FI-T15 Keyence

Specifications

Model

FI-T15

Supported pipe diameter

3/8", 1/2"
(10A, 15A)
ø14–22 ø0.55"–0.87"

Supported pipe materials

Metal piping

Supported temperature range

−20 to +180°C –4 to +356°F*1

Display method

Organic EL, status indicator light

Display resolution

0.1°C 32.18°F

Response time

5 s (50% response), 15 s (90% response)*2

Display amplifier averaging time

0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s

Measurement accuracy

±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3
±1.0°C ±1.8°F (pipe temperature 80–180°C 176–356°F) (ambient temperature of 25°C 77°F)*2*3

Hysteresis

Variable

Measurement principle

Pt100 4-wire type

Power I/O connector

M8 4-pin connector

Power supply

Current consumption

20 mA or less (excluding load current)*4

When used standalone

I/O (switchable)

Output (Ch1/Ch2)

Control output: switching NPN/PNP setting
Open collector output: 30 VDC or less, maximum 100 mA/ch or less, residual voltage 2.5 V or less*5

Analog output (Ch2)

4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5

Power voltage

20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges*5

Network compatibility

IO-Link*6*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

–10 to +60°C -14 to +140°F (no freezing)

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Material

Display amplifier

PBT / PAR / POM / SUS303

Sensor head

Head: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin

Display amplifier mounting bracket

SUS304

Weight

Approx. 80 g 2.82 oz

*1 When pipe temperature is 100°C 212°F or more, the display amplifier cannot be mounted on the pipe clamp unit. Install the amplifier so it is insulated from the heat from the pipe.
*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes and fluid, the ambient temperature and other factors.
*3 This is the value for a constant 25°C 77°F environment, taking into account absolute error and repeatability.
*4 During standalone use, 220 mA or less including load.
*5 When connecting to a FD-H Series/FI-1000 model, please follow the specifications of the display unit.
*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com).
IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€380,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€0,00
€380,95
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

FI-T15

Supported pipe diameter

3/8", 1/2"
(10A, 15A)
ø14–22 ø0.55"–0.87"

Supported pipe materials

Metal piping

Supported temperature range

−20 to +180°C –4 to +356°F*1

Display method

Organic EL, status indicator light

Display resolution

0.1°C 32.18°F

Response time

5 s (50% response), 15 s (90% response)*2

Display amplifier averaging time

0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s

Measurement accuracy

±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3
±1.0°C ±1.8°F (pipe temperature 80–180°C 176–356°F) (ambient temperature of 25°C 77°F)*2*3

Hysteresis

Variable

Measurement principle

Pt100 4-wire type

Power I/O connector

M8 4-pin connector

Power supply

Current consumption

20 mA or less (excluding load current)*4

When used standalone

I/O (switchable)

Output (Ch1/Ch2)

Control output: switching NPN/PNP setting
Open collector output: 30 VDC or less, maximum 100 mA/ch or less, residual voltage 2.5 V or less*5

Analog output (Ch2)

4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5

Power voltage

20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges*5

Network compatibility

IO-Link*6*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

–10 to +60°C -14 to +140°F (no freezing)

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Material

Display amplifier

PBT / PAR / POM / SUS303

Sensor head

Head: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin

Display amplifier mounting bracket

SUS304

Weight

Approx. 80 g 2.82 oz

*1 When pipe temperature is 100°C 212°F or more, the display amplifier cannot be mounted on the pipe clamp unit. Install the amplifier so it is insulated from the heat from the pipe.
*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes and fluid, the ambient temperature and other factors.
*3 This is the value for a constant 25°C 77°F environment, taking into account absolute error and repeatability.
*4 During standalone use, 220 mA or less including load.
*5 When connecting to a FD-H Series/FI-1000 model, please follow the specifications of the display unit.
*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com).
IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).

Model

FI-T15

Supported pipe diameter

3/8", 1/2"
(10A, 15A)
ø14–22 ø0.55"–0.87"

Supported pipe materials

Metal piping

Supported temperature range

−20 to +180°C –4 to +356°F*1

Display method

Organic EL, status indicator light

Display resolution

0.1°C 32.18°F

Response time

5 s (50% response), 15 s (90% response)*2

Display amplifier averaging time

0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s

Measurement accuracy

±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3
±1.0°C ±1.8°F (pipe temperature 80–180°C 176–356°F) (ambient temperature of 25°C 77°F)*2*3

Hysteresis

Variable

Measurement principle

Pt100 4-wire type

Power I/O connector

M8 4-pin connector

Power supply

Current consumption

20 mA or less (excluding load current)*4

When used standalone

I/O (switchable)

Output (Ch1/Ch2)

Control output: switching NPN/PNP setting
Open collector output: 30 VDC or less, maximum 100 mA/ch or less, residual voltage 2.5 V or less*5

Analog output (Ch2)

4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5

Power voltage

20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges*5

Network compatibility

IO-Link*6*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

–10 to +60°C -14 to +140°F (no freezing)

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Material

Display amplifier

PBT / PAR / POM / SUS303

Sensor head

Head: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin

Display amplifier mounting bracket

SUS304

Weight

Approx. 80 g 2.82 oz

*1 When pipe temperature is 100°C 212°F or more, the display amplifier cannot be mounted on the pipe clamp unit. Install the amplifier so it is insulated from the heat from the pipe.
*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes and fluid, the ambient temperature and other factors.
*3 This is the value for a constant 25°C 77°F environment, taking into account absolute error and repeatability.
*4 During standalone use, 220 mA or less including load.
*5 When connecting to a FD-H Series/FI-1000 model, please follow the specifications of the display unit.
*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com).
IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator