 2/3 " |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
195 MHz (×16 speed) *1 |
|||
Electronic shutter |
Can be set to 0.01 to 100 msec by specifying the following numerical inputs: |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (no condensation) |
|||
Camera cable |
High-speed camera cable CA-CHxx |
|||
Weight |
Approx. 280 g (not including lens) |
|||
*1 When using the CV-X400 or CV-X200 Series with the CA-EC80HX/EC80L | ||||

Specifications
Model |
FS-V34CP |
|||
Type |
2-output with |
|||
Output |
PNP |
|||
Main unit/Expansion unit |
Expansion unit |
|||
Control output |
2 outputs |
|||
Monitor output (1 to 5 V) |
N/A |
|||
External input | ||||
Connector |
M8 |
|||
Light source LED |
Red, 4-element LED (Wavelength: 640 nm) |
|||
Response time |
33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO) |
|||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
|||
Display indicator |
Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and |
|||
Size |
30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D) |
|||
Detection mode |
Light intensity (area detection possible, automatic sensitivity-tracking function provided)/ |
|||
Timer function |
OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable |
|||
Control output |
PNP open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max. |
|||
External inputy |
Input time: 2 ms (ON)/20 ms (OFF) min.*2 |
|||
Unit expansion |
Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units. |
|||
Number of interference prevention units |
Normal operation |
HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台 |
||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal: 830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/ |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*4 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Polycarbonate |
|||
Accessories |
N/A |
|||
Weight |
Approx. 22 g |
|||
*1 Total current of two outputs should be less than 100 mA. | ||||


Specifications
Model |
RC-16 |
|||
Type |
1-level preset counter, DC type |
|||
Function selection |
- |
|||
Operation method |
Addition, subtraction, addition and subtraction (phase difference) |
|||
Operation mode |
Overcount, auto reset, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LCD (character height: 8.5 mm 0.33") |
|||
Number of digits |
6-digit display (zero suppression method), -99,999 to 999,999 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Timer accuracy |
- |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount |
|||
Highest counting speed |
With contacts: 30 c/s, without contacts: 1 kc/s (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less*1 |
||
Control output |
Relay |
Relay output: 20 ms or less (when set to 30 c/s), 5 ms or less (when set to 1 kc/s); |
||
DC output |
- |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Power consumption |
- |
|||
Current consumption |
45 mA or less |
|||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1.2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 75 g |
|||
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. | ||||