Specifications
Model |
CA-HS035MU |
|||
Image element |
Monochrome CMOS, 7× high-speed reading using square-pixel |
|||
Unit cell size |
7.4 µm × 7.4 µm 0.29 Mil × 0.29 Mil |
|||
Valid pixel count |
0.31 megapixel mode: 640 (H) × 480 (V), 0.24 megapixel mode: 512 (H) × 480 (V) |
|||
Image size |
Equivalent to 1/3" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
86 MHz (43 MHz × 2) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.05 to 100 msec by specifying the following numerical inputs: |
|||
Lens mount |
Special mount (M10.5 P0.5 male) |
|||
Environmental resistance |
Ambient temperature |
0 to 40°C 32 to 104°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 75 g (not including lens) |
|||

Specifications
Model |
SJ-E108H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1140 mm 44.88"*3 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1300 g 45.86oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
GL-FB1000*1*2 |
|||
Length |
1029 mm 40.51" |
|||
Recommended compatible models |
GL-R63F / GL-R32H / GL-R16L |
|||
*1 It is also possible to install light curtains with a body length of 640 mm 25.20" or less. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
SV3-M010AK |
|||
General specifications |
Applicable servo amplifier |
SV3-010L2 |
||
Rated output |
100 W |
|||
Rated torque |
0.318 N·m *1 |
|||
Instant maximum torque |
1.11 N·m |
|||
Rated current |
0.85 Arms |
|||
Instant maximum current |
3.1 Arms |
|||
Rated rotation speed |
3,000 min-1 |
|||
High rotation speed |
7,000 min-1 |
|||
Torque constant |
0.413 N·m/Arms |
|||
Rotor moment of inertia |
0.0705 ×10-4 kg·m2 |
|||
Rated power rating |
14.3 kW/s |
|||
Rated angle acceleration |
45,100 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
26 bit |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20% to 80% RH (No condensation) |
|||
Operating atmosphere |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8 ft/s2 with servo motor flange surface as reference |
|||
Impact resistance |
490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: Class A, CE: Class B |
|||
Min. insulation resistance |
500 VDC 10 MΩ or more with insulation resistance meter |
|||
Isolation voltage tolerance |
1,500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35× |
|||
Approx. weight |
0.4 kg 14.11 oz |
|||
*1 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||



Specifications
Model |
FU-67*1 |
|||
Size |
M6 |
|||
Detection arrangement |
Parallel |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Shape |
Straight |
|||
Minimum bend radius |
R2 mm0.079" Tough-Flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 21 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
OP-83198 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V72H, SL-V36L |
|||
Number included |
1 pcs. |
|||
Length |
1,430.2 mm 56.31" |
|||
Material |
Translucent plastic: Polycarbonate Black plastic: ABS |
|||
Note |
To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42 |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
IV3-500MA |
|||
Type |
Standard |
|||
Installed distance |
50 mm 1.97" or more *1 |
|||
Tools |
Available modes |
Standard mode / Sorting mode |
||
Tool with standard mode |
Learning, Outline, Color area *2, Area *3, Edge pixels, Color average *2, Brightness average *3, Width, Diameter, Edge presence, Pitch, |
|||
Number of tools |
Total: 65 tools *5 |
|||
Field of view |
Installed distance 50 mm 1.97": 22 (H) × 16 (V) mm 0.87" (H) × 0.63" (V) to |
|||
Switch settings (programs) |
128 programs (when using SD card) / 32 programs (when not using SD card) |
|||
Image receiving element |
Type |
1/2.9 inch monochrome CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Image history |
Number of storable images |
100 images *6 |
||
Save conditions |
Selectable between NG only, NG and OK near threshold *7, and All *6 |
|||
Focus adjustment |
Auto *4 |
|||
Image data transfer |
Transfer destination |
Selectable between SD card, FTP server and SFTP server |
||
Transfer format |
Selectable between bmp, jpeg, iv3p, and txt, and file names can be modified |
|||
Transfer conditions |
Selectable between NG only, NG and OK near threshold *8, and All |
|||
Exposure time |
12 μs to 10 ms |
|||
Analysis information |
RUN display |
Tools list (Judgment results, degree of similarity, or degree of similarity bar display) *8 |
||
RUN information |
Switchable between OFF, histogram, processing time, count, and output monitor |
|||
Lights |
Illumination |
Infrared LED |
||
Lighting method |
Pulse lighting |
|||
Other functions |
Image capture function |
Digital zoom (2×, 4×), HDR, High gain, Color filter *2, White balance *2, Brightness correction, AI capture |
||
Tool functions |
Additional learning, Mask outline, Masking function, Color extraction/exclusion *2, Color histogram function *2, Monochrome histogram function *3, Scaling function |
|||
Utilities |
Failing sensor list, Failure hold, Test run, I/O monitor, Security settings (Two-factor password), Simulator *9, Additional FTP/SFTP Image Information, |
|||
Indicators |
OUT, TRIG, STATUS, LINK/ACT, SD |
|||
Input |
Type |
Switchable between non-voltage input and voltage input |
||
Number of inputs |
6 ports, 3 ports are selectable as IN/OUT |
|||
Function |
IN1: External trigger, |
|||
Output |
Type |
Photo MOS relay output, N.O./N.C. Switchable |
||
Number of outputs |
6 ports, 3 ports are selectable as IN/OUT |
|||
Function |
Enable by assigning the optional functions |
|||
Power/I/O |
Connector |
M12 12 pin A code Male connector |
||
PoE |
PoE power Class 3/4/6 *11 |
|||
Ethernet |
Standard |
1000BASE-T/100BASE-TX |
||
Connector |
M12 8 pin X code Female connector |
|||
Network function |
FTP client, SFTP client |
|||
Interface compatibility |
Built-in Ethernet |
EtherNet/IP™, PROFINET *12, TCP/IP non-procedure communication |
||
Expanded memory |
microSD card (microSD/microSDHC) *13 |
|||
Ratings |
Power voltage |
24 VDC +25%/-20% (including ripple) *14 |
||
Current consumption |
3.3 A or less (without the AI Lighting unit, and including the output load) |
|||
Environmental resistance |
Enclosure rating |
IP67 *16 |
||
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) *17 |
|||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions *18 |
|||
Shock resistance |
500 m/s2 1640'/s2, 3 times in each of the 6 directions *18 |
|||
Material |
Main unit case: Aluminum die-casting/PBT/TPU |
|||
Weight |
Approx. 300 g 10.59 oz (without the AI Lighting unit) |
|||
*1 Removing the polarizing filter is recommended when used at distances of 3 m 9.8' or more. | ||||




Specifications
Model |
SI-F10 |
|||
Type |
Long distance type Sensor head |
|||
Measurement range |
11.3 to 12.35 mm 0.44" to 0.49" *1 |
|||
Light source |
Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
Spot diameter |
ø40 µm ø0.001575"*3 |
|||
Linearity |
±0.3 µm ±0.000012"*4 |
|||
Resolution |
0.25 µm 0.00000984"*5 |
|||
Sampling cycle |
200 µs |
|||
Light source for guide |
Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
LED display |
Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange. |
|||
Temperature fluctuation |
0.01% of F.S./°C |
|||
Environmental resistance |
Enclosure rating |
IP64 |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
SUS |
|||
Material |
Sensor head |
|||
Spectrum unit |
Polycarbonate |
|||
Weight |
Approx. 38 g (including cable) |
|||
*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01". | ||||

Specifications
Model |
FD-HCC2 |
|||
Cable end |
M12, 8-pin female to M12, 4-pin male |
|||
Length |
2 m 6.6' |
|||
Material |
PVC |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
OP-89263*1 |
|||
Maximum input voltage |
1000 V DC+AC peak |
|||
Maximum allowable voltage to ground |
1000 V CAT II or 600 V CAT III |
|||
Attenuation ratio |
1:1 |
|||
Connector |
Insulated BNC connector |
|||
Cable length |
150 cm |
|||
Weight |
Approx. 120 g |
|||
*1 These specifications refer to the probe only. When connected to a measurement device, refer to the maximum input voltage and amount of ground voltage for the device. | ||||

Specifications
Model |
ER-18PC *1 |
|||
Type |
Ultra-long distance shielded type Screw type M18 Connector (M12 4-pin) PNP output |
|||
Power supply cable length |
― *2 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
15 mm 0.59" ±10% *3 |
||
With distance switching (Mode 2) |
10 mm 0.39" ±10% *3 |
|||
Response frequency |
With default settings (Mode 1) |
20 Hz *4 *5 |
||
With distance switching (Mode 2) |
50 Hz *4 *5 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *6 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
45 × 45 mm 1.77" × 1.77" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) *8 |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *9 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||

Specifications
Model |
FD-MZ100ATK*1 |
|||
Type |
Vertical |
|||
Shape |
Built-in amplifier |
|||
Rated flow range |
1.4 - 26.0 G/min (5.0 - 100 L/min)*1 |
|||
Possible display range |
1.4 - 52.8 G/min (5.0 - 200 L/min)*2 |
|||
Possible ranges to set |
0 - 52.8 G/min (0 - 200 L/min) |
|||
Connection port |
NPT1 (25 A) |
|||
Detectable fluids |
Water or non-corrosive liquid |
|||
Conductivity of detection fluids |
5 µS/cm or higher |
|||
Detection fluid temperature |
0 to +85°C 32 to 185 °F (No freezing) |
|||
Pressure loss |
Max. 1.45 PSI (0.01 MPa) |
|||
Display method |
Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator |
|||
Display resolution |
0.1/1 (G/min, L/min) selectable |
|||
Repeatability |
0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3 |
|||
Hysteresis |
Variable |
|||
Response time (chatter prevention feature) |
0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable |
|||
Accumulated flow unit |
0.1/1/10/100/1000 (G, L) selectable |
|||
Integration data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more) |
|||
Analog output |
4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value |
|||
Integration reset/bank switch input/flow zero function input |
Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode |
|||
Power consumption (Current consumption) |
Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA) |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less, Class 2 |
||
Environmental resistance |
Enclosure rating |
IP65 |
||
Pressure resistance |
290 PSI (2.0 MPa) |
|||
Applied pressure range |
Max. 145 PSI (1.0 MPa) |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Liquid end materials |
Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM) |
||
Other materials |
Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC |
|||
Accessory |
Instruction Manual, Connector cable (2.7 m 106.3") |
|||
Weight |
Approx. 1,340 g |
|||
*1 The rated flow range indicates recommended operating range. | ||||

Specifications
Model |
GL-S20SH |
|||
Type |
Slim type |
|||
Detection capability |
ø25 mm ø0.98" |
|||
Total length |
419.5 mm 16.52" |
|||
No. of beam |
20 |
|||
Detection height |
380mm 14.96" |
|||
Protection height |
426mm 16.77" |
|||
Beam axis spacing |
20 mm 0.79" |
|||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
|||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
6.6 *1 |
|
OFF→ON |
48.7 *1 *2 |
|||
All blocked→ON |
63.1 *1 *3 |
|||
Optical synchronization system (channel A or B) |
ON→OFF |
8.8 *1 |
||
OFF→ON |
52.0 *1 *2 |
|||
All blocked→ON |
71.9 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
|||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
|||
Control output (OSSD output) |
Output type |
2 transistor outputs |
||
Max. load current |
Max. 300 mA |
|||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 200 µA |
|||
Max. load capacitance |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
|||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
39*4 |
Receiver |
62*4 |
|||
When the center indicator is OFF |
Transmitter |
28*4 |
||
Receiver |
50*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (no condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Polyarylate |
||
Weight |
Transmitter |
160 g |
||
Receiver |
165 g |
|||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. | ||||

Specifications
Model |
GL-VM88HN |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
88 |
|||
Total length |
1760 mm 69.29" |
|||
Detection height |
1740 mm 68.50" |
|||
Protection height |
1785 mm 70.28" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
7.5 |
|
OFF→ON |
50.7 *3 |
|||
All blocked→ON |
61.3 *4 |
|||
With channel A or B |
ON→OFF |
23.8 |
||
OFF→ON |
78.0 *3 |
|||
All blocked→ON |
111.8 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
173 *5 |
||
Receiver |
188 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
61 *5 |
||
Receiver |
66 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1140 g 40.24 oz |
||
Receiver |
1160 g 40.94 oz |
|||
Total |
2300 g 81.19 oz |
|||