
Material Compliance
Environmental
Ordering
4377335
8015644518196
1 piece
85389099
Dimensions
0.96 kg
Container Information
1 piece
210 mm
170 mm
240 mm
1.06 kg
8015644518196
Additional Information
Accessories for Tmax T
Accessory
ACC
T1
SACE Tmax T
Technical
Loose or configurable
T1
3P
IEC
Certificates and Declarations
External Classifications and Standards
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZABREHBE000A000000XX
8015644753054
1 piece
85362090
Dimensions
280 mm
296 mm
183 mm
16 kg
Container Information
box 1 piece
350 mm
350 mm
330 mm
18 kg
8015644753054
Additional Information
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
100 %
4P
122 W
1250 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
100 %
for 1 s 42 kA
for 3 s 24 kA
for 1 s 42 kA
for 3 s 24 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
1250 A
690 V
Main Circuit M10
Ekip Touch LSI
EL
B
IEC
E1.2
Yes, 690V
Front
Bolt
45 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KT5ES-6
3180934
8015644561833
1 piece
85389099
Dimensions
1.4 kg
Container Information
1 piece
170 mm
35 mm
230 mm
1.4 kg
8015644561833
Additional Information
Accessories for Tmax T
Accessory
Accessory
T5
SACE Tmax T
Technical
Loose or configurable
3P
IEC
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZBSREHAQ200A000000XX
8015644768003
1 piece
85362090
Dimensions
407 mm
425 mm
383 mm
55 kg
Container Information
box 1 piece
515 mm
610 mm
615 mm
60 kg
8015644768003
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
100 %
4P
176 W
1250 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
1250 A
690 V
Ekip G Hi-Touch LSIG
EL
S
IEC
E2.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 60 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT6HE3800GFF000XXX
8056221008211
1 piece
85362090
Dimensions
210 mm
268 mm
103.5 mm
9.5 kg
Container Information
box 1 piece
305 mm
285 mm
370 mm
11 kg
8056221008211
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
AC
5000 cycle
60 cycles per hour
5000 cycle
60 cycles per hour
20000 cycle
120 cycles per hour
20000 cycle
120 cycles per hour
3P
1 piece
53.4 W
800 A
8 kV
1000 V
690 V AC
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 25 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 25 kA
10 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 25 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 2 Poles in Series 50 kA
(750 V DC) 3 Poles in Series 36 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 25 kA
(250 V DC) 2 Poles in Series 70 kA
800 A
Ekip Dip LSIG
EL
H
IEC60947-2
XT6
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
T7MLFC3AC000000XX
8015644656249
1 piece
85362090
Dimensions
210 mm
268 mm
178 mm
11 kg
Container Information
1 piece
280 mm
350 mm
360 mm
12.5 kg
8015644656249
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
T7M
Moulded Case Circuit Breakers
F
Technical
2000 cycle
60 cycles per hour
2000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
3P
at Rated Operating Conditions per Pole 77 W
1600 A
8 kV
1000 V
690 V AC
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 64 kA
(690 V AC) 37.5 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 64 kA
(690 V AC) 37.5 kA
for 1 s 20 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(690 V AC) 50 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(690 V AC) 50 kA
1600 A
PR232/P-LSI
EL
L
IEC
T7
Fixed Circuit-Breakers
Front
Fixed Circuit-Breakers
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 59.6 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
6ec8fe9c-35cc-465d-820a-ddaa8f459a25 Italy
c8c90e9d-7c70-4379-96fd-a9ae6e6f1300 Germany
d0900ff7-a757-4fae-a881-a5ea25351c51 Germany
9b07e73f-14d1-4af1-9110-b8729f7402a2 France
1ad62dc8-d90d-4210-b193-abc6073a67d1 Netherlands
4b23fb89-fe2c-4410-bb42-7289f5302151 Spain
c9ce231f-a540-402b-914b-56397cad868a Netherlands
3a1436a8-4a07-462c-8f47-ffbf4c6edb63 Bulgaria
4978c3e4-b48b-4753-98bb-afdbf6490a07 Sweden
5fc59b9e-999c-48b4-a1e4-ec0f65261b4f Poland
7fbd870b-b6ac-4dbd-96ee-efc6241fb2dd France
80841d8b-b4a7-45a3-9c5b-6b33269890f7 Sweden
41f6ce1e-07b4-4cef-a89d-70321e8d8e4b Greece
c62e49f2-6aaf-4fec-bf1a-29b933eff264 Germany
e8c252fe-cd80-4dc9-8ab0-2c27501bb96e Poland
e6573a9b-6cca-49ba-9817-a8923496bfa5 Norway
9dab5e1f-6113-4646-86e3-0641a27ce089 Finland
c65804ad-6e27-4de9-aa6e-595f51ec3530 Netherlands
a58a46b9-21ca-4071-b3f6-13ce22ee89b5 Germany
6fe5a1fb-9b7a-4954-b0d0-677b146c7b46 Denmark
8806fe7b-7636-410b-bf82-b3ea05db2540 Germany
919307d7-d6a1-4434-89eb-f8f18f607211 Croatia
cc802dfa-0019-40e3-b63b-909338aacc7f Czech Republic
3fd922df-49c8-4629-942f-1424b724d3d6 Poland
fcf12145-12f8-489d-a1a2-5d2f5cec55bb Netherlands
b5ce3e0b-1e9a-4aa0-bf4a-de0568d473b2 Netherlands
bd70af9c-c0f3-4891-9472-e1c6ef509af2 Estonia
63900ef9-165f-457b-ac78-dafa3ba146d1 Portugal
c8c90e9d-7c70-4379-96fd-a9ae6e6f1300 Germany
d0900ff7-a757-4fae-a881-a5ea25351c51 Germany
9b07e73f-14d1-4af1-9110-b8729f7402a2 France
1ad62dc8-d90d-4210-b193-abc6073a67d1 Netherlands
4b23fb89-fe2c-4410-bb42-7289f5302151 Spain
c9ce231f-a540-402b-914b-56397cad868a Netherlands
3a1436a8-4a07-462c-8f47-ffbf4c6edb63 Bulgaria
4978c3e4-b48b-4753-98bb-afdbf6490a07 Sweden
5fc59b9e-999c-48b4-a1e4-ec0f65261b4f Poland
7fbd870b-b6ac-4dbd-96ee-efc6241fb2dd France
Environmental
Ordering
3641396
4380323
8056221006262
1 piece
85389099
Dimensions
140 mm
205 mm
103.5 mm
3.425 kg
Container Information
box 1 piece
248 mm
240 mm
285 mm
3.8 kg
8056221006262
Additional Information
SACE Tmax XT
Moulded Case Circuit Breaker
Breaking Part
F
Technical
7000 cycle
60 cycles per hour
7000 cycle
60 cycles per hour
20000 cycle
120 cycles per hour
20000 cycle
120 cycles per hour
3P
1 piece
8 kV
1000 V
690 V AC
750 V DC
690 V AC
750 V DC
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 2 Poles in Series 25 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(250 V DC) 2 Poles in Series 25 kA
5 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 2 Poles in Series 25 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(250 V DC) 2 Poles in Series 25 kA
400 A
N
IEC60947-2
XT5
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
3721bd69-dcbe-4861-9a1d-72930cf01598 Italy
a17e4102-a861-4818-b1bf-bfecf018e641 Croatia
81409ab7-e8a3-47be-8f96-48523083fd82 Germany
a5df2f66-94ad-4a4f-8c2a-22bd7340c14f Portugal
26348fb7-b38f-464c-a16e-2b6064892278 Finland
bd778c27-61e4-474c-9239-cd5a73df48c5 France
37e9b6f2-a639-4922-8609-55cc465f7c25 Germany
55e9fc19-22fa-41ad-aadd-7a344084395c Norway
1ef333ef-43f6-4265-9cd3-57fd86c1ac99 Greece
c138137a-24ef-4357-9368-8391b964c17b France
e30fe312-aa13-4428-a1d8-a11d9f53f6ee Hungary
bd27dce2-8b39-4e71-84d1-2181da47e94b Germany
57ab4350-af5b-4342-8e04-584becd73e12 Germany
57c1616a-f855-4d9f-8710-1982732dcc90 Netherlands
a774e7dc-5a5f-4774-9a2c-7963030d8277 Sweden
9b1b2bb9-d1b6-43b0-9046-c35ae060f972 Bulgaria
012d9de2-2d91-4fcc-a0a2-31ba5de7a538 Czech Republic
a5df2f66-94ad-4a4f-8c2a-22bd7340c14f Portugal
c200c519-c6cf-404b-af1c-20190ea2fb17 Poland
a2aeefc2-d514-4490-982c-d59357e64956 Poland
57c1616a-f855-4d9f-8710-1982732dcc90 Netherlands
a5814e18-2069-4a2a-ac11-1d5e8283ea8b Belgium
1ef333ef-43f6-4265-9cd3-57fd86c1ac99 Greece
90d581b6-db70-4b61-91e6-32f85c1729b3 Spain
a5814e18-2069-4a2a-ac11-1d5e8283ea8b Belgium
ca8de7b2-ab44-4560-b7c7-8d398409109c Hungary
54f5c68b-2981-4a6a-a3c6-3c7e90992a95 Estonia
90d581b6-db70-4b61-91e6-32f85c1729b3 Spain
54f5c68b-2981-4a6a-a3c6-3c7e90992a95 Estonia
c200c519-c6cf-404b-af1c-20190ea2fb17 Poland
e30fe312-aa13-4428-a1d8-a11d9f53f6ee Hungary
57ab4350-af5b-4342-8e04-584becd73e12 Germany
c138137a-24ef-4357-9368-8391b964c17b France
bd27dce2-8b39-4e71-84d1-2181da47e94b Germany
a774e7dc-5a5f-4774-9a2c-7963030d8277 Sweden
bd778c27-61e4-474c-9239-cd5a73df48c5 France
a7919ca3-0f87-46ca-b0e0-eb0557f7fc75 Sweden
88f6e268-04e5-49ad-b05f-383d7f64bdf7 Poland
b8dc7e6b-845c-472c-ac91-54b44c39ef48 Germany
5b4bac4d-8af4-4d58-bb2b-3b5673959c86 Belgium
a17e4102-a861-4818-b1bf-bfecf018e641 Croatia
ca8de7b2-ab44-4560-b7c7-8d398409109c Hungary
6f3ae06e-348a-4000-b1be-9fd5b808e644 Denmark
37e9b6f2-a639-4922-8609-55cc465f7c25 Germany
88f6e268-04e5-49ad-b05f-383d7f64bdf7 Poland
012d9de2-2d91-4fcc-a0a2-31ba5de7a538 Czech Republic
a2aeefc2-d514-4490-982c-d59357e64956 Poland
a7919ca3-0f87-46ca-b0e0-eb0557f7fc75 Sweden
55e9fc19-22fa-41ad-aadd-7a344084395c Norway
b8dc7e6b-845c-472c-ac91-54b44c39ef48 Germany
5b4bac4d-8af4-4d58-bb2b-3b5673959c86 Belgium
6f3ae06e-348a-4000-b1be-9fd5b808e644 Denmark
9b1b2bb9-d1b6-43b0-9046-c35ae060f972 Bulgaria
81409ab7-e8a3-47be-8f96-48523083fd82 Germany
26348fb7-b38f-464c-a16e-2b6064892278 Finland
a17e4102-a861-4818-b1bf-bfecf018e641 Croatia
81409ab7-e8a3-47be-8f96-48523083fd82 Germany
a5df2f66-94ad-4a4f-8c2a-22bd7340c14f Portugal
26348fb7-b38f-464c-a16e-2b6064892278 Finland
bd778c27-61e4-474c-9239-cd5a73df48c5 France
37e9b6f2-a639-4922-8609-55cc465f7c25 Germany
55e9fc19-22fa-41ad-aadd-7a344084395c Norway
1ef333ef-43f6-4265-9cd3-57fd86c1ac99 Greece
c138137a-24ef-4357-9368-8391b964c17b France
e30fe312-aa13-4428-a1d8-a11d9f53f6ee Hungary
Environmental
Ordering
Z2HQEGAQ200A000000XX
8015644761509
1 piece
85362090
Dimensions
317 mm
425 mm
383 mm
48 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
53 kg
8015644761509
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
113 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
100 %
for 1 s 85 kA
for 3 s 66 kA
for 1 s 85 kA
for 3 s 66 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
1000 A
690 V
Ekip G Hi-Touch LSIG
EL
H
IEC
E2.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644645908
1 piece
85389099
Dimensions
278 mm
343 mm
251 mm
18 kg
Container Information
1 piece
19.5 kg
8015644609139
Additional Information
Accessories for Tmax T
Accessory
Fixed Part
W
Technical
3P
690 V AC
1600 A
IEC
T7-X1
Withdrawable Circuit-Breakers
Rear flat Horizontal
Front Extended
Withdrawable Circuit-Breakers
Rear flat Horizontal
Front Extended
Certificates and Declarations
External Classifications and Standards
EC002043 - Chassis part power circuit breaker
EC002043 - Chassis part power circuit breaker
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370422


Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644572723
1 piece
85362090
Dimensions
386 mm
418 mm
302 mm
56 kg
Container Information
1 piece
515 mm
600 mm
615 mm
68 kg
8015644572723
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
180 W
2000 A
12 kV
1000 V
2000 A
690 V AC
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
2000 A
690 V
PR122/P-LSI
EL
N
IEC
E2
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KA2S2
8015644691325
1 piece
85389099
Dimensions
0.109 kg
Container Information
1 piece
28.6 mm
136 mm
107 mm
0.115 kg
8015644691325
Additional Information
Accessories for FORMULA
Accessory
ACC
A1, A2
Technical
Loose or configurable
AC/DC
220 ... 240 V AC
220 ... 250 V DC
220 ... 240 V AC
220 ... 250 V DC
IEC
Certificates and Declarations
External Classifications and Standards
EC002483 - Switch spool for power circuit breaker
EC002483 - Switch spool for power circuit breaker
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370421

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT2HE3080MFF000XXX
4379390
8015644016746
1 piece
85362090
Dimensions
90 mm
130 mm
82.5 mm
1.1 kg
Container Information
box 1 piece
131 mm
212 mm
147 mm
1.2 kg
8015644016746
Additional Information
Motor Protection
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 32.5..100 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 5.8 W
80 A
50 / 60 Hz
8 kV
480…1120 A
1000 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
160 A
690 V
Main Circuit M6
MA
M
H
IEC60947-2
XT2
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Q
39121616
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTCAUP24W
4381128
8015644003593
1 piece
85389099
Dimensions
0.03 kg
Container Information
box 1 piece
105 mm
55 mm
135 mm
0.03 kg
8015644003593
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT2, XT4
SACE Tmax XT
Technical
Loose or configurable
1
1 piece
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC000041 - Auxiliary contact block
EC000041 - Auxiliary contact block
4743 >> Auxiliary contact block
Q
39121522
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371302

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
08ff2976-7071-4351-a588-0d80023d1004 Italy
e9b9519b-dbd8-476b-8303-56c8db7fdbde Belgium
224822d3-c356-41eb-80e0-f3ebfd397c56 Belgium
c880df6e-9c91-47c7-8ca1-684f89227e42 Norway
875a1a1a-69c0-464d-8c04-cca40e29f37b Bulgaria
42bfb2a3-b9d2-47ec-ba45-4d6d9b931564 Germany
73ecc6ad-08e8-4fcd-8661-818b208d30fc Denmark
dd395d2a-a82f-48b5-9853-853a15232df3 Germany
6b1b0b20-2d30-473f-a7fe-628262048583 Finland
82ad7c3a-d9d1-4ca1-8762-93c2731da8d1 Sweden
c0e4d13a-1905-404a-9a56-a1177afadb38 Croatia
224822d3-c356-41eb-80e0-f3ebfd397c56 Belgium
6b1b0b20-2d30-473f-a7fe-628262048583 Finland
aecae8c6-8b9a-4a4d-8a41-2e6264acc5bf Germany
42bfb2a3-b9d2-47ec-ba45-4d6d9b931564 Germany
aecae8c6-8b9a-4a4d-8a41-2e6264acc5bf Germany
dd395d2a-a82f-48b5-9853-853a15232df3 Germany
65233418-01c3-4da2-a713-1ee2efe6ce7a Poland
73ecc6ad-08e8-4fcd-8661-818b208d30fc Denmark
bab078eb-debf-4a97-af0f-b8e2b8ca1929 Poland
094adfb3-ad17-4539-8e3b-467d9e88edd9 Greece
79bf19f2-0e86-47b1-9702-04855a94d5eb Poland
bab078eb-debf-4a97-af0f-b8e2b8ca1929 Poland
95928cc3-1b5d-4486-8964-f96dadeffd51 Netherlands
421fd9ec-82e9-4c9a-9df9-c70e5119a743 France
c880df6e-9c91-47c7-8ca1-684f89227e42 Norway
2cfeb22a-c30b-4a91-b428-fcf8b9ed7f81 Portugal
646ccdee-18b6-402d-a990-2e0db059cb6f Czech Republic
1ac2e415-bd94-4b74-b06d-361f0feab7c9 Germany
4ca6942d-9c52-4ca6-9f2f-bdb420140e49 Sweden
c0e4d13a-1905-404a-9a56-a1177afadb38 Croatia
a813761e-b4d6-4134-bb85-2116075d442d Hungary
875a1a1a-69c0-464d-8c04-cca40e29f37b Bulgaria
70cf80a1-d383-4cdd-a437-6731e806825f Germany
88a58854-4650-432f-bbc4-15805dd3f832 Spain
88770b70-7971-4034-b477-28cff9700460 Hungary
e9b9519b-dbd8-476b-8303-56c8db7fdbde Belgium
2cfeb22a-c30b-4a91-b428-fcf8b9ed7f81 Portugal
65233418-01c3-4da2-a713-1ee2efe6ce7a Poland
421fd9ec-82e9-4c9a-9df9-c70e5119a743 France
4ca6942d-9c52-4ca6-9f2f-bdb420140e49 Sweden
1ac2e415-bd94-4b74-b06d-361f0feab7c9 Germany
70cf80a1-d383-4cdd-a437-6731e806825f Germany
1677dee4-294d-4d46-84ea-49fa049cfa02 France
646ccdee-18b6-402d-a990-2e0db059cb6f Czech Republic
a813761e-b4d6-4134-bb85-2116075d442d Hungary
094adfb3-ad17-4539-8e3b-467d9e88edd9 Greece
1677dee4-294d-4d46-84ea-49fa049cfa02 France
a15af9ee-f48e-4ac9-8158-bfab7ee304c1 Estonia
79bf19f2-0e86-47b1-9702-04855a94d5eb Poland
88770b70-7971-4034-b477-28cff9700460 Hungary
82ad7c3a-d9d1-4ca1-8762-93c2731da8d1 Sweden
95928cc3-1b5d-4486-8964-f96dadeffd51 Netherlands
a15af9ee-f48e-4ac9-8158-bfab7ee304c1 Estonia
88a58854-4650-432f-bbc4-15805dd3f832 Spain
e9b9519b-dbd8-476b-8303-56c8db7fdbde Belgium
224822d3-c356-41eb-80e0-f3ebfd397c56 Belgium
c880df6e-9c91-47c7-8ca1-684f89227e42 Norway
875a1a1a-69c0-464d-8c04-cca40e29f37b Bulgaria
42bfb2a3-b9d2-47ec-ba45-4d6d9b931564 Germany
73ecc6ad-08e8-4fcd-8661-818b208d30fc Denmark
dd395d2a-a82f-48b5-9853-853a15232df3 Germany
6b1b0b20-2d30-473f-a7fe-628262048583 Finland
82ad7c3a-d9d1-4ca1-8762-93c2731da8d1 Sweden
c0e4d13a-1905-404a-9a56-a1177afadb38 Croatia
Environmental
Ordering
Z1NQEGBB000A000000XX
8015644746520
1 piece
85362090
Dimensions
210 mm
296 mm
183 mm
14 kg
Container Information
box 1 piece
270 mm
350 mm
330 mm
16 kg
8015644746520
Additional Information
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
78 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
100 %
for 1 s 50 kA
for 3 s 30 kA
for 1 s 50 kA
for 3 s 30 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
1000 A
690 V
Main Circuit M10
Ekip Dip LSI
EL
N
IEC
E1.2
Yes, 690V
Front
Bolt
45 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
dbabcc4e-b0f5-4e1e-8d2b-e12e6cf40099 Italy
57a95767-a84f-4447-a882-43d3203428bb Germany
83cb26e6-ac2e-4762-a629-b7a8c219c7bf Sweden
2b53e6af-7119-45d4-861f-23b74399fe45 Denmark
77d890f8-44d0-4e1e-b973-483bcf1aab15 Germany
6f0c70b0-859a-423d-ab53-9615b55fb7e3 Germany
24fca232-6c76-4725-828b-c278de6607e9 Poland
b1939112-a908-4bb2-a38b-7b63855ee298 Belgium
52e11229-8da6-47b0-a026-5a4e2dda6cf8 Croatia
83f097f3-8b26-4468-900a-8c3e5122e868 Poland
77d890f8-44d0-4e1e-b973-483bcf1aab15 Germany
9e01a11f-0eed-4ecb-80b7-dec0a6383d8b Germany
2b53e6af-7119-45d4-861f-23b74399fe45 Denmark
2632476e-bcb4-4802-9ded-14d47c9d7472 Poland
be050563-9707-434d-9fea-4a4041fa37d3 Finland
9e01a11f-0eed-4ecb-80b7-dec0a6383d8b Germany
9b17a460-b176-4670-9613-9dc646a0bc19 Norway
9814d24a-bd56-4ea4-bcb4-ee1a4870b347 Portugal
83f097f3-8b26-4468-900a-8c3e5122e868 Poland
4819aa01-2009-4f63-8ced-9c5eed65e085 Belgium
ca4c8b75-dd4b-4287-a6d5-9d32e8136623 Netherlands
24fca232-6c76-4725-828b-c278de6607e9 Poland
52e11229-8da6-47b0-a026-5a4e2dda6cf8 Croatia
6c29752f-2cc5-499b-a5cb-8e57bad85ea7 Hungary
83cb26e6-ac2e-4762-a629-b7a8c219c7bf Sweden
6f0c70b0-859a-423d-ab53-9615b55fb7e3 Germany
ba863063-bc72-4170-a313-95db9d2a5733 Bulgaria
b0a94c2b-c1a6-49b4-8e4b-f25af11aa402 Czech Republic
9b17a460-b176-4670-9613-9dc646a0bc19 Norway
57a95767-a84f-4447-a882-43d3203428bb Germany
b0a94c2b-c1a6-49b4-8e4b-f25af11aa402 Czech Republic
9814d24a-bd56-4ea4-bcb4-ee1a4870b347 Portugal
ad6a82f5-2b08-4c7f-a7ac-ebaf8cf322cc France
be050563-9707-434d-9fea-4a4041fa37d3 Finland
b1939112-a908-4bb2-a38b-7b63855ee298 Belgium
3a4cee54-d479-4413-9d77-825fd09d1e71 Germany
c5c0a50b-31e6-4150-b2c9-1d206289bde5 Estonia
6c29752f-2cc5-499b-a5cb-8e57bad85ea7 Hungary
79871c02-6334-4976-8858-db4689b8d984 Spain
4819aa01-2009-4f63-8ced-9c5eed65e085 Belgium
a2127277-deb2-4470-8caf-cf2204632f79 Hungary
a07caea4-a7a3-48c8-86f9-639750829c37 France
ca22ba67-03dc-4d40-8604-ef5ff9d44629 Sweden
82ba7a2f-f987-4bc9-9d1d-7a56579e8933 Greece
ba863063-bc72-4170-a313-95db9d2a5733 Bulgaria
2632476e-bcb4-4802-9ded-14d47c9d7472 Poland
ca22ba67-03dc-4d40-8604-ef5ff9d44629 Sweden
ad6a82f5-2b08-4c7f-a7ac-ebaf8cf322cc France
3a4cee54-d479-4413-9d77-825fd09d1e71 Germany
a07caea4-a7a3-48c8-86f9-639750829c37 France
c5c0a50b-31e6-4150-b2c9-1d206289bde5 Estonia
a2127277-deb2-4470-8caf-cf2204632f79 Hungary
ca4c8b75-dd4b-4287-a6d5-9d32e8136623 Netherlands
79871c02-6334-4976-8858-db4689b8d984 Spain
82ba7a2f-f987-4bc9-9d1d-7a56579e8933 Greece
57a95767-a84f-4447-a882-43d3203428bb Germany
83cb26e6-ac2e-4762-a629-b7a8c219c7bf Sweden
2b53e6af-7119-45d4-861f-23b74399fe45 Denmark
77d890f8-44d0-4e1e-b973-483bcf1aab15 Germany
6f0c70b0-859a-423d-ab53-9615b55fb7e3 Germany
24fca232-6c76-4725-828b-c278de6607e9 Poland
b1939112-a908-4bb2-a38b-7b63855ee298 Belgium
52e11229-8da6-47b0-a026-5a4e2dda6cf8 Croatia
83f097f3-8b26-4468-900a-8c3e5122e868 Poland
77d890f8-44d0-4e1e-b973-483bcf1aab15 Germany
Environmental
Ordering
Z1BQEGBB000A000000XX
8015644746322
1 piece
85362090
Dimensions
210 mm
296 mm
183 mm
14 kg
Container Information
box 1 piece
270 mm
350 mm
330 mm
16 kg
8015644746322
Additional Information
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
78 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
100 %
for 1 s 42 kA
for 3 s 24 kA
for 1 s 42 kA
for 3 s 24 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
1000 A
690 V
Main Circuit M10
Ekip Dip LSI
EL
B
IEC
E1.2
Yes, 690V
Front
Bolt
45 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KA1HTC-3
8015644000905
1 piece
85389099
Dimensions
0.129 kg
Container Information
1 piece
0.136 kg
8015644000905
Additional Information
Accessories for FORMULA
Accessory
ACC
A1
Technical
Loose or configurable
3P
IEC
Certificates and Declarations
External Classifications and Standards
EC002268 - Cover cap for rail terminal bar
EC002268 - Cover cap for rail terminal bar
5219 >> Switch part or accessory
Q
39122221
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27400635

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644517908
1 piece
85389099
Dimensions
0.04 kg
Container Information
1 piece
110 mm
60 mm
140 mm
0.077 kg
8015644517908
Additional Information
Accessories for Tmax T
Accessory
Accessory
T1, T2, T3, T4, T5, T6
SACE Tmax T
Technical
Loose or configurable
T1-T2-T3
3
IEC
Certificates and Declarations
External Classifications and Standards
EC000041 - Auxiliary contact block
EC000041 - Auxiliary contact block
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371302

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644573744
1 piece
85362090
Dimensions
324 mm
461 mm
396.5 mm
49 kg
Container Information
1 piece
515 mm
600 mm
515 mm
59 kg
8015644573744
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
330 W
2000 A
12 kV
1000 V
2000 A
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
for 1 s 65 kA
for 3 s 50 kA
for 1 s 65 kA
for 3 s 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
2000 A
690 V
PR121/P-LSIG
EL
S
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2SQEGBK200A000000XX
8015644747893
1 piece
85362090
Dimensions
276 mm
371 mm
270 mm
41 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
46 kg
8015644747893
Additional Information
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
53 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
1000 A
690 V
Main Circuit M12
Ekip Hi-Touch LSIG
EL
S
IEC
E2.2
Yes, 690V
Rear flat Horizontal
Bolt
70 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
Z2HQ00A00000000000XX
8015644773397
1 piece
85362090
Dimensions
317 mm
425 mm
383 mm
48 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
53 kg
8015644773397
Additional Information
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
113 W
1000 A
12 kV
AC 1000 V
690 V AC
for 1 s 85 kA
for 3 s 66 kA
for 1 s 85 kA
for 3 s 66 kA
1000 A
690 V
H
IEC
E2.2
Certificates and Declarations
External Classifications and Standards
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
5293 >> Switch disconnector
Q
39122233
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371403

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.3 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
Z4NV00A00000000000XX
8015644773526
1 piece
85362090
Dimensions
425 mm
425 mm
383 mm
60 kg
Container Information
box 1 piece
515 mm
610 mm
615 mm
67 kg
8015644773526
Additional Information
Technical
AC
Ue =< 440 V 7000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Ue =< 440 V 7000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
743 W
3200 A
12 kV
AC 1000 V
690 V AC
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
3200 A
690 V
N
IEC
E4.2
Certificates and Declarations
External Classifications and Standards
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
5293 >> Switch disconnector
Q
39122233
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371403

Environmental
Ordering
8015644137816
1 piece
85389099
Dimensions
110 mm
60 mm
0.14 m
0.13 kg
Container Information
1 piece
60 mm
110 mm
0.13 kg
8015644137816
Additional Information
Spare Parts
Accessory
S3
S4
S5
S3
S4
S5
Isomax
Technical
S3-S4-S5
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

ABB
1SDA067410R1 ABB - XT1C 160 TMD 160-1600 4p F F InN=100%
Sale price
2,588.00 kr
Only 10 units leftABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
b3a6e17d-8853-4b28-96d6-13ac4a29e0af Italy
e4ed785f-3095-4d3c-b8a8-3d1f751265d4 Germany
64316cdd-7ef1-48e6-8210-8cd7634e6115 Poland
ddf5c063-a647-4dfc-8837-7781de6c5035 France
0cbd6a1f-8fbe-4ce7-b86c-d905abce4e78 Sweden
46fc09a7-c01c-4a86-8c86-1e15db9ddddd Greece
4d2c1e03-1026-4a24-a714-ba61c1b1aeee Portugal
573806cd-5dc7-4a36-b2c9-3af14e648b64 Bulgaria
f2cec4b9-6375-4b09-a143-cbfcc2ccd71e Sweden
74afcc10-c8eb-4b64-826f-c6e09a31053c Norway
87552666-a6c6-4548-a8e5-40917c1b57dc Finland
249250e9-16fb-4336-840d-3ddc106220b0 Netherlands
4a1567df-fca8-4001-a5f2-636daa499d03 Germany
3bd810fd-8f98-4a28-a7a5-d48686d3b52f Denmark
1089ac8c-be20-4529-88f1-e56272ee5745 Germany
9f570cc2-9e42-4bc1-a196-c64493922610 Croatia
9ca7775f-04be-4da1-95fd-8425bed150ad Czech Republic
d9af99e0-6e58-4be1-b105-7d6331de21e1 Poland
cc8e596f-2606-4b6a-9f71-e1624c107c2a Netherlands
02115938-fed4-4469-bc5b-6f21ac2250c7 Netherlands
56e9af4f-b0db-42d7-8296-ae9b206e45bd Estonia
4d2c1e03-1026-4a24-a714-ba61c1b1aeee Portugal
4e4b3496-d89c-46fc-b3d7-7c3014c9ae11 Germany
04bf539e-4478-4a6d-b752-29b131601c1a Germany
5002da91-49cf-4761-8f5b-0ab42e5e7bdc France
12f6c623-68ef-4936-b8a9-228e974c7950 Netherlands
11f40390-af61-4605-91a7-7be6ad1a47a4 Spain
5e4194ae-657e-453f-bdf9-c3df7d1918b0 Netherlands
46fc09a7-c01c-4a86-8c86-1e15db9ddddd Greece
573806cd-5dc7-4a36-b2c9-3af14e648b64 Bulgaria
f2cec4b9-6375-4b09-a143-cbfcc2ccd71e Sweden
5e4194ae-657e-453f-bdf9-c3df7d1918b0 Netherlands
64316cdd-7ef1-48e6-8210-8cd7634e6115 Poland
ddf5c063-a647-4dfc-8837-7781de6c5035 France
0cbd6a1f-8fbe-4ce7-b86c-d905abce4e78 Sweden
4e4b3496-d89c-46fc-b3d7-7c3014c9ae11 Germany
04bf539e-4478-4a6d-b752-29b131601c1a Germany
5002da91-49cf-4761-8f5b-0ab42e5e7bdc France
12f6c623-68ef-4936-b8a9-228e974c7950 Netherlands
11f40390-af61-4605-91a7-7be6ad1a47a4 Spain
ff3838eb-1489-4dd2-b38a-8d6e6fb45332 Poland
74afcc10-c8eb-4b64-826f-c6e09a31053c Norway
87552666-a6c6-4548-a8e5-40917c1b57dc Finland
249250e9-16fb-4336-840d-3ddc106220b0 Netherlands
4a1567df-fca8-4001-a5f2-636daa499d03 Germany
3bd810fd-8f98-4a28-a7a5-d48686d3b52f Denmark
1089ac8c-be20-4529-88f1-e56272ee5745 Germany
9f570cc2-9e42-4bc1-a196-c64493922610 Croatia
9ca7775f-04be-4da1-95fd-8425bed150ad Czech Republic
d9af99e0-6e58-4be1-b105-7d6331de21e1 Poland
cc8e596f-2606-4b6a-9f71-e1624c107c2a Netherlands
02115938-fed4-4469-bc5b-6f21ac2250c7 Netherlands
56e9af4f-b0db-42d7-8296-ae9b206e45bd Estonia
ff3838eb-1489-4dd2-b38a-8d6e6fb45332 Poland
e4ed785f-3095-4d3c-b8a8-3d1f751265d4 Germany
64316cdd-7ef1-48e6-8210-8cd7634e6115 Poland
ddf5c063-a647-4dfc-8837-7781de6c5035 France
0cbd6a1f-8fbe-4ce7-b86c-d905abce4e78 Sweden
46fc09a7-c01c-4a86-8c86-1e15db9ddddd Greece
4d2c1e03-1026-4a24-a714-ba61c1b1aeee Portugal
573806cd-5dc7-4a36-b2c9-3af14e648b64 Bulgaria
f2cec4b9-6375-4b09-a143-cbfcc2ccd71e Sweden
74afcc10-c8eb-4b64-826f-c6e09a31053c Norway
87552666-a6c6-4548-a8e5-40917c1b57dc Finland
Environmental
Ordering
XT1CE4160AFF000XXX
4309719
8015644013042
1 piece
85362090
Dimensions
101.6 mm
130 mm
70 mm
1.4 kg
Container Information
box 1 piece
128 mm
135 mm
143 mm
1.454 kg
8015644013042
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 45.5 ... 80 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
4P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 15 W
160 A
50 / 60 Hz
8 kV
1600 A
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
160 A
690 V
Main Circuit M6
TMD
TM
112...160 A
C
IEC60947-2
XT1
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409
