Contactors

9841 products

Showing 25 - 48 of 9841 products

Showing 25 - 48 of 9841 products
View
LC1D09BD Schneider Electric
Schneider LC1D09BD Schneider Electric
Sale price 1,168.00 kr
Only 8 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 415...440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415...440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phase motors
2 hp at 230/240 V AC 50/60 Hz for 3 phase motors
5 hp at 460/480 V AC 50/60 Hz for 3 phase motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 25 A (at 140 °F (60 °C)) for power circuit
10 A (at 140 °F (60 °C)) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s for power circuit
210 A 104 °F (40 °C) - 1 s for power circuit
30 A 104 °F (40 °C) - 10 min for power circuit
61 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole 1.56 W AC-1
0.2 W AC-3
0.2 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 0.6 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 9 A AC-3 <= 440 V
2 Mcycles 9 A AC-3e <= 440 V
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.25 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.7...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W 5.4 W 68 °F (20 °C))
Hold-in power consumption in W 5.4 W 68 °F (20 °C)
Operating time 63 ±15 % ms closing
20 ±20 % ms opening
Time constant 28 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
Siemens New Stock Image
Siemens 3RT1054-1AF36 Siemens
Sale price 3,280.00 kr
Only 5 units left
Product
Article Number (Market Facing Number) 3RT10541AF36 | 3RT10541AF36
Product Description power contactor, AC-3e/AC-3 115 A, 55 kW / 400 V, AC (50-60 Hz) / DC Uc: 110-127 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: box terminal control and auxiliary circuit: screw terminal
Product family SIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209504455
UPC 754554766317
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3706
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 8.091 lb
Package size unit of measure in
Packaging Quantity 1
Siemens New Stock Image
Siemens 3RT6026-1AG20 Siemens
Sale price 730.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

LC1D18BD Schneider Electric
Schneider LC1D18BD Schneider Electric
Sale price 1,068.00 kr
Only 9 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3/3e (7.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.08 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 18 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
32 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
18 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Motor power kW 4 kW at 220...230 V AC 50/60 Hz (AC-3)
7.5 kW at 380...400 V AC 50/60 Hz (AC-3)
9 kW at 415...440 V AC 50/60 Hz (AC-3)
10 kW at 500 V AC 50/60 Hz (AC-3)
10 kW at 660...690 V AC 50/60 Hz (AC-3)
4 kW at 400 V AC 50/60 Hz (AC-4)
4 kW at 220...230 V AC 50/60 Hz (AC-3e)
7.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
9 kW at 415...440 V AC 50/60 Hz (AC-3e)
10 kW at 500 V AC 50/60 Hz (AC-3e)
10 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 1 hp at 115 V AC 50/60 Hz for 1 phase motors
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
5 hp at 230/240 V AC 50/60 Hz for 3 phase motors
10 hp at 460/480 V AC 50/60 Hz for 3 phase motors
15 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
32 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 145 A 104 °F (40 °C) - 10 s for power circuit
240 A 104 °F (40 °C) - 1 s for power circuit
40 A 104 °F (40 °C) - 10 min for power circuit
84 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 32 A 50 Hz for power circuit
Power dissipation per pole 2.5 W AC-1
0.8 W AC-3
0.8 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 1.65 Mcycles 18 A AC-3 <= 440 V
1 Mcycles 32 A AC-1 <= 440 V
1.65 Mcycles 18 A AC-3e <= 440 V
Control circuit type DC standard
Coil technology With integral suppression device
Control circuit voltage limits 0.1...0.25 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.7...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W 5.4 W 68 °F (20 °C))
Hold-in power consumption in W 5.4 W 68 °F (20 °C)
Operating time 63 ±15 % ms closing
20 ±20 % ms opening
Time constant 28 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: solid without cable end
Tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
LC1D150BD Schneider Electric
Schneider LC1D150BD Schneider Electric
Sale price 3,491.00 kr
Only 7 units left

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V DC standard coil

LC1F225 Schneider Electric
Schneider LC1F225 Schneider Electric
Sale price 10,059.00 kr
Only 4 units left

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 225A without coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100380V DC

LC1D12BL Schneider Electric
Schneider LC1D12BL Schneider Electric
Sale price 980.00 kr
Only 10 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (5.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a low consumptioon 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.07 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-3
AC-1
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Motor power kW 3 kW at 220...230 V AC 50/60 Hz (AC-3)
5.5 kW at 380...400 V AC 50/60 Hz (AC-3)
5.5 kW at 415...440 V AC 50/60 Hz (AC-3)
7.5 kW at 500 V AC 50/60 Hz (AC-3)
7.5 kW at 660...690 V AC 50/60 Hz (AC-3)
3.7 kW at 400 V AC 50/60 Hz (AC-4)
3 kW at 220...230 V AC 50/60 Hz (AC-3e)
5.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
5.5 kW at 415...440 V AC 50/60 Hz (AC-3e)
7.5 kW at 500 V AC 50/60 Hz (AC-3e)
7.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phase motors
3 hp at 230/240 V AC 50/60 Hz for 3 phase motors
7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors
10 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 25 A (at 140 °F (60 °C)) for power circuit
10 A (at 140 °F (60 °C)) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s for power circuit
210 A 104 °F (40 °C) - 1 s for power circuit
30 A 104 °F (40 °C) - 10 min for power circuit
61 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole 0.36 W AC-3
1.56 W AC-1
0.36 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 2 Mcycles 12 A AC-3 <= 440 V
0.8 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 12 A AC-3e <= 440 V
Control circuit type DC low consumption
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.8...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W 2.4 W 68 °F (20 °C))
Hold-in power consumption in W 2.4 W 68 °F (20 °C)
Operating time 77 ±15 % ms closing
25 ±20 % ms opening
Time constant 40 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
LC1D25BD Schneider Electric
Schneider LC1D25BD Schneider Electric
Sale price 1,059.00 kr
Only 7 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 25A/690V AC-3/3e (11kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 60A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.82 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-3
AC-1
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 25 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
40 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
25 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Motor power kW 5.5 kW at 220...230 V AC 50/60 Hz (AC-3)
11 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 415...440 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3)
15 kW at 660...690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
5.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
11 kW at 380...400 V AC 50/60 Hz (AC-3e)
11 kW at 415...440 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3e)
15 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 115 V AC 50/60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors
15 hp at 460/480 V AC 50/60 Hz for 3 phase motors
20 hp at 575/600 V AC 50/60 Hz for 3 phase motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
40 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 240 A 104 °F (40 °C) - 10 s for power circuit
380 A 104 °F (40 °C) - 1 s for power circuit
50 A 104 °F (40 °C) - 10 min for power circuit
120 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
Power dissipation per pole 3.2 W AC-1
1.25 W AC-3
1.25 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 1.65 Mcycles 25 A AC-3 <= 440 V
1.4 Mcycles 40 A AC-1 <= 440 V
1.65 Mcycles 25 A AC-3e <= 440 V
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.25 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.7...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W 5.4 W 68 °F (20 °C))
Hold-in power consumption in W 5.4 W 68 °F (20 °C)
Operating time 63 ±15 % ms closing
20 ±20 % ms opening
Time constant 28 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.02 in² (1…10 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
LC1D80P7 Schneider Electric
Schneider LC1D80P7 Schneider Electric
Sale price 1,239.00 kr
Only 9 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 80A/1000V AC-3/AC-3e (37kW@400V). They can be used to create motor starters for almost any type of application. It provides a 230V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-3e
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit <= 300 V DC 25...400 Hz
Power circuit <= 690 V AC
[Ie] rated operational current 125 A (at <140 °F (60 °C)) at <= 1000 V AC AC-1 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 230 V AC 50/60 Hz

Complementary

Characteristic Value(s)
Motor power kW 22 kW at 220...230 V AC 50 Hz (AC-3)
37 kW at 380...400 V AC 50 Hz (AC-3)
45 kW at 415...440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660...690 V AC 50 Hz (AC-3)
15 kW at 400 V AC 50 Hz (AC-4)
22 kW at 220...230 V AC 50/60 Hz (AC-3e)
37 kW at 380...400 V AC 50/60 Hz (AC-3e)
45 kW at 415...440 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors
30 hp at 230/240 V AC 50/60 Hz for 3 phase motors
60 hp at 460/480 V AC 50/60 Hz for 3 phase motors
60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 104 °F (40 °C) - 10 s for power circuit
990 A 104 °F (40 °C) - 1 s for power circuit
135 A 104 °F (40 °C) - 10 min for power circuit
320 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 5.1 W AC-3
12.5 W AC-1
5.1 W AC-3e
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 0.8 Mcycles 125 A AC-1 <= 440 V
1.5 Mcycles 80 A AC-3 <= 440 V
1.5 Mcycles 80 A AC-3e <= 440 V
Control circuit type AC 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 60 Hz
0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz
1...1.1 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20...35 ms closing
6...20 ms opening
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end
Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Rail
Plate
LC1F800 Schneider Electric
Schneider LC1F800 Schneider Electric
Sale price 60,273.00 kr
Only 5 units left

TeSys F contactor, 3 poles (3NO), 800A/1000V AC-3, for motor applications up to 450kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 600 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
product name TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-1
AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 1000 A 104 °F (40 °C)) <= 440 V AC AC-1
800 A 131 °F (55 °C)) <= 440 V AC AC-3
Motor power kW 450 kW at 1000 V AC 50/60 Hz (AC-3)
450 kW at 500 V AC 50/60 Hz (AC-3)
475 kW at 660...690 V AC 50/60 Hz (AC-3)
110 kW at 400 V AC 50/60 Hz (AC-4)
450 kW at 380...400 V AC 50/60 Hz (AC-3)
450 kW at 415 V AC 50/60 Hz (AC-3)
450 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 220...240 V AC 50/60 Hz (AC-3)

Complementary

Characteristic Value(s)
[Uc] control circuit voltage 110...400 V AC 40...400 Hz with LX1/LX9 coil
110...400 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 1000 A (at 104 °F (40 °C))
Irms rated making capacity 8000 A AC conforming to IEC 60947-4-1
Rated breaking capacity 6400 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 2600 A 104 °F (40 °C) - 3 min
5500 A 104 °F (40 °C) - 10 s
4600 A 104 °F (40 °C) - 30 s
3600 A 104 °F (40 °C) - 1 min
1700 A 104 °F (40 °C) - 10 min
Associated fuse rating 1000 A gG at <= 440 V
800 A aM at <= 440 V
Average impedance 0.12 mOhm - Ith 1000 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 120 W AC-1
77 W AC-3
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.3...0.5 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
Heat dissipation 25 W
2.2…5.5 W
Operating time 60...80 ms closing with LX1/LX9 coil
160...180 ms opening with LX1/LX9 coil
60...80 ms closing with LX4 coil
40...50 ms opening with LX4 coil
40...80 ms closing with LXE coil
6...54 ms opening with LXE coil
Mounting Support Plate
Standards IEC 60947-1
JIS C8201-4-1
EN 60947-1
IEC 60947-4-1
EN 60947-4-1
Product Certifications CB
CSA
LROS (Lloyds register of shipping)
ABS
CCC
UL
UKCA
Connections - terminals Power circuit bar 2 60 x 5 mm
Power circuit bolted connection
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)
Tightening torque Power circuit 513.3 lbf.in (58 N.m)
Control circuit 10.6 lbf.in (1.2 N.m)
Mechanical durability 5 Mcycles
Inrush power in VA 1700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil
1900 VA (at 68 °F (20 °C))with LX4 coil
460…730 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil
500…680 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil
Hold-in power consumption in VA 12 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil
12 VA (at 68 °F (20 °C))with LX4 coil
7…10 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil
4.0…5.5 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil
Maximum operating rate 600 cyc/h 131 °F (55 °C)
Compatibility code LC1F
3RT2026-1AK60 Siemens
Siemens 3RT2026-1AK60 Siemens
Sale price 1,142.00 kr
Only 6 units left
Product
Article Number (Market Facing Number) 3RT20261AK60 | 3RT20261AK60
Product Description power contactor, AC-3e/AC-3, 25 A, 11 kW / 400 V, 3-pole, 110 V AC, 50 Hz / 120 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S0
Product family SIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209832923
UPC 040892547597
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5336
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.924 lb
Package size unit of measure in
Packaging Quantity 1
LC1D65ABD Schneider Electric
Schneider LC1D65ABD Schneider Electric
Sale price 1,835.00 kr
Only 10 units left

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 24 V DC standard coil

1SBL407001R1300 ABB - AF96-30-00-13
ABB 1SBL407001R1300 ABB - AF96-30-00-13
Sale price 2,549.00 kr
Only 8 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
116 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.17 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 130 A
(690 V) 60 °C 105 A
(690 V) 70 °C 90 A
(690 V) 40 °C 130 A
(690 V) 60 °C 105 A
(690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 96 A
(440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(1000 V) 60 °C 30 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
(415 V) 60 °C 96 A
(440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(1000 V) 60 °C 30 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 96 A
(440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
(415 V) 60 °C 96 A
(440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
(72 V) 1-Pole, 60 °C 105 A
(72 V) 1-Pole, 70 °C 90 A
(72 V) 2 Poles in Series, 40 °C 130 A
(72 V) 2 Poles in Series, 60 °C 105 A
(72 V) 2 Poles in Series, 70 °C 90 A
(72 V) 3 Poles in Series, 40 °C 130 A
(72 V) 3 Poles in Series, 60 °C 105 A
(72 V) 3 Poles in Series, 70 °C 90 A
(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 130 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
(72 V) 1-Pole, 60 °C 105 A
(72 V) 1-Pole, 70 °C 90 A
(72 V) 2 Poles in Series, 40 °C 130 A
(72 V) 2 Poles in Series, 60 °C 105 A
(72 V) 2 Poles in Series, 70 °C 90 A
(72 V) 3 Poles in Series, 40 °C 130 A
(72 V) 3 Poles in Series, 60 °C 105 A
(72 V) 3 Poles in Series, 70 °C 90 A
(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 130 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 130 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
(72 V) 1-Pole, 60 °C 105 A
(72 V) 1-Pole, 70 °C 90 A
(72 V) 2 Poles in Series, 40 °C 130 A
(72 V) 2 Poles in Series, 60 °C 105 A
(72 V) 2 Poles in Series, 70 °C 90 A
(72 V) 3 Poles in Series, 40 °C 130 A
(72 V) 3 Poles in Series, 60 °C 105 A
(72 V) 3 Poles in Series, 70 °C 90 A
(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 130 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
Rated Operational Power AC-3 (Pe):
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(1000 V) 40 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(1000 V) 40 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe):
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 8.2 W
at Rated Operating Conditions AC-3 per Pole 4.5 W
at Rated Operating Conditions AC-1 per Pole 8.2 W
at Rated Operating Conditions AC-3 per Pole 4.5 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 17 mm
Control Circuit 10 mm
Main Circuit 17 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 115 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(240 V AC) Single Phase 20 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 75 hp
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(240 V AC) Single Phase 20 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 92 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 88 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 92 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 88 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
81df14b5-edb5-40f5-8e35-b316e417bef9 France
Simplified SCIP:
fb3f596b-c8fe-49cb-9b4f-a30aed5aed28 Germany
f6d20ef4-4758-4a2b-9a84-7716191b9c37 Denmark
e1ef6c99-d62f-43e1-9fc1-83a6eb57b5a4 Czech Republic
692bc6cd-cc1f-40a3-9531-fcfd06075411 Germany
23fdf834-6560-4f22-9e99-6761a9d53fff Finland
123bc802-adcb-4fc9-8bb4-2d7dd8d92aed Italy
9206bd31-7c96-4f2e-a972-ea0bbbad9180 Germany
945a6df2-f86c-4a43-8f63-468ff61ab31f Spain
76aeb018-b24a-43f1-b0c9-4bf7423d9cef Portugal
06dd8d63-c226-4ebe-ac4f-bbcfd9d062bc Greece
fcf482ee-85e7-4bce-9ea1-433eb4a60616 Netherlands
8f9ad557-8bf9-4a4e-bc2d-14f715e59998 Belgium
af53691b-5358-45af-944a-8a35038c7b6f Hungary
8b42f684-c4f1-4b3e-895f-557ee94ea3bf Sweden
312181f5-8c00-4a1e-b034-21e6bb3276f3 Estonia
29d1106e-a88b-4a95-ad7c-d8f9ebc4bd6f Poland
63a0ebd8-774d-43cd-8218-f3a3b1815bbf Croatia
33c66136-2501-43e3-b08b-881aaa3885f1 Norway
a98d77fe-fb79-4e3c-bacc-fc3695b6c1aa Sweden
73026d12-0a4e-44d8-99a9-38dc86184479 Poland
17591b3f-db54-40d3-a2ea-87268e6cd61b Bulgaria
f9d85048-ae86-4ada-aa92-7d4b5192f1c9 Belgium
5a523464-bcc7-4ecf-9740-ff5026268afc Hungary
313f20e6-357d-427d-ae07-38b05b7ec25d Germany
41be6b5b-f9c6-4a2d-a5dd-76c679ba423a Poland
41261ed1-832e-4eae-acb4-aabf716abe2c France
7933d999-2517-4ec7-8f44-d0e8e8fe2cc2 Germany
fb3f596b-c8fe-49cb-9b4f-a30aed5aed28 Germany
f6d20ef4-4758-4a2b-9a84-7716191b9c37 Denmark
e1ef6c99-d62f-43e1-9fc1-83a6eb57b5a4 Czech Republic
692bc6cd-cc1f-40a3-9531-fcfd06075411 Germany
23fdf834-6560-4f22-9e99-6761a9d53fff Finland
123bc802-adcb-4fc9-8bb4-2d7dd8d92aed Italy
9206bd31-7c96-4f2e-a972-ea0bbbad9180 Germany
945a6df2-f86c-4a43-8f63-468ff61ab31f Spain
76aeb018-b24a-43f1-b0c9-4bf7423d9cef Portugal
06dd8d63-c226-4ebe-ac4f-bbcfd9d062bc Greece
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
103 mm
Package Level 1 Gross Weight:
1.29 kg
Package Level 1 EAN:
3471523133235
Package Level 2 Units:
box 8 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.32 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707137
E-Number (Sweden):
3210057
3RT1966-4G Siemens
Siemens 3RT1966-4G Siemens
Sale price 1,455.00 kr
In stock, 12 units
Product
Article Number (Market Facing Number) 3RT19664G | 3RT19664G
Product Description box terminal for 3RT1, 3RB2, 3RW507
Product family Other
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209506107
UPC 754554766782
Commodity Code 85369010
LKZ_FDB/ CatalogID CC-IC10
Product Group 3729
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 1.530 lb
Package size unit of measure in
Packaging Quantity 1
3RT1055-6AF36 Siemens
Siemens 3RT1055-6AF36 Siemens
Sale price 4,949.00 kr
In stock, 19 units
Product
Article Number (Market Facing Number) 3RT10556AF36 | 3RT10556AF36
Product Description power contactor, AC-3e/AC-3 150 A, 75 kW / 400 V AC (50-60 Hz) / DC Uc: 110-127 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: screw terminal
Product family SIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209507319
UPC 754554766324
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3706
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 7.408 lb
Package size unit of measure in
Packaging Quantity 1
LC1D40ABD Schneider Electric
Schneider LC1D40ABD Schneider Electric
Sale price 1,347.00 kr
Only 8 units left

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 24 V DC standard coil

Schneider New Stock Image
Schneider LCIDO9 Schneider
Sale price 928.00 kr
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
LC1D09B7 Schneider Electric
Schneider LC1D09B7 Schneider Electric
Sale price 786.00 kr
In stock, 12 units

TeSys D contactor - 3P(3 NO) - AC-3 - = 440 V 9 A - 24 V AC coil

LC1-D09-BD Schneider
Schneider LC1-D09-BD Schneider
Sale price 1,168.00 kr
Only 8 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 415...440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415...440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phase motors
2 hp at 230/240 V AC 50/60 Hz for 3 phase motors
5 hp at 460/480 V AC 50/60 Hz for 3 phase motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 25 A (at 140 °F (60 °C)) for power circuit
10 A (at 140 °F (60 °C)) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s for power circuit
210 A 104 °F (40 °C) - 1 s for power circuit
30 A 104 °F (40 °C) - 10 min for power circuit
61 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole 1.56 W AC-1
0.2 W AC-3
0.2 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 0.6 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 9 A AC-3 <= 440 V
2 Mcycles 9 A AC-3e <= 440 V
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.25 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.7...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W 5.4 W 68 °F (20 °C))
Hold-in power consumption in W 5.4 W 68 °F (20 °C)
Operating time 63 ±15 % ms closing
20 ±20 % ms opening
Time constant 28 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
1SBL367001R1300 ABB - AF52-30-00-13
ABB 1SBL367001R1300 ABB - AF52-30-00-13
Sale price 1,415.00 kr
Only 6 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.95 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Power AC-3 (Pe):
(400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Operational Power AC-3e (Pe):
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 80 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
0112cbf0-8178-43d5-afe5-258ce47d676c France
Simplified SCIP:
203d519c-f023-42f6-a384-24e520c6d8b3 Germany
f103c547-b240-47ad-bef9-7d2e65ea3e7e Sweden
510faff0-7666-44b3-a702-3590e5746524 Poland
1fe30ce2-7e6a-4ae1-998d-3769559d02ee France
64d6929f-434b-4b58-a91b-637dd7ba6d3a Germany
ca5fbd4b-0e51-4417-9a58-acb0708afe24 Finland
87e53397-35a1-42ad-ba68-befc12cedfda Italy
b9873bdd-a59a-477a-a35d-3d664d0d022c Netherlands
aa64e587-e9f0-4332-b755-e5cf0583458d Greece
c1fac5cf-fc89-4d9a-b38b-55ec371a046e Poland
8ccb50f5-9561-448d-bfb5-ae5746b35c4c Norway
c8130e79-9338-41f4-b1de-4a54f9089e95 Germany
149edc09-3bb3-4a16-9942-bfa6433dcd08 Denmark
808a8d20-e14e-4644-b47e-6b965fc01ad3 Germany
1e6e9d74-c295-4bb9-aec1-88c8d5d2f8b5 Czech Republic
3ff4f900-29bc-4771-ae06-31af5fc42ac6 Poland
8404309e-8ddd-495b-aa8b-4dbc56b5097d Portugal
a375f64e-e126-4d9e-ae9a-56689d4570d6 Hungary
79087227-6a51-4db5-982d-ee84f921f0fc Belgium
28c79fd5-8c97-4f39-b4d3-005d2419cbdb Spain
921f5c0f-583b-49f0-b414-485614d6643b Sweden
79f17cd0-bd46-424d-8f63-37d57e4af7ad Bulgaria
479d4957-05c4-421d-a5bf-045bb0cd69e6 Germany
203d519c-f023-42f6-a384-24e520c6d8b3 Germany
f103c547-b240-47ad-bef9-7d2e65ea3e7e Sweden
510faff0-7666-44b3-a702-3590e5746524 Poland
1fe30ce2-7e6a-4ae1-998d-3769559d02ee France
64d6929f-434b-4b58-a91b-637dd7ba6d3a Germany
ca5fbd4b-0e51-4417-9a58-acb0708afe24 Finland
87e53397-35a1-42ad-ba68-befc12cedfda Italy
b9873bdd-a59a-477a-a35d-3d664d0d022c Netherlands
aa64e587-e9f0-4332-b755-e5cf0583458d Greece
c1fac5cf-fc89-4d9a-b38b-55ec371a046e Poland
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.05 kg
Package Level 1 EAN:
3471523132337
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.5 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707016
E-Number (Sweden):
3210039
1SBL397001R1300 ABB - AF80-30-00-13
ABB 1SBL397001R1300 ABB - AF80-30-00-13
Sale price 2,210.00 kr
Only 8 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
116 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.17 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 125 A
(690 V) 60 °C 100 A
(690 V) 70 °C 85 A
(690 V) 40 °C 125 A
(690 V) 60 °C 100 A
(690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(1000 V) 60 °C 25 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(1000 V) 60 °C 25 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Power AC-3 (Pe):
(400 V) 37 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(1000 V) 35 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
(400 V) 37 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(1000 V) 35 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe):
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7.6 W
at Rated Operating Conditions AC-3 per Pole 3 W
at Rated Operating Conditions AC-1 per Pole 7.6 W
at Rated Operating Conditions AC-3 per Pole 3 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 17 mm
Control Circuit 10 mm
Main Circuit 17 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
3
Continuous Current Rating NEMA:
90 A
Horsepower Rating NEMA:
(200 V AC) Three Phase 25 Hp
(230 V AC) Three Phase 30 Hp
(460 V AC) Three Phase 50 Hp
(575 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 25 Hp
(230 V AC) Three Phase 30 Hp
(460 V AC) Three Phase 50 Hp
(575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 105 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
2d5965a6-5b05-4e83-9459-9b5d78318aa2 France
Simplified SCIP:
57ec6da0-6b74-4d41-942c-28c569726642 Poland
5d3a40e2-0dd2-48f8-ae60-df6cfd6688b6 Belgium
84e38467-b47e-41a7-a633-0e291c7314f6 Hungary
dacab1dc-889c-43ea-957a-0278e2eb9308 Bulgaria
9bd00c9e-233b-4130-8db2-5b4e46325892 Hungary
05d34ee2-b106-4e9e-8aaf-bb3c0696dab1 Belgium
b8f41cb2-309c-4bca-b0f8-31c8411b3c2d Italy
73f32aa1-94bb-4e00-9ed0-49dd4c1836be Germany
f43cd794-f0d3-407d-a0c2-2e1624bd39f8 Netherlands
f6d0f85a-81dc-4d65-a3b8-a6c580818d49 Greece
b5f1e100-759a-4cac-9740-c5ad3386a78c Finland
0bc3bb53-fcd8-496e-bf2c-4988d9b5f9e5 Sweden
98c08dc1-2723-4141-a883-43d88a9c1f8e Poland
4186d146-0fba-45da-a4c2-c87d50cbf7f1 Germany
3115cc1f-b1ba-44a5-a504-88ff86c3be36 Spain
cbacee52-8d3e-4f4d-b9c8-53847a4f9923 Sweden
e2e8ca03-6811-4164-a875-294c3d170711 Norway
64bf0ced-9457-40a7-8fb3-ad748bb21388 Croatia
f12fcaa6-7e48-48c3-8dae-bce6dc6370f1 Portugal
ba370118-f149-4c18-a5b4-98ddd3a0e2ee Germany
72f40100-060e-4ff9-b571-06ff58ce4bfe Denmark
32d40bf1-bae3-4434-bfe4-6d33f50f23d0 Germany
4d8bf81b-1918-4230-bc72-81d884b83cc7 Czech Republic
5061ae4c-ad66-4a1a-8bea-d068495ba286 Poland
c60693b3-55d4-45d9-a28b-032cb87a11b0 Estonia
0b815038-d3f8-47af-b03c-1494f6049fce Germany
87ca08be-a7de-4803-890e-63cdc6854bbf France
57ec6da0-6b74-4d41-942c-28c569726642 Poland
5d3a40e2-0dd2-48f8-ae60-df6cfd6688b6 Belgium
84e38467-b47e-41a7-a633-0e291c7314f6 Hungary
dacab1dc-889c-43ea-957a-0278e2eb9308 Bulgaria
9bd00c9e-233b-4130-8db2-5b4e46325892 Hungary
05d34ee2-b106-4e9e-8aaf-bb3c0696dab1 Belgium
b8f41cb2-309c-4bca-b0f8-31c8411b3c2d Italy
73f32aa1-94bb-4e00-9ed0-49dd4c1836be Germany
f43cd794-f0d3-407d-a0c2-2e1624bd39f8 Netherlands
f6d0f85a-81dc-4d65-a3b8-a6c580818d49 Greece
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
103 mm
Package Level 1 Gross Weight:
1.29 kg
Package Level 1 EAN:
3471523132931
Package Level 2 Units:
box 8 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.32 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707122
E-Number (Sweden):
3210053
3RT2027-1BB40 Siemens
Siemens 3RT2027-1BB40 Siemens
Sale price 2,142.00 kr
In stock, 15 units
Product
Article Number (Market Facing Number) 3RT20271BB40 | 3RT20271BB40
Product Description power contactor, AC-3e/AC-3, 32 A, 15 kW / 400 V, 3-pole, 24 V DC, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S0
Product family SIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209790087
UPC 662643915853
Commodity Code 85364190
LKZ_FDB/ CatalogID CC-IC10
Product Group 5336
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 1.411 lb
Package size unit of measure in
Packaging Quantity 1
3RT2916-1DG00 Siemens
Siemens 3RT2916-1DG00 Siemens
Sale price 681.00 kr
Only 6 units left
Product
Article Number (Market Facing Number) 3RT29161DG00 | 3RT29161DG00
Product Description surge suppressor, suppression diode 12-250 V DC, for contactors 3RT2.1 and auxiliary contactors 3RH2
Product family Surge suppressors
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209740242
UPC 662643918472
Commodity Code 85411000
LKZ_FDB/ CatalogID CC-IC10
Product Group 5344
Group Code R711
Country of origin Czech Republic
SCIP number Not available
Delivery information
Net Weight (lb) 0.011 lb
Package size unit of measure in
Packaging Quantity 1
3RT1916-1BB00 Siemens
Siemens 3RT1916-1BB00 Siemens
Sale price 638.00 kr
Only 6 units left
Product
Article Number (Market Facing Number) 3RT19161BB00 | 3RT19161BB00
Product Description varistor 24...48 V AC, 24...70 V DC Surge suppressor For plugging onto contactors Size S00 !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2916-1BB00<<
Product family Not available
Product Lifecycle (PLM) PM500:Discontinued Product or end of PLM & Support
Additional Product Information
EAN 4011209267398
UPC 754554412610
Commodity Code 85363010
LKZ_FDB/ CatalogID CC-IC10
Product Group 3729
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.018 lb
Package size unit of measure Inch
Packaging Quantity 1

Recently viewed