Machine Vision Systems

5768 products

Showing 4369 - 4392 of 5768 products

Showing 4369 - 4392 of 5768 products
View
keyence Stock Image
Keyence OP-88455 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88455

Length

2 m 6.6'

Material

PUR

Weight

Approx. 80 g 2.82 oz

Keyence Stock Image
Keyence KV-NC32EXT Keyence
Sale price 17,686.00 kr
Only 8 units left

Specifications

Model

KV-NC32EXT

Expansion input unit

External connection method

Connector

Input Points

32

Input terminals

24 VDC mode

Maximum input voltage

26.4 VDC

Input rated voltage

24 VDC mode

3.6 mA

5 VDC mode

Minimum ON voltage

24 VDC mode

19 V

5 VDC mode

Maximum OFF current

24 VDC mode

1.5 mA

Maximum OFF voltage

Common method

32 points/1 common (2 terminals)*1

Input time constant (four-level switching)

Input time constant setting

OFF to ON: Typ.

25 μs : 10 μs
300 μs : 240 μs
1 ms : 1 ms
10ms : 10 ms

OFF to ON: Max.

25 μs : 50 μs
300 μs : 290 μs
1 ms : 1.2 ms
10ms : 11 ms

ON to OFF: Typ.

25 μs : 50 μs
300 μs : 280 μs
1 ms : 1 ms
10ms : 10 ms

ON to OFF: Max.

25 μs : 150 μs
300 μs : 390 μs
1 ms : 1.2 ms
10 ms : 11 ms

Input impedance

6.3 kΩ

Expansion output unit

Output Points

32

External connectionmethod

MOSFET (N-ch)
(with overcurrent protection function) *2

External connection method

Connector

Rated load

30 VDC 0.2 A *3

Leakage current (when output is OFF)

100 μA or less

Residual voltage (at ON)

0.6 VDC or less

Common method

32 points/1 common (2 terminals) *1

Response time

OFF to ON

100 μs or less (with a load of 1 mA or more)

ON to OFF

200 μs or less (with a load of 1 mA or more)

Internal current consumption

60 mA or less

Weight

Approx. 150 g

*1 The input COM and output COM terminals are independent.
*2 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common, until the cause of the problem is removed.
*3 Rated load of each common is 1.6 A.

keyence Stock Image
Keyence OP-88095 Keyence
Sale price 5,637.00 kr
Only 1 unit left

Specifications

Model

OP-88095

Type

Cable for Separate Amplifier Models: For Amplifier (Connector Type)

AC/DC

24 V DC

Cable end

M8 Wiring Harness

Length

2 m 6.56'

Weight

Approx. 55 g

Keyence Stock Image
Keyence KV-16RW Keyence
Sale price 4,678.00 kr
Only 7 units left
Buy the Keyence KV-16RW PLC Module - a programmable logic controller component from Keyence's industrial automation platform. Provides reliable process control, I/O interfacing, and communication capabilities for manufacturing and process systems. The Keyence KV-16RW is a direct drop-in replacement for existing PLC installations.
keyence Stock Image
Keyence GL-SP5P Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GL-SP5P

Type

Standard cable

Applicable product

GL-S Series main unit

Number included

1 (set includes transmitter and receiver)

Cable end

Main unit connection connector - Loose wires

Output

PNP

Number of core

6

Length

5 m 16.40'

Note

For use with wire synchronization and optical synchronization systems

Weight

260 g

keyence Stock Image
Keyence GS-MA9U Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-MA9U

Type

Coding level: High

Applicable model

High Holding force model GS-M9 Series

Keyence Stock Image
Keyence FD-XS20 Keyence
Sale price 10,356.00 kr
In stock, 12 units

Specifications

Model

FD-XS20

Supported pipe materials

Metal pipes, Plastic pipes (soft/hard) *1

Supported fluids

Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1

Supported fluid temperature

0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)

Clamp set model

Plastic pipe/tube attachment

FD-XC20R1, FD-XC20R2, FD-XC20R3, FD-XC20R4

Metal pipe attachment

FD-XC20M1, FD-XC20M2*2

Maximum rated flow rate

Outer diameter of pipe 3/8 " (9.53 mm) , ø 10 0.39 ", ø 10.5 0.41 ": 0 to 15.00 L/min
Outer diameter of pipe ø 12 0.47 ", 1/2 " (12.7 mm) , ø 13.8 0.54 ": 0 to 20.00 L/min

Zero cut flow rate

0.10 L/min (standard), 40 mL/min (high resolution*3)*4 (variable, default)

Display resolution

Instantaneous flow rate

0.001/0.01/0.1 L/min (standard), 0.1/1/10 mL/min (high resolution*3) (Displayed on controller)

Shot amount

0.001/0.01/0.1 L (standard), 0.001/0.01/0.1/1 mL (high resolution*3) (Displayed on controller)

Repeatability

Plastic pipe/tube attachment

Response time: 50 ms

F.S.

± 0.1 %*5*6

Instantaneous flow rate

Outer diameter of pipe 3/8 " (9.53 mm) , ø 10 0.39 ": ±15 mL/min
Outer diameter of pipe ø 12 0.47 ", 1/2 " (12.7 mm): ±20 mL/min*5*6

Response time: 500 ms

Outer diameter of pipe 3/8 " (9.53 mm) , ø 10 0.39 ": ±4.7 mL/min
Outer diameter of pipe ø 12 0.47 ", 1/2 " (12.7 mm): ±6.3 mL/min*5

Metal pipe attachment

Response time: 50 ms

F.S.

±0.15 %*5*6

Instantaneous flow rate

Outer diameter of pipe 3/8 " (9.53 mm) , ø 10 0.39 ", ø 10.5 0.41 ": ±23 mL/min
Outer diameter of pipe ø 12 0.47 ", 1/2 " (12.7 mm) , ø 13.8 0.54 ": ±30 mL/min*5*6

Response time: 500 ms

Outer diameter of pipe 3/8 " (9.53 mm) , ø 10 0.39 ", ø 10.5 0.41 ": ±7.2 mL/min
Outer diameter of pipe ø 12 0.47 ", 1/2 " (12.7 mm) , ø 13.8 0.54 ": ±9.5 mL/min*5

Hysteresis

Variable

Integrated unit display

0.01/0.1/1/10/100 L (standard), 0.1/1/10/100/1000/10000 mL (high resolution*3) (displayed on controller)

Display method

Status indicator

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529) , IP68G (JIS C0920) *7

Ambient temperature

-10 to 60 °C (No freezing) 14 to 140 °F

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

50 G 11 ms 3 times each for X,Y,Z direction

Material

Sensor head

Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM

Clamp set

For plastic pipe

Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7

For metal pipe

Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7

Weight

Approx. 260 g

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1: approx. 0.5 mm 0.02", FD-XS8: approx. 1 mm 0.04", FD-XS20: approx. 1 0.04" to 2 mm 0.08". FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 Only controllers with serial numbers beginning with “G” (FD-XA1/XA2/XA5) are supported.
*4 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*5 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range.
*6 The longer the response time is set, the more repeatability is improved. As a guideline, use √ (50 ms/response time) times.
*7 The connector part of the sensor head cable is IP65/IP67.

Keyence Stock Image
Keyence CV-5001P Keyence
Sale price 24,813.00 kr
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence OP-88680 Keyence
Sale price 4,250.00 kr
Only 10 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-87422 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-87422

Power supply

Power voltage

24 to 36 V DC ± 10%

Power consumption

40 mA (at 24 V)/50 mA (at 36 V)

Environmental resistance

Ambient temperature

0 to 50°C

Relative humidity

30 to 80% RH (No condensation)

Weight

60 g

keyence Stock Image
Keyence CA-LH75 Keyence
Sale price 7,933.00 kr
Only 3 units left

Specifications

Model

CA-LH75

Focal point

75 mm 2.95"

F-stop range (aperture)

F2.5 to F22

Minimum WD

1.2 m 3.9'

Mount

C-mount

Filter size

34.0 mm 1.34" P0.5

Compatible image sensor size

2/3"

TV distortion

-0.1 % (-0.05 %)*1

Resolving power

100 cycles/mm at center, 80 cycles/mm on periphery

Ambient temperature/humidity range

0 to +50°C 32 to 122°F, 80% RH or less (No condensation)

Weight

Approx. 105 g

*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size.

keyence Stock Image
Keyence OP-88675 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence OP-87910 Keyence
Sale price 1,825.00 kr
Only 6 units left

Specifications

Model

OP-87910

Type

Adjustable bracket

Weight

Approx. 75 g

Keyence New Stock Image
Keyence LV-H42 Keyence
Sale price 3,490.00 kr
Only 5 units left

Specifications

Model

LV-H42

Type

Long-distance area

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

250 mm 9.84"

TURBO

500 mm 19.69"

SUPER

1000 mm 39.37"

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Case

Glass reinforced plastic

Lens cover

Polyarylate

Weight

Approx. 45 g

Keyence Stock Image
Keyence AI-H050 Keyence
Sale price 12,670.00 kr
Only 6 units left

Specifications

Model

AI-H050

Installation Distance

45 to 55 mm 1.77 to 2.17"

Detection Area

1X Zoom to 4X Zoom

4 × 4 mm 0.16 × 0.16" to 16 × 16 mm 0.63 × 0.63"*1

Digital Zoom

1X to 4X (17 steps) adjustment, zoom position adjustment*1

Light Receiving Element

BW CMOS

Transmitter

Light Source

Red LED (660 nm)

Lighting Method

Pulse lighting

Indicators

1 (green/red/orange)

Environmental resistance

Enclosure rating

IP67*2

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of 6 directions

Materials

Main unit case: Zinc die-cast/PBT; Front cover: Acrylic (hard coat); Cable: PVC
Operation indicator: PPSU; Polarized filter case: POM

Weight

Approx. 70 g (including polarized filter)

*1 When positioned in the midpoint of the installation distance range.
*2 Except when polarized filters or dome filters are mounted.

keyence Stock Image
Keyence OP-88202 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence EM-054B Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

EM-054B*1

Type

Shielded

Shape

5.4 mm 0.21" dia Cylindrical.

Detecting distance

1.2 mm 0.05" ±10%

Detectable object

Ferrous metals (see Characteristics for non-ferrous metals)

Standard target
(iron, t=1 mm 0.04")

6 x 6 mm 0.24"

Hysteresis

10% max. of detecting distance

Response frequency

1.2 kHz

Operation mode

N.O.

Temperature characteristics

±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F

Display indicator

Red LED

Control output

NPN: 200 mA (40 V) max., Residual voltage: 1 V max.

Housing

Stainless steel

Rating

Power voltage

10.8 to 30 VDC, Ripple (P-P) 10 % or less*2

Current consumption

12 mA or less

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +80 °C -13 to 176 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Weight

Approx. 40 g (including nuts and 2-m 6.6' cable)

*1 The alternative-frequency type of EM-054
*2 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects.

keyence Stock Image
Keyence LV-22P Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence DX-OCR1 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SJ-E204A Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-E204A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

2100 mm 82.68"*3

Total length

2000 mm 78.74"

No. ofelectrodes

33

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2100 g 74.08oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence XC-T34E2 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

XC-T34E2

Rated voltage

125 VAC/DC

Rated current

1 A/pin

Ambient operating temperature

−40 to +80°C −40 to +176°F

Screw torque

0.5 N·m (max.)

Applicable wire diameter

AWG24 to 12

Environmental resistance

Insulation resistance

500 VDC, 500 MΩ or greater

Withstand voltage

500 VAC, 1 minute, 1 mA or less

keyence Stock Image
Keyence OP-88418 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence FU-93 Keyence
Sale price 11,245.00 kr
Only 5 units left

Specifications

Model

FU-93

Type

Reflective model fiber unit

Detecting method

Wetted type

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.3×2

Minimum bend radius

Fluorocarbon polymer part : R40 mm1.575"*1 fiber part : R25

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 78 g

*1 The section 80 mm in length from the tip cannot be bent.

keyence Stock Image
Keyence OP-88917 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed