Specifications
Model |
MB3-H3D1 |
|||
Type |
3D add-in software for Marking Builder 3 (marking on plane, cylinder, cone, or sphere; Z-MAP marking) |
|||
Supported operating systems |
Windows 11, 10, 8.1, 8, 7 (SP1 or later) *1 |
|||
Supported languages |
English, Japanese, Simplified Chinese, German, Korean, French, Spanish, Thai, Italian. |
|||
*1 Windows is either registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. | ||||

Specifications
Model |
GL-R159F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
62.99" 1600mm |
|||
No. of beam |
159 |
|||
Detection height |
62.20" 1580mm |
|||
Protection height |
63.15" 1604mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
21.6 |
|
OFF→ON |
71.2*2 |
|||
All blocked→ON |
123.3*3 |
|||
Optical synchronization system |
ON→OFF |
33.0 |
||
OFF→ON |
88.3*2 |
|||
All blocked→ON |
168.7*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
85 |
||
Receiver |
102 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
2300 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
GL-R44H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Total length |
34.65" 880mm |
|||
No. of beam |
44 |
|||
Detection height |
33.86" 860mm |
|||
Protection height |
35.63" 905mm |
|||
Beam axis spacing/Lens diameter |
20 mm / ø5 0.79" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
9.2 |
|
OFF→ON |
52.6*2 |
|||
All blocked→ON |
73.5*3 |
|||
Optical synchronization system |
ON→OFF |
12.9 |
||
OFF→ON |
58.2*2 |
|||
All blocked→ON |
88.6*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
66 |
||
Receiver |
77 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1220 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
GL-VM12LN |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
12 |
|||
Total length |
480 mm 18.90" |
|||
Detection height |
440 mm 17.32" |
|||
Protection height |
525 mm 20.67" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.3 |
|
OFF→ON |
46.2 *3 |
|||
All blocked→ON |
51.9 *4 |
|||
With channel A or B |
ON→OFF |
11.0 |
||
OFF→ON |
56.8 *3 |
|||
All blocked→ON |
71.5 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
77 *5 |
||
Receiver |
90 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
50 *5 |
||
Receiver |
57 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
320 g 11.29 oz |
||
Receiver | ||||
Total |
640 g 22.59 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
ER-U12P |
|||
Type |
Ultra-long distance unshielded type Screw type M12 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
18 mm 0.71" ±10% *2 |
||
With distance switching (Mode 2) |
12 mm 0.47" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
15 Hz *3 *4 |
||
With distance switching (Mode 2) |
50 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
54 × 54 mm 2.13" × 2.13" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 75 g 2.65 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
EM-054A*1 |
|||
Type |
Shielded |
|||
Shape |
5.4 mm 0.21" dia Cylindrical. |
|||
Detecting distance |
1.2 mm 0.05" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
6 x 6 mm 0.24" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Control output |
NPN: 200 mA (40 V) max., Residual voltage: 1 V max. |
|||
Housing |
Stainless steel |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*2 |
||
Current consumption |
12 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 40 g (including nuts and 2-m 6.6' cable) |
|||
*1 The alternate-frequency type of EM-054 | ||||

Specifications
Model |
IV4-G400MA |
|||
Type |
Long range, narrow field of view model |
|||
Installed distance |
From 400 mm 15.75" |
|||
Field of view |
Installation distance of 400 mm 15.75": 58 (H) × 44 (V) mm to |
|||
Image receiving element |
Type |
1/2.9 inch monochrome CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Focus adjustment |
Auto *1 |
|||
Exposure time |
12 μs to 9 ms *2 *3 |
|||
Lights |
Illumination |
Infrared LED |
||
Lighting method |
Pulse lighting |
|||
Indicators |
2 indicators (both displaying same content) |
|||
Power supply |
Average power consumption |
2.5 W (without AI imaging illumination unit installed) |
||
Environmental resistance |
Enclosure rating |
IP67 *4 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *5 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions |
|||
Material |
Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *6 |
|||
Weight |
Approx. 75 g 2.65 oz (no AI imaging illumination unit) |
|||
*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program. | ||||


Specifications
Model |
GL-VB31 |
|||
Number included |
2 |
|||
Material |
SUS304, NBR |
|||
Weight |
140 g 4.94 oz *1 |
|||
*1 GL-V Mounting includes two mounting brackets. The weight stated is for both items. | ||||

Specifications
Model |
LV-H32 |
|||
Type |
Adjustable beam spot |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
30 to 250 mm 1.181" to 9.842" |
||
TURBO |
30 to 500 mm 1.181" to 19.685" |
|||
SUPER |
30 to 1000 mm 1.18" to 39.37" |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case |
Glass reinforced plastic *1 |
||
Lens cover |
Acrylic *2 |
|||
Weight |
Approx. 45 g |
|||
*1 Norbornene plastic or acrylic | ||||

Specifications
Model |
GL-S12FH |
|||
Type |
Flat type |
|||
Detection capability |
ø25 mm ø0.98" |
|||
Total length |
259.5 mm 10.22" |
|||
No. of beam |
12 |
|||
Detection height |
220mm 8.66" |
|||
Protection height |
266mm 10.47" |
|||
Beam axis spacing |
20 mm 0.79" |
|||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
|||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
6.6 *1 |
|
OFF→ON |
48.7 *1 *2 |
|||
All blocked→ON |
63.1 *1 *3 |
|||
Optical synchronization system (channel A or B) |
ON→OFF |
7.4 *1 |
||
OFF→ON |
49.9 *1 *2 |
|||
All blocked→ON |
66.3 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
|||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
|||
Control output (OSSD output) |
Output type |
2 transistor outputs |
||
Max. load current |
Max. 300 mA |
|||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 200 µA |
|||
Max. load capacitance |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
|||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
34*4 |
Receiver |
56*4 |
|||
When the center indicator is OFF |
Transmitter |
27*4 |
||
Receiver |
48*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (no condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Polyarylate |
||
Weight |
Transmitter |
125 g |
||
Receiver |
130 g |
|||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. | ||||


Specifications
Model |
GL-VM16HP |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
16 |
|||
Total length |
320 mm 12.60" |
|||
Detection height |
300 mm 11.81" |
|||
Protection height |
345 mm 13.58" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.5 |
|
OFF→ON |
46.5 *3 |
|||
All blocked→ON |
52.5 *4 |
|||
With channel A or B |
ON→OFF |
11.7 |
||
OFF→ON |
55.8 *3 |
|||
All blocked→ON |
71.5 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
69 *5 |
||
Receiver |
80 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
50 *5 |
||
Receiver |
57 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
220 g 7.76 oz |
||
Receiver | ||||
Total |
440 g 15.53 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CL-P150N |
|||
Type |
Optical unit |
|||
Head |
CL-P150 *1 |
|||
Reference distance |
150 mm 5.91" |
|||
Reference measurement range |
Measurement range |
±35 mm ±1.38" |
||
Linearity |
±5.65 μm ±0.000222" *2 |
|||
High precision measurement range |
Measurement range |
±15 mm ±0.59" |
||
Linearity |
±4.65 μm ±0.000183" *2 |
|||
Resolution |
0.25 μm 0.000010" |
|||
Spot diameter |
ø75 μm ø0.0030" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 380 g 13.41 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
ER-GW08N |
|||
Type |
Weld-resistant all-metal shielded type Screw type M8 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
3 mm 0.12" ±10% *2 |
||
With distance switching (Mode 2) |
1.5 mm 0.06" ±10% *2 |
|||
Response frequency |
2 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
9 × 9 mm 0.35" × 0.35" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less (32 mA or less at 24 V, 47 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +85°C -13°F to +185°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface and case: SUS303 with ceramic coating, Button: PBT, Nut: SUS303 with ceramic coating, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g 2.29 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
FU-25*1 |
|||
Size |
M6 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Shape |
Straight |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 18 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
OP-83210 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V120H, SL-V60L |
|||
Number included |
1 pcs. |
|||
Length |
2,390.2 mm 94.1" |
|||
Material |
Translucent plastic: Polycarbonate Black plastic: ABS |
|||
Note |
To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42 |
|||

Specifications
Model |
OP-88105 |
|||
Type |
Rear Mounting Bracket |
|||
Applicable product |
AI-H050, AI-H100, AI-H160 |
|||
Note |
Standard/Long Range, for Separate Amplifier |
|||

Specifications
Model |
GL-SA12S |
|||
Type |
Protection cover Slim type for 12 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S12SH |
|||
Number included |
1 |
|||
Length |
262.6 mm 10.34" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
90 g |
|||

Specifications
Model |
FU-V7FN*1 |
|||
Type |
Atmosphere-side fiber unit (thrubeam model heat resistant to 70°C 158°F) |
|||
Detecting method |
Thrubeam |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R25 mm0.984" or more |
|||
Minimum detectable object |
Opaque material with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 30 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
SJ-M200 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec. max.*1 |
|||
Ion balance |
±15 V*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation)*3 |
|||
Weight |
Approx. 300 g |
|||
*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min, | ||||