Specifications
Model |
OP-88899 |
|||
Female |
M12 8pin Straight |
|||
Male |
Strand wire |
|||
Length |
10 m 32.8' |
|||
Material |
cable: Chemicalresistant PVC |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-82C*1 |
|||
Heat resistant temperature |
300°C 572°F*2 |
|||
Fibre unit length |
1 m39.37" cannot be cut |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *3 |
|||
Environmental resistance |
Ambient temperature |
-40 to +300 °C -40 to 572 °F |
||
Weight |
Approx. 29 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-87577 |
|||
Overview |
Plastic flange plate for the FL-C001 (equal to G3/4 JIS5K50A). |
|||
Applicable product |
FL-C001 |
|||
Material |
PVC |
|||




Specifications
Model |
OP-87416 |
|||
Applicable product |
SJ-E |
|||
Note |
This product is used to mount both sides of the SJ-E Series. The mounting dimensions are the same as those for the SJ-H/GL/G/V/R Series. Also, use this product when you want to perform angle adjustments (±90°). |
|||

Specifications
Model |
SJ-M031C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
164 mm 6.457"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



Specifications
Model |
AI-D32H |
|||
Type |
Dome Attachment for Separate amplifier models, Large |
|||
Applicable product |
AI-H100, AI-H160 |
|||
Note |
Effective area 32 × 32 mm 1.26 × 1.26" |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-42126 |
|||
Type |
Expansion loose wire cable |
|||
Applicable product |
EZ-18M, EZ-30M |
|||
Length |
20 m 65.62' roll |
|||
Note |
f5.9, 4-core (Brown, Blue, Black, White) |
|||

Specifications
Model |
GL-FB2400*1*2 |
|||
Length |
2429 mm 95.63" |
|||
Recommended compatible models |
GL-R191F / GL-R96H |
|||
*1 It is also possible to install light curtains with a body length of 640 mm 25.20" or less. | ||||

Specifications
Model |
NR-HA08P *1 |
|||
Input method |
Single-end input / Balanced differential input selection |
|||
Number of channels |
Single-end: 8 ch*2 (Differential: 4 ch) / Current: 4 ch |
|||
Measurement cycle |
Maximum sampling cycle: 1 μs (1 MHz) to 60 s |
|||
A/D converting system |
Successive approximation |
|||
A/D resolution |
14 bit |
|||
Input frequency band |
250 kHz (−3 dB typ.) |
|||
Input impedance |
Voltage |
1 MΩ ±1% |
||
Current |
250 Ω ±1% |
|||
Input type |
Voltage |
±10 V, ±5 V, ±2.5 V, ±1 V, ±0.5 V, ±0.25 V |
||
Current |
±20 mA |
|||
Maximum input rating |
Voltage range |
±30 V |
||
Current range |
±30 mA |
|||
Withstand voltage |
Between measurement input terminal and system bus |
300 VAC (50/60 Hz), 1 minute |
||
Measurable range |
±10 V: −11.000 to +11.000 V |
|||
Measurement accuracy |
Zero-point accuracy |
±0.03% of F.S. |
||
DC amplitude accuracy |
±0.1% of F.S. (10 V/5 V/2.5 V/20 mA range at 16 averages, 1 V/0.5 V/0.25 V range at 128 averages) |
|||
Display resolution |
±10 V: 1 mV |
|||
Buffer memory |
4M data*4 |
|||
Warm up time |
15 minutes or more |
|||
Power supply |
Power consumption |
3.3 W or less |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 170 g 6.00 oz (including approx. 20 g 0.71 oz for the OP-88521 (NR-HA08P terminal block)) |
|||
*1 The above specifications are the values when zero point adjustment is performed after the warm-up period in an environment with a temperature of 23°C ±3°C 73.4°F ±5.4°F. | ||||