PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
EX-V05P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
ø14.5 x 20 mm ø0.57" x 0.79" Cylindrical, threaded |
|||
Measuring range |
0 to 5 mm 0.20" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 µm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||

Specifications
Model |
GL-VA960 |
|||
Compatible with GL-V models |
GL-VM95F, GL-VM48H, GL-VM24L (both PNP/NPN) |
|||
Total length |
960 mm 37.80" |
|||
Material |
Polycarbonate |
|||
Weight |
100 g |
|||

Specifications
Model |
MP-F10ADP |
|||
Type |
Auto drain cup |
|||
Connection diameter |
NPT3/8 (10A) |
|||
Material |
Polycarbonate |
|||


Specifications
Model |
FU-A40*1 |
|||
Type |
Array thrubeam 40 mm 1.57" type |
|||
Optical axis area (Standard detection target) (mm inch) |
40 × 0.25 mm1.575" × 0.01" |
|||
Fibre unit length |
2 m 6.6' *2 (Free-cut) ø2.2 mm ø0.09" Spiral parts cannot be cut |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Minimum detectable object |
ø2.5 mm ø0.10" opaque object*3 |
|||
Tightening torque |
0.75 N∙m |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case : Die-cast zinc, Detecting surface : PBT, Core fiber : Acrylic, Fiber sheath : Polyethylene |
|||
Accessories |
Fiber cutter, Mounting screws (M4 X L8, 4 units) |
|||
Weight |
Approx. 70 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
CL-S015EX *1 |
|||
Type |
Sensor head (Explosion-proof 15 mm model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-51627 |
|||
Overview |
Front-mounting bracket MS2-H75/H100. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H75/H100 |
|||
Weight |
Approx. 106 g |
|||




Specifications
Model |
CA-LA8 |
|||
Focal point |
8 mm 0.31" |
|||
F-stop range (aperture) |
F1.4 to F16 |
|||
Minimum WD |
0.05 m 0.16' |
|||
Mount |
C-mount |
|||
Filter size |
M40.5 × P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
0.39% |
|||
Resolving power |
120 cycles/mm at center, 100 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 100 g 3.53 oz |
|||

Specifications
Model |
GL-RA960 |
|||
Type |
Front Protection Cover |
|||
Overview |
Plastic cover that is used to protect the detecting surface. |
|||
Applicable product |
GL-R95F, GL-R48H, GL-R24L |
|||
Number included |
1 unit |
|||
Material |
Frame: ABS, Transparent parts: Polycarbonate |
|||
Weight |
Approx. 90 g |
|||

Specifications
Model |
OP-96436 |
|||
Overview |
Compact reflector (R-3) used with polarized retro-reflective photoelectric sensor. |
|||
Applicable product |
PZ2-61, PZ2-62, PZ-G61, PZ-G62 |
|||
Number included |
1 pcs. |
|||
Material |
Reflector: Acrylic, Base: ABS |
|||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SZ-VB11 |
|||
Type |
Mounting bracket |
|||
Applicable product |
SZ-V Series |
|||
Number included |
1 |
|||
Material |
SPCC |
|||
Note |
Accessories: M4 screw x 2, M5 screw x 6 |
|||
Weight |
Approx. 700 g |
|||

Specifications
Model |
FU-95 |
|||
Type |
Liquid-level detection fiber unit |
|||
Detecting method |
Pipe mounting type |
|||
No. of beam axes |
1 mm0.039" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Accessories |
Binding band × 2, nonslip rubber × 2, spacer × 2, screw × 2, nut × 2, Fiber cutter × 1, Adaptor B × 1 |
|||
Weight |
Approx. 7 g |
|||

Specifications
Model |
OP-89229 |
|||
Overview |
It converts NPN type I/O of the SJ-E/H/Q Series to PNP type. It cannot be used in conjunction with OP-87422. |
|||
Note |
PNP Conversion Box |
|||

Specifications
Model |
CV-L25 |
|||
Focal point |
25 mm 0.98" |
|||
F-stop range (aperture) |
F1.6 to F16 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Mount |
C-mount |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
-0.6 % (-0.1 %)*1 |
|||
Resolving power |
100 cycles/mm at center, 40 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50 °C 32 to 122°F, 35 to 80 % RH (No condensation) |
|||
Polarizing filter |
OP-54029 |
|||
Protective filter |
CA-LF27 |
|||
Weight |
Approx. 58 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||