
Specifications
Model |
OP-87418 |
|||
Overview |
Tungsten electrode probe. It is light-grey in color. |
|||
Applicable product |
SJ-EL/SJ-EN |
|||
Material |
Tungsten |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-D5B |
|||
Type |
Motor power cable, Standard cable with electromagnetic brake |
|||
Length |
5 m 16.4' |
|||
Note |
for 200 W / 400 W motor |
|||

Specifications
Model |
SJ-H228A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2280 mm 89.76" *3 |
|||
No. ofelectrodes |
36 |
|||
Static elimination bar length |
2240 mm 88.19" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2350 g 82.89 oz |
||
*1 Measured under the following conditions. | ||||







Specifications
Model |
GL-VM22LP |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
22 |
|||
Total length |
880 mm 34.65" |
|||
Detection height |
840 mm 33.07" |
|||
Protection height |
925 mm 36.42" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.8 |
|
OFF→ON |
46.7 *3 |
|||
All blocked→ON |
53.2 *4 |
|||
With channel A or B |
ON→OFF |
12.7 |
||
OFF→ON |
61.3 *3 |
|||
All blocked→ON |
78.6 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
106 *5 |
||
Receiver |
119 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
51 *5 |
||
Receiver |
58 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
580 g 20.47 oz |
||
Receiver |
590 g 20.82 oz |
|||
Total |
1170 g 41.30 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||


Specifications
Model |
GL-S28SH |
|||
Type |
Slim type |
|||
Detection capability |
ø25 mm ø0.98" |
|||
Total length |
579.5 mm 22.81" |
|||
No. of beam |
28 |
|||
Detection height |
540mm 21.26" |
|||
Protection height |
586mm 23.07" |
|||
Beam axis spacing |
20 mm 0.79" |
|||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
|||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
7.4 *1 |
|
OFF→ON |
50.0 *1 *2 |
|||
All blocked→ON |
66.6 *1 *3 |
|||
Optical synchronization system (channel A or B) |
ON→OFF |
10.2 *1 |
||
OFF→ON |
54.0 *1 *2 |
|||
All blocked→ON |
77.5 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
|||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
|||
Control output (OSSD output) |
Output type |
2 transistor outputs |
||
Max. load current |
Max. 300 mA |
|||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 200 µA |
|||
Max. load capacitance |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
|||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
44*4 |
Receiver |
67*4 |
|||
When the center indicator is OFF |
Transmitter |
29*4 |
||
Receiver |
52*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (no condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Polyarylate |
||
Weight |
Transmitter |
215 g |
||
Receiver |
220 g |
|||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
CA-DQW12M |
|||
Type |
Multi-angle Light (Square) |
|||
LED color |
White |
|||
Power consumption |
19.9 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 310 g |
|||

Specifications
Model |
FT-S2 |
|||
Infrared transmissivity |
85% or more *1 |
|||
Material |
Cap: aluminum, |
|||
Note |
Sold separately |
|||
Weight |
Approx. 32 g |
|||
*1 Infrared transmissivity for wavelength of 8 to 14 μm. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
CZ-V22 |
|||
Output |
NPN output |
|||
Main unit/expansion unit |
Expansionunit (with outputcable) |
|||
Response time |
8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED) |
|||
Control output |
NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1 |
|||
Protection circuit |
Reverse-polarity protection, overcurrent protection, surge absorber |
|||
External calibration input |
No-voltage input, input time: 20 ms or more |
|||
External shift input | ||||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively) |
|||
Unit expansion |
Up to 3 units (4 units total including the main unit)*2 |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*3 |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing, cover: Polycarbonate |
|||
Weight |
Approx. 100 g |
|||
*1 20 mA max. when several units are connected. | ||||


Specifications
Model |
ER-08PC |
|||
Type |
Ultra-long distance shielded type Screw type M8 Connector (M8 3-pin) PNP output |
|||
Power supply cable length |
― *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
4.5 mm 0.18" ±10% *2 |
||
With distance switching (Mode 2) |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
20 Hz *3 *4 |
||
With distance switching (Mode 2) |
80 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
13.5 × 13.5 mm 0.53" × 0.53" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 20 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
SV2-C5A |
|||
Type |
Motor power cable, Standard |
|||
Length |
5 m 16.4' |
|||
Note |
for 50 W / 100 W motor |
|||

