IX-1000 Keyence

Specifications

Model

IX-1000

Main unit / expansion unit

Main unit

Display

Min. display unit

10 µm*1

Display range

±999.99 to ±999 mm (with 4 selectable steps)*1

Tools

Scan mode

Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2

Line mode

Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2

Other functions

Common

ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,
Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,
Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security

Scan mode

Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination,
Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,
Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range

Line mode

Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)

Input

Input

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Number of inputs

8 (IN1 to IN8)

Function

IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)

Output

Output

Open collector output; NPN/PNP switchable, N.O./N.C. switchable
For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less
For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less

Number of inputs

10 (OUT1 to OUT10)

Function

Enable by assigning the optional functions
Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,
Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm

Analog voltage output

±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3

Analog current output

4 to 20 mA, max. load resistance: 350 Ω*3

Number of programs

32

Statistical information

Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4

Detection record

Number of storage

Scan mode

80 images (FTP/SFTP Client function: Enable)
100 images (FTP/SFTP Client function: Disable)
*5

Line mode

400 images (FTP/SFTP Client function: Enable)
500 images (FTP/SFTP Client function: Disable)
*5

Detection history

Save conditions

NG only/All is selectable*5

FTP/SFTP data transfer (FTP/SFTP client function)

Transfer Destination

FTP/SFTP server

Transfer format

bmp/jpeg/txt is selectable

Transfer Condition

4 conditions
All / Total status result (OK/NG) / Result for each tool (OK/(NG and ALM)) is selectable

Ethernet

Standard

100BASE-TX/10BASE-T*6

Connector

RJ45 8-pin connector*6

Interface compatibility

CC-Link / DeviceNet® / EtherNet/IP™ / EtherCAT / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7

Number of connectible units

Main units: 1, Expansion units: 1, Communication units (DL) : 1

Ratings

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/
Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/
Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC

Weight

Approx. 210 g

*1 For displaying on an IX Series control panel or PC software.
*2 Configurable for each program.
*3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
*4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
*5 Saves to the inner memory of sensor amplifier. The detection history saved in the sensor amplifier can be copied to PC as a backup by using the PC software or the USB mounted on the control panel for IX series.
*6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
*7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
*8 Includes a DL Series communication unit.

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€864,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€864,95
€462,95
€408,95
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

IX-1000

Main unit / expansion unit

Main unit

Display

Min. display unit

10 µm*1

Display range

±999.99 to ±999 mm (with 4 selectable steps)*1

Tools

Scan mode

Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2

Line mode

Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2

Other functions

Common

ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,
Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,
Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security

Scan mode

Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination,
Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,
Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range

Line mode

Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)

Input

Input

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Number of inputs

8 (IN1 to IN8)

Function

IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)

Output

Output

Open collector output; NPN/PNP switchable, N.O./N.C. switchable
For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less
For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less

Number of inputs

10 (OUT1 to OUT10)

Function

Enable by assigning the optional functions
Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,
Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm

Analog voltage output

±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3

Analog current output

4 to 20 mA, max. load resistance: 350 Ω*3

Number of programs

32

Statistical information

Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4

Detection record

Number of storage

Scan mode

80 images (FTP/SFTP Client function: Enable)
100 images (FTP/SFTP Client function: Disable)
*5

Line mode

400 images (FTP/SFTP Client function: Enable)
500 images (FTP/SFTP Client function: Disable)
*5

Detection history

Save conditions

NG only/All is selectable*5

FTP/SFTP data transfer (FTP/SFTP client function)

Transfer Destination

FTP/SFTP server

Transfer format

bmp/jpeg/txt is selectable

Transfer Condition

4 conditions
All / Total status result (OK/NG) / Result for each tool (OK/(NG and ALM)) is selectable

Ethernet

Standard

100BASE-TX/10BASE-T*6

Connector

RJ45 8-pin connector*6

Interface compatibility

CC-Link / DeviceNet® / EtherNet/IP™ / EtherCAT / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7

Number of connectible units

Main units: 1, Expansion units: 1, Communication units (DL) : 1

Ratings

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/
Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/
Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC

Weight

Approx. 210 g

*1 For displaying on an IX Series control panel or PC software.
*2 Configurable for each program.
*3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
*4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
*5 Saves to the inner memory of sensor amplifier. The detection history saved in the sensor amplifier can be copied to PC as a backup by using the PC software or the USB mounted on the control panel for IX series.
*6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
*7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
*8 Includes a DL Series communication unit.

Model

IX-1000

Main unit / expansion unit

Main unit

Display

Min. display unit

10 µm*1

Display range

±999.99 to ±999 mm (with 4 selectable steps)*1

Tools

Scan mode

Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2

Line mode

Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2

Other functions

Common

ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,
Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,
Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security

Scan mode

Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination,
Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,
Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range

Line mode

Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)

Input

Input

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Number of inputs

8 (IN1 to IN8)

Function

IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)

Output

Output

Open collector output; NPN/PNP switchable, N.O./N.C. switchable
For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less
For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less

Number of inputs

10 (OUT1 to OUT10)

Function

Enable by assigning the optional functions
Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,
Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm

Analog voltage output

±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3

Analog current output

4 to 20 mA, max. load resistance: 350 Ω*3

Number of programs

32

Statistical information

Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4

Detection record

Number of storage

Scan mode

80 images (FTP/SFTP Client function: Enable)
100 images (FTP/SFTP Client function: Disable)
*5

Line mode

400 images (FTP/SFTP Client function: Enable)
500 images (FTP/SFTP Client function: Disable)
*5

Detection history

Save conditions

NG only/All is selectable*5

FTP/SFTP data transfer (FTP/SFTP client function)

Transfer Destination

FTP/SFTP server

Transfer format

bmp/jpeg/txt is selectable

Transfer Condition

4 conditions
All / Total status result (OK/NG) / Result for each tool (OK/(NG and ALM)) is selectable

Ethernet

Standard

100BASE-TX/10BASE-T*6

Connector

RJ45 8-pin connector*6

Interface compatibility

CC-Link / DeviceNet® / EtherNet/IP™ / EtherCAT / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7

Number of connectible units

Main units: 1, Expansion units: 1, Communication units (DL) : 1

Ratings

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/
Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/
Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC

Weight

Approx. 210 g

*1 For displaying on an IX Series control panel or PC software.
*2 Configurable for each program.
*3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
*4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
*5 Saves to the inner memory of sensor amplifier. The detection history saved in the sensor amplifier can be copied to PC as a backup by using the PC software or the USB mounted on the control panel for IX series.
*6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
*7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
*8 Includes a DL Series communication unit.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator