1SDA068066R1 ABB XT3N 250 TMD 250-2500 4p F F InN50%

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
57eadf4a-5970-4adf-a4da-066359f9153b Italy
Simplified SCIP:
5b32d049-ad48-4123-95f2-48f433ef6c19 Germany
81e60ee8-6c0e-44b2-95d5-91c754b56e0e Poland
24c809ec-b12f-4fb3-9cdf-95b8b1032b35 Netherlands
5963c41a-8c00-4cbf-81d0-28eb6ecbb283 Estonia
3f64f079-43e8-47cd-b114-d10d69ba9d34 Greece
3c8f0030-2e09-48d3-8888-aef966763b63 Portugal
153c2cda-5baf-425b-8b35-67feaf39186c Bulgaria
952ae9e2-bdc7-4763-b509-2ba57c09265d Sweden
004b5065-4539-4704-b3b9-a87ac5e094b4 Germany
ee7c403e-febd-435c-a589-2edcd405aea0 Sweden
565848d3-dafb-4931-958e-167237b6fd20 Denmark
5b915541-3971-4c01-9202-853874e5e858 Germany
2c2ed932-0b95-4560-96dc-098bb3d22421 Poland
dbd2837a-4142-4a2a-a55f-f7084a20ca88 Norway
b9cbdc10-27f8-451b-8430-af420a947ce3 Finland
ef77859c-e0c2-44e4-ae97-1ff5209c271c Netherlands
d434b549-c0e5-4ef2-b0dd-5ef97d321094 Croatia
209b1d3f-2fea-4911-883a-1209260f589a Czech Republic
010584df-cf52-441e-abd4-64b76e41c427 Poland
4fc2b5c4-f16c-479f-b7f9-daa21bda0099 France
5bde1267-5475-4c87-87f2-b7d48c4823b9 Germany
5bee0812-d8e7-4349-92ef-2c2399a7b578 Germany
1883f205-3976-4283-8397-26eb947565b6 France
447066ea-1d76-4cc5-aa4e-770312887d67 Netherlands
674f5277-7576-4fb4-99b8-f82b2696cd4f Spain
093ceba4-3512-4c9c-aea4-637123d56417 Netherlands
ff18c3a7-f475-4ca2-83a3-82dadc281c72 Netherlands
5b32d049-ad48-4123-95f2-48f433ef6c19 Germany
81e60ee8-6c0e-44b2-95d5-91c754b56e0e Poland
24c809ec-b12f-4fb3-9cdf-95b8b1032b35 Netherlands
5963c41a-8c00-4cbf-81d0-28eb6ecbb283 Estonia
3f64f079-43e8-47cd-b114-d10d69ba9d34 Greece
3c8f0030-2e09-48d3-8888-aef966763b63 Portugal
153c2cda-5baf-425b-8b35-67feaf39186c Bulgaria
952ae9e2-bdc7-4763-b509-2ba57c09265d Sweden
004b5065-4539-4704-b3b9-a87ac5e094b4 Germany
ee7c403e-febd-435c-a589-2edcd405aea0 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NEN250AFF000XXX
E-Number (Finland):
3641013
EAN:
8015644019679
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
140 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
2.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
2.214 kg
Package Level 1 EAN:
8015644019679

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 17.8 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
2500 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€783,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€0,00
€783,95
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
57eadf4a-5970-4adf-a4da-066359f9153b Italy
Simplified SCIP:
5b32d049-ad48-4123-95f2-48f433ef6c19 Germany
81e60ee8-6c0e-44b2-95d5-91c754b56e0e Poland
24c809ec-b12f-4fb3-9cdf-95b8b1032b35 Netherlands
5963c41a-8c00-4cbf-81d0-28eb6ecbb283 Estonia
3f64f079-43e8-47cd-b114-d10d69ba9d34 Greece
3c8f0030-2e09-48d3-8888-aef966763b63 Portugal
153c2cda-5baf-425b-8b35-67feaf39186c Bulgaria
952ae9e2-bdc7-4763-b509-2ba57c09265d Sweden
004b5065-4539-4704-b3b9-a87ac5e094b4 Germany
ee7c403e-febd-435c-a589-2edcd405aea0 Sweden
565848d3-dafb-4931-958e-167237b6fd20 Denmark
5b915541-3971-4c01-9202-853874e5e858 Germany
2c2ed932-0b95-4560-96dc-098bb3d22421 Poland
dbd2837a-4142-4a2a-a55f-f7084a20ca88 Norway
b9cbdc10-27f8-451b-8430-af420a947ce3 Finland
ef77859c-e0c2-44e4-ae97-1ff5209c271c Netherlands
d434b549-c0e5-4ef2-b0dd-5ef97d321094 Croatia
209b1d3f-2fea-4911-883a-1209260f589a Czech Republic
010584df-cf52-441e-abd4-64b76e41c427 Poland
4fc2b5c4-f16c-479f-b7f9-daa21bda0099 France
5bde1267-5475-4c87-87f2-b7d48c4823b9 Germany
5bee0812-d8e7-4349-92ef-2c2399a7b578 Germany
1883f205-3976-4283-8397-26eb947565b6 France
447066ea-1d76-4cc5-aa4e-770312887d67 Netherlands
674f5277-7576-4fb4-99b8-f82b2696cd4f Spain
093ceba4-3512-4c9c-aea4-637123d56417 Netherlands
ff18c3a7-f475-4ca2-83a3-82dadc281c72 Netherlands
5b32d049-ad48-4123-95f2-48f433ef6c19 Germany
81e60ee8-6c0e-44b2-95d5-91c754b56e0e Poland
24c809ec-b12f-4fb3-9cdf-95b8b1032b35 Netherlands
5963c41a-8c00-4cbf-81d0-28eb6ecbb283 Estonia
3f64f079-43e8-47cd-b114-d10d69ba9d34 Greece
3c8f0030-2e09-48d3-8888-aef966763b63 Portugal
153c2cda-5baf-425b-8b35-67feaf39186c Bulgaria
952ae9e2-bdc7-4763-b509-2ba57c09265d Sweden
004b5065-4539-4704-b3b9-a87ac5e094b4 Germany
ee7c403e-febd-435c-a589-2edcd405aea0 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NEN250AFF000XXX
E-Number (Finland):
3641013
EAN:
8015644019679
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
140 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
2.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
2.214 kg
Package Level 1 EAN:
8015644019679

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 17.8 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
2500 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator