FD-MZ50AYK Keyence

Specifications

Model

FD-MZ50AYK*1

Type

Horizontal

Shape

Built-in amplifier

Rated flow range

0.7 - 13.0 G/min (2.5 - 50 L/min)*1

Possible display range

0.7 - 26.4 G/min (2.5 - 100 L/min)*2

Possible ranges to set

0 - 26.4 G/min (0 - 100 L/min)

Connection port

NPT3/4 (20 A)

Detectable fluids

Water or non-corrosive liquid

Conductivity of detection fluids

5 µS/cm or higher

Detection fluid temperature

0 to +85°C 32 to 185 °F (No freezing)

Pressure loss

Max. 1.45 PSI (0.01 MPa)

Display method

Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator

Display resolution

0.1/1 (G/min, L/min) selectable

Repeatability

0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3

Hysteresis

Variable

Response time (chatter prevention feature)

0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable

Accumulated flow unit

0.1/1/10/100/1000 (G, L) selectable

Integration data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)

Analog output

4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value

Integration reset/bank switch input/flow zero function input

Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode

Power consumption (Current consumption)

Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less, Class 2

Environmental resistance

Enclosure rating

IP65

Pressure resistance

290 PSI (2.0 MPa)

Applied pressure range

Max. 145 PSI (1.0 MPa)

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Liquid end materials

Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)

Other materials

Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC

Accessory

Instruction Manual, Connector cable (2.7 m 106.3")

Weight

Approx. 1,130 g

*1 The rated flow range indicates recommended operating range.
*2 Can be used within the display range as well as within the rated flow range.
*3 The repeatability is effective within the display range. Convert the F.S. (full scale) listed in the table according to the rated flow range.

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€1.648,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€0,00
€1.648,95
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

FD-MZ50AYK*1

Type

Horizontal

Shape

Built-in amplifier

Rated flow range

0.7 - 13.0 G/min (2.5 - 50 L/min)*1

Possible display range

0.7 - 26.4 G/min (2.5 - 100 L/min)*2

Possible ranges to set

0 - 26.4 G/min (0 - 100 L/min)

Connection port

NPT3/4 (20 A)

Detectable fluids

Water or non-corrosive liquid

Conductivity of detection fluids

5 µS/cm or higher

Detection fluid temperature

0 to +85°C 32 to 185 °F (No freezing)

Pressure loss

Max. 1.45 PSI (0.01 MPa)

Display method

Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator

Display resolution

0.1/1 (G/min, L/min) selectable

Repeatability

0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3

Hysteresis

Variable

Response time (chatter prevention feature)

0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable

Accumulated flow unit

0.1/1/10/100/1000 (G, L) selectable

Integration data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)

Analog output

4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value

Integration reset/bank switch input/flow zero function input

Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode

Power consumption (Current consumption)

Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less, Class 2

Environmental resistance

Enclosure rating

IP65

Pressure resistance

290 PSI (2.0 MPa)

Applied pressure range

Max. 145 PSI (1.0 MPa)

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Liquid end materials

Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)

Other materials

Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC

Accessory

Instruction Manual, Connector cable (2.7 m 106.3")

Weight

Approx. 1,130 g

*1 The rated flow range indicates recommended operating range.
*2 Can be used within the display range as well as within the rated flow range.
*3 The repeatability is effective within the display range. Convert the F.S. (full scale) listed in the table according to the rated flow range.

Model

FD-MZ50AYK*1

Type

Horizontal

Shape

Built-in amplifier

Rated flow range

0.7 - 13.0 G/min (2.5 - 50 L/min)*1

Possible display range

0.7 - 26.4 G/min (2.5 - 100 L/min)*2

Possible ranges to set

0 - 26.4 G/min (0 - 100 L/min)

Connection port

NPT3/4 (20 A)

Detectable fluids

Water or non-corrosive liquid

Conductivity of detection fluids

5 µS/cm or higher

Detection fluid temperature

0 to +85°C 32 to 185 °F (No freezing)

Pressure loss

Max. 1.45 PSI (0.01 MPa)

Display method

Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator

Display resolution

0.1/1 (G/min, L/min) selectable

Repeatability

0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3

Hysteresis

Variable

Response time (chatter prevention feature)

0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable

Accumulated flow unit

0.1/1/10/100/1000 (G, L) selectable

Integration data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)

Analog output

4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value

Integration reset/bank switch input/flow zero function input

Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode

Power consumption (Current consumption)

Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less, Class 2

Environmental resistance

Enclosure rating

IP65

Pressure resistance

290 PSI (2.0 MPa)

Applied pressure range

Max. 145 PSI (1.0 MPa)

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Liquid end materials

Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)

Other materials

Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC

Accessory

Instruction Manual, Connector cable (2.7 m 106.3")

Weight

Approx. 1,130 g

*1 The rated flow range indicates recommended operating range.
*2 Can be used within the display range as well as within the rated flow range.
*3 The repeatability is effective within the display range. Convert the F.S. (full scale) listed in the table according to the rated flow range.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator