FR-S01 Keyence

Specifications

Model

FR-S01

Type

Short range Standard model

Measuring range

Up to 1.5 m 4.9'*1

Display range

Up to 2 m 6.6'*1

Measurable dielectric constant of medium

2 or higher*2

Resolution

1 mm 0.04"

Precision

Up to 0.1 m 0.3': ±20 mm 0.79";
0.1 to 0.3 m 0.3' to 1.0' : ±5 mm 0.20";
0.3 to 1.5 m 1.0' to 4.9' : ±1 mm 0.04"
*3

Response time

0.4 s, 1.5 s, 4 s (default value), 10 s

Tank pressure

-0.1 to +1 Mpa

Material

Tank interior

Lens: PTFE
Internal packing: FKM
Joint: SUS304

Housing

PBT PAR

Connection diameter

G3/4 (20 A)

Output

No. of control outputs

Maximum 5

Control output/auxiliary output

NPN/PNP open collector (switching type)
30 VDC or less, max 50 mA for each
Residual voltage of 1.4 V or less (50 mA or less)
N.O./N.C. Switching type
IO2 is switchable to IO-Link
IO5 is switchable to external input

Analog output

0–20 mA/4–20 mA
maximum load resistance 260 Ω
(Response time: 0.2 s after judgment output is confirmed [90% response])

External input

Short-circuit current: 1.5 mA or less
Input time 500 ms or more

Network compatibility

IO-Link v1.1/COM2

Analog output accuracy

Resolution

1 mm 0.04"*4

Zero accuracy

±0.1 mA (zero point = 4 mA)*4

F.S. accuracy

±0.2 mA (full-scale = 20 mA)*4

Power supply

Power voltage

24 VDC + 25%/–20% Including ripple Class 2 or LPS

Power consumption

80 mA or less (Excluding Load Current)

Environmental resistance

Ambient temperature

−20°C to +55°C*5*6 -4°F to +131°F
(no freezing)

Relative humidity

Up to 85% RH (no condensation)

Temperature of coupling used

–20 to +85°C -4°F to +185°F (no freezing)*5*6

Vibration resistance

10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions

Shock resistance

100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Enclosure rating

IP67 (IEC60529)

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges

Weight

Approx. 170 g 6.00 oz

*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened.
*2 Measurement may not be possible depending on the shape and environment of the target.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement errors may occur depending on the customer’s environment.
*4 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment.
*5 The FR-S01 and FR-LM20L/LP20L can be used up to an ambient temperature setpoint of 10°C 50°F by selecting “Off when not in Operation” under “Screen Brightness.”
*6 When performing SIP with the FR-LS20L, do so for 1 hour or less with an ambient temperature of 40°C 104°F or less and an internal system temperature of 130°C 266°F. When performing SIP with the FR-S01/LM20L/LP20L, turn the power supply off, and then perform this operation for 1 hour or less with an ambient temperature of 40°C 104°F or less and an internal system temperature of 130°C 266°F. In addition, always install the KEYENCE optional ferrule mounting bracket and internal gasket.

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price5,627.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
0.00 kr
5,627.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

FR-S01

Type

Short range Standard model

Measuring range

Up to 1.5 m 4.9'*1

Display range

Up to 2 m 6.6'*1

Measurable dielectric constant of medium

2 or higher*2

Resolution

1 mm 0.04"

Precision

Up to 0.1 m 0.3': ±20 mm 0.79";
0.1 to 0.3 m 0.3' to 1.0' : ±5 mm 0.20";
0.3 to 1.5 m 1.0' to 4.9' : ±1 mm 0.04"
*3

Response time

0.4 s, 1.5 s, 4 s (default value), 10 s

Tank pressure

-0.1 to +1 Mpa

Material

Tank interior

Lens: PTFE
Internal packing: FKM
Joint: SUS304

Housing

PBT PAR

Connection diameter

G3/4 (20 A)

Output

No. of control outputs

Maximum 5

Control output/auxiliary output

NPN/PNP open collector (switching type)
30 VDC or less, max 50 mA for each
Residual voltage of 1.4 V or less (50 mA or less)
N.O./N.C. Switching type
IO2 is switchable to IO-Link
IO5 is switchable to external input

Analog output

0–20 mA/4–20 mA
maximum load resistance 260 Ω
(Response time: 0.2 s after judgment output is confirmed [90% response])

External input

Short-circuit current: 1.5 mA or less
Input time 500 ms or more

Network compatibility

IO-Link v1.1/COM2

Analog output accuracy

Resolution

1 mm 0.04"*4

Zero accuracy

±0.1 mA (zero point = 4 mA)*4

F.S. accuracy

±0.2 mA (full-scale = 20 mA)*4

Power supply

Power voltage

24 VDC + 25%/–20% Including ripple Class 2 or LPS

Power consumption

80 mA or less (Excluding Load Current)

Environmental resistance

Ambient temperature

−20°C to +55°C*5*6 -4°F to +131°F
(no freezing)

Relative humidity

Up to 85% RH (no condensation)

Temperature of coupling used

–20 to +85°C -4°F to +185°F (no freezing)*5*6

Vibration resistance

10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions

Shock resistance

100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Enclosure rating

IP67 (IEC60529)

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges

Weight

Approx. 170 g 6.00 oz

*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened.
*2 Measurement may not be possible depending on the shape and environment of the target.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement errors may occur depending on the customer’s environment.
*4 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment.
*5 The FR-S01 and FR-LM20L/LP20L can be used up to an ambient temperature setpoint of 10°C 50°F by selecting “Off when not in Operation” under “Screen Brightness.”
*6 When performing SIP with the FR-LS20L, do so for 1 hour or less with an ambient temperature of 40°C 104°F or less and an internal system temperature of 130°C 266°F. When performing SIP with the FR-S01/LM20L/LP20L, turn the power supply off, and then perform this operation for 1 hour or less with an ambient temperature of 40°C 104°F or less and an internal system temperature of 130°C 266°F. In addition, always install the KEYENCE optional ferrule mounting bracket and internal gasket.

Model

FR-S01

Type

Short range Standard model

Measuring range

Up to 1.5 m 4.9'*1

Display range

Up to 2 m 6.6'*1

Measurable dielectric constant of medium

2 or higher*2

Resolution

1 mm 0.04"

Precision

Up to 0.1 m 0.3': ±20 mm 0.79";
0.1 to 0.3 m 0.3' to 1.0' : ±5 mm 0.20";
0.3 to 1.5 m 1.0' to 4.9' : ±1 mm 0.04"
*3

Response time

0.4 s, 1.5 s, 4 s (default value), 10 s

Tank pressure

-0.1 to +1 Mpa

Material

Tank interior

Lens: PTFE
Internal packing: FKM
Joint: SUS304

Housing

PBT PAR

Connection diameter

G3/4 (20 A)

Output

No. of control outputs

Maximum 5

Control output/auxiliary output

NPN/PNP open collector (switching type)
30 VDC or less, max 50 mA for each
Residual voltage of 1.4 V or less (50 mA or less)
N.O./N.C. Switching type
IO2 is switchable to IO-Link
IO5 is switchable to external input

Analog output

0–20 mA/4–20 mA
maximum load resistance 260 Ω
(Response time: 0.2 s after judgment output is confirmed [90% response])

External input

Short-circuit current: 1.5 mA or less
Input time 500 ms or more

Network compatibility

IO-Link v1.1/COM2

Analog output accuracy

Resolution

1 mm 0.04"*4

Zero accuracy

±0.1 mA (zero point = 4 mA)*4

F.S. accuracy

±0.2 mA (full-scale = 20 mA)*4

Power supply

Power voltage

24 VDC + 25%/–20% Including ripple Class 2 or LPS

Power consumption

80 mA or less (Excluding Load Current)

Environmental resistance

Ambient temperature

−20°C to +55°C*5*6 -4°F to +131°F
(no freezing)

Relative humidity

Up to 85% RH (no condensation)

Temperature of coupling used

–20 to +85°C -4°F to +185°F (no freezing)*5*6

Vibration resistance

10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions

Shock resistance

100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Enclosure rating

IP67 (IEC60529)

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges

Weight

Approx. 170 g 6.00 oz

*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened.
*2 Measurement may not be possible depending on the shape and environment of the target.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement errors may occur depending on the customer’s environment.
*4 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment.
*5 The FR-S01 and FR-LM20L/LP20L can be used up to an ambient temperature setpoint of 10°C 50°F by selecting “Off when not in Operation” under “Screen Brightness.”
*6 When performing SIP with the FR-LS20L, do so for 1 hour or less with an ambient temperature of 40°C 104°F or less and an internal system temperature of 130°C 266°F. When performing SIP with the FR-S01/LM20L/LP20L, turn the power supply off, and then perform this operation for 1 hour or less with an ambient temperature of 40°C 104°F or less and an internal system temperature of 130°C 266°F. In addition, always install the KEYENCE optional ferrule mounting bracket and internal gasket.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator