Servo Drives

16165 products

Showing 13105 - 13128 of 16165 products

Showing 13105 - 13128 of 16165 products
View
Schneider Stock Image
Schneider ATV31HU55N4S304 Schneider
Sale price 28,089.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ATV61HC31N4D Schneider Electric Altivar 61 Variable speed drive

Main

Characteristic Value(s)
Range of Product Altivar 61
Product or Component Type Variable speed drive
Product Specific Application Pumping and ventilation machine
Component name ATV61
Motor power kW 280 kW, 3 phase 380...480 V
315 kW, 3 phase 380...480 V
Maximum Horse Power Rating 450 hp, 3 phase 380...480 V
500 hp, 3 phase 380...480 V
power supply voltage 380...480 V - 15...10 %
supply number of phases 3 phase
Line current 494 A 380 V 3 phase 280 kW / 450 hp
494 A 480 V 3 phase 280 kW / 450 hp
544 A 480 V 3 phase 315 kW / 500 hp
555 A 380 V 3 phase 315 kW / 500 hp
EMC filter Level 3 EMC filter
Variant Without DC choke
Assembly style With heat sink
Apparent power 325.1 kVA 380 V 3 phase 280 kW / 450 hp
365.3 kVA 380 V 3 phase 315 kW / 500 hp
maximum prospective line Isc 50 kA 3 phase
Maximum transient current 739.2 A 60 s, 3 phase
Nominal switching frequency 2.5 kHz
Switching frequency 2...8 kHz adjustable
2.5...8 kHz with derating factor
asynchronous motor control Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio - Energy Saving, quadratic U/f
Synchronous motor control profile Vector control without sensor, standard
Communication Port Protocol CANopen
Modbus
Type of polarization No impedance Modbus
Option card Communication card APOGEE FLN
Communication card BACnet
Communication card CC-Link
Controller inside programmable card
Communication card DeviceNet
Communication card EtherNet/IP
Communication card Fipio
I/O extension card
Communication card Interbus-S
Communication card LonWorks
Communication card METASYS N2
Communication card Modbus Plus
Communication card Modbus TCP
Communication card Modbus/Uni-Telway
Multi-pump card
Communication card Profibus DP
Communication card Profibus DP V1

Complementary

Characteristic Value(s)
Product destination Synchronous motors
Asynchronous motors
power supply voltage limits 323…528 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Continuous output current 616 A 2.5 kHz, 380 V - 3 phase
616 A 2.5 kHz, 460 V - 3 phase
Output frequency 0.1…500 Hz
Speed range 1…100 in open-loop mode, without speed feedback
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
Transient overtorque 130 % of nominal motor torque +/- 10 % 60 s
Braking torque <= 125 % with braking resistor
30 % without braking resistor
Regulation loop Frequency PI regulator
Motor slip compensation Not available in voltage/frequency ratio (2 or 5 points)
Can be suppressed
Automatic whatever the load
Adjustable
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
electrical isolation Between power and control terminals
type of cable for mounting in an enclosure With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection Terminal 2.5 mm² / AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal 4 x 185 mm² / 3 x 350 kcmil L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)
Terminal 4 x 185 mm² / 3 x 350 kcmil PC/-, PO, PA/+)
Tightening torque 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
362.9 lbf.in (41 N.m), 360 lb.in PC/-, PO, PA/+)
362.9 lbf.in (41 N.m), 360 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC, +/- 5 %, <10 mA overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
External supply 24 V DC 19…30 V)
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign
AI2 software-configurable current 0...20 mA 242 Ohm 11 bits
AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
sampling time 2 ms +/- 0.5 ms AI1-/Al1+) - analog input
2 ms +/- 0.5 ms Al2) - analog input
2 ms +/- 0.5 ms AO1) - analog output
2 ms +/- 0.5 ms LI1...LI5) - discrete input
2 ms +/- 0.5 ms LI6)if configured as logic input - discrete input
absolute accuracy precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % AI2) for a temperature variation 60 °C
+/- 1 % AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value AI1-/Al1+)
+/- 0.15 % of maximum value AI2)
+/- 0.2 % AO1)
Analogue output number 1
Analogue output type AO1 software-configurable current 0...20 mA 500 Ohm 10 bits
AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits
AO1 software-configurable logic output 10 V, 20 mA
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic R2A, R2B) NO - 100000 cycles
maximum response time <= 100 ms in STO (Safe Torque Off)
R1A, R1B, R1C <= 7 ms +/- 0.5 ms
R2A, R2B <= 7 ms +/- 0.5 ms
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current R1, R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms
R1, R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms
R1, R2 5 A 250 V AC resistive, cos phi = 1 0 ms
R1, R2 5 A 30 V DC resistive, cos phi = 1 0 ms
Discrete input number 7
Discrete input type Programmable LI1...LI5) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm
Switch-configurable LI6) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm
Switch-configurable PTC probe LI6)0…6 - 1500 Ohm
Safety input PWR) 24 V DC <= 30 V) - 1500 Ohm
Discrete input logic Negative logic (sink) LI1...LI5), > 16 V, < 10 V
Positive logic (source) LI1...LI5), < 5 V, > 11 V
Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V
Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps S, U or customized
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
Braking to standstill By DC injection
Protection type Against exceeding limit speed drive
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Power removal drive
Short-circuit between motor phases drive
Thermal protection drive
Motor phase break motor
Power removal motor
Thermal protection motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Connector type 1 RJ45 on front face)Modbus
1 RJ45 on terminal)Modbus
Male SUB-D 9 on RJ45CANopen
Physical interface 2-wire RS 485 Modbus
Transmission frame RTU Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
9600 bps, 19200 bps Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format 8 bits, 1 stop, even parity Modbus on front face
8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses 1…127 CANopen
1…247 Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Product Weight 308.6 lb(US) (140 kg)
Width 23.4 in (595 mm)
Height 37.4 in (950 mm)
Depth 14.8 in (377 mm)
Schneider Stock Image
Schneider ATV303HU22N4E Schneider
Sale price 5,762.00 kr
Only 3 units left
Buy the Schneider Electric ATV303HU22N4E - a genuine Schneider Electric industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Schneider Electric ATV303HU22N4E is a direct drop-in replacement for existing installations and ships ready for integration.
ILS2K571PB1A0 Schneider
Schneider ILS2K571PB1A0 Schneider
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Lexium integrated drive
Product or Component Type Motion integrated drive
Device short name ILS
Motor Type 3-phase stepper motor
Number of motor poles 6
Phase Single phase
[Us] rated supply voltage 48 V
24 V
Network type DC
Communication interface Ethernet/IP, Integrated
Length 4.01 in (101.9 mm)
Winding type Medium speed of rotation and medium torque
Electrical Connection Printed circuit board connector
Holding brake Without
Gear box type Without
Nominal speed 1000 rpm 24 V
2000 rpm 48 V
Nominal torque 3.98 lbf.in (0.45 N.m)
Holding torque 3.98 lbf.in (0.45 N.m)

Complementary

Characteristic Value(s)
Transmission Rate 125, 250, 500 kbauds
Mounting Support Flange
Motor flange size 2.2 in (57 mm)
Number of motor stacks 1
Centring collar diameter 1.5 in (38.1 mm)
centring collar depth 0.06 in (1.6 mm)
Number of mounting holes 4
Mounting holes diameter 0.2 in (5.2 mm)
Circle diameter of the mounting holes 2.6 in (66.6 mm)
Feedback type Index pulse
Shaft end Untapped
Second shaft Without second shaft end
Shaft diameter 0.25 in (6.35 mm)
Shaft length 0.8 in (21 mm)
Supply voltage limits 18…55 V
Current consumption 3500 mA maximum continuous
Associated fuse rating 16 A
Commissioning interface RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)
Input/output type 4 signals (each be used as input or output)
Voltage state 0 guaranteed -3...4.5 V
Voltage state 1 guaranteed 15...30 V
Discrete input current 10 mA at 24 V safety input
2 mA at 24 V 24 V signal interface
Discrete output voltage 23...25 V
Maximum switching current 100 mA per output
200 mA total
Protection Type Safe torque off
Overload of output voltage
Short circuit of the output voltage
Peak stall torque 3.98 lbf.in (0.45 N.m)
Continuous stall torque 3.98 lbf.in (0.45 N.m)
Speed feedback resolution 20000 points/turn
Accuracy error +/- 6 arc min
Rotor inertia 0.1 kg.cm²
Maximum mechanical speed 3000 rpm
Maximum radial force Fr 24 N
Maximum axial force Fa 100 N tensile force)
8.4 N force pressure)
Service life in hours 20000 h bearing
Marking CE
type of cooling Natural convection
Product Weight 2.9 lb(US) (1.3 kg)
ATV950C16N4F Schneider
Schneider ATV950C16N4F Schneider
Sale price0.00 kr
Sold Out

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 160kW for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 132kW for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380Vac to 440Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.

Main

Characteristic Value(s)
Range of product Altivar Process ATV900
Product specific application Process for industrial
Product or component type Variable speed drive
Variant With load break switch
Without braking chopper
Device application Industrial application
Product destination Asynchronous motors
Synchronous motors
Network number of phases 3 phases
Mounting mode Floor-standing
Continuous output current 302 A at 2.5 kHz for normal duty
250 A at 2.5 kHz for heavy duty
Communication port protocol Modbus serial
Modbus TCP
EtherNet/IP
Option card Slot A: communication module for Profibus DP V1
Slot A: communication module for PROFINET
Slot A: communication module for DeviceNet
Slot A: communication module for EtherCAT
Slot A: communication module for CANopen daisy chain RJ45
Slot A: communication module for CANopen SUB-D 9
Slot A: communication module for CANopen screw terminals
Slot A/slot B/slot C: digital and analog I/O extension module
Slot A/slot B/slot C: output relay extension module
Slot B: 5/12 V digital encoder interface module
Slot B: analog encoder interface module
Slot B: resolver encoder interface module
communication module for Ethernet Powerlink
[Us] rated supply voltage 380...440 V - 15...10 %
[Us] rated supply voltage 380...440 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 302.0 A
Motor power kW 160.0 kW for normal duty
132.0 kW for heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP54

Complementary

Characteristic Value(s)
Electrical connection Control: removable screw terminals 0.5...1.5 mm²
Line side: M12 bar
Motor: M12 bar
Transmission rate 10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization No impedance for Modbus serial
Number of addresses 1…247 for Modbus serial
Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling Local diagnostic: 3 LED (mono/dual colour)
Embedded communication status: 5 LED (dual colour)
Communication module status: 2 LED (dual colour)
Presence of voltage: 1 LED (red)
Input compatibility DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2
DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Sampling duration 2 ms +/- 0.5 ms (DI1...DI8) - discrete input
5 ms +/- 1 ms (DI7, DI8) - pulse input
1 ms +/- 1 ms (AI1, AI2, AI3) - analog input
5 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Isolation Between power and control terminals
Discrete input number 10
Discrete input type DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
Discrete input logic 16 preset speeds
Discrete output number 2
Discrete output type Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number 3
Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
Maximum switching current Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Physical interface Ethernet
2-wire RS 485
Connector type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible False
Asynchronous motor control profile Optimized torque mode
Variable torque standard
Constant torque standard
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Can be suppressed
Not available in permanent magnet motor law
Automatic whatever the load
Adjustable
Switching frequency 2.5...8 kHz with derating factor
2...8 kHz adjustable
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated False
Line current 291.0 A at 380 V (normal duty)
244.0 A at 380 V (heavy duty)
251.0 A at 440 V (normal duty)
210.0 A at 440 V (heavy duty)
Maximum input current 291.0 A
Maximum output voltage 440.0 V
Apparent power 192 kVA at 400 V (normal duty)
161 kVA at 400 V (heavy duty)
Maximum transient current 362 A during 60 s (normal duty)
375 A during 60 s (heavy duty)
Network frequency 50...60 Hz
Prospective line Isc 50 kA
Base load current at high overload 250.0 A
Base load current at low overload 302.0 A
Power dissipation in W 3120 W, switching frequency 2.5 kHz (normal duty)
4030 W, switching frequency 2.5 kHz (heavy duty)
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Quantity per set 1
Width 400 mm
Height 2350 mm
Depth 669 mm
Product weight 330 kg
Schneider Stock Image
Schneider ATV93090N4Z Schneider
Sale price 132,359.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Schneider Stock Image
Schneider ATV782D75Y Schneider
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ATV212WU55N4C Schneider
Schneider ATV212WU55N4C Schneider
Sale price0.00 kr
Sold Out

Variable Speed Drive Altivar ATV212 - 5.5kW - 7.5hp - 480V - 3ph - EMC class C1 - IP55

ATV21HD22M3X Schneider Electric
Schneider ATV21HD22M3X Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Altivar 21
Product or Component Type Variable speed drive
Product destination Asynchronous motors
Product Specific Application Pumps and fans in HVAC
Assembly style With heat sink
Component name ATV21
EMC filter Without EMC filter
power supply voltage 200...240 V - 15...10 %
Phase 3 phase
Motor power kW 22 kW
Maximum Horse Power Rating 30 hp
Line current 66.4 A 240 V
80.4 A 200 V
Speed range 1…10
Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s
Asynchronous motor control profile Constant voltage/frequency ratio
Constant voltage/frequency ratio with automatic IR compensation
Quadratic voltage/frequency ratio
Current flux vector control (FVC) without speed feedback
Energy saving ratio
Communication Port Protocol Modbus
Type of polarization No impedance
IP degree of protection IP20 on upper part without blanking plate on cover EN/IEC 60529
IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1
IP21 EN/IEC 60529
IP21 EN/IEC 61800-5-1
IP41 on upper part EN/IEC 60529
IP41 on upper part EN/IEC 61800-5-1
Option card Communication card APOGEE FLN
Communication card BACnet
Communication card LonWorks
Communication card METASYS N2

Complementary

Characteristic Value(s)
power supply voltage limits 170…264 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
Apparent power 33.5 kVA 240 V
maximum prospective line Isc 22 kA
maximum continuous output current 88 A 230 V
Maximum transient current 96.8 A 60 s
Speed drive output frequency 0.5…200 Hz
Nominal switching frequency 8 kHz
Switching frequency 6...16 kHz adjustable
8...16 kHz with derating factor
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Torque accuracy +/- 15 %
Regulation loop Adjustable PI regulator
Motor slip compensation Automatic whatever the load
Not available in voltage/frequency ratio motor control
Adjustable
diagnostic 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14
L1/R, L2/S, L3/T terminal 0.08 in² (50 mm²) / AWG 1/0
Tightening torque 5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
212.4 lbf.in (24 N.m), 212 lb.in L1/R, L2/S, L3/T)
Supply Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Analogue input number 2
Analogue input type VIA switch-configurable current 0...20 mA 242 Ohm 11 bits
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
VIB configurable PTC probe 0...6 probes 1500 Ohm
VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
Sampling duration F 2 ms +/- 0.5 ms discrete
R 2 ms +/- 0.5 ms discrete
RES 2 ms +/- 0.5 ms discrete
VIA 2 ms +/- 0.5 ms analog
VIB 2 ms +/- 0.5 ms analog
Response time FLA, FLC 7 ms +/- 0.5 ms discrete
FLB, FLC 7 ms +/- 0.5 ms discrete
FM 2 ms +/- 0.5 ms analog
RY, RC 7 ms +/- 0.5 ms discrete
Accuracy +/- 1 % FM) for a temperature variation 60 °C
+/- 0.6 % VIA) for a temperature variation 60 °C
+/- 0.6 % VIB) for a temperature variation 60 °C
Linearity error FM +/- 0.2 % output
VIA +/- 0.15 % of maximum value input
VIB +/- 0.15 % of maximum value input
Analogue output number 1
Analogue output type FM switch-configurable current 0...20 mA 500 Ohm 10 bits
FM switch-configurable voltage 0...10 V DC 470 Ohm 10 bits
Discrete output number 2
Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles
Configurable relay logic FLB, FLC) NC - 100000 cycles
Configurable relay logic RY, RC) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 3500 Ohm
R programmable 24 V DC level 1 PLC 3500 Ohm
RES programmable 24 V DC level 1 PLC 3500 Ohm
Discrete input logic Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load
Braking to standstill By DC injection
Protection type Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Short-circuit between motor phases drive
Thermal power stage drive
Motor phase break motor
Thermal protection motor
With PTC probes motor
Against exceeding limit speed drive
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Connector Type 1 RJ45
Physical interface 2-wire RS 485
Transmission frame RTU
Transmission Rate 9600 bps or 19200 bps
Data format 8 bits, 1 stop, odd even or no configurable parity
Number of addresses 1…247
Communication Service Write multiple registers (16) 2 words maximum
Read device identification (43)
Write single register (06)
Read holding registers (03) 2 words maximum
Time out setting from 0.1 to 100 s
Monitoring inhibitable
Marking CE
Operating position Vertical +/- 10 degree
Height 16.5 in (420 mm)
Width 9.4 in (240 mm)
Depth 4.8 in (122 mm)
Product Weight 60.4 lb(US) (27.4 kg)
ILS1B573PB1A0 Schneider
Schneider ILS1B573PB1A0 Schneider
Sale price 17,844.00 kr
Only 1 unit left

integrated drive ILS with stepper motor - 24..36 V - Profibus DP - 3.5 A

ATV71HD11N4S337 Schneider Electric Altivar 71 Variable speed drive

Main

Characteristic Value(s)
Range of Product Altivar 71
Product or Component Type Variable speed drive
Product Specific Application Complex, high-power machines
Component name ATV71
Motor power kW 11 kW, 3 phase 380...480 V
Maximum Horse Power Rating 15 hp, 3 phase 380...480 V
Maximum motor cable length 164.04 ft (50 m) shielded cable
328.08 ft (100 m) unshielded cable
power supply voltage 380...480 V - 15...10 %
Phase 3 phase
Line current 30 A 480 V 3 phase 11 kW / 15 hp
36.6 A 380 V 3 phase 11 kW / 15 hp
EMC filter Integrated
Assembly style With heat sink
Variant Reinforced version
Apparent power 24.1 kVA 380 V 3 phase 11 kW / 15 hp
Prospective line Isc 22 kA 3 phase
Nominal output current 21 A 4 kHz 460 V 3 phase 11 kW / 15 hp
27.7 A 4 kHz 380 V 3 phase 11 kW / 15 hp
Maximum transient current 41.6 A 60 s 3 phase 11 kW / 15 hp
45.7 A 2 s 3 phase 11 kW / 15 hp
Output frequency 0.1…599 Hz
Nominal switching frequency 4 kHz
Switching frequency 1...16 kHz adjustable
4...16 kHz with derating factor
Asynchronous motor control profile Flux vector control (FVC) with sensor (current vector)
ENA (Energy adaptation) system for unbalanced loads
Sensorless flux vector control (SFVC) (voltage or current vector)
Voltage/frequency ratio (2 or 5 points)
Type of polarization No impedance Modbus

Complementary

Characteristic Value(s)
Product destination Synchronous motors
Asynchronous motors
power supply voltage limits 323…528 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Speed range 1…100 asynchronous motor in open-loop mode, without speed feedback
1…1000 asynchronous motor in closed-loop mode with encoder feedback
1…50 synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn
+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
+/- 5 % in closed-loop mode with encoder feedback
Transient overtorque 170 % +/- 10 % 60 s every 10 minutes
220 % +/- 10 % 2 s
Braking torque <= 150 % with braking or hoist resistor
30 % without braking resistor
Synchronous motor control profile Vector control without speed feedback
Regulation loop Adjustable PI regulator
Motor slip compensation Automatic whatever the load
Suppressable
Not available in voltage/frequency ratio (2 or 5 points)
Adjustable
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
Insulation Electrical between power and control
type of cable for mounting in an enclosure With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal 16 mm², AWG 4 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
26.6 lbf.in (3 N.m), 26.5 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign
AI2 software-configurable current 0...20 mA 242 Ohm 11 bits
AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
input sampling time 2 ms +/- 0.5 ms AI1-/Al1+) - analog
2 ms +/- 0.5 ms Al2) - analog
2 ms +/- 0.5 ms LI1...LI5) - discrete
2 ms +/- 0.5 ms LI6)if configured as logic input - discrete
Response time <= 100 ms in STO (Safe Torque Off)
AO1 2 ms +/- 0.5 ms analog
R1A, R1B, R1C 7 ms +/- 0.5 ms discrete
R2A, R2B 7 ms +/- 0.5 ms discrete
absolute accuracy precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % AI2) for a temperature variation 60 °C
+/- 1 % AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value AI1-/Al1+, AI2)
+/- 0.2 % AO1)
Analogue output number 1
Analogue output type AO1 software-configurable logic output 10 V 20 mA
AO1 software-configurable current 0...20 mA 500 Ohm 10 bits
AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic R2A, R2B) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current R1, R2 2 A 250 V AC inductive, cos phi = 0.4
R1, R2 2 A 30 V DC inductive, cos phi = 0.4
R1, R2 5 A 250 V AC resistive, cos phi = 1
R1, R2 5 A 30 V DC resistive, cos phi = 1
Discrete input number 7
Discrete input type LI1...LI5 programmable 24 V DC level 1 PLC 3500 Ohm
LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm
LI6 switch-configurable PTC probe 0…6 1500 Ohm
PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d
Discrete input logic Negative logic (sink) LI1...LI5), > 16 V, < 10 V
Positive logic (source) LI1...LI5), < 5 V, > 11 V
Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V
Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
S, U or customized
Braking to standstill By DC injection
Protection type Against exceeding limit speed drive
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Short-circuit between motor phases drive
Thermal protection drive
Motor phase break motor
Power removal motor
Thermal protection motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Communication Port Protocol Modbus
CANopen
Connector type 1 RJ45 on front face)Modbus
1 RJ45 on terminal)Modbus
Male SUB-D 9 on RJ45CANopen
Physical interface 2-wire RS 485 Modbus
Transmission frame RTU Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
9600 bps, 19200 bps Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format 8 bits, 1 stop, even parity Modbus on front face
8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses 1…127 CANopen
1…247 Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Height 11.6 in (295 mm)
Depth 8.4 in (213 mm)
Width 8.3 in (210 mm)
Product Weight 17.6 lb(US) (8 kg)
Option card Communication card CC-Link
Controller inside programmable card
Communication card DeviceNet
Communication card EtherNet/IP
Communication card Fipio
I/O extension card
Communication card Interbus-S
Interface card for encoder
Communication card Modbus Plus
Communication card Modbus TCP
Communication card Modbus/Uni-Telway
Overhead crane card
Communication card Profibus DP
Communication card Profibus DP V1
Schneider New Stock Image
Schneider ATV320U22BN4B Schneider
Sale price 4,072.00 kr
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ATV650C25N4F Schneider Electric
Schneider ATV650C25N4F Schneider Electric
Sale price0.00 kr
Sold Out

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 440V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 250kW for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 200kW for applications requiring significant overload (up to 150%). It weighs 420kg and its dimensions are, 600mm wide, 2350mm high, 669mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on the floor. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Main

Characteristic Value(s)
Range of product Altivar Process ATV600
Product specific application Process and utilities
Product or component type Variable speed drive
Variant With disconnect switch
Device short name ATV650
Mounting mode Floor-standing
Communication port protocol Modbus TCP
Ethernet
Ethernet
[Us] rated supply voltage 380...440 V - 15...10 %
[Us] rated supply voltage 380...440 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 477.0 A
IP degree of protection IP54
Product destination Asynchronous motors
Synchronous motors
EMC filter Integrated with 150 m conforming to IEC 61800-3 category C3
IP degree of protection IP54 conforming to IEC 60529
IP54 conforming to IEC 61800-5-1
type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
Motor power kW 250 kW (normal duty)
200 kW (heavy duty)
Line current 391 A at 400 V (heavy duty)
319 A at 380 V (normal duty)
453 A at 380 V (heavy duty)
369 A at 400 V (normal duty)
Continuous output current 477 A at 2.5 kHz for normal duty
370 A at 2.5 kHz for heavy duty
Speed drive output frequency 0.1…500 Hz
Safety function STO (safe torque off) SIL 3
Option card Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Slot A: communication module, Profibus DP V1

Complementary

Characteristic Value(s)
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Discrete input logic 16 preset speeds
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Relay output number 3
Relay output type Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Network number of phases 3 phases
Physical interface Ethernet
2-wire RS 485
Method of access Slave Modbus TCP
Transmission rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frame RTU
Output voltage <= power supply voltage
Permissible temporary current boost 1.5 x In during 60 s (heavy duty)
1.1 x In during 60 s (normal duty)
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Frequency resolution Analog input: 0.012/50 Hz
Display unit: 0.1 Hz
Electrical connection Line side: M12 bar - 2 cables 3 x 120 mm² minimum per phase (normal duty)
Line side: M12 bar - 3 cables 3 x 70 mm² minimum per phase (normal duty)
Line side: M12 bar - 3 cables 3 x 185 mm² maximum per phase (normal duty)
Line side: M12 bar - 4 cables 3 x 120 mm² maximum per phase (normal duty)
Motor: M12 bar - 2 cables 3 x 120 mm² minimum per phase (normal duty)
Motor: M12 bar - 3 cables 3 x 70 mm² minimum per phase (normal duty)
Motor: M12 bar - 3 cables 3 x 185 mm² maximum per phase (normal duty)
Motor: M12 bar - 4 cables 3 x 120 mm² maximum per phase (normal duty)
Line side: M12 bar - 2 cables 3 x 95 mm² minimum per phase (heavy duty)
Line side: M12 bar - 3 cables 3 x 185 mm² maximum per phase (heavy duty)
Line side: M12 bar - 4 cables 3 x 120 mm² maximum per phase (heavy duty)
Motor: M12 bar - 1 cables 3 x 185 mm² minimum per phase (heavy duty)
Motor: M12 bar - 2 cables 3 x 95 mm² minimum per phase (heavy duty)
Motor: M12 bar - 3 cables 3 x 185 mm² maximum per phase (heavy duty)
Motor: M12 bar - 4 cables 3 x 120 mm² maximum per phase (heavy duty)
Control: removable screw terminals 0.5...1.5 mm²
Connector type RJ45 (on the remote graphic terminal) for Modbus serial
RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses 1…247 for Modbus serial
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Local signalling 3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
3 LEDs for local diagnostic
Input compatibility DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Sampling duration 5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AO1) - analog output
2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Accuracy +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Linearity error AO1, AO2: +/- 0.2 % for analog output
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Isolation Between power and control terminals
Discrete and process manufacturing Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Building - HVAC compressor centrifugal
Power range 110…220 kW at 480…500 V 3 phases
250…500 kW at 380…440 V 3 phases
Enclosure mounting Floor-standing
4 quadrant operation possible False
Asynchronous motor control profile Optimized torque mode
Constant torque standard
Variable torque standard
Synchronous motor control profile Synchronous reluctance motor
Permanent magnet motor
Maximum output frequency 500 kHz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Not available in permanent magnet motor law
Automatic whatever the load
Adjustable
Can be suppressed
Switching frequency 2...8 kHz adjustable
2.5...8 kHz with derating factor
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated False
Maximum input current 453.0 A
Maximum output voltage 440.0 V
Apparent power 298 kVA at 440 V (normal duty)
243 kVA at 440 V (heavy duty)
Maximum transient current 525 A during 60 s (normal duty)
555 A during 60 s (heavy duty)
Network frequency 50...60 Hz
Prospective line Isc 50 kA
Base load current at high overload 370.0 A
Base load current at low overload 477.0 A
Power dissipation in W 3380 W, switching frequency 2.5 kHz (heavy duty)
5750 W, switching frequency 2.5 kHz (normal duty)
With safety function Safely Limited Speed (SLS) False
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) False
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Thermal protection: motor
Quantity per set 1
Width 600 mm
Height 2350 mm
Depth 669 mm
Product weight 500 kg
Schneider New Stock Image
Schneider ATV71WU22N4 Schneider
Sale price 77,330.00 kr
Only 1 unit left

Main

Characteristic Value(s)
Range of product Altivar 71
Product or component type Variable speed drive
Product specific application Complex, high-power machines
Component name ATV71
Motor power kW 2.2 kW, 3 phases at 380...480 V
Motor power hp 3 hp, 3 phases at 380...480 V
Maximum motor cable length 50 m shielded cable
100 m unshielded cable
power supply voltage 380...480 V - 15...10 %
Network number of phases 3 phases
Line current 7.1 A for 480 V 3 phases 2.2 kW / 3 hp
8.2 A for 380 V 3 phases 2.2 kW / 3 hp
EMC filter Class A EMC filter integrated
Assembly style Enclosed
Variant With EMC plate
Apparent power 5.4 kVA at 380 V 3 phases 2.2 kW / 3 hp
Prospective line Isc 5 kA for 3 phases
Nominal output current 4.8 A at 4 kHz 460 V 3 phases 2.2 kW / 3 hp
5.8 A at 4 kHz 380 V 3 phases 2.2 kW / 3 hp
Maximum transient current 8.7 A for 60 s 3 phases 2.2 kW / 3 hp
9.6 A for 2 s 3 phases 2.2 kW / 3 hp
Output frequency 0.1…599 Hz
Nominal switching frequency 4 kHz
Switching frequency 1...16 kHz adjustable
4...16 kHz with derating factor
Asynchronous motor control profile ENA (Energy adaptation) system for unbalanced loads
Sensorless flux vector control (SFVC) (voltage or current vector)
Flux vector control (FVC) with sensor (current vector)
Voltage/frequency ratio (2 or 5 points)
Type of polarization No impedance for Modbus

Complementary

Characteristic Value(s)
Product destination Synchronous motors
Asynchronous motors
power supply voltage limits 323…528 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Speed range 1…100 for asynchronous motor in open-loop mode, without speed feedback
1…1000 for asynchronous motor in closed-loop mode with encoder feedback
1…50 for synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn
+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
+/- 5 % in closed-loop mode with encoder feedback
Transient overtorque 170 % of nominal motor torque +/- 10 % for 60 s every 10 minutes
220 % of nominal motor torque +/- 10 % for 2 s
Braking torque <= 150 % with braking or hoist resistor
30 % without braking resistor
Synchronous motor control profile Vector control without speed feedback
Regulation loop Adjustable PI regulator
Motor slip compensation Suppressable
Automatic whatever the load
Adjustable
Not available in voltage/frequency ratio (2 or 5 points)
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
Insulation Electrical between power and control
type of cable for mounting in an enclosure With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Electrical connection Terminal, clamping capacity: 2.5 mm², AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal, clamping capacity: 4 mm², AWG 10 (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
1.4 N.m, 12.3 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign
AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits
AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits
input sampling time 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s)
2 ms +/- 0.5 ms (Al2) - analog input(s)
2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s)
2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s)
Response time <= 100 ms in STO (Safe Torque Off)
AO1 2 ms, tolerance +/- 0.5 ms for analog output(s)
R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s)
R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s)
absolute accuracy precision +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % (AI2) for a temperature variation 60 °C
+/- 1 % (AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value (AI1-/Al1+, AI2)
+/- 0.2 % (AO1)
Analogue output number 1
Analogue output type AO1 software-configurable logic output 10 V 20 mA
AO1 software-configurable current 0...20 mA, impedance: 500 Ohm, resolution 10 bits
AO1 software-configurable voltage 0...10 V DC, impedance: 470 Ohm, resolution 10 bits
Discrete output number 2
Discrete output type Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NO - 100000 cycles
Minimum switching current 3 mA at 24 V DC for configurable relay logic
Maximum switching current R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4
R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4
R1, R2: 5 A at 250 V AC resistive load, cos phi = 1
R1, R2: 5 A at 30 V DC resistive load, cos phi = 1
Discrete input number 7
Discrete input type LI1...LI5: programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm
LI6: switch-configurable 24 V DC with level 1 PLC, impedance: 3500 Ohm
LI6: switch-configurable PTC probe 0…6, impedance: 1500 Ohm
PWR: safety input 24 V DC, impedance: 1500 Ohm conforming to ISO 13849-1 level d
Discrete input logic Negative logic (sink) (LI1...LI5), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (LI1...LI5), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1)
Acceleration and deceleration ramps S, U or customized
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
Braking to standstill By DC injection
Protection type Against exceeding limit speed: drive
Against input phase loss: drive
Break on the control circuit: drive
Input phase breaks: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Overvoltages on the DC bus: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Motor phase break: motor
Power removal: motor
Thermal protection: motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input: 0.024/50 Hz
Display unit: 0.1 Hz
Communication port protocol CANopen
Modbus
Connector type 1 RJ45 (on front face) for Modbus
1 RJ45 (on terminal) for Modbus
Male SUB-D 9 on RJ45 for CANopen
Physical interface 2-wire RS 485 for Modbus
Transmission frame RTU for Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
9600 bps, 19200 bps for Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format 8 bits, 1 stop, even parity for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal
Number of addresses 1…127 for CANopen
1…247 for Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Height 490 mm
Depth 272 mm
Width 240 mm
Product weight 12 kg
Functionality Full
Specific application Other applications
Option card Communication card for CC-Link
Controller inside programmable card
Communication card for DeviceNet
Communication card for EtherNet/IP
Communication card for Fipio
I/O extension card
Communication card for Interbus-S
Interface card for encoder
Communication card for Modbus Plus
Communication card for Modbus TCP
Communication card for Modbus/Uni-Telway
Overhead crane card
Communication card for Profibus DP
Communication card for Profibus DP V1
ATV61HC63N4D Schneider Electric Altivar 61 Variable speed drive

Main

Characteristic Value(s)
Range of Product Altivar 61
Product or Component Type Variable speed drive
Product Specific Application Pumping and ventilation machine
Component name ATV61
Motor power kW 560 kW, 3 phase 380...480 V
630 kW, 3 phase 380...480 V
Maximum Horse Power Rating 800 hp, 3 phase 380...480 V
900 hp, 3 phase 380...480 V
power supply voltage 380...480 V - 15...10 %
supply number of phases 3 phase
Line current 1091 A 380 V 3 phase 630 kW / 900 hp
858 A 480 V 3 phase 560 kW / 800 hp
964 A 480 V 3 phase 630 kW / 900 hp
978 A 380 V 3 phase 560 kW / 800 hp
EMC filter Level 3 EMC filter
Variant Without DC choke
Assembly style With heat sink
Apparent power 718 kVA 380 V 3 phase 630 kW / 900 hp
643.6 kVA 380 V 3 phase 560 kW / 800 hp
maximum prospective line Isc 50 kA 3 phase
Maximum transient current 1425.6 A 60 s, 3 phase
Nominal switching frequency 2.5 kHz
Switching frequency 2...8 kHz adjustable
2.5...8 kHz with derating factor
asynchronous motor control Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio, 2 points
Voltage/frequency ratio - Energy Saving, quadratic U/f
Synchronous motor control profile Vector control without sensor, standard
Communication Port Protocol CANopen
Modbus
Type of polarization No impedance Modbus
Option card Communication card APOGEE FLN
Communication card BACnet
Communication card CC-Link
Controller inside programmable card
Communication card DeviceNet
Communication card EtherNet/IP
Communication card Fipio
I/O extension card
Communication card Interbus-S
Communication card LonWorks
Communication card METASYS N2
Communication card Modbus Plus
Communication card Modbus TCP
Communication card Modbus/Uni-Telway
Multi-pump card
Communication card Profibus DP
Communication card Profibus DP V1

Complementary

Characteristic Value(s)
Product destination Asynchronous motors
Synchronous motors
power supply voltage limits 323…528 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Continuous output current 1188 A 2.5 kHz, 380 V - 3 phase
1188 A 2.5 kHz, 460 V - 3 phase
Output frequency 0.1…500 Hz
Speed range 1…100 in open-loop mode, without speed feedback
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
Transient overtorque 130 % of nominal motor torque +/- 10 % 60 s
Braking torque <= 125 % with braking resistor
30 % without braking resistor
Regulation loop Frequency PI regulator
Motor slip compensation Not available in voltage/frequency ratio (2 or 5 points)
Automatic whatever the load
Adjustable
Can be suppressed
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
electrical isolation Between power and control terminals
type of cable for mounting in an enclosure With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection Terminal 2.5 mm² / AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal 8 x 185 mm² / 5 x 500 kcmil PC/-, PO, PA/+)
Terminal 2 x 4 x 185 mm² / 2 x 3 x 500 kcmil R/L1.1, S/L2.1, T/L3.1, R/L1.2, S/L2.2, T/L3.2)
Terminal 6 x 185 mm² / 5 x 500 kcmil U/T1, V/T2, W/T3)
Tightening torque 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
362.9 lbf.in (41 N.m), 360 lb.in PC/-, PO, PA/+)
362.9 lbf.in (41 N.m), 360 lb.in R/L1.1, S/L2.1, T/L3.1, R/L1.2, S/L2.2, T/L3.2)
362.9 lbf.in (41 N.m), 360 lb.in U/T1, V/T2, W/T3)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC, +/- 5 %, <10 mA overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
External supply 24 V DC 19…30 V)
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign
AI2 software-configurable current 0...20 mA 242 Ohm 11 bits
AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
sampling time 2 ms +/- 0.5 ms AI1-/Al1+) - analog input
2 ms +/- 0.5 ms Al2) - analog input
2 ms +/- 0.5 ms AO1) - analog output
2 ms +/- 0.5 ms LI1...LI5) - discrete input
2 ms +/- 0.5 ms LI6)if configured as logic input - discrete input
absolute accuracy precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % AI2) for a temperature variation 60 °C
+/- 1 % AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value AI1-/Al1+)
+/- 0.15 % of maximum value AI2)
+/- 0.2 % AO1)
Analogue output number 1
Analogue output type AO1 software-configurable current 0...20 mA 500 Ohm 10 bits
AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits
AO1 software-configurable logic output 10 V, 20 mA
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic R2A, R2B) NO - 100000 cycles
maximum response time <= 100 ms in STO (Safe Torque Off)
R1A, R1B, R1C <= 7 ms +/- 0.5 ms
R2A, R2B <= 7 ms +/- 0.5 ms
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current R1, R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms
R1, R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms
R1, R2 5 A 250 V AC resistive, cos phi = 1 0 ms
R1, R2 5 A 30 V DC resistive, cos phi = 1 0 ms
Discrete input number 7
Discrete input type Programmable LI1...LI5) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm
Switch-configurable LI6) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm
Switch-configurable PTC probe LI6)0…6 - 1500 Ohm
Safety input PWR) 24 V DC <= 30 V) - 1500 Ohm
Discrete input logic Negative logic (sink) LI1...LI5), > 16 V, < 10 V
Positive logic (source) LI1...LI5), < 5 V, > 11 V
Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V
Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps S, U or customized
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
Braking to standstill By DC injection
Protection type Against exceeding limit speed drive
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Power removal drive
Short-circuit between motor phases drive
Thermal protection drive
Motor phase break motor
Power removal motor
Thermal protection motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Connector type 1 RJ45 on front face)Modbus
1 RJ45 on terminal)Modbus
Male SUB-D 9 on RJ45CANopen
Physical interface 2-wire RS 485 Modbus
Transmission frame RTU Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
9600 bps, 19200 bps Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format 8 bits, 1 stop, even parity Modbus on front face
8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses 1…127 CANopen
1…247 Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Product Weight 661.4 lb(US) (300 kg)
Width 44.09 in (1120 mm)
Height 45.3 in (1150 mm)
Depth 14.8 in (377 mm)
Schneider Stock Image
Schneider ILM1003P12F0000 Schneider
Sale price 22,213.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ATV212HU30N4 Schneider
Schneider ATV212HU30N4 Schneider
Sale price 4,548.00 kr
In stock, 13 units

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 3kW and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 3.35kg and its dimensions are, 142mm wide, 184mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.

Main

Characteristic Value(s)
Device short name ATV212
Product destination Asynchronous motors
Phase 3 phase
Motor power kW 3 kW
Maximum Horse Power Rating 4 hp
Supply voltage limits 323…528 V
Supply frequency 50...60 Hz - 5...5 %
Line current 4.9 A 480 V
6.2 A 380 V
Range of Product Altivar 212
Product or Component Type Variable speed drive
Product Specific Application Pumps and fans in HVAC
Communication Port Protocol METASYS N2
LonWorks
Modbus
BACnet
APOGEE FLN
[Us] rated supply voltage 380...480 V - 15...10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP21

Complementary

Characteristic Value(s)
Apparent power 5.5 kVA 380 V
Continuous output current 7.2 A 380 V
7.2 A 460 V
Maximum transient current 7.9 A 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14
L1/R, L2/S, L3/T terminal 0.009 in² (6 mm²) / AWG 10
Tightening torque 11.5 lbf.in (1.3 N.m), 11.5 lb.in L1/R, L2/S, L3/T)
5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms +/- 0.5 ms analog
FLA, FLC 7 ms +/- 0.5 ms discrete
FLB, FLC 7 ms +/- 0.5 ms discrete
RY, RC 7 ms +/- 0.5 ms discrete
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C
+/- 0.6 % VIB) for a temperature variation 60 °C
+/- 1 % FM) for a temperature variation 60 °C
Linearity error VIA +/- 0.15 % of maximum value input
VIB +/- 0.15 % of maximum value input
FM +/- 0.2 % output
Analogue output type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits
FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles
Configurable relay logic FLB, FLC) NC - 100000 cycles
Configurable relay logic RY, RC) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm
R programmable 24 V DC level 1 PLC 4700 Ohm
RES programmable 24 V DC level 1 PLC 4700 Ohm
Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit 0.1 Hz
Analog input 0.024/50 Hz
Communication Service Write multiple registers (16) 2 words maximum
Read holding registers (03) 2 words maximum
Time out setting from 0.1 to 100 s
Read device identification (43)
Monitoring inhibitable
Write single register (06)
Option card Communication card LonWorks
Power dissipation in W 137 W
air flow 12416.3 Gal/hr(US) (47 m3/h)
Functionality Mid
Specific application HVAC
Variable speed drive application selection Building - HVAC compressor for scroll
Building - HVAC fan
Building - HVAC pump
Motor power range AC-3 2.2…3 kW 380…440 V 3 phase
2.2…3 kW 480…500 V 3 phase
Motor starter type Variable speed drive
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable PTC probe 0...6 probes 1500 Ohm
VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector Type 1 open style
1 RJ45
Transmission Rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio, 2 points
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor, standard
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s
Acceleration and deceleration ramps Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Motor slip compensation Adjustable
Automatic whatever the load
Not available in voltage/frequency ratio motor control
Switching frequency 6...16 kHz adjustable
12...16 kHz with derating factor
Nominal switching frequency 12 kHz
Braking to standstill By DC injection
Network Frequency 47.5...63 Hz
Prospective line Isc 5 kA
Protection type Overheating protection drive
Thermal power stage drive
Short-circuit between motor phases drive
Input phase breaks drive
Overcurrent between output phases and earth drive
Overvoltages on the DC bus drive
Break on the control circuit drive
Against exceeding limit speed drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Against input phase loss drive
Thermal protection motor
Motor phase break motor
With PTC probes motor
Width 5.6 in (142 mm)
Height 7.2 in (184 mm)
Depth 5.9 in (150 mm)
Product Weight 7.39 lb(US) (3.35 kg)
ATV31HU15S6X Schneider
Schneider ATV31HU15S6X Schneider
Sale price 15,944.00 kr
Only 1 unit left

variable speed drive - ATV31 - 1.5kW - 525..600V - 3-phase supply - IP20

Schneider Stock Image
Schneider ATV38HU41N4 Schneider
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ATV950D15N4 Schneider Electric
Schneider ATV950D15N4 Schneider Electric
Sale price0.00 kr
Sold Out

Variable Speed Drive - ATV950 - 15kW - 400/480V - with braking unit - IP55

ILS1R573PB1A0 Schneider
Schneider ILS1R573PB1A0 Schneider
Sale price 11,500.00 kr
Only 1 unit left

Main

Characteristic Value(s)
Range of Product Lexium integrated drive
Product or Component Type Motion integrated drive
Device short name ILS
Motor Type 3-phase stepper motor
Number of motor poles 6
Phase Single phase
[Us] rated supply voltage 36 V
24 V
Network type DC
Communication interface RS485, Integrated
Length 5.5 in (138.9 mm)
Winding type Medium speed of rotation and medium torque
Electrical Connection Printed circuit board connector
Holding brake Without
Gear box type Without
Nominal speed 200 rpm 24 V
500 rpm 36 V
Nominal torque 13.3 lbf.in (1.5 N.m)
Holding torque 15.05 lbf.in (1.7 N.m)

Complementary

Characteristic Value(s)
Transmission Rate 9.6, 19.2 and 38.4 kbauds
Mounting Support Flange
Motor flange size 2.2 in (57 mm)
Number of motor stacks 3
Centring collar diameter 1.5 in (38.1 mm)
centring collar depth 0.06 in (1.6 mm)
Number of mounting holes 4
Mounting holes diameter 0.2 in (5.2 mm)
Circle diameter of the mounting holes 2.6 in (66.6 mm)
Feedback type Index pulse
Shaft end Untapped
Second shaft Without second shaft end
Shaft diameter 0.3 in (8 mm)
Shaft length 0.8 in (21 mm)
Supply voltage limits 18…40 V
Current consumption 3500 mA maximum
Associated fuse rating 10 A
Input/output type 4 signals (each be used as input or output)
Voltage state 0 guaranteed -3...4.5 V
Voltage state 1 guaranteed 15...30 V
Discrete input current 10 mA at 24 V on/STO_A safety input
3 mA at 24 V on/STO_B safety input
2 mA at 24 V 24 V signal interface
Discrete output voltage 23...25 V
Maximum switching current 100 mA per output
200 mA total
Protection Type Short circuit of the output voltage
Safe torque off
Overload of output voltage
Peak stall torque 13.3 lbf.in (1.5 N.m)
Continuous stall torque 13.3 lbf.in (1.5 N.m)
Speed feedback resolution 20000 points/turn
Accuracy error +/- 6 arc min
Rotor inertia 0.38 kg.cm²
Maximum mechanical speed 3000 rpm
Maximum radial force Fr 50 N
Maximum axial force Fa 100 N tensile force)
8.4 N force pressure)
Service life in hours 20000 h bearing
Marking CE
type of cooling Natural convection
Product Weight 4.4 lb(US) (2 kg)
ATV320U06M2W Schneider
Schneider ATV320U06M2W Schneider
Sale price0.00 kr
Sold Out

Altivar Machine ATV320 range is an offer of variable speed drives designed for Original Equipment Manufacturers (OEMs). This drive can feed single phase synchronous and asynchronous motors, and is enclosed for higher IP protection. It works at a rated power up to 0.55kW / 0.75hp and a rated voltage from 200V to 240V AC. Altivar high IP offers washable drives for harsh environments, if users want to clean the dust and chemical pollution outside of drives. It is delivered without fan, with embedded EMC C2 filter and it provides IP66 protection. It also incorporates parallel connection of motors and special drives using the voltage/frequency ratio and static speed accuracy and energy saving for open-loop synchronous motors. It weighs 5.1kg and its dimensions are 250mm wide, 340mm high, 182mm deep. The drive software includes 5 safety functions that help machines meet safety requirements. These safety functions are configured using SoMove software. This Altivar Machine ATV320 is designed for conveyors, carton packers, gantry cranes, woodworking, metal processing, fans, Food & Beverage industry. It conforms to IEC, UL, TUV, KC and other international standards. Mounting accessories and external options (braking resistors, line chokes, motor chokes, additional EMC filters) are available with Altivar Machine ATV320 drives. The type of external accessories and options depends on the drive rating. The product is delivered in two packages. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV320 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Main

Characteristic Value(s)
Range of Product Altivar Machine ATV320
Product or Component Type Variable speed drive
Product Specific Application Complex machines
Variant Standard version
Format of the drive Enclosed
Mounting Mode Wall mount
Communication Port Protocol Modbus serial
CANopen
Option card communication module, CANopen
communication module, EtherCAT
communication module, Profibus DP V1
communication module, PROFINET
communication module, Ethernet Powerlink
communication module, EtherNet/IP
communication module, DeviceNet
[Us] rated supply voltage 200...240 V - 15...10 %
nominal output current 3.7 A
Motor power kW 0.55 kW heavy duty
EMC filter Class C2 EMC filter integrated
IP degree of protection IP66

Complementary

Characteristic Value(s)
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC1.5 kOhm
DI1...DI6 logic inputs, 24 V DC 30 V)
DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage 0...10 V DC 30 kOhm 10 bits
AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits
AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits
Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Relay output type Configurable relay logic R1A 1 NO 100000 cycles
Configurable relay logic R1B 1 NC 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
Method of access Slave CANopen
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensation Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 7.8 A 200 V heavy duty)
6.6 A 240 V heavy duty)
Maximum Input Current per Phase 7.8 A
Maximum output voltage 240 V
Apparent power 1.6 kVA 240 V heavy duty)
Network Frequency 50-60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 1 kA
Base load current at high overload 1.9 A
Power dissipation in W Self-cooled 33.0 W 200 V 4 kHz
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks drive
Overcurrent between output phases and earth drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection drive
Width 9.8 in (250 mm)
Height 13.4 in (340 mm)
Depth 7.2 in (182.0 mm)
Product Weight 11.2 lb(US) (5.1 kg)
Transient overtorque 170…200 % of nominal motor torque
Schneider New Stock Image
Schneider ATV212HD3ONY Schneider
Sale price 15,020.00 kr
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider ATV66U41N4 Schneider
Sale price 4,652.00 kr
Only 1 unit left

Main

Characteristic Value(s)
Range of Product Altivar 66
Product or Component Type Variable speed drive

Complementary

Characteristic Value(s)
Product destination Asynchronous motors
[Us] rated supply voltage 380...460 V - 10...10 %
Supply frequency 50...60 Hz - 5...5 %
Network Frequency 47.5...63 Hz
Phase 3 phase
Motor power kW 2.2 kW 380...460 V
Maximum Horse Power Rating 3 hp
Line current 13.4 A 380 V
11.4 A 460 V
Apparent power 4.1 kVA 400 V
Continuous output current 5.8 A 400 V
Output frequency 0…0.3 kHz
Nominal switching frequency 2.5 kHz
Switching frequency 0.5...4 kHz
8...16 kHz with current derating
Local signalling 1 graphic display terminal
Output voltage 400 V
Communication Port Protocol Modbus
Physical interface RS485 multidrop serial link
Transmission Rate 9.6...19.2 kbauds
Height 11.6 in (295 mm)
Width 7.9 in (200 mm)
Depth 6.5 in (165 mm)
Option card Communication card Profibus DP
Communication card CANopen
Communication card DeviceNet
Communication card Ethernet
Communication card Fipio
Communication card Uni-Telway
Communication card Interbus-S
Communication card Modbus Plus
Communication card AS-Interface

Recently viewed