A9XMC1D3 Schneider Electric

This PowerTag Control IO 230V is a wireless-communication input and output module. It is designed specifically for Control and monitoring applications. It is designed to monitor a circuit, notifying wireless to the concentrator the information status of a contract It has to be associated with a concentrator PowerTag Link or a Wiser IP module. This product can be installed in new or existing panels with simple commissioning operation. It has a status LED who provides information about PowerTag Control status. It is mounted on DIN rail and is compatible with horizontal comb busbars 9 mm modules. The Un Rated voltage is Phase-to-neutral 230VAC +/- 20%. The maximum consumption is below or equal to 2VA. The degree of protection is IP20 for casing and IP40 for front face. The operating temperature is between -25°C to +60°C. The storage temperature is between 40°C to +85°C. The dimensions are (W) 18mm x (H) 85mm x (D) 62mm. This product complies with IEC 60529 standard

Main

Characteristic Value(s)
Range PowerTag
Product or component type Input and ouput module
Device short name PowerTag C IO 230V
product name PowerTag Control
Concentrator compatibility Acti9 PowerTag Link C
Wiser IP module
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Range compatibility Acti9 impulse relay
Acti9 contactor
Acti9 iACTs remote indication auxiliary
Acti9 iATLs remote indication auxiliary

Complementary

Characteristic Value(s)
[Us] rated supply voltage 230 V AC (+/- 20 %)
Network frequency 50/60 Hz
Power consumption in VA 2 VA
digital input number 1
Input type Dry contact 230 V AC 2 mA
Voltage state 1 guaranteed >= 164 V for digital input
Voltage state 0 guaranteed <= 40 V for digital input
Current state 1 guaranteed >= 2 mA (digital input)
Current state 0 guaranteed <= 0.5 mA (digital input)
Digital output number 1
Output type Dry contact 230 V 0.01...2 A AC
Discrete output type Configurable relay logic
Output function NO/NC programmable
Mechanical durability 100000 cycles for output
Mounting mode Clip-on
Mounting support DIN rail
Local signalling Green, orange and red LED for product status
Impulse duration 300 ms by default - 0 ms, + 300 ms
Time between 2 impulse 100 ms minimum - tolerance: - 0 ms, + 300 ms
Colour White (RAL 9003)
9 mm pitches 2
Height 85 mm
Material PA6 GF30
Width 18 mm
Depth 62 mm
Product weight 80 g
Connections - terminals Tunnel type terminals (top) - 1 cable(s) 1…16 mm² (AWG 18...AWG 16) - rigid
Tunnel type terminals (top) - 1 cable(s) 0.5…10 mm² (AWG 21...AWG 8) - flexible
Tunnel type terminals (bottom) - 1 cable(s) 1…6 mm² (AWG 18...AWG 10) - rigid
Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (AWG 21...AWG 12) - flexible
Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (AWG 21...AWG 12) - flexible with ferrule
Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (AWG 16...AWG 14) - rigid
Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (AWG 16...AWG 14) - flexible
Wire stripping length 14 mm for top connection
9 mm for bottom connection
Tightening torque Power supply: 2 N.m top
Digital input/output: 1 N.m bottom
Standards EN/IEC 61010-1
ETSI EN 300 328
EN/IEC 62479
ETSI EN 301 489-17
ETSI EN 301 489-1
EN/IEC 61010-2-201
EN/IEC 61326-1
Price on request
Ask for quote
   

Notify Me When Available

This PowerTag Control IO 230V is a wireless-communication input and output module. It is designed specifically for Control and monitoring applications. It is designed to monitor a circuit, notifying wireless to the concentrator the information status of a contract It has to be associated with a concentrator PowerTag Link or a Wiser IP module. This product can be installed in new or existing panels with simple commissioning operation. It has a status LED who provides information about PowerTag Control status. It is mounted on DIN rail and is compatible with horizontal comb busbars 9 mm modules. The Un Rated voltage is Phase-to-neutral 230VAC +/- 20%. The maximum consumption is below or equal to 2VA. The degree of protection is IP20 for casing and IP40 for front face. The operating temperature is between -25°C to +60°C. The storage temperature is between 40°C to +85°C. The dimensions are (W) 18mm x (H) 85mm x (D) 62mm. This product complies with IEC 60529 standard

Main

Characteristic Value(s)
Range PowerTag
Product or component type Input and ouput module
Device short name PowerTag C IO 230V
product name PowerTag Control
Concentrator compatibility Acti9 PowerTag Link C
Wiser IP module
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Range compatibility Acti9 impulse relay
Acti9 contactor
Acti9 iACTs remote indication auxiliary
Acti9 iATLs remote indication auxiliary

Complementary

Characteristic Value(s)
[Us] rated supply voltage 230 V AC (+/- 20 %)
Network frequency 50/60 Hz
Power consumption in VA 2 VA
digital input number 1
Input type Dry contact 230 V AC 2 mA
Voltage state 1 guaranteed >= 164 V for digital input
Voltage state 0 guaranteed <= 40 V for digital input
Current state 1 guaranteed >= 2 mA (digital input)
Current state 0 guaranteed <= 0.5 mA (digital input)
Digital output number 1
Output type Dry contact 230 V 0.01...2 A AC
Discrete output type Configurable relay logic
Output function NO/NC programmable
Mechanical durability 100000 cycles for output
Mounting mode Clip-on
Mounting support DIN rail
Local signalling Green, orange and red LED for product status
Impulse duration 300 ms by default - 0 ms, + 300 ms
Time between 2 impulse 100 ms minimum - tolerance: - 0 ms, + 300 ms
Colour White (RAL 9003)
9 mm pitches 2
Height 85 mm
Material PA6 GF30
Width 18 mm
Depth 62 mm
Product weight 80 g
Connections - terminals Tunnel type terminals (top) - 1 cable(s) 1…16 mm² (AWG 18...AWG 16) - rigid
Tunnel type terminals (top) - 1 cable(s) 0.5…10 mm² (AWG 21...AWG 8) - flexible
Tunnel type terminals (bottom) - 1 cable(s) 1…6 mm² (AWG 18...AWG 10) - rigid
Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (AWG 21...AWG 12) - flexible
Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (AWG 21...AWG 12) - flexible with ferrule
Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (AWG 16...AWG 14) - rigid
Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (AWG 16...AWG 14) - flexible
Wire stripping length 14 mm for top connection
9 mm for bottom connection
Tightening torque Power supply: 2 N.m top
Digital input/output: 1 N.m bottom
Standards EN/IEC 61010-1
ETSI EN 300 328
EN/IEC 62479
ETSI EN 301 489-17
ETSI EN 301 489-1
EN/IEC 61010-2-201
EN/IEC 61326-1
Characteristic Value(s)
[Us] rated supply voltage 230 V AC (+/- 20 %)
Network frequency 50/60 Hz
Power consumption in VA 2 VA
digital input number 1
Input type Dry contact 230 V AC 2 mA
Voltage state 1 guaranteed >= 164 V for digital input
Voltage state 0 guaranteed <= 40 V for digital input
Current state 1 guaranteed >= 2 mA (digital input)
Current state 0 guaranteed <= 0.5 mA (digital input)
Digital output number 1
Output type Dry contact 230 V 0.01...2 A AC
Discrete output type Configurable relay logic
Output function NO/NC programmable
Mechanical durability 100000 cycles for output
Mounting mode Clip-on
Mounting support DIN rail
Local signalling Green, orange and red LED for product status
Impulse duration 300 ms by default - 0 ms, + 300 ms
Time between 2 impulse 100 ms minimum - tolerance: - 0 ms, + 300 ms
Colour White (RAL 9003)
9 mm pitches 2
Height 85 mm
Material PA6 GF30
Width 18 mm
Depth 62 mm
Product weight 80 g
Connections - terminals Tunnel type terminals (top) - 1 cable(s) 1…16 mm² (AWG 18...AWG 16) - rigid
Tunnel type terminals (top) - 1 cable(s) 0.5…10 mm² (AWG 21...AWG 8) - flexible
Tunnel type terminals (bottom) - 1 cable(s) 1…6 mm² (AWG 18...AWG 10) - rigid
Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (AWG 21...AWG 12) - flexible
Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (AWG 21...AWG 12) - flexible with ferrule
Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (AWG 16...AWG 14) - rigid
Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (AWG 16...AWG 14) - flexible
Wire stripping length 14 mm for top connection
9 mm for bottom connection
Tightening torque Power supply: 2 N.m top
Digital input/output: 1 N.m bottom
Standards EN/IEC 61010-1
ETSI EN 300 328
EN/IEC 62479
ETSI EN 301 489-17
ETSI EN 301 489-1
EN/IEC 61010-2-201
EN/IEC 61326-1

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator