1SVR730850R0200 ABB - CM-ENS.21S

Ordering

EAN:
4013614502927
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
85.6 mm
Product Net Depth / Length:
103.7 mm
Product Net Weight:
0.125 kg

Technical

Function:
Filling or draining monitoring
Number of Electrodes:
3
Measuring Range:
0
1 ... 1000 kΩ
0
1 ... 1000 kΩ
Rated Control Supply Voltage (Us):
24 ... 240 V AC/DC
Rated Frequency (f):
Supply Circuit 50/60 Hz
Output:
1 c/o (SPDT) contact
Terminal Type:
Screw Terminals
Rated Operational Current AC-12 (Ie):
(230 V) 4 A
Rated Operational Current AC-15 (Ie):
(230 V) 3 A
Rated Operational Current DC-12 (Ie):
(24 V) 4 A
Rated Operational Current DC-13 (Ie):
(24 V) 2 A
Minimum Switching Capacity:
12 V
10 mA
12 V
10 mA
Rated Impulse Withstand Voltage (Uimp):
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui):
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of Protection:
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
Overvoltage Category:
III
Pollution Degree:
3
Short-Circuit Protective Devices:
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical Durability:
AC-12 100000 cycle
Mechanical Durability:
Nr. Operations 1000000 cycle
Connecting Capacity:
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque:
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Wire Stripping Length:
8 mm
Main Circuit 10 mm
8 mm
Main Circuit 10 mm
Recommended Screw Driver:
0.8 x 4
4.5
Pozidriv 1
0.8 x 4
4.5
Pozidriv 1
Mounting Position:
1 ... 5
1 ... 6
1 ... 5
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards:
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Output Circuit 300 V AC
Contact Rating UL/CSA:
B300
Connecting Capacity UL/CSA:
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA:
7.08 in·lb
Pilot Duty UL/CSA:
B300

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
SCIP:
8eb6fdcd-73c5-4ba0-b3a1-9e5817ec884e Germany
Simplified SCIP:
76258664-4ddd-4466-b2c5-48f1c81ca946 Netherlands
26ab315d-e5da-4ab6-8c33-ab7f38c90975 Hungary
fe68a77a-8670-4b59-8555-b95bd9824d7a Greece
e8f2294c-dbbc-4561-9c78-4314def99756 Portugal
cbdbf5ed-7133-47ec-8651-a9f37a9066f9 Bulgaria
eb40b6c8-0a1c-46a2-91bb-496e70639147 Poland
c2f2bb05-9e30-4336-aa89-f69f95fa56cd Poland
49d8b886-023e-4bc2-a01d-558931ab2346 Denmark
b9de77df-1f6c-4e41-b708-281b213082d9 Germany
4976fb04-fd79-4e27-8b32-21e435792153 Czech Republic
0518aaac-b252-43b3-aef0-d1e99ab14fc9 Belgium
bee4938e-7679-4452-bf30-5f5a2792318e Germany
40185897-a424-4a5e-ba3d-0bf682672898 Italy
061ab983-5115-446e-9255-170942d4fa96 Finland
2a626756-2bd1-4ec4-b6b3-bfc9c5bc5efb Germany
89a45059-804a-4ced-a2da-ceb086ce357d Poland
752e6fb7-11bc-4ae9-90ab-f7d8a804b173 Norway
8b4adfc1-4dda-4d0e-b0a9-b43ceb4dafc9 Spain
17538767-09fa-4021-9a76-16288c957ce6 Belgium
ef12d084-5e34-46b2-bb21-25d06d85bd82 Hungary
8cc851ab-76f8-4af2-9885-89f38ddef669 Sweden
10874a15-4eaf-4eee-a33d-285d212712ae Sweden
8569279f-c350-4786-8f4f-be4bf9579b5a Germany
3ef8264d-6856-4261-8eb5-dc14f460f435 France
e8bcdcc0-7cf8-45ba-bcd6-5b25da0b21f4 France
6898e71a-1007-4d40-a606-fdfc6a7e922c Estonia
baddfe5a-b431-4ec2-bb27-0906c4b8c466 Croatia
76258664-4ddd-4466-b2c5-48f1c81ca946 Netherlands
26ab315d-e5da-4ab6-8c33-ab7f38c90975 Hungary
fe68a77a-8670-4b59-8555-b95bd9824d7a Greece
e8f2294c-dbbc-4561-9c78-4314def99756 Portugal
cbdbf5ed-7133-47ec-8651-a9f37a9066f9 Bulgaria
eb40b6c8-0a1c-46a2-91bb-496e70639147 Poland
c2f2bb05-9e30-4336-aa89-f69f95fa56cd Poland
49d8b886-023e-4bc2-a01d-558931ab2346 Denmark
b9de77df-1f6c-4e41-b708-281b213082d9 Germany
4976fb04-fd79-4e27-8b32-21e435792153 Czech Republic

ABB EcoSolutions

ABB EcoSolutions:
Yes

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
97 mm
Package Level 1 Depth / Length:
30 mm
Package Level 1 Height:
109 mm
Package Level 1 Gross Weight:
0.15 kg
Package Level 1 EAN:
4013614502927

External Classifications and Standards

Object Classification Code:
B
ETIM 7:
EC001447 - (Fill) level monitoring relay
ETIM 8:
EC001447 - (Fill) level monitoring relay
ETIM 9:
EC001447 - (Fill) level monitoring relay
eClass:
V11.0 : 27371813
UNSPSC:
39122331
E-Number (Finland):
2712567
E-Number (Norway):
4189434
Price on request
Ask for quote
   

Notify Me When Available

Ordering

EAN:
4013614502927
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
85.6 mm
Product Net Depth / Length:
103.7 mm
Product Net Weight:
0.125 kg

Technical

Function:
Filling or draining monitoring
Number of Electrodes:
3
Measuring Range:
0
1 ... 1000 kΩ
0
1 ... 1000 kΩ
Rated Control Supply Voltage (Us):
24 ... 240 V AC/DC
Rated Frequency (f):
Supply Circuit 50/60 Hz
Output:
1 c/o (SPDT) contact
Terminal Type:
Screw Terminals
Rated Operational Current AC-12 (Ie):
(230 V) 4 A
Rated Operational Current AC-15 (Ie):
(230 V) 3 A
Rated Operational Current DC-12 (Ie):
(24 V) 4 A
Rated Operational Current DC-13 (Ie):
(24 V) 2 A
Minimum Switching Capacity:
12 V
10 mA
12 V
10 mA
Rated Impulse Withstand Voltage (Uimp):
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui):
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of Protection:
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
Overvoltage Category:
III
Pollution Degree:
3
Short-Circuit Protective Devices:
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical Durability:
AC-12 100000 cycle
Mechanical Durability:
Nr. Operations 1000000 cycle
Connecting Capacity:
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque:
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
0.6 ... 0.8 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Wire Stripping Length:
8 mm
Main Circuit 10 mm
8 mm
Main Circuit 10 mm
Recommended Screw Driver:
0.8 x 4
4.5
Pozidriv 1
0.8 x 4
4.5
Pozidriv 1
Mounting Position:
1 ... 5
1 ... 6
1 ... 5
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards:
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Output Circuit 300 V AC
Contact Rating UL/CSA:
B300
Connecting Capacity UL/CSA:
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA:
7.08 in·lb
Pilot Duty UL/CSA:
B300

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
SCIP:
8eb6fdcd-73c5-4ba0-b3a1-9e5817ec884e Germany
Simplified SCIP:
76258664-4ddd-4466-b2c5-48f1c81ca946 Netherlands
26ab315d-e5da-4ab6-8c33-ab7f38c90975 Hungary
fe68a77a-8670-4b59-8555-b95bd9824d7a Greece
e8f2294c-dbbc-4561-9c78-4314def99756 Portugal
cbdbf5ed-7133-47ec-8651-a9f37a9066f9 Bulgaria
eb40b6c8-0a1c-46a2-91bb-496e70639147 Poland
c2f2bb05-9e30-4336-aa89-f69f95fa56cd Poland
49d8b886-023e-4bc2-a01d-558931ab2346 Denmark
b9de77df-1f6c-4e41-b708-281b213082d9 Germany
4976fb04-fd79-4e27-8b32-21e435792153 Czech Republic
0518aaac-b252-43b3-aef0-d1e99ab14fc9 Belgium
bee4938e-7679-4452-bf30-5f5a2792318e Germany
40185897-a424-4a5e-ba3d-0bf682672898 Italy
061ab983-5115-446e-9255-170942d4fa96 Finland
2a626756-2bd1-4ec4-b6b3-bfc9c5bc5efb Germany
89a45059-804a-4ced-a2da-ceb086ce357d Poland
752e6fb7-11bc-4ae9-90ab-f7d8a804b173 Norway
8b4adfc1-4dda-4d0e-b0a9-b43ceb4dafc9 Spain
17538767-09fa-4021-9a76-16288c957ce6 Belgium
ef12d084-5e34-46b2-bb21-25d06d85bd82 Hungary
8cc851ab-76f8-4af2-9885-89f38ddef669 Sweden
10874a15-4eaf-4eee-a33d-285d212712ae Sweden
8569279f-c350-4786-8f4f-be4bf9579b5a Germany
3ef8264d-6856-4261-8eb5-dc14f460f435 France
e8bcdcc0-7cf8-45ba-bcd6-5b25da0b21f4 France
6898e71a-1007-4d40-a606-fdfc6a7e922c Estonia
baddfe5a-b431-4ec2-bb27-0906c4b8c466 Croatia
76258664-4ddd-4466-b2c5-48f1c81ca946 Netherlands
26ab315d-e5da-4ab6-8c33-ab7f38c90975 Hungary
fe68a77a-8670-4b59-8555-b95bd9824d7a Greece
e8f2294c-dbbc-4561-9c78-4314def99756 Portugal
cbdbf5ed-7133-47ec-8651-a9f37a9066f9 Bulgaria
eb40b6c8-0a1c-46a2-91bb-496e70639147 Poland
c2f2bb05-9e30-4336-aa89-f69f95fa56cd Poland
49d8b886-023e-4bc2-a01d-558931ab2346 Denmark
b9de77df-1f6c-4e41-b708-281b213082d9 Germany
4976fb04-fd79-4e27-8b32-21e435792153 Czech Republic

ABB EcoSolutions

ABB EcoSolutions:
Yes

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
97 mm
Package Level 1 Depth / Length:
30 mm
Package Level 1 Height:
109 mm
Package Level 1 Gross Weight:
0.15 kg
Package Level 1 EAN:
4013614502927

External Classifications and Standards

Object Classification Code:
B
ETIM 7:
EC001447 - (Fill) level monitoring relay
ETIM 8:
EC001447 - (Fill) level monitoring relay
ETIM 9:
EC001447 - (Fill) level monitoring relay
eClass:
V11.0 : 27371813
UNSPSC:
39122331
E-Number (Finland):
2712567
E-Number (Norway):
4189434
Object Classification Code:
B
ETIM 7:
EC001447 - (Fill) level monitoring relay
ETIM 8:
EC001447 - (Fill) level monitoring relay
ETIM 9:
EC001447 - (Fill) level monitoring relay
eClass:
V11.0 : 27371813
UNSPSC:
39122331
E-Number (Finland):
2712567
E-Number (Norway):
4189434

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator