Specifications
Model |
SI-F1003*1 |
|||
Type |
Main Controller Separate type*2 |
|||
No. of connectable spectrum units |
2 |
|||
Display |
Minimum display unit |
0.001 µm |
||
Display range |
±999.999 µm to ±9999.99 mm (7 settings selectable) |
|||
Display cycle |
10 times/sec |
|||
Terminal block |
Laser remote interlock input |
Non-voltage or voltage input *3.*4 |
||
TIMING1 input | ||||
RESET1 input | ||||
Auto-zero1 input | ||||
Laser control input | ||||
Analog voltage output |
±10 V x 2 outputs, Output impedance: 100 Ω*4 |
|||
Analog current output |
4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*4 |
|||
Alarm output |
NPN open-collector output (N.C.)*4 |
|||
General comparator output |
NPN open-collector output *5*4 |
|||
Expansion connector |
TIMING2 input |
Non-voltage or voltage input *3.*4 |
||
RESET input | ||||
Auto-zero input | ||||
Program switch input |
Non-voltage input x 3 inputs*4 |
|||
Alarm output |
NPN open-collector output (N.C.)*4 |
|||
Comparator/ binary output |
Binary output |
Measured value data output (21 bits) OUT selectable NPN open-collector output*4 |
||
Strobe output |
NPN open-collector output *5*4 |
|||
Binary selection output | ||||
Binary selection input |
Non-voltage or voltage input *3.*4 |
|||
RS-232C interface |
Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable) |
|||
USB interface |
In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible) |
|||
Ethernet interface |
100BASE-TX/10BASE-T |
|||
Major functions |
12 Out simultaneous measurementcalculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,interferometer mode, mask, connection of setting support software, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
One head connected: 0.6 A or less. Six heads connected: 1.5 A or less. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*6 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 600 g |
|||
*1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3). | ||||

Specifications
Model |
GL-VM56HP |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
56 |
|||
Total length |
1120 mm 44.09" |
|||
Detection height |
1100 mm 43.31" |
|||
Protection height |
1145 mm 45.08" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
6.1 |
|
OFF→ON |
48.7 *3 |
|||
All blocked→ON |
57.2 *4 |
|||
With channel A or B |
ON→OFF |
18.4 |
||
OFF→ON |
67.5 *3 |
|||
All blocked→ON |
93.4 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
129 *5 |
||
Receiver |
140 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
58 *5 |
||
Receiver |
62 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
730 g 25.76 oz |
||
Receiver |
740 g 26.12 oz |
|||
Total |
1470 g 51.89 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
GL-RCG03S |
|||
Number included |
incl. 1 set |
|||
Length |
0.3 m 1.0' |
|||
Note |
One set connects to both transmitter and receiver. |
|||
Weight |
Approx.60 g |
|||

Specifications
Model |
XC-T34B2 |
|||
Rated voltage |
125 VAC/DC |
|||
Rated current |
1 A/pin |
|||
Ambient operating temperature |
−40 to +80°C −40 to +176°F |
|||
Screw torque |
0.8 N·m (max.) |
|||
Applicable wire diameter |
AWG22 to 16 |
|||
Environmental resistance |
Insulation resistance |
500 VDC, 1000 MΩ or greater |
||
Withstand voltage |
500 VAC, 1 minute, 1 mA or less |
|||


Specifications
Model |
OP-87905 |
|||
Type |
Cable between sensor head amplifier |
|||
Length |
10 m 32.81' |
|||
Weight |
Approx. 400 g |
|||

Specifications
Model |
DX-RH1GA |
|||
Display |
Charging Confirmation LED |
2-color LED |
||
Operations |
Hard Keys |
Trigger key × 1 |
||
RFID |
Supported Tags |
ISO/IEC 18000-6 Type C (EPC Global Class 1 Gen 2) |
||
Frequency Range |
902.75 - 927.25 MHz |
|||
Transmission Output |
1 W or less |
|||
Power Source |
Type |
Dedicated lithium ion battery pack (DX-BC6) |
||
Capacity |
6270 mAh |
|||
Interfaces |
Magnet Connector |
Supported (charging/communication) |
||
Dimensions |
182.1 × 100 × 152.4 mm |
|||
Weight |
Approx. 405 g 14.30 oz |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-87098 |
|||
Type |
Fiber Cutter (Gray) |
|||
Overview |
Cutter for free-cut fiber units. (Attached to free-cut fiber units.) |
|||
Applicable product |
FU |
|||
Material |
ABS, stainless |
|||

Specifications
Model |
FD-MZ50AYK*1 |
|||
Type |
Horizontal |
|||
Shape |
Built-in amplifier |
|||
Rated flow range |
0.7 - 13.0 G/min (2.5 - 50 L/min)*1 |
|||
Possible display range |
0.7 - 26.4 G/min (2.5 - 100 L/min)*2 |
|||
Possible ranges to set |
0 - 26.4 G/min (0 - 100 L/min) |
|||
Connection port |
NPT3/4 (20 A) |
|||
Detectable fluids |
Water or non-corrosive liquid |
|||
Conductivity of detection fluids |
5 µS/cm or higher |
|||
Detection fluid temperature |
0 to +85°C 32 to 185 °F (No freezing) |
|||
Pressure loss |
Max. 1.45 PSI (0.01 MPa) |
|||
Display method |
Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator |
|||
Display resolution |
0.1/1 (G/min, L/min) selectable |
|||
Repeatability |
0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3 |
|||
Hysteresis |
Variable |
|||
Response time (chatter prevention feature) |
0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable |
|||
Accumulated flow unit |
0.1/1/10/100/1000 (G, L) selectable |
|||
Integration data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more) |
|||
Analog output |
4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value |
|||
Integration reset/bank switch input/flow zero function input |
Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode |
|||
Power consumption (Current consumption) |
Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA) |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less, Class 2 |
||
Environmental resistance |
Enclosure rating |
IP65 |
||
Pressure resistance |
290 PSI (2.0 MPa) |
|||
Applied pressure range |
Max. 145 PSI (1.0 MPa) |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Liquid end materials |
Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM) |
||
Other materials |
Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC |
|||
Accessory |
Instruction Manual, Connector cable (2.7 m 106.3") |
|||
Weight |
Approx. 1,130 g |
|||
*1 The rated flow range indicates recommended operating range. | ||||

Specifications
Model |
CV-S035MH |
|||
Type |
Camera*1 |
|||
Image element |
1/3-inch monochrome CCD image receiving element, 2x high-speed reading using |
|||
Valid pixel count |
320,000 pixels 656 (H) x 492 (V) *2 |
|||
Pixel transfer frequency |
24.5 MHz |
|||
Scanning system |
progressive (16.0ms), interlace (8.8ms) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values |
|||
Lens mount |
Special mount (M10.5 P0.5 male) |
|||
Environmental resistance |
Ambient temperature |
Head: 0 to +50 °C 32 to 122 °F, relay unit: 0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Head: Approx. 160 g (including the cable, not the lens) |
|||
*1 The CA-CN17 camera cable (17M) and the CA-CN17R high-flex camera cable (17M) cannot be used. | ||||

Specifications
Model |
SV2-M200AK |
|||
General specifications |
Applicable servo amplifier |
SV2-200L2 |
||
Rated output |
1.8 kW |
|||
Rated torque |
11.5 N·m *1 |
|||
Instant maximum torque |
28.7 N·m |
|||
Rated current |
16.7 Arms |
|||
Instant maximum current |
42 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.748 N·m/Arms |
|||
Rotor moment of inertia |
26.0 ×10-4kg·m2 |
|||
Rated power rating |
50.9 kW/s |
|||
Rated angle acceleration |
4420 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
8.8 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
AH-290 |
|||
Type |
Sensor head |
|||
Amplifier unit |
― |
|||
Shape |
Cylindrical, diameter: 90 |
|||
Measuring range |
0 to 35 mm 1.38" |
|||
Analog output voltage |
Output voltage |
0 to 7V |
||
Straight line range |
― |
|||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1.0% of F.S. |
|||
Response |
-1.5 VDC |
|||
Temperature |
Sensor head |
0.08% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
―*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
6VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
― |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F |
|||
Amplifier unit |
― |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Weight |
Sensor head |
― |
||
Weight (including cord) |
Amplifier unit |
|||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||

Specifications
Model |
KV-C64TCP |
|||
Type |
Output unit |
|||
External connection method |
Connector (MIL standard)*1 |
|||
Output |
Number of outputs |
64 points |
||
Output mode |
Transistor (source) |
|||
Rated load |
30 VDC, 0.2 A |
|||
Leakage current at OFF |
100 μA or less |
|||
Residual voltage at ON |
0.5 V or less |
|||
ON resistance |
- |
|||
Common method |
64 points/1 common (4 terminals)*2 |
|||
Operation time |
OFF to ON: 50 μs or less,ON to OFF: 200 μs or less |
|||
Internal current consumption |
100 mA or less |
|||
Weight |
Approx. 140 g |
|||
*1 Connectors for connector-type I/O units are not included XC Series Terminal Block Conversion Unit is available. | ||||

Specifications
Model |
GP-M400 |
|||
Rated pressure |
0 to+5802 PSI |
|||
Possible display range |
-580 to+6382 PSI |
|||
Zero-cut pressure value |
±0.5% of F.S. |
|||
Burst pressure |
14504 PSI (100 MPa) |
|||
Display resolution |
kPa |
None |
||
MPa |
0.01 |
|||
PSI |
1 |
|||
bar |
0.1 |
|||
kgf/cm2 | ||||
Fluid type |
Liquid that will not corrode the liquid contact part |
|||
Type of pressure |
Gage pressure |
|||
Precision |
±1.0% of F.S. or less*1 |
|||
Repeatability |
±0.3% of F.S. or less*2 |
|||
Temperature characteristics |
±0.6% of F.S./10°C 50°F |
|||
Connection port |
G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) |
|||
Box rotation angle |
Maximum 330° |
|||
Medium temperature |
-20 to +100°C -4°F to +212°F (no freezing/condensation)*3 |
|||
Power voltage |
10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS |
|||
Current consumption |
50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 |
|||
Display method |
4 column, digital LED, red/Vertical inversion display possible |
|||
Operation display light |
Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) |
|||
Hysteresis |
During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) |
|||
Response |
Control output |
Selectable from 3 to 5000 ms |
||
Analog output |
As above + 2 ms (90% response) |
|||
Output |
Output 1 control output |
NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) |
||
Output 2 |
Control output |
|||
Analog output |
4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pressure resistance |
50 MPa (500 bar) |
|||
Ambient temperature |
-20 to +80 °C -4 to 176 °F (No freezing and no condensation) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis) |
|||
Shock resistance |
IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) |
|||
Material |
Wetted part |
Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
||
Other parts |
Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU |
|||
Applicable cable |
M12 connector 4 pin |
|||
Weight |
Approx. 150 g |
|||
*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F. | ||||