1SDA072968R1 ABB - E2.2B 1600 Ekip Hi-Touch LSI 4p WMP

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
befb09f2-d8ad-4794-b22b-1cc37cf0e966 Italy
Simplified SCIP:
e8e563a1-6f91-4e04-8f5f-e7f02988622b Germany
1894c8c9-4905-44d3-b568-3eb374a6329d Spain
e2dcff75-47c3-49e3-9a09-a399df1daa52 Sweden
dd1cedee-4086-4afa-9dbb-1e131cbb13b4 Bulgaria
7d805b90-36f2-46b7-9290-7aac49e48312 Portugal
76b01b51-a7fd-4fbb-a0f1-8124db947201 Czech Republic
863c8c15-798f-4d80-81fb-96b64b88cbf2 Poland
80a697b3-5078-4b8f-a73e-ca2564ffd23c Poland
7d3c81eb-1422-4f75-8538-c9d0d34ad5ba Belgium
62d771aa-b80e-4319-be9d-a44d9d99092d Germany
91f810a0-79af-456e-a7df-12b49d304d92 Germany
77c385ef-965f-4a27-b12c-e816caf9f1a4 Croatia
22063ddf-6553-4dbf-95ec-25a1a42b1ac2 Germany
87046ffb-ac25-4edf-a0a9-a0cb7f9c22f0 Denmark
180752df-115b-439a-a8a1-0ca7f12b93b4 France
8506880c-53df-4f3f-b6b3-b1a20f5bb006 Belgium
55c166af-147d-45f8-a4fc-815a9a823db0 Hungary
cfe5a3c5-fbf5-4e96-814a-66e80548eac6 France
9fecc417-c07c-4475-914f-d0c64e6745a7 Hungary
c2844164-7eed-4545-9d7d-451bd1ce37b1 Norway
6b9371d3-afad-488d-b838-a3905f875e2e Sweden
2737fc79-6a9d-463b-a454-05d254bb1bd4 Estonia
dee4605a-e7bd-438e-8277-719914d1fd5e Netherlands
e19f73ca-debe-498a-97be-985418766a3f Greece
0bde06b5-3b85-4990-85c8-5e7db21f9e66 Finland
68fa0845-743c-45d8-8197-5dbc75912828 Poland
22db41c9-478d-4ff7-a211-106938377f82 Germany
e8e563a1-6f91-4e04-8f5f-e7f02988622b Germany
1894c8c9-4905-44d3-b568-3eb374a6329d Spain
e2dcff75-47c3-49e3-9a09-a399df1daa52 Sweden
dd1cedee-4086-4afa-9dbb-1e131cbb13b4 Bulgaria
7d805b90-36f2-46b7-9290-7aac49e48312 Portugal
76b01b51-a7fd-4fbb-a0f1-8124db947201 Czech Republic
863c8c15-798f-4d80-81fb-96b64b88cbf2 Poland
80a697b3-5078-4b8f-a73e-ca2564ffd23c Poland
7d3c81eb-1422-4f75-8538-c9d0d34ad5ba Belgium
62d771aa-b80e-4319-be9d-a44d9d99092d Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
ZBBSEJAJ200A000000XX
EAN:
8015644768188
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
407 mm
Product Net Height:
425 mm
Product Net Depth / Length:
383 mm
Product Net Weight:
55 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
60 kg
Package Level 1 EAN:
8015644768188

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu]):
100 %
Number of Poles:
4P
Power Loss:
288 W
Rated Current (In):
1600 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
1600 A
Rated Voltage (Ur):
690 V
Release:
Ekip Hi-Touch LSI
Release Type:
EL
Short-Circuit Performance Level:
B
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
befb09f2-d8ad-4794-b22b-1cc37cf0e966 Italy
Simplified SCIP:
e8e563a1-6f91-4e04-8f5f-e7f02988622b Germany
1894c8c9-4905-44d3-b568-3eb374a6329d Spain
e2dcff75-47c3-49e3-9a09-a399df1daa52 Sweden
dd1cedee-4086-4afa-9dbb-1e131cbb13b4 Bulgaria
7d805b90-36f2-46b7-9290-7aac49e48312 Portugal
76b01b51-a7fd-4fbb-a0f1-8124db947201 Czech Republic
863c8c15-798f-4d80-81fb-96b64b88cbf2 Poland
80a697b3-5078-4b8f-a73e-ca2564ffd23c Poland
7d3c81eb-1422-4f75-8538-c9d0d34ad5ba Belgium
62d771aa-b80e-4319-be9d-a44d9d99092d Germany
91f810a0-79af-456e-a7df-12b49d304d92 Germany
77c385ef-965f-4a27-b12c-e816caf9f1a4 Croatia
22063ddf-6553-4dbf-95ec-25a1a42b1ac2 Germany
87046ffb-ac25-4edf-a0a9-a0cb7f9c22f0 Denmark
180752df-115b-439a-a8a1-0ca7f12b93b4 France
8506880c-53df-4f3f-b6b3-b1a20f5bb006 Belgium
55c166af-147d-45f8-a4fc-815a9a823db0 Hungary
cfe5a3c5-fbf5-4e96-814a-66e80548eac6 France
9fecc417-c07c-4475-914f-d0c64e6745a7 Hungary
c2844164-7eed-4545-9d7d-451bd1ce37b1 Norway
6b9371d3-afad-488d-b838-a3905f875e2e Sweden
2737fc79-6a9d-463b-a454-05d254bb1bd4 Estonia
dee4605a-e7bd-438e-8277-719914d1fd5e Netherlands
e19f73ca-debe-498a-97be-985418766a3f Greece
0bde06b5-3b85-4990-85c8-5e7db21f9e66 Finland
68fa0845-743c-45d8-8197-5dbc75912828 Poland
22db41c9-478d-4ff7-a211-106938377f82 Germany
e8e563a1-6f91-4e04-8f5f-e7f02988622b Germany
1894c8c9-4905-44d3-b568-3eb374a6329d Spain
e2dcff75-47c3-49e3-9a09-a399df1daa52 Sweden
dd1cedee-4086-4afa-9dbb-1e131cbb13b4 Bulgaria
7d805b90-36f2-46b7-9290-7aac49e48312 Portugal
76b01b51-a7fd-4fbb-a0f1-8124db947201 Czech Republic
863c8c15-798f-4d80-81fb-96b64b88cbf2 Poland
80a697b3-5078-4b8f-a73e-ca2564ffd23c Poland
7d3c81eb-1422-4f75-8538-c9d0d34ad5ba Belgium
62d771aa-b80e-4319-be9d-a44d9d99092d Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
ZBBSEJAJ200A000000XX
EAN:
8015644768188
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
407 mm
Product Net Height:
425 mm
Product Net Depth / Length:
383 mm
Product Net Weight:
55 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
60 kg
Package Level 1 EAN:
8015644768188

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu]):
100 %
Number of Poles:
4P
Power Loss:
288 W
Rated Current (In):
1600 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
1600 A
Rated Voltage (Ur):
690 V
Release:
Ekip Hi-Touch LSI
Release Type:
EL
Short-Circuit Performance Level:
B
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator