Specifications
Model |
OP-66849 |
|||
Overview |
Expansion cable for transmitter side of thrubeam unit. |
|||
Applicable product |
LV-S Series thrubeam |
|||
Cable end |
Loose wire |
|||
Length |
20 m 65.62' roll |
|||


Specifications
Model |
XC-T40E2 |
|||
Rated voltage |
125 VAC/DC |
|||
Rated current |
1 A/pin |
|||
Ambient operating temperature |
−40 to +80°C −40 to +176°F |
|||
Screw torque |
0.5 N·m (max.) |
|||
Applicable wire diameter |
AWG24 to 12 |
|||
Environmental resistance |
Insulation resistance |
500 VDC, 500 MΩ or greater |
||
Withstand voltage |
500 VAC, 1 minute, 1 mA or less |
|||


Specifications
Model |
SV2-B005AK |
|||
General specifications |
Applicable servo amplifier |
SV2-005L2 |
||
Rated output |
50 W |
|||
Rated torque |
0.159 N·m *1 |
|||
Instant maximum torque |
0.557 N·m |
|||
Rated current |
0.55 Arms |
|||
Instant maximum current |
2.0 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.316 N·m/Arms |
|||
Rotor moment of inertia |
0.0475 ×10-4kg·m2 |
|||
Rated power rating |
6.40 kW/s |
|||
Rated angle acceleration |
40200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.6 kg |
|||
Electromagnetic brake specifications |
Capacity |
5.5 W |
||
Rated voltage |
24 VDC ±10% |
|||
Rated current (@20°C 68°F) |
0.23 A |
|||
Holding torque |
0.159 N·m |
|||
Release time |
60 ms *2 |
|||
Operating time |
100 ms *2 |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
CA-DRW5X |
|||
Type |
High-Intensity LumiTraxTM Light |
|||
LED color |
White |
|||
Power consumption |
34.5 W (during normal light emission) |
|||
Weight |
Approx. 190 g |
|||

Specifications
Model |
GL-R143F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
56.69” 1440mm |
|||
No. of beam |
143 |
|||
Detection height |
55.91” 1420mm |
|||
Protection height |
56.85” 1444mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
19.9 |
|
OFF→ON |
68.6*2 |
|||
All blocked→ON |
116.4*3 |
|||
Optical synchronization system |
ON→OFF |
30.2 |
||
OFF→ON |
84.1*2 |
|||
All blocked→ON |
157.6*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
81 |
||
Receiver |
98 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
2100 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
GS-MB13 |
|||
Type |
Hinged door |
|||
Applicable model |
for GS-M5 Series |
|||
Frame size |
40 - 45 mm 1.57" - 1.77" |
|||
Weight |
Approx. 130 g 4.59 oz |
|||

Specifications
Model |
CB-PN100 |
|||
Type |
PROFINET unit |
|||
Compatible network |
PROFINET IO communication |
|||
Ethernet |
Compliant standards |
IEEE 802.3u*1 |
||
Transmission speed |
100 Mbps, full duplex (100BASE-TX) |
|||
Transmission media |
STP or Category 5e or higher UTP |
|||
Maximum cable length |
100 m 328.1' |
|||
PROFINET IO |
Supported functions |
Data I/O communication, Record data communication |
||
Number of connectable PROFINET IO controllers |
1 |
|||
Update Time |
2 ms to 2,048 ms |
|||
GSDML |
Version 2.25 |
|||
Conformance class |
Conformance Class A compliant |
|||
Conformance test version |
Based on Version 2.2.4 |
|||
Applicable protocol |
LLDP, DCP |
|||
Rating |
Power voltage |
24 V ±10 % (supplied from the controller unit of the laser scanner) |
||
Current consumption |
0.12 A or less |
|||
Weight |
Approx. 470 g |
|||
*1 Although this unit conforms to IEEE 802.3u and can establish 100 Mbps full duplex communication using AutoNegotiation function, it does not have AutoCrossOver and AutoPolarity functions that are normally required for the PROFINET IO standard. Select a straight or cross cable according to the Ethernet port of the device to be connected. | ||||

Specifications
Model |
VT-P15 |
|||
Type |
15" protective sheet |
|||
Applicable product |
for VT5-WX15/X15 |
|||
Number included |
Set of 5 sheets |
|||
Note |
black, without logo |
|||

Specifications
Model |
BT-ACG74 |
|||
Dedicated AC adaptor specifications (OP-88389) |
Input |
100 to 240 VAC 50/60Hz 70VA |
||
Output |
12 VDC 5.0 A maximum (60 W max.) |
|||
Average active efficiency |
89% or more |
|||
Efficiency at low load (10%) |
87% or more |
|||
No-load power consumption |
0.04 W |
|||
Dimensions |
110 x 62.0 x 31.5 mm (excluding the cable) |
|||
Weight |
Approx. 150 g (excluding the AC cable) |
|||
Dimensions |
188 x 64 x 96 mm |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C (No freezing) |
||
Relative humidity |
20 to 85%RH (No condensation) |
|||
Storage temperature |
-20 to +70°C (No freezing) |
|||
Storage relative humidity |
20 to 85%RH (No condensation) |
|||
Weight |
Approx. 470 g |
|||

Specifications
Model |
XM-5000 |
|||
Camera unit |
Maximum measurement length |
W × D × H |
2000 × 1200 × 1000 mm 78.74" × 47.24" × 39.37" |
|
Indication error accuracy |
±(7 + 9L/1000) μm *1 |
|||
Repeatability |
±3 μm |
|||
Minimum display unit |
Distance |
0.0001 mm 0.000004" |
||
Angle |
0.0001 degrees |
|||
Camera unit rotation angle |
Theta rotation |
±40° |
||
Tilt rotation |
±25° |
|||
Weight |
Approx. 8 kg 17.64 lb |
|||
External input |
2 inputs |
Maximum applied voltage: 26.4 V, ON voltage: 19 V or more, OFF current: 0.1 mA or less |
||
External output |
7 outputs (OK/NG/FAIL/MEASURE/ERROR/TOUCH/STROBE) |
Maximum applied voltage: 30 V, Maximum sink current: 50 mA, |
||
Probe |
Number of possible connections |
1 |
||
Communication unit |
WLAN communication |
IEEE 802.11b/g/n |
||
USB communication |
USB 3.0 |
|||
Infrared communication |
945 nm |
|||
Power supply |
Supplied from dedicated AC adapter |
|||
Rating |
Rated voltage |
24 VDC |
||
Current consumption |
1.7 A |
|||
Environmental resistance |
Operating ambient temperature |
10 to 35°C 50 to 95°F |
||
Operating ambient humidity |
20 to 80% RH (no condensation) |
|||
Probe |
Marker |
Number of markers |
7 |
|
Light source |
870 nm |
|||
Applicable stylus |
M5 |
|||
Display |
Display method |
OLED |
||
Resolution |
96 × 39 pixels |
|||
Hardware keys |
MEASURE, OK, CANCEL, CAMERA, Trigger, Power |
|||
Communication unit |
WLAN communication |
IEEE 802.11b/g/n |
||
USB communication |
USB 2.0 |
|||
Infrared communication |
945 nm |
|||
Power supply |
Battery |
Dedicated lithium-ion battery pack |
||
Capacity |
3350 mAh |
|||
Charging time |
Approx. 6 hours |
|||
Continuous usage time |
Approx. 8 hours |
|||
Rating |
USB connection |
Rated voltage |
5 VDC |
|
Current consumption |
1 A |
|||
Battery |
Rated voltage |
3.6 VDC |
||
Current consumption |
1.25 A |
|||
Environmental resistance |
Operating ambient temperature |
10 to 35°C 50 to 95°F |
||
Operating ambient humidity |
20 to 80% RH (no condensation) |
|||
Weight |
Approx. 630 g 22.24 oz |
|||
*1 Refer to ISO 10360-2 (in the range of 800 × 400 × 500 mm 31.50" × 15.75" × 19.69" and when the ambient temperature is 20°C ±1°C 68 ±1.8°F; “L” represents the measurement length (Unit: mm inch)) | ||||

Specifications
Model |
SJ-H108 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1080 mm 42.52" *3 |
|||
No. ofelectrodes |
24 |
|||
Static elimination bar length |
1040 mm 40.94" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1250 g 44.09 oz |
||
*1 Measured under the following conditions. | ||||

Specifications
Model |
FD-ECA1C |
|||
Type |
M12 connector type*1 |
|||
Number of control outputs |
2 |
|||
Number of analog outputs |
1 |
|||
Number of external inputs | ||||
Power supply cable |
Pigtail, 100 mm 3.94", M12 connector, 8 pins of which 6 are used pins used |
|||
Response time (90% response) |
50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms)*2 |
|||
I/O |
Control outputs 1 and 2 |
Instantaneous flow/Accumulated flow/Alarm output/Pulse output |
||
Analog output |
Instantaneous flow |
|||
External input |
Zero flow/Origin adjust./Reset total |
|||
Network compatibility |
IO-Link*3 |
|||
Number of connectible units |
─ |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection, and incorrect head cable wiring |
|||
Power supply |
Power voltage |
24 VDC +20%/-10% (including ripple), Class2/LPS |
||
Power consumption |
1680 mW*4excluding load current |
|||
Environmental resistance |
Ambient temperature |
−10°C to +55°C 14 to 131°F (no freezing)*5 |
||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Main unit: polycarbonate, FG terminal: copper/iron |
|||
Weight |
Approx. 42 g 1.48 oz |
|||
*1 Ensure the cable length is 30 m 98.4' or less (20 m 65.6' or less when using IO-Link) for the M12 connector type. | ||||

Specifications
Model |
AH-614A |
|||
Type |
Sensor head |
|||
Amplifier unit |
AS-421H |
|||
Shape |
Thin, 14 × 30 × 4.8 mm |
|||
Measuring range |
0 to 5 mm 0.20" |
|||
Analog output voltage |
Output voltage |
1.0 to 2.0V |
||
Straight line range |
1.0 to 2.0mm 0.039" to 0.079" |
|||
Impedance |
100 Ω |
|||
Resolution |
0.2% of F.S. |
|||
Linearity |
±2.0% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.06% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.1% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
6VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
― |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Weight |
Sensor head |
― |
||
Weight (including cord) |
Amplifier unit |
|||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-H156 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1560 mm 61.42" *3 |
|||
No. ofelectrodes |
36 |
|||
Static elimination bar length |
1520 mm 59.84" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1600 g 56.44 oz |
||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SV3-B075AK *1 |
|||
General specifications |
Applicable servo amplifier |
SV3-075L2 |
||
Rated output |
750 W |
|||
Rated torque |
2.39 N·m *2 |
|||
Instant maximum torque |
8.36 N·m |
|||
Rated current |
4.4 Arms |
|||
Instant maximum current |
16.9 Arms |
|||
Rated rotation speed |
3,000 min-1 |
|||
High rotation speed |
7,000 min-1 |
|||
Torque constant |
0.584 N·m/Arms |
|||
Rotor moment of inertia |
1.76 ×10-4 kg·m2 |
|||
Rated power rating |
32.4 kW/s |
|||
Rated angle acceleration |
13,500 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
26 bit |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20% to 80% RH (No condensation) |
|||
Operating atmosphere |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8 ft/s2 with servo motor flange surface as reference |
|||
Impact resistance |
490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: Class A, CE: Class B |
|||
Min. insulation resistance |
500 VDC 10 MΩ or more with insulation resistance meter |
|||
Isolation voltage tolerance |
1,500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
12×*3 |
|||
Approx. weight |
2.8 kg 6.17 lb |
|||
Electromagnetic brake specifications |
Capacity |
6.5 W |
||
Rated voltage |
24 VDC ±10% |
|||
Rated current (@20°C 68°F) |
0.27 A |
|||
Holding torque |
2.39 N·m |
|||
Release time |
80 ms |
|||
Operating time |
100 ms |
|||
*1 The open and operation times of the electromagnetic brake depend on the discharge circuit. | ||||

Specifications
Model |
PR-B01 |
|||
Type |
Flat bracket, standard type |
|||
Applicable product |
PR-F Series |
|||
Number included |
1 pcs. |
|||
Material |
SUS316L |
|||
Note |
M3 screw × 2 included |
|||
Weight |
Approx. 8 g |
|||



Specifications
Model |
IV4-G500CA |
|||
Type |
Standard model |
|||
Installed distance |
From 50 mm 1.97" |
|||
Field of view |
Installation distance of 50 mm 1.97": 22 (H) × 16 (V) mm to |
|||
Image receiving element |
Type |
1/2.9 inch color CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Focus adjustment |
Auto *1 |
|||
Exposure time |
12 μs to 9 ms *2 |
|||
Lights |
Illumination |
White LED |
||
Lighting method |
Switchable between pulse and continuous lighting |
|||
Indicators |
2 indicators (both displaying same content) |
|||
Power supply |
Average power consumption |
2.5 W (without AI imaging illumination unit installed) |
||
Environmental resistance |
Enclosure rating |
IP67 *3 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *4 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions |
|||
Material |
Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *5 |
|||
Weight |
Approx. 75 g 2.65 oz (no AI imaging illumination unit) |
|||
*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program. | ||||