Machine Vision Systems

5768 products

Showing 4705 - 4728 of 5768 products

Showing 4705 - 4728 of 5768 products
View
keyence Stock Image
Keyence FD-ECA0 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FD-ECA0

Type

Zero line type*1

Number of control outputs

*2

Number of analog outputs

Number of external inputs

*2

Power supply cable

No cable

Response time (90% response)

50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms)*3

I/O

Control outputs 1 and 2

Analog output

External input

Network compatibility

NU Series compatibility

Number of connectible units

Eight units per one NU1 main unit;
four units per one FS-MC8N/P main unit*1

Protection circuit

Protection against incorrect head cable wiring

Power supply

Power voltage

24 VDC ± 10% (including ripple), Class2/LPS

Power consumption

1290 mW excluding load current

Environmental resistance

Ambient temperature

−10°C to +55°C 14 to 131°F (no freezing)*4

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Main unit: polycarbonate, FG terminal: copper/iron

Weight

Approx. 26 g 0.92 oz

*1 To use the zero line type, connect it to the FS-MC8N/P, NU Series.
*2 This counts as 2 outputs/1 input when connecting multiple units to the FS-MC8N/P, NU Series.
*3 5 ms is added to the analog output response time and the response is set to 63%.
*4 The ambient temperature to use varies depending on the number of adjacent cable type/M12 connector type units or depending on the number of expansion zero line type units added to the system. For 1 or 2 units, the temperature is 55°C 131°F. For 3 to 5 units, the temperature is 50°C 122°F. For 6 to 8 units, the temperature is 45°C 113°F. The prescribed values for the ambient temperature assume that the amplifier unit has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

keyence Stock Image
Keyence OP-89008 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-89008

Type

M12 connector (5 pin)-M12 connector (8 pin) adapter connector

Number included

1 pc.

Keyence Stock Image
Keyence RC-18 Keyence
Sale price 7,186.00 kr
Only 2 units left

Specifications

Model

RC-18

Type

1-level preset counter/timer, DC type

Operation method

Addition, subtraction

Operation mode

Overcount, auto reset

Return method

Manual reset, external reset, automatic reset (in auto reset mode)

Display power

7-segment LED (character height: 12 mm)

Number of digits

4-digit display, -999 to 9,999*1

Power off memory time

Approx 10 years (at 20°C 68°F)

Mounting method

Panel mount (embedding), surface mount, DIN rail mount*2

Highest counting speed

With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio)

Input signal

No-voltage input (with contacts, without contacts [count input, inhibit input, reset input])

Output

Control output

Relay output: 1c, 250 VAC, 3 A or less (resistive load)

Control output

One-shot output time

0.01 s to 0.5 s (variable)

Relay

24 ms or less (when set to 30 Hz), 12 ms or less (when set to 5 kHz)

DC output

12 VDC ± 10%, 50 mA maximum

Rating

Power voltage

100 to 240 VAC ±10 %, 50/60 Hz

Power consumption

9VA or less

Current consumption

-

Environmental resistance

Insulation resistance

100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case

Noise resistance

Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Withstand voltage

1,000 VAC for 1 minute (between all the external terminals and the case)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 3 times in each of the X, Y, and Z directions

Weight

Approx. 170 g (main unit only)

*1 Display uses the zero suppression method.
*2 Option OP-91867 is required to perform surface or DIN rail mounting.

keyence Stock Image
Keyence FU-L50Z Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FU-L50Z*1

Optical axis diameter
(Standard target to be detected)

ø3.5 mm0.138"

Beam emitting direction

Top

Optical axis height

10 mm0.394"

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø2.2

Minimum bend radius

R2 mm0.079" Tough-Flex

Minimum detectable object

Object with a diameter of 0.2 mm0.008"*2

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F

Weight

Approx. 30 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

keyence Stock Image
Keyence OP-84250 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-84250

Overview

Front protective cover protecting detection side of light curtain.

Applicable product

SL-V119FM, SL-V60HM, SL-V30LM

Number included

1 pcs.

Length

1,205 mm 47.44"

Material

Translucent plastic: Polycarbonate Black plastic: ABS

keyence Stock Image
Keyence SJ-L005G Keyence
Sale price 17,066.00 kr
Only 4 units left

Specifications

Model

SJ-L005G

Voltage application method

High frequency AC method

Applied voltage

3.2 kVAC

Ion balance

±10 V*1

Static elimination time

0.4 sec.*1

Operating distance

50 mm 1.97" or more

Air supply pressure

0.05 to 0.7 Mpa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø8 0.31", inner diameter: ø6 0.24"

Ozone concentration

0.05 ppm or less*2

Ratings

Power voltage

12 VDC (dedicated AC adapter OP-88020/87722 *3)

Current consumption

0.3 A max.

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Drop resistance

Onto concrete from a height of 2.0 m 6.6'*4

Material

Main unit case: PC / Status indicator: TPU / Cable: PVC, copper alloy
Main unit connector: PBT, brass + Ni plating, brass + gold plating
Protection rubber: HNBR (tip side), NBR (connector side)

Weight

Approx. 320 g

*1 Measurement results taken with an installation distance of 150 mm 5.91" and air supply pressure of 0.2 MPa (typical values)
*2 Measurement results taken with an installation distance of 100 mm 3.94" and air supply pressure of 0.1 MPa (typical values)
*3 Rated input of 100 to 240 VAC, 50/60 Hz
*4 This is a typical value under KEYENCE measurement conditions and not a guaranteed value.

keyence Stock Image
Keyence OP-89021 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-89021

Length

5 m 16.4'

Keyence Stock Image
Keyence DD-960 Keyence
Sale price 12,196.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-78041 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-78041

Type

Dust boot

Applicable product

GT-H10

Number included

1 unit

Note

The dust boot is equipped to the head when shipped

Keyence Stock Image
Keyence FU-35FZ Keyence
Sale price 1,219.00 kr
Only 10 units left

Specifications

Model

FU-35FZ*1

Size

M3

Detection arrangement

Coaxial

Fibre unit length

1 m39.37" free-cut

Fibre unit diameter

ø1.3×2

Shape

Straight

Minimum bend radius

R2 mm0.079" Tough-Flex

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F

Weight

Approx. 6 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

keyence Stock Image
Keyence GS-P8CC5 Keyence
Sale price 5,207.00 kr
Only 2 units left

Specifications

Model

GS-P8CC5

Type

For extension/Standard type (8-pin)

Length

5 m 16.40'

Weight

Approx. 240 g

keyence Stock Image
Keyence OP-87740 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence FU-88K Keyence
Sale price 5,025.00 kr
Only 2 units left

Specifications

Model

FU-88K*1

Optical axis diameter
(Standard target to be detected)

ø1 mm0.039"

Heat resistant temperature

200°C 392°F*2

Fibre unit length

2 m78.74", cannot be cut

Minimum bend radius

R8 mm0.315"

Minimum detectable object

Object with a diameter of 0.005 mm0.0002"*3

Environmental resistance

Ambient temperature

-40 to +200 °C -40 to 392 °F

Weight

Approx. 30 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature.
*3 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

Keyence Stock Image
Keyence KV-C32XC Keyence
Sale price 3,939.00 kr
Only 5 units left

Specifications

Model

KV-C32XC

Type

Input Unit

External connection method

Connector (MIL standard)*1

Input

Number of inputs

32 points

Input mode

24 VDC mode, 5 VDC mode

Maximum input voltage

26.4 VDC

Rated input voltage

24 VDC mode: 24 VDC, 5.3 mA, 5 VDC mode: 5 VDC, 1 mA

Minimum ON voltage

24 VDC mode: 19 V, 5 VDC mode: 3.5 V

Maximum OFF current

24 VDC mode: 1.5 mA

Maximum OFF voltage

5 VDC mode: 1.5 V

Common method

32 points/1 common (2 terminals)*2

Input time constant

[Input time constant setting 25 µs] OFF to ON: Typ. 25 µs/Max. 65 µs, ON to OFF: Typ. 75 µs/Max. 120 µs
[Input time constant setting 300 µs*3] OFF to ON: Typ. 275 µs/Max. 365 µs, ON to OFF: Typ. 275 µs/Max. 420 µs
[Input time constant setting 1 ms] OFF to ON: Typ. 1 ms/Max. 1.2 ms, ON to OFF: Typ. 1 ms/Max. 1.2 ms
[Input time constant setting 10 ms] OFF to ON: Typ. 10 ms/Max. 12 ms, ON to OFF: Typ. 10 ms/Max. 12 ms
(four-level switching)

Input impedance

4.3 kΩ

Internal current consumption

15 mA or less

Weight

Approx. 110 g

*1 Connectors for connector-type I/O units are not included XC Series Terminal Block Conversion Unit is available.
*2 Even though KV-B16XC and KV-C32XC have two common points, they are the same internally.
*3 Configurable only when KV-8000A/7500/7300/5500/5000/3000 is connected. Cannot be selected when connected to KV-1000/700.

Keyence Stock Image
Keyence XG-X2200 Keyence
Sale price 48,049.00 kr
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence KV-10RW Keyence
Sale price 3,199.00 kr
Only 3 units left
Buy the Keyence KV-10RW - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence KV-10RW is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence CB-BR01 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CB-BR01

Type

Extension connection unit

Cable min. bending R

22 mm 0.87"

Power source

Supplied from the controller

Environmental resistance

Enclosure rating

None

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

20 to 85 % RH (No condensation)

Weight

Approx. 150 g (including cable)

Keyence Stock Image
Keyence KV-8ERW Keyence
Sale price 4,287.00 kr
Only 3 units left
Buy the Keyence KV-8ERW PLC Module - a programmable logic controller component from Keyence's industrial automation platform. Provides reliable process control, I/O interfacing, and communication capabilities for manufacturing and process systems. The Keyence KV-8ERW is a direct drop-in replacement for existing PLC installations.
keyence Stock Image
Keyence ER-08TPC Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

ER-08TPC *1 *2

Type

Ultra-long distance shielded type Screw type M8 Connector (M8 3-pin) PNP output

Power supply cable length

*3

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching, Through-Metal

Detecting distance

With default settings (Mode 1)

4.5 mm 0.18" ±10% *4

With distance switching (Mode 2)

3 mm 0.12" ±10% *4

Response frequency

With default settings (Mode 1)

20 Hz *5 *6

With distance switching (Mode 2)

80 Hz *5 *6

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *7

Standard detectable object (Iron, t = 1 mm 0.04")

13.5 × 13.5 mm 0.53" × 0.53"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *8

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V) *9

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *10

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Connector with pigtail] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC, Connector resin: TPU, Connector metal: Nickel-plated brass
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 20 g
0.71 oz

*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps).
*2 Long-body type. See “Dimensions” for details.
*3 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections.
*4 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*5 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*6 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*7 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*8 Residual voltage is for when a 2 m 6.6' cable is used.
*9 For IO-Link-compatible devices listed under *1, power consumption is as follows.
M8: 840 mW or less (35 mA or less at 24 V, 53 mA or less at 16 V)
M12: 1090 mW or less (46 mA or less at 24 V, 69 mA or less at 16 V)
M18, M30: 1250 mW or less (53 mA or less at 24 V, 79 mA or less at 16 V)
*10 The upper limit of the UL temperature rating is +55℃ +131℉.

Keyence Stock Image
Keyence EG-547 Keyence
Sale price 10,597.00 kr
Only 6 units left

Specifications

Model

EG-547*1

Type

AC, tolerance setting*2

Sensitivity adjustment

10-turn potentiometer dial

Function

Operation mode

External synchronization,
analog voltage
switch-selectable

Operation mode

External synchronization

Equipment (both without contacts and with contacts)

Output

Control output 1 (NPN)

100 mA max. (40 V max.) Residual voltage: 1 V max.

Control output 2

DPST (N.O.), 250 VAC,
0.5 A max.
(resistive load)

Disconnection alarm output
(NPN)

Response
time (Relay contact)

1 ms

3 ms

OFF-delay time

Temperature characteristics

0.08%/°C*3

Rating

Power voltage

110/120/220/240 VAC ±10 %, 50/60 Hz

Power consumption

5 VA max.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 390 g

*1 The EG-547(W) cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822.
*2 Please contact KEYENCE for information on products that comply with the EMC directive.
*3 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance.

keyence Stock Image
Keyence IG-TB02 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IG-TB02

Type

Fittings

Applicable product

IG-028

Note

Screws for the purpose of connecting the sensor head and mounting brackets are included.

Weight

Approx. 40 g

keyence Stock Image
Keyence AP-34K Keyence
Sale price 4,001.00 kr
Only 1 unit left

Specifications

Model

AP-34K

Type

Compound pressure, NPN

Rated pressure

29.9 to -29.9 inchHg

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43")

Display resolution

0.1 inchHg, 0.2 kPa, 2 mmHg, 0.002 bar

Detectable pressure range

-15 to +110 % of F.S.

Display temperature characteristic

±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F)

Response time (Chattering prevention function)

2.5/5/100/500 ms (selectable)

I/O

Analog output

1 to 5 V (Load impedance: 47 kΩ min.)

Control output

NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable)

Rating

Power voltage

12 to 24 VDC ±10 %

Current consumption

50 mA (at 24 V) or less, 90 mA (at 12 V) or less

Environmental resistance

Pressure resistance

72.5 PSI

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,
Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable

Weight

Approx. 120 g

Keyence New Stock Image
Keyence XG-X2902 Keyence
Sale price 34,492.00 kr
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence KV-E8X Keyence
Sale price 5,559.00 kr
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed