1SVR730850R2200 ABB - CM-ENS.23S

Ordering

EAN:
4013614502897
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
85.6 mm
Product Net Depth / Length:
103.7 mm
Product Net Weight:
0.154 kg

Technical

Function:
Filling or draining monitoring
Number of Electrodes:
3
Measuring Range:
0
1 ... 1000 kΩ
0
1 ... 1000 kΩ
Rated Control Supply Voltage (Us):
110 ... 130 V AC
220 ... 240 V AC
110 ... 130 V AC
220 ... 240 V AC
Rated Frequency (f):
Supply Circuit 50/60 Hz
Output:
1 c/o (SPDT) contact
Terminal Type:
Screw Terminals
Rated Operational Current AC-12 (Ie):
(230 V) 4 A
Rated Operational Current AC-15 (Ie):
(230 V) 3 A
Rated Operational Current DC-12 (Ie):
(24 V) 4 A
Rated Operational Current DC-13 (Ie):
(24 V) 2 A
Minimum Switching Capacity:
12 V
10 mA
12 V
10 mA
Rated Impulse Withstand Voltage (Uimp):
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui):
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of Protection:
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
Overvoltage Category:
III
Pollution Degree:
3
Short-Circuit Protective Devices:
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical Durability:
AC-12 100000 cycle
Mechanical Durability:
Nr. Operations 1000000 cycle
Connecting Capacity:
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque:
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Wire Stripping Length:
8 mm
Main Circuit 10 mm
8 mm
Main Circuit 10 mm
Recommended Screw Driver:
0.8 x 4
4.5
Pozidriv 1
0.8 x 4
4.5
Pozidriv 1
Mounting Position:
1 ... 5
1 ... 6
1 ... 5
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards:
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Output Circuit 300 V AC
Contact Rating UL/CSA:
B300
Connecting Capacity UL/CSA:
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA:
7.08 in·lb
Pilot Duty UL/CSA:
B300

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
SCIP:
a02af647-a634-4433-a0d2-5db5f105a229 Germany
Simplified SCIP:
820f4393-360c-4766-bd04-7d334fa889c7 Estonia
ccf2fd05-9bec-4e30-ab2e-1296dc91fc78 Sweden
f0fea5e9-3030-45c6-aaa8-7a64df1872d8 Poland
41d3ad15-a19b-4d95-8d0a-3a28fa8a51d3 Greece
bd03a70d-0819-43da-a9b5-13dcb1368815 Netherlands
6f2594f8-1a38-4d90-827a-77d4ce2cd586 Sweden
54935558-12fc-4f3e-ad91-10379582d962 France
b31a02bc-264c-4f88-8d9e-57fff6af1269 Norway
f4b3745c-37da-4cd7-981a-906a59083eca Croatia
aa0c0e5a-10e6-46f9-a6e9-8a1d5fd3bb6a Spain
1de84df5-9fc0-4c30-9ccd-711909ae0882 Portugal
c7524b58-dfb0-4c8d-8d94-15ee19e302b3 Hungary
9452fd5f-9ccf-4cd6-a26f-9b0b000d63b8 Belgium
3eaf3016-4393-480e-8a87-6212081070c5 Italy
f85bd40c-c3a2-4045-9747-4aed91621ae5 Germany
dc460f81-5b96-4edb-9763-7e7e4e69361a Germany
83af4f6f-460a-4f8c-9e0c-9bb6a4742e32 Czech Republic
09475ef6-bd8a-438d-99bc-d9d0b9144c01 Poland
1467fc13-7ac0-4702-a861-fee8d37ba02f Denmark
475f6b4e-e0f0-4e58-972e-66240cf72049 Hungary
8aa9a114-3b6d-4e95-8b2a-7d2980ed4e42 Bulgaria
9ebd46d1-7b85-49f2-9066-12160f2fc3d1 France
c21c3cb5-05ef-476d-8348-86fd17f7bb95 Germany
fd0ddc47-2fb5-4ffb-b047-b74ff21f3960 Germany
fe6b355c-27b2-46cf-95b7-6971e37c70cf Poland
d76da423-3288-45b2-b2b0-3f75be118675 Belgium
28b74c3e-eb36-4da3-b498-98d850e88a4c Finland
820f4393-360c-4766-bd04-7d334fa889c7 Estonia
ccf2fd05-9bec-4e30-ab2e-1296dc91fc78 Sweden
f0fea5e9-3030-45c6-aaa8-7a64df1872d8 Poland
41d3ad15-a19b-4d95-8d0a-3a28fa8a51d3 Greece
bd03a70d-0819-43da-a9b5-13dcb1368815 Netherlands
6f2594f8-1a38-4d90-827a-77d4ce2cd586 Sweden
54935558-12fc-4f3e-ad91-10379582d962 France
b31a02bc-264c-4f88-8d9e-57fff6af1269 Norway
f4b3745c-37da-4cd7-981a-906a59083eca Croatia
aa0c0e5a-10e6-46f9-a6e9-8a1d5fd3bb6a Spain

ABB EcoSolutions

ABB EcoSolutions:
Yes

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
97 mm
Package Level 1 Depth / Length:
30 mm
Package Level 1 Height:
109 mm
Package Level 1 Gross Weight:
0.179 kg
Package Level 1 EAN:
4013614502897

External Classifications and Standards

Object Classification Code:
B
ETIM 7:
EC001447 - (Fill) level monitoring relay
ETIM 8:
EC001447 - (Fill) level monitoring relay
ETIM 9:
EC001447 - (Fill) level monitoring relay
eClass:
V11.0 : 27371813
UNSPSC:
39122331
E-Number (Finland):
2712570
E-Number (Norway):
4189437
Price on request
Ask for quote
   

Notify Me When Available

Ordering

EAN:
4013614502897
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
85.6 mm
Product Net Depth / Length:
103.7 mm
Product Net Weight:
0.154 kg

Technical

Function:
Filling or draining monitoring
Number of Electrodes:
3
Measuring Range:
0
1 ... 1000 kΩ
0
1 ... 1000 kΩ
Rated Control Supply Voltage (Us):
110 ... 130 V AC
220 ... 240 V AC
110 ... 130 V AC
220 ... 240 V AC
Rated Frequency (f):
Supply Circuit 50/60 Hz
Output:
1 c/o (SPDT) contact
Terminal Type:
Screw Terminals
Rated Operational Current AC-12 (Ie):
(230 V) 4 A
Rated Operational Current AC-15 (Ie):
(230 V) 3 A
Rated Operational Current DC-12 (Ie):
(24 V) 4 A
Rated Operational Current DC-13 (Ie):
(24 V) 2 A
Minimum Switching Capacity:
12 V
10 mA
12 V
10 mA
Rated Impulse Withstand Voltage (Uimp):
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui):
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of Protection:
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
Overvoltage Category:
III
Pollution Degree:
3
Short-Circuit Protective Devices:
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical Durability:
AC-12 100000 cycle
Mechanical Durability:
Nr. Operations 1000000 cycle
Connecting Capacity:
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque:
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Wire Stripping Length:
8 mm
Main Circuit 10 mm
8 mm
Main Circuit 10 mm
Recommended Screw Driver:
0.8 x 4
4.5
Pozidriv 1
0.8 x 4
4.5
Pozidriv 1
Mounting Position:
1 ... 5
1 ... 6
1 ... 5
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards:
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Output Circuit 300 V AC
Contact Rating UL/CSA:
B300
Connecting Capacity UL/CSA:
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA:
7.08 in·lb
Pilot Duty UL/CSA:
B300

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
SCIP:
a02af647-a634-4433-a0d2-5db5f105a229 Germany
Simplified SCIP:
820f4393-360c-4766-bd04-7d334fa889c7 Estonia
ccf2fd05-9bec-4e30-ab2e-1296dc91fc78 Sweden
f0fea5e9-3030-45c6-aaa8-7a64df1872d8 Poland
41d3ad15-a19b-4d95-8d0a-3a28fa8a51d3 Greece
bd03a70d-0819-43da-a9b5-13dcb1368815 Netherlands
6f2594f8-1a38-4d90-827a-77d4ce2cd586 Sweden
54935558-12fc-4f3e-ad91-10379582d962 France
b31a02bc-264c-4f88-8d9e-57fff6af1269 Norway
f4b3745c-37da-4cd7-981a-906a59083eca Croatia
aa0c0e5a-10e6-46f9-a6e9-8a1d5fd3bb6a Spain
1de84df5-9fc0-4c30-9ccd-711909ae0882 Portugal
c7524b58-dfb0-4c8d-8d94-15ee19e302b3 Hungary
9452fd5f-9ccf-4cd6-a26f-9b0b000d63b8 Belgium
3eaf3016-4393-480e-8a87-6212081070c5 Italy
f85bd40c-c3a2-4045-9747-4aed91621ae5 Germany
dc460f81-5b96-4edb-9763-7e7e4e69361a Germany
83af4f6f-460a-4f8c-9e0c-9bb6a4742e32 Czech Republic
09475ef6-bd8a-438d-99bc-d9d0b9144c01 Poland
1467fc13-7ac0-4702-a861-fee8d37ba02f Denmark
475f6b4e-e0f0-4e58-972e-66240cf72049 Hungary
8aa9a114-3b6d-4e95-8b2a-7d2980ed4e42 Bulgaria
9ebd46d1-7b85-49f2-9066-12160f2fc3d1 France
c21c3cb5-05ef-476d-8348-86fd17f7bb95 Germany
fd0ddc47-2fb5-4ffb-b047-b74ff21f3960 Germany
fe6b355c-27b2-46cf-95b7-6971e37c70cf Poland
d76da423-3288-45b2-b2b0-3f75be118675 Belgium
28b74c3e-eb36-4da3-b498-98d850e88a4c Finland
820f4393-360c-4766-bd04-7d334fa889c7 Estonia
ccf2fd05-9bec-4e30-ab2e-1296dc91fc78 Sweden
f0fea5e9-3030-45c6-aaa8-7a64df1872d8 Poland
41d3ad15-a19b-4d95-8d0a-3a28fa8a51d3 Greece
bd03a70d-0819-43da-a9b5-13dcb1368815 Netherlands
6f2594f8-1a38-4d90-827a-77d4ce2cd586 Sweden
54935558-12fc-4f3e-ad91-10379582d962 France
b31a02bc-264c-4f88-8d9e-57fff6af1269 Norway
f4b3745c-37da-4cd7-981a-906a59083eca Croatia
aa0c0e5a-10e6-46f9-a6e9-8a1d5fd3bb6a Spain

ABB EcoSolutions

ABB EcoSolutions:
Yes

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
97 mm
Package Level 1 Depth / Length:
30 mm
Package Level 1 Height:
109 mm
Package Level 1 Gross Weight:
0.179 kg
Package Level 1 EAN:
4013614502897

External Classifications and Standards

Object Classification Code:
B
ETIM 7:
EC001447 - (Fill) level monitoring relay
ETIM 8:
EC001447 - (Fill) level monitoring relay
ETIM 9:
EC001447 - (Fill) level monitoring relay
eClass:
V11.0 : 27371813
UNSPSC:
39122331
E-Number (Finland):
2712570
E-Number (Norway):
4189437
Object Classification Code:
B
ETIM 7:
EC001447 - (Fill) level monitoring relay
ETIM 8:
EC001447 - (Fill) level monitoring relay
ETIM 9:
EC001447 - (Fill) level monitoring relay
eClass:
V11.0 : 27371813
UNSPSC:
39122331
E-Number (Finland):
2712570
E-Number (Norway):
4189437

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator