1SDA070755R1 ABB

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 76.4 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
6daf2ec2-e6a0-4404-a771-e25bb3a6f144 Italy
Simplified SCIP:
4acc1e47-f7d8-4d18-a7c4-99d080a40b98 Bulgaria
bd6aeab8-9e4e-4b19-bd5d-63a096a6d175 Denmark
b9888195-0288-42f5-92a7-d5e12c5c0689 Germany
16a85f33-7722-4ca3-8296-cc47eaf07f75 France
1369a33f-1963-4b57-8474-e6ec24e201fe Norway
ce4df47c-a97f-4c4c-b908-f378a67b7d4e Greece
d5dd11f2-a729-41ca-968f-c7e09bfa3477 Germany
af2734fe-f905-4d39-b288-ddab5ccbe3f4 Finland
ee3d9338-4ee7-49ad-bd85-3f20ab083045 Czech Republic
86403ff0-e86d-4e12-b6fa-25a8649e6fa4 Portugal
d4b50139-ff9e-4439-b262-4e58f6a34500 Croatia
13caf053-52ff-42c3-943e-7ddff319b969 Sweden
052c01a2-af17-459e-af49-ab774eed6a4b Germany
a37dfced-eb85-42d0-8c96-0ef639815280 Hungary
dc715bb2-b6af-45c8-994f-152f2662535b Germany
8597164c-a4b9-41ea-90b6-83ae8d0e7e49 Poland
9f7a352f-909b-4673-9e5d-4aff94362d76 Netherlands
af0dc8df-fccc-4eda-9534-0d93938dfbc0 Poland
d1f788e2-9530-495c-8a9e-30d03f1137ba France
00a7d92c-26a9-4c2d-8a07-964c1272c89f Hungary
346e2a4e-177f-49e6-9f1c-193a4f5545d4 Spain
2a53a7c3-8b57-48df-bb06-d12f7adc99c0 Belgium
b5323cc4-98c8-48d9-9cd2-fcc0ede1a6cd Estonia
0eff54b9-e5f9-4600-a950-025b21a388ee Poland
84abefab-1730-4902-8b42-406f8a4c8c3a Sweden
0ddff0f3-8c5e-4a5d-9922-a7071ff3b21f Belgium
6c2bf012-7666-45fb-b4ce-30f98cda82fc Germany
4acc1e47-f7d8-4d18-a7c4-99d080a40b98 Bulgaria
bd6aeab8-9e4e-4b19-bd5d-63a096a6d175 Denmark
b9888195-0288-42f5-92a7-d5e12c5c0689 Germany
16a85f33-7722-4ca3-8296-cc47eaf07f75 France
1369a33f-1963-4b57-8474-e6ec24e201fe Norway
ce4df47c-a97f-4c4c-b908-f378a67b7d4e Greece
d5dd11f2-a729-41ca-968f-c7e09bfa3477 Germany
af2734fe-f905-4d39-b288-ddab5ccbe3f4 Finland
ee3d9338-4ee7-49ad-bd85-3f20ab083045 Czech Republic
86403ff0-e86d-4e12-b6fa-25a8649e6fa4 Portugal

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z1CPEFBE000A000000XX
EAN:
8015644746056
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
210 mm
Product Net Height:
296 mm
Product Net Depth / Length:
183 mm
Product Net Weight:
14 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
270 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
330 mm
Package Level 1 Gross Weight:
16 kg
Package Level 1 EAN:
8015644746056

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
50 W
Rated Current (In):
800 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA
for 3 s 24 kA
for 1 s 42 kA
for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
800 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M10
Release:
Ekip Touch LSI
Release Type:
EL
Short-Circuit Performance Level:
C
Standards:
IEC
Sub-type:
E1.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
45 N·m

Certificates and Declarations

ATEX Certificate:
CSA Certificate:
CSA Certificate (Intrinsic Safe):
Declaration of Conformity - CE:
UL Certificate:
VDE Certificate:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 76.4 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
6daf2ec2-e6a0-4404-a771-e25bb3a6f144 Italy
Simplified SCIP:
4acc1e47-f7d8-4d18-a7c4-99d080a40b98 Bulgaria
bd6aeab8-9e4e-4b19-bd5d-63a096a6d175 Denmark
b9888195-0288-42f5-92a7-d5e12c5c0689 Germany
16a85f33-7722-4ca3-8296-cc47eaf07f75 France
1369a33f-1963-4b57-8474-e6ec24e201fe Norway
ce4df47c-a97f-4c4c-b908-f378a67b7d4e Greece
d5dd11f2-a729-41ca-968f-c7e09bfa3477 Germany
af2734fe-f905-4d39-b288-ddab5ccbe3f4 Finland
ee3d9338-4ee7-49ad-bd85-3f20ab083045 Czech Republic
86403ff0-e86d-4e12-b6fa-25a8649e6fa4 Portugal
d4b50139-ff9e-4439-b262-4e58f6a34500 Croatia
13caf053-52ff-42c3-943e-7ddff319b969 Sweden
052c01a2-af17-459e-af49-ab774eed6a4b Germany
a37dfced-eb85-42d0-8c96-0ef639815280 Hungary
dc715bb2-b6af-45c8-994f-152f2662535b Germany
8597164c-a4b9-41ea-90b6-83ae8d0e7e49 Poland
9f7a352f-909b-4673-9e5d-4aff94362d76 Netherlands
af0dc8df-fccc-4eda-9534-0d93938dfbc0 Poland
d1f788e2-9530-495c-8a9e-30d03f1137ba France
00a7d92c-26a9-4c2d-8a07-964c1272c89f Hungary
346e2a4e-177f-49e6-9f1c-193a4f5545d4 Spain
2a53a7c3-8b57-48df-bb06-d12f7adc99c0 Belgium
b5323cc4-98c8-48d9-9cd2-fcc0ede1a6cd Estonia
0eff54b9-e5f9-4600-a950-025b21a388ee Poland
84abefab-1730-4902-8b42-406f8a4c8c3a Sweden
0ddff0f3-8c5e-4a5d-9922-a7071ff3b21f Belgium
6c2bf012-7666-45fb-b4ce-30f98cda82fc Germany
4acc1e47-f7d8-4d18-a7c4-99d080a40b98 Bulgaria
bd6aeab8-9e4e-4b19-bd5d-63a096a6d175 Denmark
b9888195-0288-42f5-92a7-d5e12c5c0689 Germany
16a85f33-7722-4ca3-8296-cc47eaf07f75 France
1369a33f-1963-4b57-8474-e6ec24e201fe Norway
ce4df47c-a97f-4c4c-b908-f378a67b7d4e Greece
d5dd11f2-a729-41ca-968f-c7e09bfa3477 Germany
af2734fe-f905-4d39-b288-ddab5ccbe3f4 Finland
ee3d9338-4ee7-49ad-bd85-3f20ab083045 Czech Republic
86403ff0-e86d-4e12-b6fa-25a8649e6fa4 Portugal

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z1CPEFBE000A000000XX
EAN:
8015644746056
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
210 mm
Product Net Height:
296 mm
Product Net Depth / Length:
183 mm
Product Net Weight:
14 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
270 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
330 mm
Package Level 1 Gross Weight:
16 kg
Package Level 1 EAN:
8015644746056

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
50 W
Rated Current (In):
800 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA
for 3 s 24 kA
for 1 s 42 kA
for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
800 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M10
Release:
Ekip Touch LSI
Release Type:
EL
Short-Circuit Performance Level:
C
Standards:
IEC
Sub-type:
E1.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
45 N·m

Certificates and Declarations

ATEX Certificate:
CSA Certificate:
CSA Certificate (Intrinsic Safe):
Declaration of Conformity - CE:
UL Certificate:
VDE Certificate:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator