Machine Vision Systems

5768 products

Showing 889 - 912 of 5768 products

Showing 889 - 912 of 5768 products
View
Keyence New Stock Image
Keyence GL-R79F Keyence
Sale price 16,273.00 kr
In stock, 12 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SV2-LA2 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SV2-LA2

Type

Communication Cable

Length

0.2 m 0.7'

keyence Stock Image
Keyence SV3-B150AS Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SV3-B150AS *1

General specifications

Applicable servo amplifier

SV3-150L2

Rated output

1.3k W

Rated torque

8.34 N·m *2

Instant maximum torque

23.3 N·m

Rated current

10.7 Arms

Instant maximum current

28 Arms

Rated rotation speed

1,500 min-1

High rotation speed

4,000 min-1

Torque constant

0.891 N·m/Arms

Rotor moment of inertia

22.0 ×10-4 kg·m2

Rated power rating

31.6 kW/s

Rated angle acceleration

3,790 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right)
24.5 m/s2 80.4 ft/s2 (forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

Class F

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

*3

Approx. weight

9.0 kg 19.84 lb

Electromagnetic brake specifications

Capacity

10 W

Rated voltage

24 VDC (−0%/+10%)

Rated current (@20°C 68°F)

0.41 A

Holding torque

19.6 N·m

Release time

100 ms

Operating time

80 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 3,000 min-1. At 4,000 min-1, 1 kW becomes 2×, 1.5 kW becomes 2×, 3 kW (with the SV3-300L2 connected) becomes 2.2×, 3 kW (with the SV3-500L2 connected) becomes 4×, and 5 kW becomes 2.4×.

keyence Stock Image
Keyence GL-RPC03N Keyence
Sale price 6,665.00 kr
Only 2 units left

Specifications

Model

GL-RPC03N

Type

Main Unit Connection Cable, for Extension

Number included

1 cable

Cable end

Main unit plug (Grey) - M12 connector (5-pin male)

Length

0.3 m 0.98'

Material

Main unit connection connector: PBT, Connector for extension: PVC/nickel-plated brass, Cable: PVC

Note

Use this together with the extension cable.

Weight

Approx. 25 g

Keyence Stock Image
Keyence LV-H41 Keyence
Sale price 7,120.00 kr
Only 2 units left

Specifications

Model

LV-H41

Type

Long-distance area

FDA (CDRH) Part 1040.10

Class I

Light source

Invisible infrared semiconductor laser

Wavelength

785 nm

Detecting distance

FINE

250 mm 9.84"

TURBO

500 mm 19.69"

SUPER

1000 mm 39.37"

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Material

Case

Glass reinforced plastic

Lens cover

Polyarylate

Weight

Approx. 45 g

keyence Stock Image
Keyence OP-88296 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88296

Type

Loose wires/M12 adapter

Applicable product

FD-XA1/XA5 cables, or cables with cross sectional area 0.14 to 0.34 mm2
and outer diameter ø 3.5 to 6 mm 0.14 " to 0.24 "

Frequency of connections between conductors of the same cross section

10

Insertion/withdrawal cycles

More than 100 times

Wire diameter including insulation

ø 0.7 to 1.6 mm 0.028 " to 0.06 "

enclosure rating

IP65/67

Ambient temperature

-25 °C to +80 °C -13 to 176 °F

Note

A connector that converts loose wires to a M12 4-pin connector. Useful for connecting to IO-Link compatible master units.

Weight

Approx. 12 g 0.42 oz

Keyence Stock Image
Keyence CA-LH12P Keyence
Sale price 4,726.00 kr
Only 5 units left

Specifications

Model

CA-LH12P

Focal point

12 mm 0.47"

F-stop range (aperture)

F1.4/4/8/16*1

Minimum WD

0.15 m 0.5'

Filter size

27.0 mm 1.06" P0.5

Mount

C-mount

Max. compatible image sensor size

2/3"

Resolving power

100 cycles/mm at center, 80 cycles/mm on periphery

TV distortion

-0.07%
(-0.04%)*2

Enclosure rating

IP64 (objective lens, water repellent coating specifications)*3

Ambient temperature/humidity range

0 to +50°C 32 to 122°F, 80% RH or less (No condensation)

Weight

Approx. 75 g

*1 The f-stop (aperture) is changed by replacing the diaphragm plate. When this product is shipped, the OPEN diaphragm plate is attached to the lens, so replace it with one of the other included diaphragm plates (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture.
*2 This indicates the value with the maximum supported image size. The value in parentheses applies to a 1/3" image sensor size.
*3 When connected to a KEYENCE environmentally resistant camera (excluding when the close-up ring and filter are attached)

Keyence Stock Image
Keyence CA-DP5R Keyence
Sale price 8,603.00 kr
Only 2 units left

Specifications

Model

CA-DP5R

Type

Specialised extension cable for LED spot lighting

Applicable product

CA-DPR2, CA-DPW2, CA-DPB2

Length

5 m 16.40'

keyence Stock Image
Keyence IV4-G400CA Keyence
Sale price 41,836.00 kr
Only 2 units left

Specifications

Model

IV4-G400CA

Type

Long range, narrow field of view model

Installed distance

From 400 mm 15.75"

Field of view

Installation distance of 400 mm 15.75": 58 (H) × 44 (V) mm to
Installation distance of 3000 mm 118.11": 464 (H) × 348 (V) mm
(reference value)

Image receiving element

Type

1/2.9 inch color CMOS

Number of pixels

1280 (H) × 960 (V)

Focus adjustment

Auto *1

Exposure time

12 μs to 9 ms *2

Lights

Illumination

White LED

Lighting method

Switchable between pulse and continuous lighting

Indicators

2 indicators (both displaying same content)

Power supply

Average power consumption

2.5 W (without AI imaging illumination unit installed)
6.6 W (with AI imaging illumination unit installed)

Environmental resistance

Enclosure rating

IP67 *3

Ambient temperature

0 to +50°C 32 to +122°F (no freezing) *4

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Frequency: 10 to 500 Hz;
Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 3 times in each of 6 directions

Material

Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *5

Weight

Approx. 75 g 2.65 oz (no AI imaging illumination unit)
Approx. 225 g 7.94 oz (with AI imaging illumination unit)

*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program.
*2 Maximum exposure time is 500 ms only when lighting is set to OFF.
*3 Except when polarizing filters (OP-88642/OP-88643/OP-88646/OP-88647) are installed.
*4 When the operating ambient temperature exceeds 40°C 104°F, install in accordance with KEYENCE instructions, taking appropriate measures for heat dissipation to ensure that the case temperature does not exceed the rated 65°C 149°F. For the case temperature, measure the side with the “IV4 series” label.
*5 ESD safe and IEC61340-5-1 compliant.

Keyence New Stock Image
Keyence CV-H100M Keyence
Sale price 6,943.00 kr
Only 2 units left

Specifications

Model

CV-H100M

Type

Camera*1

Image element

2/3-inch monochrome CCD image receiving element, 7 x high-speed reading using square-pixel, 1,040,000 pixels Unit cell size 7.4 x 7.4 µm

Valid pixel count

1000000 pixels 1000 (H) × 1000 (V)

Pixel transfer frequency

80 MHz 40 MHz × 2ch

Scanning system

Progressive (20.5 ms)Interlace (13.9 ms)

Transfer system

Digital serial transfer

Electronic shutter

1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values.

Lens mount

C mount

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 120 g (not including lens)

*1 Only the high-speed camera cable can be used.

keyence Stock Image
Keyence MP-FR10R Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

MP-FR10R

Type

Standard model

Connection bore diameter

Rc3/8" (10 A)

Supported gases

Air and non-corrosive gases

Supported gas temperature

-5 to +50°C, 23 to 122°F

Operating pressure range

0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1

Pressure resistance

1.5 MPa, 15 bar, 217.5 psi

Flow rate

Detection principle

Heat based (mass flow rate)

Rated flow range (normal)

2.0 to 1000.0 L/min
0.12 to 60.00 m3/h 4.24 to 2118.88 ft3/h 0.07 to 35.31 CFM

Zero cut flow rate

2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM

Measurement accuracy

±(1.5% of RD + 0.5% of F.S.) *2 *3

Repeatability

±1.0% of F.S. (with an averaging time of 1.0 s)

Display resolution

0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM

Response time

150 ms (63% response) *4

Averaging time

OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable)

Pressure (Digital value, gauge pressure)

Rated pressure range

0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi

Measurement accuracy

±2.0% of F.S.

Repeatability

±0.2% of F.S. (with a response time of 50 ms)

Display resolution

0.001 MPa, 0.01 bar, 0.1 psi

Response time

Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4

Humidity (Dew point)

Rated relative humidity range/ dew point range

15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6

Measurement accuracy

±4°C, ±7°F *5 *6

Display resolution

5%RH/1°C, 1°F *5 *6

Temperature

Measurement accuracy

±2.0°C, ±3.6°F *7

Display resolution

0.1°C, 0.1°F *7

Shut-off valve

Response time

1 s or less (closed → open)

Leakage amount

50 mL/min 0.002 CFM (N) or less

Filter/regulator (Standard model only)

Pressure adjustment range

0.15 to 0.90 MPa

Filtration degree

5 μm 0.196850 Mil

Drainage cup capacity

60 cc

Check valve

Available

Display

Color LCD, status indicator

Data accumulation

Accumulation period

Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks

Data reading

USB 2.0/Ethernet

I/O

Control output (Ch.1/2/3/4/5)

NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less

Analog output (Ch.1/2)

4 to 20 mA, load resistance: 260 Ω or less *4

External input (Ch.2/3/6)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output

Power supply

Power voltage

24 VDC +25%/-20% (including ripple), Class 2 or LPS

Power consumption

1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current)

Communication interface

USB2.0

Network compatibility

When using only this unit: IO-Link (Specification v1.1/COM3) *9
When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP

Environmental resistance

Enclosure rating

IP67 (IEC60529) *10

Ambient temperature

−5°C to +50°C 23°F to 122°F (no freezing) *11

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions

Shock resistance

300 m/s2, XYZ axes, 10 times for each axis

Material

Sensor part : PET/PPS/PBT/POM/aluminum/SPHC
Filter/regulator : Aluminum/POM/HDPE/NBR/Nylon *12

Weight

Approx. 1050 g 37.04 oz (excluding drainage cup)

*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve.
*2 This value is guaranteed by KEYENCE inspection facilities while testing with air. Errors will be introduced by factors such as the gas type, gas temperature, and ambient temperature.
*3 Value in an environment with a constant temperature of 25°C 77°F and compressed air evaluated as purity class 1*1 (ISO 8573-1 (2010)/JIS B 8392-1 (2012)).±(5.5% of RD + 0.5% of F.S.) when equivalent to purity class 3*4.
*4 15 ms is added to the analog output response time.
*5 Measurable when at least 2% of F.S. worth of gas is flowing.
*6 The prescribed accuracy may not be met or the unit may be damaged if the compressed air contains a large amount of oil mist, organic solvent, or other gas. (For details, see “Gas Being Measured” on page 4.)
*7 When the flow is 5% of F.S. or higher. Errors due to heat generated by the main unit occur when the flow is too small.
*8 When connecting MP-FEA1 and/or MP-FEN1, add each device’s current consumption (2.1 A or less including load current).
*9 Use an IO-Link master that can supply 1.2 A or more. (1.6 A or less when connecting an MP-FEA1 and an MP-FEN1.) IO-Link is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 When protection is provided to prevent dust and liquid from intruding through the exhaust port. The IP67 enclosure rating is lost when a USB connection is established.
*11 If this product is used with a power supply voltage of 26.4 V or more, the upper limit on the ambient temperature is 45°C 113°F.
*12 Nylon is only used on the MP-Fx20R.

keyence Stock Image
Keyence XC-H20-01 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

XC-H20-01

Cable length

1 m 3.3'

Cable shape

MIL - MIL

keyence Stock Image
Keyence OP-88036 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CV-X100F Keyence
Sale price 8,784.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence MD-F5120 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

MD-F5120

Console (sold separately)

MC-P1

Marking method

XYZ 3-Axis simultaneous scanning method

Marking laser

Type

Yb: fiber laser, Class 4 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1)

Wavelength

1090 nm

Output

50W

Pulse frequency

60 to 120 kHz

Guide laser/Working distance pointer

Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1)

Marking area

300 x 300 x 42 mm 11.81" x 11.81" x 1.65"

Standard working distance (±variable width)

300 mm (±21 mm) 11.81" (±0.83")

Marking resolution

5 µm 0.20 Mil

Scan speed

8000 mm 314.96/s max.

Character type

Font

KEYENCE original font (numerical value, alphabet, katakana, hiragana, and kanji)/user font/true type font

Barcode

CODE39/ITF/2of5/NW7 (CODABAR)/JAN/EAN/UPC/CODE128

2D code

QR code/micro QR code/DataMatrix (ECC200/GS1 DataMatrix)

GS1 DataBar

GS1 DataBar Truncated/GS1 DataBar Truncated CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/GS1 DataBarLimited/GS1 DataBar Limited CC-A

Logo image

Custom font, logo (CAD) data BMP/JPEG/PNG/TIF

Machinery operation

Fixed point/straight line/dashed line/oval

Marking conditions

Workpiece style

Stationary marking/movement marking (constant speed/encoder)

Character size (marking height/width)

0.1 to 300 mm 0.004" to 11.81"

No. of registered programs

2000 settings max.

No. of program blocks

256 blocks

I/O (Input/output)

Terminal block input and output/MIL connector input and output

Interface

RS-232C, RS-422A, USB 2.0,*2 Ethernet (100BASE-TX/10BASE-T)

CF memory card slot

Compact flash memory card*3

Head installation direction

All directions

Head cable length

4 m 13.12'

Cooling method

Controller: forced air cooling, head: natural air cooling

Rated voltage and power consumption

100 to 120 VAC or 200 to 240 VAC ± 10 %, 50/60 Hz, Max. 750 VA

Environmental resistance

Enclosure rating

IP64 (Head)

Pollution degree

2

Overvoltage category

II

Ambient temperature for storage

-10 to +60 °C 14 to 140 °F (No freezing)

Ambient temperature

0 to +40 °C 32 to 104 °F

Ambient humidity for storage

30 to 85 % RH (No condensation)

Relative humidity

Weight

Controller: 27.5 kg
Head: 6.7 kg
Console: 1.4 kg

*1 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA [CDRH] Laser Notice.
*2 The USB port is dedicated for use with the PC software.
*3 SanDisk cards are recommended.

Keyence Stock Image
Keyence KV-L20V Keyence
Sale price 6,524.00 kr
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence LX2-11W Keyence
Sale price 28,163.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence CA-DZW10X Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CA-DZW10X

Type

LumiTraxTM (specular reflection mode) line lighting

LED color

White

Controller connection

Dedicated cable (3 m 9.8', 5 m 16.4', 10 m 32.8') , 30 m 98.4' max. (when using extension cables*1)

Rating

Power/current consumption

27 W (1.3 A)

Weight

Approx. 800 g

*1 Up to two extension cables can be connected to the dedicated cable.

keyence Stock Image
Keyence ER-GL08P03C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

ER-GL08P03C

Type

General-purpose all-metal shielded type Screw type M8 Connector with pigtail (M12 4-pin) PNP output Long-Range

Power supply cable length

0.3 m 1.0' *1

No. of control outputs

2

Output mode

Output 1

N.O.

Output 2

N.C.

Button

None

Button

Function

Detecting distance

3 mm 0.12" ±10% *2

Response frequency

80 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

9 × 9 mm 0.35" × 0.35"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529), IP67G (JIS C 0920)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Connector with pigtail] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC, Connector resin: TPU, Connector metal: Nickel-plated brass
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 40 g
1.41 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence OP-88196 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88196

Type

M12 power supply cable Outdoor use

Length

10 m 393.70'

Material

PUR, SUS316L

Weight

Approx. 310 g

Keyence Stock Image
Keyence GL-R10L Keyence
Sale price 14,053.00 kr
Only 5 units left

Specifications

Model

GL-R10L

Detection capability

ø1.77" ø45 mm

Total length

15.75" 400mm

No. of beam

10

Detection height

14.17" 360mm

Protection height

17.52" 445mm

Beam axis spacing/Lens diameter

40 mm / ø5 1.57" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

6.6

OFF→ON

48.7*2

All blocked→ON

63.1*3

Optical synchronization system
(Channel A or B)

ON→OFF

7

OFF→ON

49.3*2

All blocked→ON

64.9*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

43

Receiver

69

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

550 g

Receiver

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence WM-B1 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88041 Keyence
Sale price 4,077.00 kr
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence FD-H32F Keyence
Sale price 20,023.00 kr
Only 5 units left

Specifications

Model

FD-H32F

Type

Hose model

Supported pipe diameter

ø23–32.9 ø0.91"-1.295"

Supported pipe materials

Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1

Supported fluids

All fluids (water, oil, chemicals, etc.)*1

Supported fluid temperature

0–100°C 32–212°F (no freezing on pipe surface)*2

Maximum rated flow

200 L/min
52.8 gal/min

Zero cut flow rate

1.0 L/min
0.3 gal/min (variable, initial value)

Detection principle

Delta TOF

Function for automatic correction for speed of sound in liquid

Display

QVGA 2.0 model: color LCD, status indicator light

Display update cycle

Approx. 10 times/second

Display resolution

Instantaneous flow

0.01/0.1/1 (L/min) (default value: 0.1)

Integrated flow

0.01/0.1/1 (L) (default value: 0.1; up to 8 digits)

Response time

0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s

Measurement accuracy

Repeatability

0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4

Hysteresis

Variable

Flow units

L/min m3/h G/min

Pulse output increments (L)

0.02–999.99

Pipe temperature measurement accuracy

Network support

IO-Link*5

Heat calculation function

Unit

MJ/h kW kBTU/h*6

Display resolution

Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6

Pulse output increments (MJ)

0.02–999.99*6

Data accumulation

Accumulation period

Approx. 1 year

Data reading

USB2.0

Power I/O connector

M12 8-pin connector (male)

I/O (switchable)

Output (Ch1/2/3/4)

Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less

Analog output (Ch1/2)

4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less

External input (Ch2/3)

Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input
Short circuit current: 1.5 mA or less; input time: 20 ms or more

Power supply

Power voltage

20–30 VDC, ripple (P-P) 10% included, Class 2/LPS

Current consumption

240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*8

Ambient temperature

Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes

Material

Display unit

Body: PPS/PET/POM; Display window: PAR

Sensor head

Body: PPS/PET/PAR/SUS304; Cable: PVC
Sensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7

Weight

approx. 880 g 31.04 oz

*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.
*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.
*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.
*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*6 Can be used when two temperature sensors (sold separately) are connected.
*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).
*8 When a USB connection is in use, IP65/67 compliance is impaired.

Recently viewed