Specifications
Model |
OP-88551 |
|||
Type |
Sensor head to amplifier cable |
|||
Length |
20 m 65.6' |
|||
Weight |
Approx. 760 g |
|||

Specifications
Model |
NQ-EP4L |
|||
Network Specifications |
Compatible Networks |
EtherNet/IP™, Modbus/TCP |
||
Communication Speed |
10 Mbps/100 Mbps |
|||
Connector |
M8 4-pin female A-code |
|||
Power Supply Specifications |
Connector Type |
Power supply port IN: M8 4-pin male A-code |
||
Power Voltage |
18 to 30 VDC |
|||
Allowable Current |
V1 and V2: max. 4 A each |
|||
Current Consumption |
V1: max. 110 mA |
|||
Sensor Connection Specifications |
Connector Type |
M12 5-pin female A-code |
||
V1 Power Supply Capacity |
- |
|||
V2 Power Supply Capacity |
Ports 1 to 4: 4 A in total |
|||
IO-Link Specifications |
Number of Connectable Devices |
4 |
||
Compliant Standards |
Ver1.1 |
|||
Transmission Speed |
COM1: 4.8 kbps |
|||
Port type |
Ports 1 to 4: Class A*1 |
|||
Process Data Size |
Input: Max. 32 bytes/Output: Max. 32 bytes |
|||
Digital Input (DI) Specifications |
Number of Inputs |
Max. 8 (when using DI mode) |
||
Input Type |
PNP |
|||
ON Voltage/ON Current |
11 V or higher/2 mA or higher |
|||
OFF Voltage/OFF Current |
Less than 5 V/less than 1.5 mA |
|||
Input Current |
Pin 2: approx. 7 mA, Pin 4: approx. 12 mA |
|||
Digital Output (DO) Specifications |
Number of Outputs |
Max. 4 |
||
Output Type |
PNP |
|||
Maximum Load Current |
Each port max. 0.5 A |
|||
Short-Circuit Protection Circuit |
Yes |
|||
Leakage Current |
0.1 mA or lower |
|||
Residual Voltage |
1 V or lower |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67/IP69K |
||
Ambient temperature |
-40°C to +70°C -40°F to +158°F (no freezing) |
|||
Vibration resistance |
5 to 150 Hz/20 G/10 sweeps each in X, Y, and Z axes |
|||
Shock resistance |
15 G/11 ms/3 times each in X, Y, and Z axes |
|||
Case Material |
Housing: PA6-GF30 |
|||
Weight |
Approx. 190 g 6.70 oz |
|||
*1 When using Class B, V1 and V2 each require a power supply. | ||||

Specifications
Model |
LV-S62 |
|||
Type |
Parallel light area |
|||
FDA (CDRH) Part 1040.10 |
Class 1 Laser Product |
|||
IEC 60825-1 | ||||
Light source |
Visible red semiconductor laser, Wavelength: 660 nm |
|||
Detecting |
MEGA |
12 m (6 m) 39.4' (19.7')*1 |
||
ULTRA |
10 m (5 m) 32.8' (16.4')*1 |
|||
SUPER |
8 m (3.5 m) 26.2' (11.5')*1 |
|||
TURBO |
5 m (2 m) 16.4' (6.6')*1 |
|||
FINE |
2.5 m (0.7 m) 8.2' (2.3')*1 |
|||
HSP |
- |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Acrylic |
|||
Reflective mirror |
Polycarbonate, acrylic |
|||
Weight |
Approx. 65 g |
|||
*1 Numbers enclosed in parentheses are the detecting distance for small beam spot. | ||||

Specifications
Model |
GV-H45L |
|||
Type |
Short-range |
|||
Light source |
Visible semiconductor laser, Wavelength: 655 nm |
|||
Laser class |
FDA (CDRH) |
Class 1*1 (220 µW) |
||
IEC 60825-1 |
Class 1 (220 µW) |
|||
JIS C6802 | ||||
Detection distance |
20 to 45 mm 0.79" to 1.77" |
|||
Possible display range |
259 to -34 |
|||
Standard detection deviation |
0.5 mm 0.02" |
|||
Spot diameter |
Approx. ø0.1 mm ø0.004" |
|||
Operation status indicators |
Control output: Red LED/Laser radiation emission indicator: Green LED/1 spot indicator: Green LED |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Operating ambientluminance |
Incandescent lamp |
5000ℓx |
||
Sunlight |
10000ℓx |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing material: PBT, Display: Polyarylate, Metal: SUS304, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 120 g*3 |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice. | ||||

Specifications
Model |
FI-CF4 |
|||
Type |
Pipe type |
|||
Main unit |
FI-C40F |
|||
Detection principle |
Refractive index (surface light source) |
|||
Rated concentration range |
Brix: 0–40% (nD: 1.32500–1.41000) |
|||
Display method |
Status indicator light |
|||
Display range |
Brix: 0–50% |
|||
Supported fluids |
Non-corrosive aqueous solutions (such as water-soluble coolants, mold release agents, etc.)*1 |
|||
Supported fluid temperature |
0–70°C 32–158°F (no freezing) |
|||
Connection diameter |
NPT1 1/2 |
|||
Rated pressure range |
1.0 MPa or less |
|||
Pressure resistance |
2.0 MPa |
|||
Display resolution |
Brix: 0.01/0.1% (default value: 0.1) |
|||
Response time |
1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s |
|||
Measurement accuracy |
Brix: ±0.2%*2*3 (nD: ±0.0003) |
|||
Concentration unit |
Brix nD*4 |
|||
Temperature measurement accuracy |
±1.0°C 1.8°F*2 |
|||
Power supply |
Current consumption |
25 mA or less |
||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
–10 to +60°C 14 to +140°F (no freezing) |
|||
Relative humidity |
35–85% RH (no condensation) |
|||
Vibration resistance |
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Material |
Liquid end materials |
Body: SCS16A; Gasket: FKM |
||
Other materials |
Body: SUS304; PPS indicator light: PPSU / TPU / PBT |
|||
Weight |
Approx. 1360 g 47.97 oz |
|||
*1 Use water as the solvent, and use materials that are soluble in water. If the particles are not water soluble, such as with slurry, the refractive index may not change. | ||||

Specifications
Model |
NE-Q05 |
|||
General specifications |
Current consumption. |
180 mA |
||
Power voltage |
24 VDC ± 10% |
|||
Operating ambient temperature |
0 to +50°C 32 to 122°F *1 (no freezing) |
|||
Operating ambient humidity |
10 to 95%RH (no condensation) |
|||
Storage ambient temperature |
-20 to +70°C -4 to 158°F |
|||
Operating environment |
Minimal amount of dust and corrosive gas present |
|||
Operating altitude |
2000m or less |
|||
Noise immunity |
1,500 Vp-p, pulse width: 1 µs, 50 ns (by way of a noise simulator) |
|||
Withstand voltage |
1,500 VAC for 1 minute between the power supply terminal and the communication terminal and between all the external terminals and the case |
|||
Insulation resistance |
50 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and the communication terminal and between all the external terminals and the case) |
|||
Shock resistance |
Acceleration: 150 m/s2, operating time: 11 ms, 2 times in each of the X, Y, and Z directions |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Intermittent vibration |
Frequency: 10 to 57 Hz |
Amplitude: 0.075 mm*2 |
|
Frequency: 57 to 150 Hz |
Acceleration: 9.8 m/s2*2 |
|||
Continuous vibration |
Frequency: 10 to 57 Hz |
Amplitude: 0.035 mm*2 |
||
Frequency: 57 to 150 Hz |
Acceleration: 4.9 m/s2*2 |
|||
Weight |
Approx 180g |
|||
Function/performance specifications |
Data transfer speed |
10 Mbps, 100 Mbps, automatic support for full duplex and half duplex modes |
||
MDI/MDI-X automatic switching function |
Provided |
|||
Auto-negotiation function | ||||
Communicationspecifications |
MAC address retention |
300 s |
||
Function/performance specifications |
Upper limit for the number of MAC addresses that can be registered |
2048 |
||
QoS function |
Priority control of EtherNet/IP™ cyclic data |
|||
PoE function |
None |
|||
Communicationspecifications |
Switching type |
Store and forward method |
||
Metal cable |
Flow control |
Half duplex: back pressure, full duplex: conforms to IEEE802.3x; pose packets are used to perform flow control |
||
*1 This is regulated according to the temperature below the control panel unit. | ||||

Specifications
Model |
FU-77TG*1 |
|||
Optical axis diameter |
ø1.13 mm 0.04" |
|||
Size |
M4 |
|||
Fibre unit length |
1 m 3.28', cut not allowed. |
|||
Shape |
Hex-shaped |
|||
Minimum bend radius |
R10 mm R0.39", Stainless Steel |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 43 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
CA-LMH15*1 |
|||
Optical magnification |
x1.5 |
|||
Shape |
Standard |
|||
Compatible image sensor size |
2/3" |
|||
Field of view (at reference magnification) |
1/3": 2.4 × 3.2 mm 0.09" × 0.13" |
|||
F-stop range (aperture) |
11.9 |
|||
Ambient temperature/humidity range |
0 to 50°C 32 to 122°F, 35 to 80% RH (no condensation) |
|||
WD |
110.0 mm 4.33"*2 |
|||
TV distortion |
0.00% (2/3") |
|||
Depth-of-field |
0.4 mm 0.02"*3 |
|||
Mount |
C-mount |
|||
Resolution |
5.3 µm 0.21 Mil*4 |
|||
Weight |
Approx. 110 g |
|||
*1 Depending on factors such as the installation orientation and the vibrations of the environment, consider reinforcing the installation such as by implementing countermeasures to hold the lens in place. For information on the locations to hold the lens in place, see the installation examples. | ||||

Specifications
Model |
FD-ECH10 |
|||
Pipe size |
Outer diameter of pipe |
ø10 0.39" |
||
Installable range |
10.0 0.39" |
|||
Pipe materials |
Polyurethane, nylon, PFA,*1 other*2 |
|||
Supported gases |
Air, nitrogen, argon, and other gases*3 |
|||
Supported gas temperature |
−10°C to +60°C 14 to 140°F |
|||
Operating pressure range |
0 to 0.75 MPa (upper limit depends on pipe specifications) |
|||
Flow rate detection principle |
Ultrasonic transmission time difference method |
|||
Rated flow rate |
(volume flow rate) |
120 L/min 4.24 CFM * Initial display |
||
(20°C 68°F, atmospheric pressure conversion) |
Gas at 20°C 68°F, 0.2 MPa |
360 L/min |
||
Gas at 20°C 68°F, 0.4 MPa |
600 L/min |
|||
Gas at 20°C 68°F, 0.6 MPa |
840 L/min |
|||
Repeatability |
Response time 250 ms: ±2.5% of F.S.*4*5 |
|||
Display resolution |
Instantaneous flow |
0.1/1 L/min |
||
Accumulated flow |
0.1/1/10/100/1000 L |
|||
Display method |
Output indicator |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Ambient temperature |
−10°C to +60°C 14 to 140°F (no freezing) |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Sensor unit |
PBT/PAR/iron |
||
Sensor surface |
Special rubber |
|||
Weight |
Approx. 114 g |
|||
*1 Use PFA tubes in an environment with a temperature of 40°C 104°F or less. | ||||

Specifications
Model |
BT-WUC84GA |
|||
Dedicated AC adapter specifications |
Input side |
100 to 240 VAC, 50/60 Hz |
||
Output side |
16 VDC, Max. 3.75 A |
|||
Dimensions |
Dedicated AC adapter specifications |
102.5 x 42.5 x 28 mm 4.04" x 1.67" x 1.1" |
||
Weight |
Approx. 250 g |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F (No freezing) |
||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +60 °C -4 to 140 °F (No freezing) |
|||
Storage relative humidity |
20 to 85 % RH (No condensation) |
|||
Accessory |
AC adapter (OP-88149)*1 |
|||
Dimensions |
93.6 × 97.1 × 327 mm |
|||
Weight |
Approx. 785 g |
|||
*1 A separate AC cable is required. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
ER-NH028 |
|||
Cable |
Standard |
|||
Stable detection range |
0 to 0.6 mm |
|||
Maximum operating distance |
1.2 mm 0.05" *1 *3 |
|||
Hysteresis distance |
Adjustable |
|||
Repeatability |
1 μm 0.04 Mil *1 *4 |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
5 × 5 mm 0.20" × 0.20" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F) |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60°C 14°F to 140°F (no freezing) |
|||
Relative humidity |
Up to 85% RH (No condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detection surface |
Epoxy resin |
||
Case |
SUS304 |
|||
Cable |
PVC |
|||
Sensor head connector |
PA66, polycarbonate |
|||
Accessories |
― |
|||
Accessories | ||||
Weight |
Approx. 30 g |
|||
*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object. | ||||


Specifications
Model |
SH-303A |
|||
Type |
Standard Shielded Cylindrical |
|||
Shape |
ø3.8×18 Cylindrical |
|||
Detectable object |
Ferrous metal (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
5 x 5 mm 0.20"*1 |
|||
Stable detecting range |
0 to 0.8 mm 0.03" |
|||
Maximum detecting distance |
2 mm 0.08" |
|||
Repeatability |
0.001 mm 0.00004"*1 |
|||
Hysteresis |
0.05 mm 0.002"*1 |
|||
Temperature characteristics |
0.3%/°C*1 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 35 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||


Specifications
Model |
VT-PW10N |
|||
Type |
10" widescreen protective sheet |
|||
Applicable product |
for VT5-W10 |
|||
Number included |
Set of 5 sheets |
|||
Note |
white, without logo |
|||

Specifications
Model |
FD-ECH6 |
|||
Pipe size |
Outer diameter of pipe |
ø6 0.24" |
||
Installable range |
6.0 0.24" |
|||
Pipe materials |
Polyurethane, nylon, PFA,*1 other*2 |
|||
Supported gases |
Air, nitrogen, argon, and other gases*3 |
|||
Supported gas temperature |
−10°C to +60°C 14 to 140°F |
|||
Operating pressure range |
0 to 0.75 MPa (upper limit depends on pipe specifications) |
|||
Flow rate detection principle |
Ultrasonic transmission time difference method |
|||
Rated flow rate |
(volume flow rate) |
40 L/min 1.41 CFM * Initial display |
||
(20°C 68°F, atmospheric pressure conversion) |
Gas at 20°C 68°F, 0.2 MPa |
120 L/min |
||
Gas at 20°C 68°F, 0.4 MPa |
200 L/min |
|||
Gas at 20°C 68°F, 0.6 MPa |
280 L/min |
|||
Repeatability |
Response time 250 ms: ±2.5% of F.S.*4*5 |
|||
Display resolution |
Instantaneous flow |
0.01/0.1/1 L/min |
||
Accumulated flow |
0.01/0.1/1/10/100 L |
|||
Display method |
Output indicator |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Ambient temperature |
−10°C to +60°C 14 to 140°F (no freezing) |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Sensor unit |
PBT/PAR/iron |
||
Sensor surface |
Special rubber |
|||
Weight |
Approx. 102 g |
|||
*1 Use PFA tubes in an environment with a temperature of 40°C 104°F or less. | ||||


Specifications
Model |
OP-88996 |
|||
Type |
Connection Cable |
|||
Cable end |
M12 female 8-pin - M12 male 5-pin |
|||
Length |
10 m 32.8' |
|||
Material |
cable: Chemical-resistant PVC |
|||


Specifications
Model |
EM-014P |
|||
Type |
Shielded |
|||
Shape |
M14 Threaded |
|||
Detecting distance |
4.0 mm 0.16" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
15 x 15 mm 0.59" x 0.59" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Output |
PNP |
|||
Control output |
PNP: 200 mA (30 V) max., Residual voltage: 1 V max. |
|||
Housing |
Cr-plated brass |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*1 |
||
Current consumption |
20 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 60 g (including nuts and 2-m 6.6' cable) |
|||
*1 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.