
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644596460
1 piece
85362090
Dimensions
404 mm
418 mm
302 mm
60 kg
Container Information
8015644596460
Additional Information
SACE Emax
Air Circuit Breaker
CB
F
Technical
AC
Ue =< 508 V 8000 cycle
Ue = 508 ... 635 V 8000 cycle
30 cycles per hour
Ue =< 508 V 8000 cycle
Ue = 508 ... 635 V 8000 cycle
30 cycles per hour
15000 cycle
30 cycles per hour
15000 cycle
30 cycles per hour
3P
at Rated Operating Conditions per Pole 130 W
2000 A
2000 A
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
2000 A
600 V
PR122/P-LSI
EL
N
UL 1066
E3
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Technical UL/CSA
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
(240 V AC) 65 kA
(480 V AC) 50 kA
(600 V AC) 50 kA
Certificates and Declarations
External Classifications and Standards
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT2NE3032MFF000XXX
4309681
8015644009564
1 piece
85362090
Dimensions
90 mm
130 mm
82.5 mm
1.4 kg
Container Information
box 1 piece
130 mm
208 mm
145 mm
1.664 kg
8015644009564
Additional Information
Motor Protection
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 32.5..100 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 2.57 W
32 A
50 / 60 Hz
8 kV
192…448 A
1000 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
160 A
690 V
Main Circuit M6
MA
M
N
IEC60947-2
XT2
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Material Compliance
Environmental
Ordering
Dimensions
76 mm
130 mm
70 mm
1 kg
Container Information
1 piece
128 mm
135 mm
143 mm
1.11 kg
8015644513344
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
CB
T1
Moulded Case Circuit Breakers
F
Technical
8000 cycle
120 cycles per hour
8000 cycle
120 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
3P
at Rated Operating Conditions per Pole 7 W
100 A
8 kV
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
160 A
TMD
TM
N
IEC 60947
T1
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
3000 V
3000 V
Certificates and Declarations
External Classifications and Standards
Q
39121100

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644576769
1 piece
85362090
Dimensions
404 mm
418 mm
302 mm
60 kg
Container Information
1 piece
515 mm
600 mm
615 mm
72 kg
8015644576769
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 12000 cycle
20 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 12000 cycle
20 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
22 W
800 A
12 kV
1000 V
800 A
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
for 1 s 75 kA
for 3 s 65 kA
for 1 s 75 kA
for 3 s 65 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
800 A
690 V
PR121/P-LI
EL
H
IEC
E3
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
4376645
8015644383213
1 piece
85389099
Dimensions
1 kg
Container Information
1 piece
1.688 kg
8015644383213
Additional Information
Accessories for Emax
Accessory
Accessory
E1, E2, E3, E4, E6, T8
SACE Emax, SACE Tmax T
Technical
Loose or configurable
AC/DC
24 ... 30 V AC/DC
IEC
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT3ECUALX2-8PC
8015644010997
1 piece
85389099
Dimensions
1.33 kg
Container Information
box 1 piece
155 mm
185 mm
160 mm
1.47 kg
8015644010997
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT3
SACE Tmax XT
Technical
Loose or configurable
4P
1 piece
IEC60947-2
Front for Copper-Aluminium Cables
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644653941
1 piece
85362090
Dimensions
280 mm
268 mm
154 mm
12.5 kg
Container Information
1 piece
360 mm
350 mm
360 mm
14 kg
8015644653941
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
T7
Moulded Case Circuit Breakers
F
Technical
3000 cycle
60 cycles per hour
3000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
4P
at Rated Operating Conditions per Pole 50 W
1000 A
8 kV
1000 V
690 V AC
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 150 kA
(400 V AC) 150 kA
(415 V AC) 150 kA
(440 V AC) 130 kA
(500 V AC) 100 kA
(690 V AC) 45 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 150 kA
(400 V AC) 150 kA
(415 V AC) 150 kA
(440 V AC) 130 kA
(500 V AC) 100 kA
(690 V AC) 45 kA
for 1 s 15 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 150 kA
(400 V AC) 150 kA
(415 V AC) 150 kA
(440 V AC) 130 kA
(500 V AC) 100 kA
(690 V AC) 60 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 150 kA
(400 V AC) 150 kA
(415 V AC) 150 kA
(440 V AC) 130 kA
(500 V AC) 100 kA
(690 V AC) 60 kA
1000 A
PR332/P LI
EL
V
IEC
T7
Fixed Circuit-Breakers
Front
Fixed Circuit-Breakers
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
b05eee46-ac7c-4986-b103-4456de0f7bf3 Italy
a977f2ff-a1c8-4123-8a12-edf8e740a809 Germany
b50cb66e-0fa0-4466-beea-a3d96200a766 Netherlands
7655a3fc-ee55-46bb-9a8c-a91a6d7db03e Spain
8ec5fc74-95a6-45be-bdfc-32c11407fa92 Netherlands
b3e66b09-8949-425f-b245-df78b5fead9e Germany
25def33a-10a4-4e45-9ccc-a96d65b5c9e1 Sweden
355d8eea-bdc0-4103-80d0-dde4e8fd538a France
a1c0933b-8ce1-486f-b55c-b83739d17749 Poland
52808cb7-53d9-4567-b91a-dcbd1efd3ac7 Sweden
0cae59a1-9a0d-4154-9401-e923f4215204 Bulgaria
de7cd5be-ee1a-4a1a-98de-0c8ecf87dc92 Portugal
09d8a2ed-08d2-4791-84f8-84ae2dc70197 Greece
a9a82c36-6b93-471c-b403-1b2d60d25421 Estonia
ef35ae13-5b14-4367-ae05-c480d4a4fb1c Poland
31a1fa2a-9be6-4c5b-8152-8d9c343cc857 Netherlands
2757738b-3e1d-4110-ae81-0e76cd8e6481 Netherlands
230d99e2-75de-4436-bdeb-94b289c97d2d Czech Republic
003d886f-39cc-435e-8485-5dab2fac3fe1 Croatia
b7284998-9321-4095-ad97-d508f687d998 Germany
5208c008-66a2-4f36-a1e2-a0561adf6c54 Denmark
4cd82cce-1d3e-4e20-8214-9aacdcbd57c2 Germany
51fc47bb-bef0-4864-92c1-3f36cc25d242 France
f9db9213-cda5-47cb-9dc6-ae61d4cee6c9 Germany
ad74c881-87ff-4c49-b26b-e2e55e42ae7c Poland
2d5ee082-b7fa-4a5b-a55e-2700ca49848d Netherlands
94ab850b-ee6d-4786-8c9d-1feaf95bd94b Finland
66546424-47f0-4ae8-a814-ead92287e534 Norway
a977f2ff-a1c8-4123-8a12-edf8e740a809 Germany
b50cb66e-0fa0-4466-beea-a3d96200a766 Netherlands
7655a3fc-ee55-46bb-9a8c-a91a6d7db03e Spain
8ec5fc74-95a6-45be-bdfc-32c11407fa92 Netherlands
b3e66b09-8949-425f-b245-df78b5fead9e Germany
25def33a-10a4-4e45-9ccc-a96d65b5c9e1 Sweden
355d8eea-bdc0-4103-80d0-dde4e8fd538a France
a1c0933b-8ce1-486f-b55c-b83739d17749 Poland
52808cb7-53d9-4567-b91a-dcbd1efd3ac7 Sweden
0cae59a1-9a0d-4154-9401-e923f4215204 Bulgaria
Environmental
Ordering
3655323
4383613
3180374
8015644554941
1 piece
85362090
Dimensions
140 mm
205 mm
103.5 mm
4.817 kg
Container Information
1 piece
248 mm
240 mm
285 mm
5.1 kg
8015644554941
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
T5
Moulded Case Circuit Breakers
F
Technical
5000 cycle
60 cycles per hour
5000 cycle
60 cycles per hour
20000 cycle
120 cycles per hour
20000 cycle
120 cycles per hour
3P
at Rated Operating Conditions per Pole 41 W
630 A
8 kV
1000 V
690 V AC
(220 V AC) 70 kA
(230 V AC) 70 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 30 kA
(500 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 30 kA
(500 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 30 kA
(500 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 30 kA
(500 V AC) 25 kA
(690 V AC) 20 kA
630 A
PR221DS-LS/I
EL
N
IEC
T5
Fixed Circuit-Breakers
Front
Fixed Circuit-Breakers
Front
3500 V
3500 V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644561277
1 piece
85389099
Dimensions
0.2 kg
Container Information
1 piece
0.2 kg
8015644561277
Additional Information
Accessories for Tmax T
Accessory
Accessory
T4
SACE Tmax T
Technical
Loose or configurable
4P
IEC
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT2HE3125BFF000XXX
3602495
4379300
8015644014995
1 piece
85362090
Dimensions
90 mm
130 mm
82.5 mm
1.4 kg
Container Information
box 1 piece
130 mm
208 mm
145 mm
1.649 kg
8015644014995
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 32.5..100 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 11.4 W
125 A
50 / 60 Hz
8 kV
625…1250 A
1000 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 30 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
160 A
690 V
Main Circuit M6
TMA
TM
87.5...125 A
H
IEC60947-2
XT2
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT2NE3003AFF000XXX
4309629
8015644009076
1 piece
85362090
Dimensions
90 mm
130 mm
82.5 mm
1.1 kg
Container Information
box 1 piece
131 mm
212 mm
147 mm
1.2 kg
8015644009076
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 32.5..100 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 2.76 W
3.2 A
50 / 60 Hz
8 kV
32 A
1000 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
160 A
690 V
Main Circuit M6
TMD
TM
2.24...3.2 A
N
IEC60947-2
XT2
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644654801
1 piece
85362090
Dimensions
210 mm
268 mm
154 mm
9.7 kg
Container Information
1 piece
280 mm
350 mm
360 mm
11.2 kg
8015644654801
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
T7
Moulded Case Circuit Breakers
F
Technical
2000 cycle
60 cycles per hour
2000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
3P
at Rated Operating Conditions per Pole 47 W
1250 A
8 kV
1000 V
690 V AC
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 64 kA
(690 V AC) 37.5 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 64 kA
(690 V AC) 37.5 kA
for 1 s 20 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(690 V AC) 50 kA
(220 V AC) 200 kA
(230 V AC) 200 kA
(380 V AC) 120 kA
(400 V AC) 120 kA
(415 V AC) 120 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(690 V AC) 50 kA
1250 A
PR232/P-LSI
EL
L
IEC
T7
Fixed Circuit-Breakers
Front
Fixed Circuit-Breakers
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2NTEKAC000A000000XX
8015644762339
1 piece
85362090
Dimensions
317 mm
425 mm
383 mm
48 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
53 kg
8015644762339
Additional Information
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
450 W
2000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
2000 A
690 V
Ekip Dip LSIG
EL
N
IEC
E2.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2NTEKAJ200A000000XX
8015644762384
1 piece
85362090
Dimensions
317 mm
425 mm
383 mm
48 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
53 kg
8015644762384
Additional Information
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
450 W
2000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
2000 A
690 V
Ekip Hi-Touch LSI
EL
N
IEC
E2.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409



ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Product Modularity
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT1NU3125AFF000XXX
8015644786250
1 piece
85362090
Dimensions
76.2 mm
130 mm
70 mm
1.1 kg
Container Information
box 1 piece
128 mm
135 mm
143 mm
1.1 kg
8015644786250
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
SACE Tmax XT
F
Technical
Busbar 45.5 ... 80 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 10.7 W
125 A
500 A
600Y/347 V AC
500 V DC
600Y/347 V AC
500 V DC
125 A
600Y/347 V
Main Circuit M6
TMF
TM
125 A
N
UL489
XT1
Front
Bolt
6 N·m
Technical UL/CSA
(240 V AC) 50 kA
(480 V AC) 25 kA
(600Y / 347 V AC) 18 kA
(250 V DC) 2 Poles in Series 35 kA
(500 V DC) 4 Poles in Series Kind 35 kA
(240 V AC) 50 kA
(480 V AC) 25 kA
(600Y / 347 V AC) 18 kA
(250 V DC) 2 Poles in Series 35 kA
(500 V DC) 4 Poles in Series Kind 35 kA
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4927 >> Molded case circuit breakers
Q
39121616
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KT7XWMK
8015644647018
1 piece
85389099
Dimensions
0.8 kg
Container Information
1 piece
145 mm
230 mm
300 mm
0.8 kg
8015644647018
Additional Information
Accessories for Tmax T
Accessory
Accessory
T7, X1
SACE Tmax T
SACE Emax
SACE Tmax T
SACE Emax
Technical
Loose or configurable
3P
IEC
Certificates and Declarations
External Classifications and Standards
EC002049 - Modification set for power circuit breaker
EC002049 - Modification set for power circuit breaker
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370402

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KE6TL9
4376640
8015644383169
1 piece
85389099
Dimensions
150 mm
60 mm
200 mm
0.263 kg
Container Information
box 1 piece
150 mm
60 mm
200 mm
0.263 kg
8015644383169
Additional Information
Accessories for Emax 2, Accessories for Tmax XT
Accessory
Accessory
XT7-XT7M, E1.2, E2.2, E4.2, E6.2, E1, E2, E3, E4, E6, X1, T7, T8
SACE Tmax XT, SACE Emax 2, SACE Emax, SACE Tmax T
Technical
Loose or configurable
AC/DC
1 piece
24 ... 30 V
IEC
Certificates and Declarations
External Classifications and Standards
EC002052 - Time delay under voltage coil
EC002052 - Time delay under voltage coil
4147 >> Time delay under voltage coil
Q
39121010
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370426

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT2WMP-3
3640808
4381526
8015644001940
1 piece
85389099
Dimensions
0.61 kg
Container Information
box 1 piece
250 mm
30 mm
300 mm
0.642 kg
8015644001940
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT2
SACE Tmax XT
W
Technical
Loose or configurable
3P
1 piece
160 A
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002049 - Modification set for power circuit breaker
EC002049 - Modification set for power circuit breaker
5219 >> Switch part or accessory
Q
39122221
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370402

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
020a4d48-292d-4633-99d6-f08c13ed9710 Italy
b49f8323-a674-4795-928f-6a503e725e20 Germany
3b3acbbf-44bd-4858-b260-94d88ac1cff7 France
2d39a1e9-2a48-4605-b010-ed80f6bb4248 Spain
5d2a0746-37f2-4cf8-ba28-a15e000a2c2a Hungary
c8643850-713e-4ab9-9f46-06744b4d8d29 Belgium
de11cc3a-5115-4d9b-86dc-3f9d5ece95e1 Czech Republic
9efc7b0d-3149-47a0-a0f5-ddfa88609209 Sweden
84103145-1d20-4931-b56e-aa45af9040a6 Croatia
6244cdb2-8edd-427b-85ff-b91164c9cfd6 Germany
b94a0cae-8dee-4464-866a-147ced5963ac Denmark
bfb2f107-7132-42e7-8588-81187600fced Germany
e589e10c-a51e-4b6c-8959-dc9523f1822c Germany
115f6159-724c-41c5-93e1-2a08139a93b6 Portugal
d26121c0-4d27-4a3b-a3b9-f3dd4d9f7d9f Poland
60674830-d847-4c8e-a83e-21328d626930 Poland
7aed2d11-93a4-4495-ae04-63f26b9fe440 Netherlands
65dcf0b4-8821-4cf5-89b7-22cfcf6f4b75 Sweden
526ff92d-35af-4819-8a1e-77d74d090cde Norway
bfb26ae3-b043-49a4-b967-a2c616f7525b Bulgaria
05460536-e526-48ce-9a70-18204249155b Greece
fcb67af1-20d7-42d9-95ac-705bcb77266d France
11b4c96d-e784-46ae-9b45-cfffdf87f368 Germany
eede1d9a-0841-4064-87c1-d814e8590696 Belgium
4db19b8e-20cc-4a1a-a879-e0cd29600f2f Estonia
05c09dd9-1798-4a25-8e5c-aad0df75cfd4 Finland
83dfe74c-cd2f-47fc-b8e1-bf2ff3f90db4 Hungary
0b27eb60-a466-41a2-8c9d-6aa3e6104293 Poland
b49f8323-a674-4795-928f-6a503e725e20 Germany
3b3acbbf-44bd-4858-b260-94d88ac1cff7 France
2d39a1e9-2a48-4605-b010-ed80f6bb4248 Spain
5d2a0746-37f2-4cf8-ba28-a15e000a2c2a Hungary
c8643850-713e-4ab9-9f46-06744b4d8d29 Belgium
de11cc3a-5115-4d9b-86dc-3f9d5ece95e1 Czech Republic
9efc7b0d-3149-47a0-a0f5-ddfa88609209 Sweden
84103145-1d20-4931-b56e-aa45af9040a6 Croatia
6244cdb2-8edd-427b-85ff-b91164c9cfd6 Germany
b94a0cae-8dee-4464-866a-147ced5963ac Denmark
Environmental
Ordering
XT1NU3100AFF000XXX
8015644786236
1 piece
85362090
Dimensions
76.2 mm
130 mm
70 mm
1.1 kg
Container Information
box 1 piece
128 mm
135 mm
143 mm
1.1 kg
8015644786236
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
SACE Tmax XT
F
Technical
Busbar 45.5 ... 80 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 7 W
100 A
1100 A
600Y/347 V AC
500 V DC
600Y/347 V AC
500 V DC
125 A
600Y/347 V
Main Circuit M6
TMF
TM
100 A
N
UL489
XT1
Front
Bolt
6 N·m
Technical UL/CSA
(240 V AC) 50 kA
(480 V AC) 25 kA
(600Y / 347 V AC) 18 kA
(250 V DC) 2 Poles in Series 35 kA
(500 V DC) 4 Poles in Series Kind 35 kA
(240 V AC) 50 kA
(480 V AC) 25 kA
(600Y / 347 V AC) 18 kA
(250 V DC) 2 Poles in Series 35 kA
(500 V DC) 4 Poles in Series Kind 35 kA
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4927 >> Molded case circuit breakers
Q
39121616
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTFYOCFPB
3642167
4381339
8015644070250
1 piece
85389099
Dimensions
0.17 kg
Container Information
box 1 piece
110 mm
60 mm
140 mm
0.2 kg
8015644070250
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT5
XT6
XT5
XT6
SACE Tamx XT
Technical
Loose or configurable
AC/DC
1 piece
24...60 V AC
24...60 V DC
24...60 V AC
24...60 V DC
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002483 - Switch spool for power circuit breaker
EC002483 - Switch spool for power circuit breaker
4879 >> Shunt release (for power circuit breaker)
39121601
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370421


